Loading...
HomeMy WebLinkAboutseptic info _�_ //;;=O \ � � \ �:�.�:�:: . ���, ,���,�� , � ������! CITY of ORONO s` �' '' ti II Municipal Offices \'�'+� ��,��;'��J'I� '�/ , �,� �`�,�� G �� ' � ,� ��" Street Address: Mailing Address: `.��EsKp�i'� 2750 Kelley Parkway P.O. Box 66 ��___ ' Orono, MN 55356 Crystal Bay, MN 55323-0066 October 19, 2010 To: Whom it may concern From: Willie Gibbs, Building Inspector Re: 2650 Fox Street septic system I inspected the property at 2650 Fox Street on Wednesday, October 13, 2010. The house has been vacant for an unknown period of time. The current septic system did not show any signs of creating a health nuisance once the house is re-occupied. I also reviewed the site that has been staked out for the new septic system and appears to be adequate. If anyone has further questions regarding this matter please feel free to call. Sincerely, ��w _ Willie Gibbs, Building Inspector Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us � � �; , '` C I�'�' o� OIZON � , ;� � ��� �`, � '�'; � � �� I' Municipal Offices S4reet Address: Mailing Address: ���� ' ��'�� 2150 Kelley Parkway P,O. Box 66 E��I _ Orono, MN 55356 Crystal Bay, MN 55323�0066 To: The Cui-��ent Owner of Address ���' -�� �'Cr � City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the follo�vin� is kno�vn about the system. A sketch of the known components of the system is available for most properties at the Orono Citv Hall. Imminent Public Health Threat Yes =-�� No If yes, please contact the Onsite Systems ManaQer at 9�2-249-4626 �vithin 10 days of recei�t of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. Systetn Id?nti ac 1`Io�-�ompliant Yes No If yes, systein must be brouaht into compliance by: �ecember 31, 2007 December 31, 2010 � ather Septic 'g'ank(s m� out Needed �'es I�r o The City- recommends the septic tai�l:(s) arldior lift tank be serviced ancl pumped o�.lt �verv three vears. Citv records indicate the tan1:(s) were last pumped out on � - ��3 t�� . The tanl:�s) should be cleaned tl�rouQh the manhole and IlOt t�ll'011ah the inspection pipes. tlzis a11o��°s for proper cleanin�. ConZments: w• F �A A' �� '� '��S.1;�o��,p. . �l� /S�� Ii1�p�CiOi�� � "�,�a,s: l�.?tZ Ot II1S�.1zCI1nr1 _� - (�-�-. ^ 7 1:�:) 2.;.� .�c�n , — ;, ?�;� ;�,;., - 'c.'iA73it)1_�� '� �i�",{•��.. _�.. �:....1 J' _.. ,Y�li".ti.(�'.!'.—^2 0.7�i.._� �� o ��� � � 0 0 CITY of ORONO ,� . �r �., �, ti M�;��� ot��� ��� � � ��������:���� � Street Address: Maitin�Addross: ����1fEgg0��� 2150 Kelley Parkway P.O. Box 66 �_—= " Orono, MN 55356 Crystal Bay, MN 55323-0066 May 16, 2000 Keith Anderson 26�0 Fol Street Wayzata, Mn 55391 Dear Mr. Anderson: An inspection of your septic system was conducted on May 9, 2000. A summary of the inspection is below. Seutic Tank Condition l. Pumpout needed within one year(last pumpout 3/12/92). The septic system is non-compliant due to a lack of a three foot separation distance between the bottom of the drainfield to the seasonally high watertable. The three foot requirement is a State Code, not a City Code. A soil boring was conducted to determine the depth of the seasonally watertable. The septic s}-stem must be replaced no later than December 31, 2010. Enclosed is a list of state licensed septic contractors who work in Orono on a regular basis. Also enclosed is a fact sheet elplaining how a septic system functions properly. Finally, an as-built drawing is enclosed that shows the approximate location of the septic system. If you have any questions regarding this report, please contact me at the City Offices at 249-4600. R ectfu , i ' �� hris Pence On-Site Systems Manager Enclosures In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be ad�•ised that this report does no guarantee or certify the existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the s}•stem location and pumping records. Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us ;�%�,% � 0 �� 'Q" .� �� ��;"O O �`, �' , , �,�,., � ;;; CITY of URONO � , � �� ,� � �, ���,�� , � ��,,!r' Municipal Offices � ' r '` '``;,' G ' Street Address: `�5a'a4q"y6� � Mailing Address: l9 .¢,'� kEsxp 2750 Kelley Parkway P.O. Box 66 --_-- Orono, MN 55356 Crystal6ay, MN 55323-0066 To Current Owner: Address: �6 S� r°X S"�, City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMIT'Y (1-3): � I "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet ail the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requ'uement for systems installed 1996 or earlier,and which is not failing or an unminent threat to public health or safety. 3O "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may no t mee t a l l t he loca tion,d e s i g n,o r c o n s t r u c t i o n s t an�a r d s o f t h e c u r r e n t O r o n o M u n i c i p a l C o d e an d w h i cl�i s failin g for an y reason;and any ISTS with less than three feet of unsaturated soil or sand beriveen the distribution device and the luniting soil characteristics. TANK CONDITION(5-7): � Tank inspection indicates: 5 Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped ). Make sure septic tanks are pumped throu�h manhole and not through white inspection pipes. This altows for the proper cleanin� Keep water softner and iron filter discharge out of septic svstem to prolon�life of drainfield. Ask pumper to test alarm float to verifv alarm is stilt working in your house. The alarm warns owner that septaee is about to backup into basement. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION 8-10 : � 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critica]yet. 10 Drainfield is saturated and visibly dischargin�untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMMENT : ���.,�c.�-,,-e\U �S �p�- (o�-����,.-�- �-- C�v�.�- b� ���\r.c:� � �� �2.=��-Z o 10 , -� ���-c�� ��� /� 'C, Date of Inspection Matt Bolterman - Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. � �� O,•�<, o "������T-� CITY of �RUNO ���--� �,� � ��r.. � `�,, " � `:'.,� -�' F�► � ��{,p,�. '-�+�h G'ti hlunicipal Offices >r �;;:.;:?�����`,c l ,,, g�'y " Street Address: Mailing Address: ��K� 2150 Nelley Parkway P.O. Box 66 O�no, MN 55356 Crystal Bay, MN 55323-0066 95a-�yq-y5oo To Current Owner: Address: a6�� ��,X S�. . City Ordinance 199 requires that each existin�on-site sewa�e treatment system in Orono be inspected every two years. The on-site sewa�e ireatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTE�i CO�IFORI�IITY (1-31: 3 1 "CODE SYSTEl�1" An ISTS which mects aIl the location,design and construction standards of the eurrcnt Orono Municipal Codc. 2 '�CO�fPLIANT SYSTEM" An ISTS which does not meet all the location,design and canstruction standuds of the current Orono blunicipal Code but does mcet the three foot separation requirement or two foot rcquirement for systems installed 1996 or earlier,and which is not failin�or an imminent thr:at to public hc�lth or safety. O "Ir'ON-COyIPLIANT SYSTEI�i" A prohibitod ISTS;an ISTS located within a designated IQO-year flood plain,any ISTS which may or may not mcct all thc location,dasion,or conswction standards of tj�e currcnt Orono biunicipal Code and which is failing for any rcason;and any ISTS with Icss than thrct fcct of unsatuzated soil or sand between the distribution device and the limidno soil characteristics. � TANK Cn�IDITION(�-:71: J Tank inspection indicates: � Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped_ 7-3- � � ), blake sure septic tanks are pumped throueh manhole and not throuah white insnection pines This allo�ss for the proper cleanin�. 7 Inspection risers missin�tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. DRAINFIELD CONDITION(S3-1Q�: �{, � Drainfield is dry,no surfacin�evident. 9 Some evidence oFsurfacin"not critical yet. 10 Drainfield is saturated and visibly dischar�ina untreated effluent to the surface. Contact the Ciry Inspector immediately.Repairs must be completed within 90 days. CO�iENTS: pr�.�.�F �e�� �S �,c�,— eo�— 1;�,,� ��e) �'��j� ►�c �'��Fl�ce-) � ►,y I�.�� -��.o�� _ ' 4j�� —c�a` "''`�� 1 Q�2ntir.r, Date of Inspection i�iatt Bolterman - Sepdc System Insptctor Note: In tl:e evcnt that this inspecaon rcport is used to satisfy the rcquircmcnts for a mortoa;e ar otheraansfer ofproperry,be advised that this rcport does not gus���= orcertify that an eristing systcm will continue to function properly,but is mereiy an opinion ofthe adeqaary of the system undercumntconditions based on the availabie information. � �� O O ���- �I C ITY of ORONO ,����.�_ � � �� r�"`� � ��, �, �" '�,`# t4 Municipal Offices � ���,�� � �.�����'�k���^ ��'� � Street Address: Mailing Address: .9 � i���'i1� 4,'� kEggO 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 / Owner: Address: 2650 Fox St. Permit #'s: 6159, 2466 Dates: 10/27/80, 7/8/70 Contractors: Rogar Wennar, Thompson Plbg. (This is [X] an existing system ( ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. ONon-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level [� ] has or ( ] has not been identified at this time. If the saturatad soil level has not bean idantified, this classification is subject to revision.) TANK CONDITION (5-9) : 8 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. System is discharging to the surface. Tanks must be pumped out within 48 hours. � Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be um ed out and risers installed now. 9 Inspection pipe is locate over tank baffle-can not measure so iT'�s ac`cumulation. If tanks have not been pumped out within three years, they should be pumped out now. (Durinq the last saptic tank Maintenance Pumpout the tanks [ ] were or [X] were not confirmed to be watertiQht by the licansed pumpinQ contractor. If tha tanks were not confirmed to be watartight, this classification is subject to revision.) D INFIELD CONDITION (11-14) : 11 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medium COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings were performed to verify a 3 foot separation between the drainfield and the seasonal water table. The separation is 0 feet and the system is non-compliant. Repair or replacement of the septic system is required by 12/31/2007. �! �_�� � Date of Inspection Sep ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 CITY OF ORONO � O� Municipal Offices O � O Post Office Box 66 Crystal Bay, MN 55323-0066 a � ON—SITE SEWAGE TREATMENT r� � INSPECTION REPORT ti �L9kESHo��G Owner• ��1� ��C�Y� Address• ���� r�iC `ST Permit #'s: 1 Dates: �`"� ���Z�j�Contractors://Y7��1^� 7'i-,n./�r�r r ��r°yln�l� City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked betow. (This is !/]•an existing system [ ] neu construction> SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current seuage input � without discharging any pollutants into ground or surface waters. "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but uas installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface Waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system tocated within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system uith less than 3 feet of unsaturated soil or sand betueen the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has or �7�}—has not been identified at this time. If the limiting soil characteristic has not been identified, this ciassification may be subject to revision.) TANK CONDITION (5-10): Tank inspection indicates: Purtipout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help preven�_fut�u�re�_�roblems. So cumu ation in tanks is a�a cri�ic�el. Tan sc�'s�'iourd� pumpe out as soon as possibTE.---- 8 System is discharging to the surface. Tanks must be purnped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next purtipout. If tanks have not been pumped out uithin the last three years, they should be punped out now. 10 inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): D nfield inspection indicates: � Drainfield is dry, no surfacing evident. ''T2 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector irtmediately. Repairs must be completed uithin 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): �,�����\ COMMENTS: � Date of Inspection e ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the prE�nises with the system loc�tion and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner On the North Shore of Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 1335 S. Brown Rd. � � � Crystal Bay, MN 55323 473-7357 OWNER /-�r�,�rY�ft50� ADDRESS ���� �X .�h PERMIT NO.'S. DATES �����2�-�— CONTRACTORS � ��r- City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is �an existing system ❑ new construction) � 1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. �2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly; no major upgrading of the system is required at this time. ❑ 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard, or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not �❑-/Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks j]Y Cnlieic o r�m1�^ti +^ � Iflf�l!`^1PC 1MP chnulri F��_„Y. have not been pumped out within the last three years, they ed out thi n r roblem should be pumped out now. Solids accumulation in tanks is at a critical level, Tanks Drainfield inspection indicates: should be pumped out as soon as possible. �Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped Some evidence of surfacing,not critical yet. within 48 hours to elimi�ate surface discharge. ❑ Drainfietd is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe) must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) �Adequate ❑ High water table g Low Fair ❑ Lot size b9-Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑ System is causing visible surface discharge. COMMENTS: ��9J Date of Inspection eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY /Inspector's File GOLD COPY/Homeowner