HomeMy WebLinkAboutSeptic info , ,�."�
� O�
O , O CI'TY OF ORONO
s��,:.-
� Municipal Offices
�3 ��, ' � :;.y �
r�, t�y � Street Address Mailing Address:
� � G 2750 Relley Parkway P.O. Box 66
� Orono, MN 55356 Crystal Bay, MN 55323-0066
9kESH0�'
To: The Current Owner of Address 730 GANDER RD
City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a
periodic basis. The onsite sewage treatment system at the above address has been inspected and
the following is known about the system. A sketch of the known components of the system is
available for most properties at the Orono City Hall.
Imminent Public Health Threat
Yes =�No
If yes, please contact the Onsite Systems Manager at 954-249-4626 within 10 days of receipt of
this notice. The septic system must be brought into compliance within 90 days. Failure to do so
will result in referral to the City Attorney for legal action.
System Identified as -Compliant
Yes
No
If yes, system must be brought into compliance by:
December 31, 2007
December 31, 2010
Other
Septic Tank(s) Pump out Needed
Yes �No
The city recommends the septic tank(s) and/or lift tank be serviced and pumped out every three
(3) years. City records indicate the tank(s) were last pumped out on 1 I— ( �'S'-o S
The tank(s) should be cleaned through the manhole and not through the inspection pipes, this
allows for proper cleaning.
Comments:
� C�!/�'�-�.�.J`G �f
In ect r: �'d
sr • latc �f Inspccti�n:
Telephone (952) 249-4600 • Fax (952) 249-4616
www.ci.orono.mn.us
, -- t
Septic System Upgrade Deadline is Approaching
Here's a friendly reminder to all Orono property owners with non-compliant onsite septic
systems. Be�inning in the mid-1990s the City began to identify those septic systems that
made use of trench drainfields, a majority of which do not maintain the minimum
required vertical separation above seasonal water tables. Each e�istinb system was
subjected to soil borin�s to determine the seasonal water table depth. When a system was
identifi�ed as non-compliant, the owner was notified of the need to bring the system into
compliance and given several years to complete the upgrade.
The deadlines to upgrade were divided into whether or not the property was in the
Shoreland District (within 1000' of a lalce, or within 300' of a protected tributary stream).
Properties in the Shoreland District were given until December 31, 2007 to become
compliant. Properties outside the Shoreland area with non-compliant systems were
allowed until December 31, 2010 to conform to the septic code.
Don't wait until the last minute! The City is strongly recommending that property
owners not wait until the deadline arrives to brinb their systems into compliance. The
process to upgrade your septic system can be quite lengthy. The first step in the process
is to hire a site evaluator & designer to deternline what type of system is required and
provide the blueprint for the system installation. The property owner must then contract
Wi�i1 ?x S�yt1C SySt�17: :::St�11PP t0 �:��J�t�1� S)�gtPm CQI1Stn„�rt�r,j.
The installation of septic systems is very weather dependent, especially for mound
systems, which can only be installed when the �round is relatively dry, i.e. ty�ically June
thru September. Contractors' schedules fill up quickly, so it's important to start your
planning and desian process now to ensure a timely installation. The period of time from
decidin�to update your septic system to the actual installation can easily exceed three to
four months or more. Please contact the Building and Zoninb Department at (952-249-
[1Fj(�f�l �n�it}1 ?ny' it1PSt10pS vOLi 1_'1_2c1y �1c�Ve 1�'tOUt bTlila'ill� y011T SeUt1C SVSte1T1 111t0
compliance.
F'or a Tist of Iicensed desi;ners and installers you �nay bo to ���m��°ev.��-�a��.�a�a.ua�,
elick on City I)epartments, clic�: on Se�tic, then clicfl: on �he 1in�: to
ww��-.pca.state.inn.us!pro�rams.
//� O�
��O O \
!' „ ��,y�::_ �,��; CITY of ORON�
� ���� +�,� ���1 r � �r �� Municipal Offices
,`�� � �� I�.
�� rt� ��
�,,, � �,�ty�. ,� , ,,,_� �ti�;' o
� � f i + Street Address: �15a.-a�-{q-y6 � Mailing Address:
,
�,. � �1 �
•,��._'`9.IfE$Kp'¢'�:�' 2150 Kelley Parkway P.O. Box 66
��—%' Orono, MN 55356 Crystal Bay, MN 55323�0066
� /
To Current Owner: Address: � �G'�? (.�'/-�.1 ��� �� �
City Ordinance 199 requires that each existing on-site sewa�e treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3): `3
1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and consiruction standards of the current Orono
Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or eazlier,and
which is not failing or an�*nm;nent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipa]Code and which is failing for any
reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soii characteristics.
TANK COI�TDITION(5-7): �
Tanl:inspection indicates:
5 Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
Tank was last pumped (,, ,- b - c1� )
Malce sure septic tanks are pumped throuoh manhole and not through white inspection pipes. This allows for the proper
cleaninQ Keep water softner and iron filter discharQe out of septic svstem to prolonQ life of drainfield. Ask pumper to test
afarm float to verify alarm is still working in vour house. The alarm warns owner that septa�e is about to backup into basement.
7 Inspection risers missin�-tanks could not be inspected. Lnspection risers(4" dia.pipe)must be installed in each tanic. If
tanl:s have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD C0�IDITION(8-10): �
3 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing, not critical yet
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
� immediately.Repairs must be completed within 90 days. �
i
a
G OMMENTS:
�. .�- �*��� �� �;
� .��^�.%�_� *�
Datz of Inspection Septic System Inspector
,/% (7,j�,�,
��' � ����
i�0�: �
�� � ���� �� � C ITY of ORONO
;, ,
'�,� ��, �� ; . �
� � :
;�,, � `� �i : i �ti%-� Municipal Offices
�, �- .
G �
��.� " � '�' '�' �;,;� Street Address: Mailing Address:
� ,.�,
'��9�i'Egg04'::-' 2150 Kelley Parkway P.O. Box 66
� Orono, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: Address: � 3� C'`''��%J� r' ��
Ciry Ordinance 199 requires that each existing on-site sewage h•eatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3): �
1 "CODE SYSTEM" An ISTS which meets ali the location,design and construction standazds of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all tlte location,design and construction standards of the current Orono Municipal
Code but does meet tlle three foot separation requirement or nvo foot requirement for systems installed 1996 or earlier,and wllid� is not failing or
/�\ an imminent threat to public healtl�or safety.
( j � "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may
v or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is fai(ing for any reason;aiid
any(STS with less than tl�ree feet of unsaturated soil or sand between die distribution device and the Iimiting soil characteris[ics.
TANK CONDITION(5-7): �
Tank inspection indicates:
�� Pumpout not needed at this time.
(6 I Septic tanks must be pum�ed out this year (city code requires tanks to be pumped out once every 3 years.
�'� Tank was last pumped 1—�Z�'� ).
Make sure septic tanks are pumped throu�h manhole and not throu�h white inspection pipes. This allows for the
proper cleaning. Keep water softner and iron filter discharge out of septic svstem.
7 Inspection risers missing-tanks could not be inspected. Inspection risers (4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the Last three years,they should be pumped out now.
DRAINFIELD CONDITION(8-10): �'�5'
�8�, Drainfield is dry,no surfacing evident.
�� Some evidence of surfacing, not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
COMMENTS: Q<<.,,�.�-.-�i l ;S s,�,r,- (_c�-.`s 1;�,,��- �,��1 r,��f-- ��` �c�,�,c�C.� b �
��-�1 ��.^1�: - ��, c--(3 S'�1 �--� �-o..c��.5 ����L ��try 3 �F�;�5 ,
S
� =�, -�� � ����-;--,
Date of Inspection Matt Bolterman - Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that th is report does not guarantee
or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
Telephone(952) 249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
� o�
o �:�, o
��`��� CITY of ORONO
,�:.- �
�, ��1����, --� �ti
� � , _��� Municipal Offices
�f`� �'��```�_'�yG Streat Address: Mailin�Addreu:
�E+gK O g' 2150 Kelley Pa�kway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: M��' �� �����5 p� Address: �3 D G�,�d e�' 12c1
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3): �
1 "CODE SYSTEM" An ISTS which meets all the location,desi�and construction standards ofthe cuirent Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,desigt and cons4vction standards of the curtant Orono Municipal
�� Code but does meet the three foot sepazation roquirement,and which is not failing or an imminent tlueat to public health or safety.
( S ) , NON-COMPLIANT SYST'EM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
�/
" or may not meet all ihe locatioq design,or construction standards ofthe cuirertt Orono Municipal Code and which is failing for any reuon;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characceristics.
T.4NK CONDITION(5-10): S
T:uik inspection indicates:
� Pumpout not needed at this time.
6 Tank must be pumped out this yeaz (city code requires tanks to be pumped out evecy 3 years. Tank was last pumped �—�—�� ),
7 Solids accumulalion in tanks is at a critical a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out withirt 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected Inspection risers(4"dia.pipe)must be installed in each tank at next pumpout If tanks
have not bean pumped out within the last three years,they should be pumped out now.
1� Inspedion pipe is located duecUy over tanlc baffle(does not give accurate measurement of solids accumulation). If tanlcs have not been pumped
out within the last three years,they should be pumped out now.
DRAINFIELD CONDITION 11-14 : �\
11 Drainfield is dry,no surfacing evident
12 Some evidence of surfacing,not criticai yet ,
13 Draintield is saturated and visibly dischazging untreated e$luent to the surface. Contact the City Inspector immediately.Repaics must be
completed within 90 days.
14 Drainfield extent and condition unknown
CONII�IENTS: S�S�-er.� �.S �a�— Cor.,pl ;q,�� ��c t-o Iac�� �� 3 �-oo� S��er�,fi�a�
bcr.�r�� � a� so �� �.-�r'��,6\� �oRe o� rc�c,�e5 . 6
�a-31 -ao iD
���'-°1 `��'l�c� ��+�Pn�,,.,
Date of Inspection Septie System Inspector '
Note: In the everR that Uvs inspection report is used to satisfy the requirements for a moctgage or other transfer of property,be advised that this report does not guazantee
or ceRify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under currrnt conditions based on the available
informatioa
CITY OF ORONO � O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT
1`, � INSPECTION REPORT
'C�� G~
9kESH���
owner:( �✓�•S��`A�JL� 9[C��S�_V�1� Adclress: � � /� 55'3�J /
Permit �'s: 5755 Dates:__l(,'-•�`l`'� Contractors: � C`�' �
City ordinance number 100 requires that each o�-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is�an existing system [ ] neu construction)
SYSTEM CONFORMITY (1-3):
1 ��COOE SYS7EM'�-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system Which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system uith less than 3 feet of unsaturated soil or sand
betueen the distribution device and the limiting soil characteristics.
(The limiting soil characteristic has or [ 7 has not been identified at this time. [f the limiting soil
characteristic has not been ident� ie , this classification may be subject to revision.)
TANK CONDITION (5-10):
T�enl4 inspection indicates:
�vl Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be purnped out as soon as possible.
8 System is discharging to the surface. Tanks must be pixnped out within 48 hours to etiminate surface dischar�e.
9 ]nspection risers missing-tanks could not be inspected. Inspection risers (4�� dia. pipe) must be installed in each
tank at next purt�out. If tanks have not been purtiped out within the last three years, they should be p�mped
out now.
10 [nspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not bee� punped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
Dp�f�field inspection indicates:
L�Drainfield is dry, no surfacing evident.
1Z Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
imnediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING S1TE FACTORS (slope,setbacks.etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table,etc.): m�� �(�y�
COMMENTS: S�wTl c' S jj i.s cr�tCc�Yl�arw�i� �-'i�? �� q�G t�Y�-rv_ �c��'7� �''
j-�,�,'�
2 i In �` �C c. �. r w�1 li F . 1 �i�:-
_7c �C, � r
„_ .- '�
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system uill continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the pre�nises uith the system locptien and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
�
o�
o :j o
i � � - ^ ! CITY of ORONO
,� '�����;j�� -� �
' f� '� !� ��� �l�� Municipal Offices
� �� ��.'� � -
'� `�r'�'�,`:'''!��<��'� G
��'`�"'<'�' , �z� Street Address: Mailing Address:
l y ��;����" �
�kESHO�' 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: '�' /� � Address: 730 Gander Rd.
Permit #'s: 5755 Dates: 10/3/79 Contractors: Widmer Bros.
(This is [x] an existing system [ ] new construction) .
SYSTEM COMPLIANCE (1-3) : 3
1 Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
� Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom
of the drainfield and the saturated soil level.
(The saturated soil level [�] has or [ ] has not been identified at this time. If the
saturatad soil level has not bean identified, this classification is subjact to revision.)
T K CONDITION (5-9) : 5
5 Pumpout not needed at this time.
Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
(During the last septic tank Maintenanca Pumpout tha tanks [ J were or [ ] were not confirmed
to be watertight by the licensad pumping contractor. If the tanks wa e not confirmed to be
watertight, this classification is subjact to revision.)
D INFIELD CONDITION (11-14) : 11
Drainfield is dry, no surfacing evident.
2 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface.
Contact the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medivm
COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings
were performed to verify a 3 foot separation between the drainfield and the seasonal water
table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the
septic system is required by 12/31/2006.
�'-1�9� �
Date of Inspection Se ic System nspector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 4�3-7357 • FAX 473-0510
%��O \\
� ��,
,!O O'���������
. ;�q ; j�� �;;- � CITY of ORONO
.� .. , ,
,\� ��-�y , ,f �%� Municipal Offices
����,� � � �'�`�',�G�� Street Address: Mailing Address:
i
\��CEggOg'� 2750 Kelley Parkway P.O. Box 66
�---� Orono, MN 55356 Crystal Bay, MN 55323-0066
� - � � �
Owner: Address:730 Gander Rd.
Permit #'s :5755 Dates :l0/3/79 Contractors :Widmer Bros.
(This is � an existing system [ ] new construction)
SYSTEM COMPLIANCE (1-3) : 3
1 Code Svstem: Meets or exceeds current City standards in all respects relating to
design, construction, and location. Appears to be operating properly.
2 Compliant Svstem: Does not meet all current City standards for new construction,
but in most respects appears to be designed, located, and constructed in accordance
with previous codes and is functioning properly.
� Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the
current input; and any system with less than three feet of vertical separation
between the bottom of the drainfield and the saturated soil level.
(The saturated soil level � has or [ ) has not been identified at this time. If the
saturated soil level has not been identified, this classification is subject to revision. )
TANK CONDITION 5-9 : 5
5� Pumpout not needed at this time
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been
pumped out within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If
tanks have not been pumped out within three years, they should be pumped out now.
(During the last septic tank Maintenance Pumpout the tanks [ ] were or (� were not
confirmed to be watertight by the licensed pumping contractor. If the tanks were not
confirmed to be watertight, this classification is subject to revision.)
IIBAINFIELD CONDITION (11-14) : 11
� Drainfield is dry, no surfacing evident.
12 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface.
Contact the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system aqe and condition, soils, etc. ) : medium
COMMENTS: The non-compliant septic system must be repaired by 12/31/2006 or within 90 days
of failure (surface discharge) , whichever comes first.
C.� '1C�
Date of Inspection pt c System Inspe tor
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue
to function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 • FAX 473-0510