Loading...
HomeMy WebLinkAboutseptic info � o� o_�, o } Y� C ITY of ORONO � ������r������ � �',, �V�`��;;��� � ,�H Municipal Offices '� �I!��,��',. ,���� G .�� �,,,�����.�g � Street Address: Mailing Address: kEggOg' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 1 Owner: /f/JS�� �h��� Address: 2240 Fox St. Permit #'s: 250 Dates: 9/29/87 Contractors: Jerry Johnson (This is [X] an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 1 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level [� ] has or ( ] has not been idantifiad at this time. If the saturated soil level has not baen identified, this classification is subjact to revision.) K CONDITION (5-9) : 5 5 Pumpout not needed at this time. Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During tha last septic tank Maintanance Pumpout the tanks [ ] were or [�J were not confirmad to be watartight by the licansed pumping contractor. If tha tanks wera not confirmed to be watertight, this classification is subjact to revision.) INFIELD CONDITION (11-14) : 11 1 Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : low COMMENTS: Please let us know if the septic tanks have been pumped since 1992 . U��� ��-� v---� Date of Inspection Sep c System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 �ITY OF ORONO � O� Municipal Offices O O Post Off�ce Box 66 :rystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT � � INSPECTION REPORT 'C�� G~ � 9kESH�4 Owner: ��A�� �Jr'��]�i���� Address: /7`Ot7L/ �dX cS !t Permit #'s: �� Dates: /�� /y�! Contractors: �P�/ . J�'�i1���1�. City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site seuage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is � an existing system ( ] neu construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current seuage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and uhich is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface Waters. 3 "NON-CONFORMING SYS7EM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system uith less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic �.has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identi ied, this classification may be subject to revision.) TANK CONDITION (5-10): Tpryc inspection indicates: (y Pumpout not needed at this time. � Solids accumulation in tanks indicates they should be p�xnped out this year to help prevent future problems. 7 Solids accixnulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. ]nspection risers (4" dia. pipe) must be installed in each tank at next p�xnpout. If tanks have not been punped out within the last three years, they should be pixnped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). 1f tanks have not been purn�ed out within the last three years, they should be purnped out now. DRAINFIELD CONDITION (11-14): D�field inspection indicates: 1 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed uithin 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): COMMENTS: � , Date of Inspection Se ic System Znspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properlyi but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the prEmises with the system locstion and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO � O� Municipal Offices O � O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON-SITE SEWAGE TREATMENT � �, INSPECTION REPORT ti ��9kESH��'�G '�' �� '(� �/ Owner: ,/�i�?11 •XJ Y�..�h Address: v��� �X J?: Permit #'s: � Dates: / O�!—t� / Contractors:,J��'1/ ��T?17SC�1� City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked betow. (This is l� an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system uhich may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. , (The limiting soil characteristic � has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identi ied, this classification may be subject to revision.) TANK CONDITION (5-10): � 7ank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids acc�unulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be purtiped out now. � Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). [f tanks have not been pixnped out within the last three years, they should be ourtroed out now. DRAINFIELD CONDITION (11-14): Dr nfield inspection indicates: 1 Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector irtmediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknoun. LIMITING SITE FACTORS Cslope,setbacks,etc.): � POTENTIAL FOR SYSTEM FA[LURE (depends on soils,water table,etc.): �y�„J CO ENTS:'� " O D1J1� �Ga I"1� !L?VL- O'� e- �P S —-� —r' . Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properlyi but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the prEmises with the system locetion and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner On the North Shore o f Lakc Misznetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 1335 S. Brown Rd. � � � Crystal Bay, MN 55323 473-7357 OWNER J����' (� ✓��►��� ADDRESS ��� / C7X S� PERMIT NO.'S. ���� DATES /'���`g% CONTRACTORS �� ' �� City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is � an existing system ❑ new construction) � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. � 2 Does not meet a�l current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major upgrading of the system is required at this time. � 3 Does not meet current City standards in many respects relating to design, construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard, or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Dces not � Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks Solids accumulation in tanks indicates they should be pump- have not been pumped out within the fast three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. � Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table and system condition) ❑ Adequate ❑ High water table � Low Fair ❑ Lot size ❑ Medium � Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑ System is causing visible surface discharge. COMMENTS: //-/-9l� � Date of Inspection eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner _o;,,,,, � � ,, ,, �o o ��,�� ��� �� ��r;��. �, ����� CITY of ORONO `� ti M�;�,� otr�� � � ��� � . . � � �.� � � � �'� � Street Address: Mailing Address: �� 9 4��' -',, ���_��gg0� 2150 Kelley Parkway P.O. Box 66 -_-_% Orono, MN 55356 Crystal Bay, MN 55323•0066 May 16, 2000 Jamie R. Johnson 2240 Fox Street Long Lake, Mn 55356 Dear Mr. Johnson: An inspection of your septic system was conducted on May 5, 2000. A summary of the inspection is below. Septic Tank Condition 1. Pumpout needed within one year (last pumpout 6/1/92). The septic system is a compliant system, meaning it meets all or most current City and State Standards. Enclosed is a list of licensed contractors who work in Orono on a regula.r basis. This list is enclosed simply for your reference in case your septic system needs maintenance in the future. Also enclosed is a fact sheet explaining your septic system and how it functions. Finally, an as-built drawing is enclosed showing the appro�mate location of the septic system. If you have any questions regarding this report, please contact me at the City Offices at 249-4600. Re ectfu , Chns Pence On-Site Systems Manager Enclosures In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be ad�•ised that this report does no guarantee or certify the esisting system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us