HomeMy WebLinkAboutSeptic info � ` " � SEPTIC SYSTEM INVENTOR Y Address: 177 Glendale Dr. PID: 34-118-23 33 0001 � Building Type: residence BRs Install'd for: In Musa: Yes Permit#: none Date of Permit: Installer: unknown System Type: trench Experimental: no Appliances: SYSTEM CONDITION Conformity: 3 Tank Condition: 10 DF condition: 11 Failure Pot: medium SEPTIC TANKS Material: concrete block Capacity: 800 Setback to Bldg: 6 Cesspool: DRAINFIELD Length of Lines: # Lines: Trench Width: Treatment Area: Type of Filter: Soil Boring: no Tile Size: Under Tile: Perc Rate: Setback DF-Bldg: DF Ht above Wt: Soil Type: Limitations: WELL DA TA Setbacks - Well-Tanks: Well-DF: Report in File Pump Type: Depth: Diameter: Method: INSPECTION RECORD PUMPO UT RECORD DATE DESCRIPTION COMPLIANCE DATE GALLONS 8/13/81 no surfacing 2 9/1/89 1800 7/8/87 no surfacing 2 7/23/90 no surfacing 2 9/30/92 DF not located-tanks located 2 10/26/95 DF located-pump tanks 2 4/24/00 non-compliant repair 2010, pump tanks 3 �.� —0�- �ocke�� �� �1-c� c�.i-� Sewc� • - � I 7 � C�l�� ��. `T/- � �J �.Y I _ '� � � _� � � � I O I I � I � � � I I�� �� ��- ,o� I , ; �_ - - r � � �I � T � ��� ���� T� ���t� �'� a � � _o : �:�� � � 0 0 CITY of ORONO �1 ° l ''• � !S� Municipal Offices 'ti �.�� �� � � �.��, Street Address: MailinQ Addross: 1fEgg0 2150 Kelley Parlcway P.O. Box 66 -- Orono, MN 55356 Crystal Bay, MN 55323•0066 March 24; 2000 Calvin Presbyterian Church 177 Glendale Drive Long La1ce, Mn 55356 To Whom It May Concern: An inspection of your septic system was conducted on Apri124, 2000. A summary of the inspection is belo��. Septic Tank Condition 1. Pumpout needed within one year.(Last Pumpout 9/1/89.) The septic system is non-compliant due to a lack of a three foot separation distance beriveen the bottom of the drainfield to the seasonally high watertable. The three foot requirement is a State Code, not a City Code. A soil boring was conducted to determine the depth of the seasonally watertable. The sepiic system must be replaced or the church must connect to the sanitary sewer system no later than December 31, 2010. Enclosed is a list of state licensed septic contractors who work in Orono on a regular basis. Also enclosed is a fact sheet e�plaining ho�v a septic system functions properly. Finally, an as-built drawing is enclosed that shows the approYimate location of the septic system. If you have any questions regarding this report, please contact me at the City Offices at 249-4600. R �iectfu y, �' / '%�J -�'C+�✓ is Pe ce On-Site Systems Manager Enclosures In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be adcised that this report does no guarantee or certify the existing system will continue to function properly,but is mereh•an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us CITY OF ORONO � O� Municipal Offices O ,� O Post Office Box 66 Crystal eay, MN 55323-0066 a � ON—SITE SEWAGE TREATMENT �+ � INSPECTION REPORT ti ��9kESH�4�G Owner: ���Ui� ( ���/✓��� Address: I� C,IE'r'�(�((�If�. l��', Permit #'s: l ��� Dates: � Contractors: /�^1V'10��Y� City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. 7he on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is � an existing system [ ] neu construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and uhich is operating satisfactorily by treating and disposing of the entire current sewage input uithout discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the current City Codes, but uas installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface uaters. 3 "NON-CONfORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has or,�1, has not been identified at this time. if the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. 7anks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be punped out uithin 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 0 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been purnped out within the l a they should be pumped out now. ��-s a� p�m ' DRAINFIELD CONDITION (11-14): Dr field inspection indicates: Drainfie[d is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector irtmediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): ����✓� COMMENTS: � Date of Inspection S pt' System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the pre�nises with the system loc�tion and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO � O� Municipal Offices O � O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT „� � INSPECTION REPORT ti ��9kESH�4�G Owner: �C�Fl10ah �S�ir',ia�'�.U1 UIr+C+Bddres s: ��/ ���t.�/t' LJi'. . . Permit #'s: /�DYI� Dates: `� Contractors: '— City ordi.nance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked beloW. (This is f,�, an existing system [ 7 new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORM[NG SYSTEM'�-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface uaters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has or f�}. has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): � Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): Drainfield insPection indicates: 11 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. � Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): ���` J COMMENTS: Date of Inspection S tic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will contin�e to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available tnformation. This report must be kept on the prE�nises with the system locatien and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner On the North Shore o f ON-SITE SEWAGE TREATMENT LakeMi�znetonka INSPECTION REPORT � POST OFFICE BOX 66 � - � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER ! .lil/Llh ��{ j�PY-�pn �1Nli1'� ADDRESS /�" /�' ,/�j; PERMIT NO.'S. DATES -� CONTRACTORS — City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is � an existing system ❑ new construction) � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly, {� 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, ��� located, and constructed enerall 9 y in accordance with previous codes.System appears to be functioning properly; no major upgrading of the system is required at this time. � 3 Dces not meet current City standards in many respects relating to design,construction,or location,Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard, or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary, soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not �❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks Solids aecumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Dra,i_n.}ield inspection indicates: should be pumped out as soon as possible. I2�Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure ❑ Slope (depends on soil types,water Site Capabilities for ❑ Soil Future Expansion table,and system condition) �Adequate ❑ High water table �Low ❑ Lot size ❑ Fair ❑ Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High . ❑ Drainage ❑ Inadequate ❑ System is causing visible surface discharge. COMMENTS: 7` " S--9 �- Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current co�ditions based on the available informatio�. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner On the North Shore of� Lake Mi�z�zetorzka ON-SITE SEWAGE TREATMENT INSPECTtON REPORT � POST OFFICE BOX 66 � _ � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER �a�V�.n �hu(�I1 ADDRESS ��� �'����a`� �� �J�. PERMIT NO.'S. DATES � CONTRACTORS J City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is � an existing system ❑ new construction) � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. 1�1 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, �� located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major upgrading of the system is required at this time. � 3 Does not meet current City standards in many respects relating to design, construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply, or is a source of potlution to surface or groundwaters,or is creating a safety hazard, or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing wili usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( � Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directiy over tank baffle. (Does not � Pumpout not needed at this time. �f1�x'� y��r) give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems, should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. � Orainfield is dry,no surfacing evident.(in �(�vwme='�- a�-'�=� ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ,� Inspection risers missin�_tanks.could_not_be ins�ected_ effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe) must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) � Adequate ❑ High water table ❑ Low � Fair ❑ Lot size � Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑ System is causing visible surface discharge. COMMENTS: �d� �Q'�'1 ��� QC�� C��Ar>`�L�i�c� Y�,k,\ _� �Y•11,�2.. '�-4"�c✓ / ' � n � c�� ,r��r-;srz,r� �� n�-�-�«�� �3-� �-�- �,m� �_ � _ �� � s Date of Inspection Septi t�m Inspector v Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner