HomeMy WebLinkAboutseptic info � , �_ • • • • e � To: Orono residents on mound type septic systems From: Willie Gibbs, ISTS Manager Date: May 10, 2006 Re: Landscaping Do's and Don'ts for Mound Systems, Quick Reminder Do plant and maintain a full cover of grass and keep mowed to a normal height, this grass cover aids in the evaporation of large amounts of effluent(the fiquid left after the "othe�' stuff has been removed) in the summer time and allows the mound system to help breakdown nitrogen in the effluent, Do water the grass over the mound in extreme dry conditions, sparingly. Do avoid unnecessary foot traffic over the mound, mow it and stay off of it. This is especially true in the winter time. Even human foot traffic can cause frost to penetrate the mound resulting in potential freezing problems. Do inspect your mound system annually for winter kill, (reseed if necessary) animal damage, (burrowing)or signs of potential failure. Do not plant trees or shrubs on the mound system, smaller trees and shrubs may be planted at the edges. Remember, that sunshine is the key to a healthy mound system. Do ask questions, if you have any concerns or questions concerning your rnound system please feel free to call me, !can be reachec4 at 952-249-4626. 1 FROM : R''i� PHONE N0. : 4422091 Oct. 29 2002 01:25PM P2 2/25/OZ water/Wastewater-ISTS4.31 � Compliance Inspection Form for Existing Individual Sewage Treatment Systems Minnesota Pollution i� Control Agency Cvmpleiion of this farm fulfills the minimal requirements of Minn. Stat_§ 115.55(2001)and Minnesota R_ ch. 7080(�s99�, Please refer to local ordinances for olher requirements or informatlon, especially for compliance requirements for bedroom additions. General• Date of ihspe�tion:,� �l�Z Reason for inspection: � �iiv Property Owner(s)_� _���itl� I]i� Telephone � �73- �-s G 7 Person requesting inspection SA�n � Telephone ( ) Site Address ZZ 5�S �2�JGl�„ �A�e� ,�c� City f.vAy2A�i9 Zip Cade S'.s'3Q/ Fire No./ Parcel Nv. County�N�)��!��-� � Township '�"` - Legal Description Local Regulatory Authority Date system constructed �'�' � System in Shoreland Are yes o System in Wellhead Protettion Area: ye no S�/stern serving a MDH licensed facility: y no Local Permit# (if any) 89S"� Systems built prior to Apri! i, 1996 and not located in Systems located in Shorelahd or Wellhead Protection 5horeland or Wellhead Protection Area or Serving a Food, Areas or Serving a Food, Beverage or Lodging Beverage or Lodging Establishment Establishment, or systems Built after March 31 1996 Is the system an imminent threat to publi�health ar Ys the svstem an imminent threat to public health safetv� (a yes answe�is an I7PH5 system) or safetv? (a yes answer is an ITPHS systemJ -�ischarge of sewage to the ground su�face7 YES NO - Discharge of sewage to the ground surtace? YES O -Dlscharge of sewage to draintile or surface watersl YES NO -Discharge of sewage to draintile or surFace waters?YFS N -Sewage backup fnto dwelling? YES NO -Sewage backup into dwelling? YES -�tuation with the potential to immediately and - Situation with the potential to immediately and adversely impact or threaten public health or adversefy impact or threaten public health or safety7 YES NO safety? YES� Is the svstem failinq? (a yes answer is a fai/ing system) �s_the system failinq? (a yes answer is a fai/ing system) -Less than 71N0 feet of vertical separatfon between -less than THREE feet of vertical separation between system bottom and saturated soil or bedrock? YES NO system bottom and saturated soll or bedrock? YES -A seepage pit,cesspool,drywell, or leaching pit? YES NO -A seepage pit,cesspool, drywell, or Ieaching pit? YES Is the svstem non-compliant? Is the svstem non-com�liant? - Is the system regulated under a monitoring plan or - Es the system regulated under a monitoring plan or operating permit? (it no, go to page 2) YES NO operating permit? (if no, go to page 2) YES,� If yes, If yes, -Has the required monitoring taken place? YES NO - Has the required monitoring taken place? .. (If no, ihe system is non-complying) (If no, the system is non-complying) �Does the monitoring indicate that the system meets - Does the monitoring indicate that the system meets performance expectations? YES NO perfOrmance expectations? (If no, the system is non-complying) (If no, the system is non-complying) Page �. of 2 wq-wwi�4.31 FROM : R`�S PHONE N0. : 4422091 Oct. 29 2002 01:26PM P3 �— �E1��J�lJ e /� __�Fire No./ Pa�cel No. Property Owner(s)�11��1 ._....._,.,..,.....__..... S stem Com onents (Please desc�ibe the system components and attach site sketch showing system/ocation).• (�� /z�`O �.z� " L'`�S I S'�',�%G_ �e��—., � �zs� ��-ca�i �, P G�Rn► �� J� i mo�►.�d � m, What etho were sed to make the termi ions fon c �om I' ce ins e ' ? (Note:No standard protnciol exists The following/ist is nat erhausdve, or in sequential order no�indlr,dtes which combinations may nec�ssary to make a determination) Watertight tank(s) Hydraulic Functioning VetCical Separatian Distance � Probed tank bottom � Searched for surface outlet �I ConducCed soi! borings � U Obsen►ed low liquld level ❑ Performed hydraulic test Depth to limiting layer� � Examined const. records � Searched for seeping in yard Depth to system bottom Z � Examined empty(pumped)tank � Checked for back-up in home � Examined records o P�obed outside tank for"black soil" o F�ccessive ponding in soil system/D-boxes ❑ LGU limiting l.ayer Verification ❑ Pressure/vacuum check � Homeowner testimony ❑ Othe� O Other o Exami�ed for surging in tank 0 "Black soil"above soil sy5tem ❑ Othe� Status of the s sv tem. Based on the compliance Criteria,the systerrt status is: (�heck one) ❑ failing (to protect g�oundwater) ❑ an imminent threat to public health or safety (ITPHS), 0 non-compliant(monitoring issue)�compliant(none of the 3 p�evious conditions). Therefore,this document is a:�Ce iF te of Compliance ❑ Notice of Noncompliance Is this s stem an EPA Class V Injection Well? ❑ es no Ce ification I hereby certify as a state of Minnesota licensed Inspector and/or Designer I or Qualified EmPloyee Inspector and/o�Qualified Employee pesigner I that I conducCed an investlgation that accurately determined the complfance status of this system and that my recorded observations are accurate as of this date. No determination oF future hydraullc performance has been nor can be made due to unknown conditions during system constructlon, abuse of the system,inadequate mainbenance,or future water usage. Inspectors name (p�int) JEFF SWEDLUND Phone �.�`G�S�.�/G'3 S/ License and/or Registration Number 398 Address 7?7� d�Cor�.4 /�l�E– �F�-/�� Employed by �G. Address �^�� Slgnature J �-- Date �O l�—O� UDQtadE R@C1Ui1'Efil@17ts_ �derived from Minnesota Statutes§lYS.55) An ITPHS must be upgraded, �ep/aced, or its use discontinued within ten months af receipt of h5is nadce o�within a shon'erperiod if requ/red by local ord/nance. !f the system fa/ls to pmvide su�cient groundwater prot�ction, then the sysCem must be upgraded, r�placed,or its use discondnued with/n ohe time requ/red by ru/e or[he loca/ordinance. If an ex/sdnq system is not fai/ing as defined in law,and has aC leasC two J�el'of design so/l seperatian, �hen the system need not be upgraded, repaired,replac�d, o/its use disconG'nued, notwlt�standinq any local ordinanc�e that is more strict. This does not apply to systems/n shore/ar�d ar�as, wellhead pr�ltYt/o�areas, or Chose used in conne�b�on with foad,beverage,and lodg/ng establishments as defined in/aw. Suaaested Al�achmeets 1) Site sketch could also include: well, well setback tn system, dwelling or other buildings, t2hk(S),reserved soil treatment area, surface water and soil boring Iocatlans. Include as-built drawing if avallable. Z) Soil boring logs, showing each horizon� Indicate the texture,color, redoximorphic features depth to bedrock,stdnding water and whether the mate�ial is filf. 3) A list of any and all requirements of the local o�inance that are different f�om the state requirements refer�ed to on this form. 4) A homeowner survey of system performante, signed by the homeowner as being factual_ SJ Monitoring data as appropnate. n�,.,. � ..f� FROM : RYS PHONE N0. : 4422091 Oct. 29 2002 01:26PM P4 Site S�Cctch: , _„ . . . . , ..... ..; _ ' . � . . . ' ........� . ....... . ' ._ . f .. . .. ' . � � �: . ., , .. :: : :� . � :, � :; � :� .��}�,c?.,�:'� : . :. � :::. � . . � . . . . . , . ...;...;�.� ...:�::... , _ . .;., ...;.. .. � . . r ' l.� . .. . . . .. ..,.. . ., . � .�.������ .. :: . . . � . � . .. � � ...,_.. .. . � . .�. ��:��.�� .. . � �r .. .. � . .. . . .. . .. �� . .. . �� . .� ..;... ...;. . .:... . . .�...;.. . . . . . . ., .. _ . . .. . .. : .. . .;.. . . .. . . ...;.. . .. ,.�. . . , . . . . . � ., . . ...�. . . .. � .. , too� . .. � . . . , � -- . . . ' ,. . .. • ..;�- � io� 20� . . . . ....., . . ; .. . . .. . .. . . N . ; .� .. � . .. . -- .. � ...:;._ .. , .. � w��i� .. .. . .. . .. .. . .. . , .. p tdU` Pleuse indicatc the]ocafion of: Wcll,nell setba�k iu sysiesn,dwelling or qthe�e3t�bli3hmrnt,ta��k(c).soil(rett�lcnt syste.m, rese�vcd soiJ lraa�rr�cnt arca,citrtain drain,rropz�l�'lines,watcrways,and buried lincs (�t►osc N0�'iusu�lled b�•thc utilin�). Include gi�e;and IongCh And approximate distanecs f.�orta fixed reFercncc poi�its such u slrcrts and buitdii�gs. Pleasc attach as- builc dra��ings, inspec[ion reports,Certificat(sj ofCompliance:ind�1c�ticc(s)ofNo�uamplism��,if Ah•ailabl�. Soi1 Bo,•ings (BR!�): Locate each boring ora the inap above,indzcate on She r��hi of.tl�.c Co1��1Yin The soil texture, strucnue, col�c, depth of each different soil type, evidcnce of motl•ling, bedrock and st�uzdiiag w•at�x- Also i.udicace if the uiaterial is lill. f dH� B�t n I3R# BR# BK# I3R# BR� O/� � �Z '/� s`� 3�3 -�„ - — RrCORD��P7'H��F��iu1'TLII�G,SEASC��/�L 171�;T; wq�'��qR B�UROCkQh ADOVE L1�lf_S ,.—r �/ 7 C(i�nmrrtti: 1.99iv s(� ��'If.�.������� ���� ��'r�/.�.+.� - -- �Viiat nccds t��bc c��m{�lezed[i�Uring tl�e�>>si�va.�s[a�t1 ir�to cuct�pii:�noe il found nor in compiiance?_,_ d/ i iu Q r FRQM : R�'S PHONE N0. : 4422091 Oct. 29 2002 01:27PM P5 • Oct-I;-10G? 12:5n��r, Ficm-CITY OF ORONG +95224946!b "-278 ? C0:/002 F-680 ���;� �,����.� ��1�. �2�, ;i � � i , � ; J�nr,is I `� C�--� ' , � i ��,���,.. , � �� ; , � , �,I� � `�� ; / � -. I � � `�, �� ` II �I ` � � \ l � \ f �� � � � � ��,� , �; � �� � m� � o.,. ��� � �' -��� �� � �b� �� �a �"' gd� � �g'U � � q�5 � ��' �o � ,� .` � l T�'�� `�� l� � � .,� �,� ��, ?� ° , � � . \ �. � � � �. � ` � , ��r� 1�T"1 L..�r) '� \I � / � / i ` '� � O I O , O CI'TY OF ORONO ����. _ � � � � MunicipalOffices r�,, ;�` �, Street Address Mailing Address: � G'�' 2750 Kelley Parkway P.O. Box 66 'L9 �i Orono, MN 55356 Crystal Bay, MN 55323-0066 kEsx�4`' To: The Current Owner of Address 2245 FRENCH LAKE RD City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health hreat Yes No If yes, please contact the Onsite Systems Manager at 954-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non- ompliant Yes No If yes, system must be brought into compliance by: December 31, 2007 December 31, 2010 Other Septic Tank(s) Pump out Needed Yes No The city recommends the septic tank(s) and/or lift tank be serviced and pumped out every three (3) years. City records indicate the tank(s) were last pumped out on t O - '�—p.6 The tank(s) should be cleaned through the manhole and not through the inspection pipes, this allows for proper cleaning. Comments: � InspeC c�r�� , � ��_ Date of Inspection: (p ' O 7 Telephone (952) 249-4600 • Fax (952) 249-4616 www.ci.orono.mn.us � �� O , : O �� � ; C ITY of ORON4 ,Kr,�', Y,:.:� _ �a r ,,- �� '��'��'' �,� ��r� _ �, i Municipal Offices �'�+, `"'��t� jl N-.\�� ,�'/;/, \��,� � � � ���;;e���;���/ Street Address �15a-a4q`�6o o Mailing Address � \��`4�E$K_p4 j 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 To Cunent Owner: Address: o�v2`fS ���'�C'�� �-t� � R� City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYST'EM CONFORMITY (1-3): I 1 "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and conshticUon standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an iffininent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may or may not meet all the location,design,or construclion stan�rds of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soIl characteristics. TANK CONDITION(5-7): � Tanl:inspection indicates: 5 Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code recommends tanlcs to be pumped out once every 3 years. Tank was last pumped ). Make sure septic tanks are pumped throu�h manhole and not through white inspection pipes. This allows for the proper cleaning Keep water softner and iron filter discharge out of septic system to prolon�life of drainfield. Ask pumper to test alarm float to verifv alarm is stii!workinQ in your house. The alarm warns owner that septaQe is about to backup into basement. 7 Inspection risers missin�tanl:s could not be inspected. Inspection risers(4" dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION(8-10): � 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not criticai yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the Ciry Inspector immediately.Repairs must be completed within 90 days. COMMENTS: � (� .��� -c� S- �� Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not euarantee or certifv that an existinQ svstem will continue to function properly, but is merely an opinion of the adequacy of the system under current % �' � �� ��O . O���� �' ,�:;}� � ;,,:.e_ l�� � C ITY of ORUNO '�� � 4 a.l f: ..,:� /�7 ° � i� i 15��l Municipal Offices �,"�'' ��' ', �, i, ,. ,� �� � . ,� ' �,', � }�` � G Street Address: Mailing Address: �,'' �'�`q�EggO�':%'� 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: ��`�S �{��'��� �`=�k` �(,� City Ordinance 199 requires that each existing on-site sewage t�•eahnent system in Orono be inspected every two years. The on-site sewa�e treatment system at the above address has been inspected and appears to fa11 into the categories checked below, SYSTEM CONFORMITY (1-3); � � '�CODE SYSTEM" An ISTS which meets all the location,design and construction s[andards of tlie current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet al(the focation,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not faii ing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A proltibited ISTS;an ISTS located widiin a designated 100-yeaz flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any I3TS with less than three feet of unsaturated soil or sand between the distribution device and the limi[ing soil characteris[ics. TANK CONDITION(5-7): 5r Tank inspection indicates: 5 Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped �C� �'�..t—c�- ). Make sure septic tanks are pumped throu2h manhole and not throueh white inspection pipes. This allows for the proper cleanin�. Keep water softner and iron filter discharge out of septic system. 7 Inspection risers missinb tanks could not be inspected. Inspection risers(4" dia. pipe)must be installed in each tank, If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION(8-10): � 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacin�, not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. COMMENTS: C����� ��t;�� �1�� ����� S1� r. � }t,��5 a;OC�� . �—� —t'`.� '� �"�c� �� '�--� Date of Inspection Matt Bolterman - Septic System Inspector Note: [n the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properiy,but is merely an opinion ofthe adequacy ofthe system undercurrentconditions based on the available information. Telephone(952) 249-4600 • Fax(952)249-461b www.ci.orono.mn.us � o� o ;_}� o �:�--� CITY of URONO .� ��� � � � �� �� �`��,��. �' titi M�� ot�� r ��(,'�. �-,. �G Street Addross: Mallin�Addreu: �04' 2150 Kelley Parkway P.O. Bax 66 Orona, MN 55356 Crystal Bay, MN 55323-0066 Owner: ��o c�-�q S �����-,�` Address:_ �d�f s 1=r'e���, ��ke �� City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and agpears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): I Ol "CODE SYSTEM" An ISTS which mcets all the location,design and constcuction standards of tho aurent Orono Municipal Code. 2 "COMPLIANT SYSTEM�� An ISTS which does not meet aii the locatioq design and coastniction standards ofthe cuntnt Orono Municipal Code but does meet the three foot separation requiremrnt,and which is not failing or an immiaeat threat to pubGc health or safety. 3 NON-COMPLIAIVT SYST'EM" A prohibited ISTS;an ISTS located within a desigoated 100-year flood plain,any ISTS which may or may not meet all the locatioq design,or coastruction standards of the cuirrnt Orono Municipai Code and which is failing for any reason;and any ISTS with less tban three feet of unsaturated soil or sand between the dis4ibution device and the limiting soil characterystics. T.ANK CONDITION(5-10): � T:uik inspection indicates: • � Pumpout not needed at this time. f> Tank must be pumped out this year (city code requires tanks to be pumped out every 3 yea�. Tank was last pumped 6-�a-�� � 7 Solids accumulation in tanks is at a critical a crilical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 houcs to eliminate surfare discharge. 9 Inspection risecs missing-tacilcs cuuld not be inspected, Intpection risers(4"dia pipe)must be installed in each tar�k at next pumpout If tanks have not bern pumped out within the last three years,they should be pumped out now. 10 Irupection pipe is located directly over tazdc baffle(does not give accurate measuremrnt of soGds accvmulation). If tanks have not been pumped out within the last three yeais,they should be pumped out now. D LD CONDIT'ION(11-14): \� 1 Drainfield is dry,no surfacing evidrnt 12 Some evidence of surfacing,not critical yeL 13 Drainfield is saturated and visibly discharging u�reated efflurnt to the surface. Coirtact the City Iatpector immediately,Repaiis must ba completed within 90 days. 14 Drainfield extent and condition unknown. CONIl�IENTS: s �5�� � \aokS bK � -�- a � �� Date of Inspection Septie System Inspeotor ` Note: In the evart that this inspation repoct is used to satisfy the nquireme�for a mortgage or other transfa of property,be advised thai this repott does not guarantee or ceRify that an eadsting system will continue to function properly,but is merely an opinion of the adequacy of the system tmder currrnt coQditioe�based on the available info�matioa CITY OF ORONO � O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT r� �, INSPECTION REPORT '�t G~ � 9kESH04 Owner: ���Ylf}5 �L12�1Pi/�� Address: �7`�J� ��`�I1C�► L � �<� � ������ �^ /� ,�-� � / Permit �'s: ����J Dates: I''�S�f 7 Contractors: ��vil•.5 ��(��1��`� City ordinance nunber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (7his is �f1 an existing system [ ] new construction) SYSTEM CONFORM[TY (1-3): 1 � "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and uhich is operating satisfactorily by treating and disposing of the entire current seWage input without discharging any pollutants into ground or surface Waters. 2 "CONFORMING SYSTEM"•A system which does not meet all the location, design, and construction standards of the current City Codes, but uas installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants �nto ground or surface Waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located uithin a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and uhich is failing for any reason; and any system uith less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic ( 7 has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): , Tank inspection indicates: 5 Pumpout not needed at this time. � Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. Solids accumutation in tanks is at a critical level. 7anks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 ]nspection risers missing-tanks could not be inspected. Inspection risers (4" dia, pipe) must be instalted in each tank at next pumpout. If tanks have not been p�miped out within the last three years, they should be punped out nou. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been punped out within the last three years, they shoutd be pumped out now. DRAINFIELD CONDITION (11-14): �field inspection indicates: 1 Drainfie[d is dry, no surfacing evident. Sane evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed Within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): -- POTENTIAL FOR SYSTEM FA[LURE (depends on soils,uater table,etc.): �� r , c MM NTs: / ks �`!�° c ^' d�c:t i,G'r�L�i✓/ c'l ��,� � ;F�f u.2a '�. � �� 11� Date of Inspection Septic S stem Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� twt is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the pre�nises with the system tocatien and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner � o� , o , o ' � � C ITY of ORONO � ,�,���r� - � ' � ,�<s � �; �� ti Municipal Offices \"�,� r:r�.,.",�I��;���F_. 'ti i��J;;:. ���! �,�,r�,y ���,��.� Street Address: Mailing Address: �'EggO 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: � J � ���� I ��...�i L/1 1 )1 (�,. Address: 2245 French Laka Rd. Permit #'s: 8955 Dates: B/5/97 Contractors: Don's Backhoe (This is [�] an existing system [�] new construction) . SYSTEM COMPLIANCE (1-3) : 1 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant 5ystem: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level (�] has or [ ] has not been idantified at this time. If the saturated soil level has not been identified, this classification is subjact to ravision.) TANK CONDITION (5-9) : 5 L5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenanca Pumpout the tanks [ ] were or [ ] were not confirmad to be watertight by the licensed pumping contractor. If he tanks were not confirmad to be watertight, this classification is subject to revision.) AINFIELD CONDITION (11-14) : 11 1 Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : low COMMENTS: -� , ,� � ,�-- Dat of Inspection Sept c System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 � o� 0 0 , ,� �l�, ,_ CITY of ORONO � ` . F � ! f<ti,: � �.." �!� Municipal Oftices �,�� ' .�! T�,;���G Street Address: Mailin� Address: � 9�C'E+gK04' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: _��5, ��'��,/Jl Address: 2245 French Lake Rd. Permit #'s: 6384 Dates: 7/22/81 Contractors: Fritz Repair (This is �] an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. � Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil laval [X ] has or [ ] has not bean identifiad at this time. If the saturated soil level has not been identified, this classification is subject to ravision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During the last saptic tank Maintenance Pumpout tha tanks [ ] were or [�] were not confirmed to be watertight by tha licensed pumping contractor. If tha tanks were not confirmad to be watertight, this classification is subjact to revision.) D INFIELD CONDITION (11-14) : 11 1 Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition soils etc. ) : medium COMMENTS: Non-compliant system must be repaired by 10/15/97. —/ ���� � Date of Inspection S tic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 CITY OF ORONO � O� Municipal Offices O � O Post Office eox 66 Crystal Bay, MN 55323-0066 a � ON—SITE SEWAGE TREATMENT r�,. � INSPECTION REPORT '�' Gti �9kESH�4'� ,I�� � -� 1_ Owner• � ��ddress• �' � i Permit �'s: Dates: " Contractors: $� City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-stte seuage treatment system at the above address has been inspected and appears to fall into the category checked belou. (This is f,,�L, an existing system [ ] neu construction> SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system uhich meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but uas installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input uithout discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located uithin a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand .,.� between the distribution device and the limiting sott crtara�rer�i•st-�rts- � ' - --� ---- �r� r�v�r� I�3� (7he limiting soil characteristic has or [ ] has not been identified at this ime. If he limitin�soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): //� .f� Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumPed out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be p�xnped out now. � Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). tf tanks have not been punped out within the last three years, they should be pumped out now. DRA[NFIELD CONDITION (11-14): Dr field inspection indicates: �Drainfield is dry, no surfacing evident. TZ Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City [nspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (sLope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): COMMENT • � <' ,� � �. � � . � �. g t�cP � � r � '�J� Date of Inspection ic �System Inspector � / � .SPC'Gi pcah�� Note: 1n the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of ' property, be advised that this report does not guarantee or certify that an existing system will continue to function �� , property� but is merely an opinion of the adequacy of the system under current conditions based on the available��p(��'N information. , This report must be kept on the prE�nises with the system loc�tion and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO � O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON-SITE SEWAGE TREATMENT � �, INSPECTION REPORT ti ��9kESH��'�G Owner: '��1 � ' Address: ���/S ��nCh �pKl? /cq[. Permit #'s• ?� � � � � Dates: ],sZ�-�,?S� Contractors: f'i�l7L�.S /�'.R��� City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-stte sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is D�an existing system [ ] neu construction) SYSTEM CONFORMITY (1-3): "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactority by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system uhich may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic � has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): � Tank inspection iruiicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next purtipout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been p�xnped out uithin the last three vears, they should be pumped out now. DRAINFIELD CONDITION (11-14): Dr nfield insPection indicates: 11 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): � l� COMMENTS � ' ' c` ' �- � f� ^ — J c� �� Date of Inspection S ptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available tnformation. This report must be kept on the pre�nises uith the system loc�tion and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner On the North Shore o f Lake Mi�rnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 � _ � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER �u � � �'/�'rL��n ADDRESS ��� ���� ��' �`�� ✓ PERMITNO.'S. ���� DATES ��"�'`��f CONTRACTORS � Y �f City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is [� an existing system ❑ new construction) r71 � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating �'1SJ properly, � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major upgrading of the system is required at this time. ❑ 3 Does not meet current City standards in many respects relating to design, construction, or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard, or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( � Checked items may require your action) Tank-nspection indicates: ❑ Inspection pipe is located directly over tank baffle. (Does not � �Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Sotids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: shouid be pumped out as soon as possible. ,� Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe)must be installed in each tank me�t or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table and system condition) Adequate ❑ High water table Low �Fair ❑ Lot size � Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑ System is causing visible surface discharge. COMMENTS: 1� �!°�� -Cl� (/ ' J i'!l�' �t'�"`. � J '— _ � , �_p _�� - � !�"' Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/ Inspector's File GOLD COPY/Homeowner ��� � ,� /� `���� Ozi tl.�e North Shore of Lakc Mi�znetoyzk�r ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 , � � . � � 1335 S. Brown Rd. �� ' Crystal Bay, MN 55323 � 473-7357 OWNER S� InL,ADDRESS r�� y� I�nG�I Lcr�.e� �bGd PERMIT NO.'S. DATES �-�-a - S I CONTRACTORS �' +z `s o i r' City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is � an existing system ❑ new construction) IC�i � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating �•a� properly. � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major upgrading of the system is required at this time. ❑ 3 Does not meet current City standards in many respects relating to design, construction, or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design, construction or location, but is failing to properiy treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary, soil testing will usuaily be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( � Checked items may require your action) Tank inspection indicates: ]� Inspection pipe is located directly over tank baffle. (Does not ❑ Pumpout not needed at this time, give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pum ed out within the last three years, they ed out this year to help prevent future problems. shoul pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates:V shouid be pumped out as soon as possible. � Drainfieid is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibiy discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe) must be instalied in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfieid extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Stope (depends on soil types,water Future Expansion ❑ Soil tabie,and system condition) '�Adequate ❑ High water table � Low �Fair ❑ Lot size ❑ Medium ❑ Poor � Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑ System is causing visible surface discharge. COMMENTS: I l�YlhS �(��a ��, ..� L�U � JJ I�l.-� �r..[�v \/Q,�f� "�"[L_ T -�-� �c�-a�;e l d -�� ��x r,v � �.�5�—L��i rs �- ��-7 Date of Inspection Septic Sy e Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/ Inspector's File GOLD COPY/Homeowner