Loading...
HomeMy WebLinkAbout2000-P02644 - mechanical � "- � � PERMIT / CITY C�F ORONO 2750 Kelley Parkway - PO Box 66 Permit Number: Po2644 Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits (612) 249-4600 Date Issued: �itoioo SITE ADDRESS: 262o Fox st WAYZATA,MN 55391 P ID: 04-117-23-42-0010 DESCRIPTION: Proposed Use: Residential Permit Class: General Permit T e: Mechanical Permits Permit Sub-type(s): Heating Systems YP Air Conditioning DETAILS: Approved per resolution #: Separate permits required: NOTICES/REMARKS: FEE SUII�MARY: Permit Fee: $ 52•�4 Valuation: $ 4,219.00 State Surcharge Fee: $ 2.11 Misc. Fee: $ 1.50 TOTAL FEE: $ 56.35 APPLICANT: Ditter Inc OWNER: D M JAFFRAY&M B JAFFRAY 820 Tower Dr 2620 FOX ST Hamel,MN 55340 WAYZATA MN 55391 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. ✓� Z Q'�-�'- C�{�r`� �' �'�'� APPLICANT PERMITEE SIGNATURG ISSUED BY SIGNATURE Copies: City,Applicant,Assessor, Finance Page 1 : i � J � CITY OF ORONO APPLICATION FOR MECHAIVICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a pernut will be issued within 2 working days. 2. Pernut cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs - Complete calculations, details and specifications are required for each heating, ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected (rough-in and final). Call 473-7357. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 473-7357. Please check one: N�e ' Addition Repair i/"Replace ��'Residential Commercial JOB SITE: '�� �� S� Zip. �.�J� ;, Owner's Name: C-i� 7�2.� '� �;�Z� Telephone Number: '��"'�- "�jJ Mailing Address: �� ��7� 5�_� �- City: c:✓<:���-� ZiP - Contractor's Name: / 2 ,��x {--� Telepk�one Number: " 7 -- (1 S Mailing A�dress: `: �"�� %�l� �"��(� City: �," ���� � Zir: ��1`��4c> SYSTEM DESCRIPTION HEATING SYSTEMS Quantity: �� Make: �? G Model: �` ��3(�-��5� Fuel: lV��� • Flue Size: �`� Input BTUs: �- � Gv Output BTUs: /�•�'��>� CFM: 'y=C'z� COOLING SYSTEMS Quantity: � Make: ���OX Model: S27 �;� � Tons: ` 2- H. Power � # � , � WOOD BURNING EQUIPMENT Wood stove with flue Wood combination or add-on Factory fireplace with flue Factory Fireplace (s) Freestanding Masonry Wood Stove (s) Franklin, other Brand Name Model No. Mfgr's Min., Clearances, side , rear , min. flue dia. VENTILATION No. Kitchen Exhaust ducted recirculating cfm No. Bath Exhaust (must be ducted outside) cfm No. Other Fans: Locations cfm FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) Installation Removal Fuel oil: gallons underground inside outside LP Gas: gallons Other Gas opening PERMIT FEE CALCULATION 1. 1.25%o of Contract Price* or Minimum Fee ($35.00) � � �-;�L� x .0125 $ `.> � �r� _ (contract pnce) 2. State Surcharge. ** Add the State Building Code Division /) �� Surcharge to each permit. x .0005 $ ,� or $.50, whichever is greater (contract price) 3. Posta�e and Handlin� (Only mail-in applications) $ 1.50 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ � . 3� * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the pernutted work including materials, labor, profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. ** The STATE SURCHARGE is .0005 of the contract price under $1,000,000 or $.50 - whichever is greater. For valuations over $1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code, and certifies that all statements made on this application are complete, true and correct. �� , i � / Applicant's Signature: � � �� Date: (Z) GL> � Approved By: ��� i f' Date: ! �"�� I � r JAFFERY HVAC LOAD ANALYSIS for DRAPERJAFFERY ' 2620 FOX STREET ' ORONO, MN 55391 , ,I --- -- --- - ---� � � ' � � � � � � � � _ , .. a . : . ���� R��jA�N'�A[, � F��� �QA�& Prepared By: Doug Bjork Ditter Inc.,Cooling and Heating 820 Tower Drive Medina, MN. 55340 (612)478-9558 � _ _ - - - _ _- - - --- - - - - _ _ _ _ - _ _ _ _ - - - - - � �RHVAC Residential&Light Commercial HVAC Loads Program Elite Software Development,Inc. Ditter, Inc JAFFERY I Hamel,MN 55340-9691 Page 2 I _ _ _ _ _ _ - -_- -__ . - ----_ . _---_ -_ _ - ' Total Building Summary Loads � Compo�nent Area Sen. Lat. Sen. Total I i Descn tion Quan Loss Gain Gain Gain � I 3A Window Double Pane Clear Glass Wood Frame 220 11,152 0 11,312 11,312 I 10F Door Wood Solid Core & Metal Storm 63 1,854 0 477 477 I, �I 12C Wall R-11 + 1/2 Gypsum(R-0.5) 1,621 13,422 0 3,443 3,443 I 12D Wall R-11 + 1/2"Asphlt Board(R-1.3) 896 6,594 0 1,690 1,690 � 16G Ceiling R-30 Insulation 768 2,332 0 1,115 1,115 ' 21A Basemt Floor 2' or More Below Grade 768 1,696 0 0 0 � . - _- - -- - _ _ - _ ____ _ - _ _ - _ _ - _ ___ -- - - - - - - - - - � Subtotals for structure: 4,336 37,050 0 18,037 18,037 � Active People: 6 0 1,380 1,800 3,180 i I Inactive People: 0 0 0 0 0 'I i, Appliances: 0 0 0 1,?_00 1,200 � Lighting: 0 0 0 ' Ductwork: 0 0 0 0 0 I � Infiltration: Winter CFM: 307.2, Summer CFM: 92.2 283 30,163 2,188 1,967 4,155 I i Ventilation: Winter CFM: 50.0, Summer CFM: 0.0 0 4,909 0 0 0 I - - -_ _ _- _ _- . _ __ _ - - I Sensible Gain Total: 23,004 � � Temperature Swing Multiplier: X1.00 Building Load Totals: 72,122 3,568 23,004 26,572 i _ _ _ - - - - -. --- -- - ___- - - - - _ ' Check Figures I Total Building Supply CFM: 1078 CFM per square foot: 1.403 � I Square feet of room area: 768 Square feet per ton: 300.469 � - - _ _ - __ . - - _ _ __ - --__---- _ _ _ _ . _ _ _ _ . Building Loads ! _ _ __ - - - -- -- - _ --- - - - - -- ___ _ -- - --- _- i � Total heating required with outside air: 72,122 Btuh 72.122 MBH I � Total sensible gain: 23,004 Btuh 87 % I � Total latent gain: 3,568 Btuh 13 % i 'I Total cooling required with outside air. 26,572 Btuh 2.214 Tons (based on sensible + latent) i i 2.556 Tons (based on 75% sensible capacity) I � ___ ___- - ----- - __ -----. _---- --_ __ __ - _- -___ - - _ _ _ __ I i Notes I _ _ - - -_ _ _ _ - ._ -- -- - - -----___ -- -- - I� Calculations are based on 7th edition of ACCA Manual J. I � All computed results are estimates as building use and weather may vary. I, I Be sure to select a unit that meets both sensible and latent loads. ! j I � i _ - - __ - _ _ _ _ --- --- - - _ _- __ __ _ - _ _ - �I Tuesday,June 27,2000