HomeMy WebLinkAbout2015-inspection-septic tank replacement (tie to permit when available) METRO WEST IIYSPECTIOIY SERVICES, IIYC.
Loren Kohnen, Pres. (763) 479-1720
FAX (763) 479-3090
Mtrowst76@aoLcom
February 9, 2015
�����aJ'�D
To: city of orono FEB 1 U 2U15
FROM: Loren Kohnen CON OF (°���0.;Q
RE: 2660 Fox Street
City of Orono
SEPTIC DESIGN (all tanks replaced)
1) 1-2250 split septic tank or 2-1250 tanks.
2) 1-1300 gal. pump tank.
3) Two (2) pressurized mound systems (2 rock beds) .
4) Upper mound 10 ' x 27' rock bed, 18" clean washed sand under
rock bed.
5) Lower mound 10 ' x 36 ' rock bed, 18" clean washed sand under
rock bed.
6) Three (3) jar tests on sand for each mound system.
7) Alarm is recommended inside home.
8) As-built by contractor.
9) All sites fenced and inspected before any permits are granted.
INSPECTIONS:
1) Fencing.
2) Tanks and rough-up.
3) Sand, rock and piping.
4) Final pump and alarm test; recommend alarm be inside home; gate
valves test for equalizing pressure.
5) As-built by Contractor.
LR: jg
Box 248, Loretto, Minnesota 55357