HomeMy WebLinkAbout2009-00625 - mechanical CITY OF ORONO PERMIT NO.: 2009-00625 2750 KELLEY PARKWAY ORONO, MN 55356- DATE �sSUED: 09/25/2009 952 249-4600 FAX: 952 249-4616 ADDRESS : 1880 FOX ST PIN : 03-117-23-42-0015 LEGAL DESC : WALDRON WOODS : LOT 1 BLOCK 1 PERMIT TYPE : MECHANICAL(>$500) PROPERTY TYPE : RESIDENTIAL CONSTRUCTION TYPE : MECHANICAL- MULTIPLE VALUATION : $ 30,000.00 NOTE: GEOTHERMAL 2 CARRIER GAS HEATING SYSTEMS 6 BATH FANS 1 FAN IN LAUNDRY 2 GASLINES APPLICANT MECHANICAL 375.00 GENZ-RYAN PLUMBING& HEAT STATE SURCHARGE MECH (VALUAT[ON) 15.00 2200 HIGHWAY 13 BURNSVILLE, MN 55337 MAIL-IN FEE 2.00 (952)767-1000 MISC FEE 0.00 TOTAL 392.00 OWNER BLUM, STEVE 1880 FOX STREET WAYZATA, MN 55391- AGREEMENT AND SWORN STATEMENT The work for which this permit is issued shall be performed according ro [he approved plans and specifica[ions,applicable City approvals,and the State Building Code. This permit is for only the work described and does not grant permission for additional or related work which requires separate permits. All provisions of laws and ordinances governing this type of work shall be compied wi[h whether or no[specified herein.This permit will expire and become null and void if construction authorized is not commenced within l80 days of the date of issuance,or if construction is suspended for a period of 180 days at any time after work has commenced. The applicant is responsible for assuring all required inspections are requested in conformance with the State Building Code.This permit may be revoked at any time for�1ue cause _ G " � riQ�' - � , . � ` / L�C Applicant Permitee Signa e Date � Iss ed,�� y Signature Date SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. ` � ' � 1 ��,� �q`�' __ FOR CITY USE ONLY ���'`���. City of Orono /� ��� P.O.Box 66 Date Receivcd: Pcrmit# �% ��� ���y, �"'�� 2750 Kellcy Pazkway �,3 ���'r � �ji Crystal Bay,MN 55323 Approved By:� Amount$: � ������,o�:-� (952)249-4600 .j -ory CITY OF ORONO—MECHANICAL PERMIT (All Commcrcial pennits must bc approvcd by the Building Official or Inspector and/or Fire Marshall) GENERAL 1NFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within two working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECENE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Desiens—Complete calculations,details and specifications are required for each heating,ventilation,humidification-dehumidification,and air conditioning installation including heat loss/heat gain calculation,design temperatures,equipment ratings and identification as to type,manufacturer and model. Data shall be presented on form provided. 4. When any new construction or remodeling is involved,a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call(952)249-4600. (24-48 hour notice required) 7. House Heating Test Record must be submitted before final. TYPE OF PERMIT Check All That A 1 �Residential �Commercial(Approval Required) ❑ New �Additional ❑Repairs ��Replace Job Site/Owner Information: . � .�T'. Site Address: t` l, �i�j:-X �-�;��- � � ' �(�,, !� r,r, . � ., .r . _ S Owner: ���� I�t��V�1�'� Mailing Address: ����. 1��;�;'� �`�--��-i�,�t� �X� r Clty: ����'� � Zlp: ������.�� Home Phone: Alternate Phone: Contractor Information: , Contractor: �: ;�.��1;�,1"1 Contact Person: '�,�';��7�1,��'�r ��.l,t�lSt Address: - � , � " g?� .`l, � �1..;=�-7``�.�`��`� State Bond#: `� � �� �,nr-� e,�� Y.� City: �`�>U+� ;-;i�'1� !� Zip:. � 7�`�Expiration Date: �-'l ���� 1 Phone: Alternate Phone: ❑ Insurance—Current: 1 . . ' ,�,, , MECHANICAL SYSTEMS BEING INSTALLED Note: All Geothermal Systems will now require a Site Plan&Review by our Building Official. IS THIS GEOTHERMAL? �Yes ❑No HEATING SYSTEMS Quantity: � Make: '��'U� t� ModeL• �7���I��'� �2� Fuel: ���1.5 Flue Size: Input BTUs: �� '�_ Output BTUs: �U�,'U Ul,- CFM: -�"� U ��. -. ;��F�1 �'_�.C_,�� COOLING SYSTEMS Quantity: Make: Model: Tons: H.Power FIREPLACES ❑ Gas Factory Fireplace Brand Name: ❑ Wood Burning Fireplace � Wood Stove Model No.: ❑ Wood Stove With Flue VENTILATION � No. Kitchen Exhaust duct recirculating cfm No. _ �yl_ Bath Exhaust(must have duct outside)_ '�(, cfm�F�?u�'� ❑ No. � Other Fans: Locations j_(�a,�,�'Y�f_� i� ����((�� �) cfm � y FUEL STORAGE (Must be approved by Fire Marshall ifproposing to abandon tank in place.) 0 Installation � Removal Fuel Oil: gallons ❑ Underground a Inside �Outside LP Gas: gallons Other: GAS LINE ONLY ❑ Outdoor Grill � Other/List What&Where:�F�• � ,'�j ��C�� � L����i� � �� ��"�����L�� L�tS�� -�(Y� �G1CQ lC�o�.� 2 � � PERMIT FEE CALCULATION(S) BASED OFF-2002 STATE STATUE ❑ Yes,this section applies The replacement of a Residential fixture or appliance that meets all three of the following requirements: 1. Does not require modification to electrical or gas service. 2. Has a total cost of$500.00 or less;excludine the cost of the fixture or appliance:and 3. Is improved,installed or replaced by the homeowner or licensed contractor. Skip next section,if this applies; Cost of Permit $ 15.00 State Surcharge $ .50 Mail-In Fee(If Applicable) $ 2.00 Total Permit Fee $ PERMIT FEE CALCULATION S -JOBS OVER$500.00 If above does not apply;follow guidelines below: 1. CONTRACT PRICE *is 1.25%of contract price with a(Minimum Fee of$50.00) � �`��1 Rtr�7 x A125$ '����•� (contract price) (mi�imum$50.00) 2. STATE SURCHARGE **Add the State Bldg Code Div. Surcharge(Minimum Fee of$.50) ��; ,_`?� ��'1.'�% x.0005 $ I � t L (contract pricc) (minimum$ .50) 3. POSTAGE&HANDLING(Only on Mail-In Applications) $ 2.00 .-�., --f���� 4. TOTAL PERMIT FEE(Add Lines 1-3 Above) $ ':�'�( '� � V' ■ * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the perrnitted work including materials,labor,profit,and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor or installations are furnished by the owner,tenant or any other party, the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. ■ **Thc STATE SURCHARGE is.0005 of the Building Department at(952)249-4600 for the price. MECHAIVICAL PERMIT APPLICATION AGREEMENT The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the State of Minnesota, and certifies that all statements made on this application are complete, true and correct. C�\\ ! �r � � ApplicanYs Signature�� �� �����t � ��-�'� Date: ���-�����`�� Reset Form 3 ' � ��. k ' � ,'� � � SANi�LE PRQJECT TITLE GEODESIGf�ERO SYSTENf A�IALYSIS �`� �� ��1 � ���� � �� Prepared For: Mr. and Mrs. S p!e Custome� 1_ Sample Drive � �Se�nple City, USA 12345 .,� Sample Heating and Cooling 555 W. Demo Road Anywhere, USA 469825 555-1212 555-1212 9l9/2009 �Carrier Sample Project Title GeoDesignEr� 9/9/20fl9 Page 1 �Project Information Prepared For: Prepared By: Mr. and Mrs. Sample Customer Sampie Heating and Cooling 1234 Sample Drive 555 W. Demo Road Sample City, USA 12345 Anywhere, USA 469825 123-321-1234 555-1212 123-321-1234 555-1212 Notes: Sample Customer Note Notes: Sample Dealer Note 'Design Data Heating Load: 180,000 Btu/Hr Heating Setpoint: 70 Deg F Htg Load Temp Diff: 80 Deg F Cooling Setpoint: 75 Deg F Cooling Load: 72,100 Btu/Hr Begin Cooling At: 70 Deg F Clg Load Temp Diff: 25 Deg F Hot Water Setpoint: 130 Deg F Sensible Cooling: 65,000 Btu/Hr Hot Water Users: 4 Continuous Fan: No Reference City: Minneapolis, MN Winter Design: -12 Deg F Annual Heating: 334.2 Million Btu � Summer Design: 92 Deg F Annual Cooling: 50.7 Million Btu Bldg Balance Temp: 57 Deg F Annual Water Heating: 22.1 Million Btu Avg Internal Gains: 28,722 Btu/Hr Daily Hot Water Use: 70 Gallons �Estimated Operating Cost Summary System Heating Cooling Hot Water Constant Total Per Cost Cost Cosi Fan Cost Month 2-5 ton split geo units. $1,550 $72 $143 $0 $1,765 $147 No Option Selected $0 $0 $0 $0 $0 $0 No Option Selected $0 $0 $0 $0 $0 $0 Comments: Utility Cost Rate Summer Winter Sample Project Note. Electric- Geothermal $/kwh .045 .045 Electric- Heat Pump $/kwh 045 .045 Electric- Furnace $/kwh 097 .097 Natural Gas $/therm 1.00 1.00 Sample Proj # Propane $/gallon 2.50 2.50 Fuel Oil $/ allon 2.50 2.50 Due to the variability of weather, system installation, and living habits this analysis is to be considered an estimate. 919/09 Carrier Sample Praject Titie GeoDesigner� 8/9/2009 Page 2 ;System Comparison Graph Annual Operating Cost $1,800 $1,620 ' $1,440 $1,260 I $1,080 II ; ------ __ _ ---- ------- �900 —---- ___ $720 $540 I � $360 $180 � $0 . �, =,�'F"—_ .� t'�' _ ��" �__ - �-- i _---- r __ ___ ----�-- ----- r ----� Heating Cooling Hot Water Fan Total � 2-5 ton split geo units. ` No Option Selected � No Option Selected 9/9/09 Carrier Sample Project Tttle GeoDesigne� 9/9/2009 Page 3 'System Summary 2-5 ton split geo units. Carrier Unit Heating Series: Carrier GT-PX Puron Carrier GT-PX Puron Total Capacity: 10 Tons Electricai Use: 24,893 Kwh Style: Two Stage-Var. Speed Average Efficiency: 3.49 COP Hot Water Generator: Yes Annual Contribution: 89 % Heating Run Time: 3,816 Hours Annual Cost: �1,120 Cooling Run Time: 497 Hours Heating Stage 1: 55 % of Htg Gas Furnace Cooling Stage 1: 100 % of Clg Fuel Use: 425 Therms Electrical Use: 106 Kwh Geothermai Source Average Efficiency: 89 % Annual Contribution: 11 % Source Type: Horizontal Closed Loop Annual Cost: $429 Soil Type: 0.75- Damp SilUClay Pipe Type: 3/4" IPS PE SDR 11 Annual Heating Cost: $1,550 Pipe Configuration: U-Tube Horizontal Bore Avg Pipe Depth: 20 Feet �ooling � � T_ _� ��___�� Bore Length: 1,705 Feet Carrier GT-PX Puron Min Freeze Protect: 5 Deg F Electrical Use: 1,597 Kwh Average Efficiency: 31.7 EER Max Source-Cooling: 74 Deg F � Avg Source-Cooling: 57 Deg F Annual Cooling Cost: $72 Avg Source-Heating: 31 Deg F Min Source-Heating: 25 Deg F Water Heating Geothermal Hot Water Generator Deep Earth Temp: 47 Deg F Electrical Use: 1,027 Kwh Surface Swing: 29.2 Deg F Average Efficiency: 4.32 COP Swing Time Lag: 35 Days Annual Contribution: 69 % Soil Conductivity: 0.75 Annual Cost: $46 Soil Diffusivity: 0.60 Loop Conductivity: 1.35 Electric Storage Water Heater Electrical Use: 2,161 Kwh Auxiliary Heat Average Efficiency: 94 % Annua� Contribution: 31 % Type: Gas Furnace Annua� Cost: $g7 Style: Ignitor-Cond-2stg-Vspd Input Capacity: 185,786 Btu/Hr Annual Water Heating Cost: $143 Output Capacity: 174,639 Btu/Hr Efficiency: 93 AFUE Continuous Fan Low Output Capacity: 113,515 Btu/Hr Aux Balance Point: 20 De F Electrical Use: 0 Kwh Water Heater Annual Continuous Fan Cost: $p Type: Electric Storage Water Heater Style: High Efficiency Efficiency: 94.0 % Total Annual Operating Cost: $1,765 Due to the variability of weather, system installation, and living habits this analysis is to be considered an estimate. 919109 � Version 8.0 rev.071103 �'�/iK.�Tl�.kl.4.fTEAx Geothermal Closed Loop Pressure Drop Calculation Worksheet � Customer: Highmark Builders Antifreeze (M,P,E or W)' m Methanol ; Address: 1880 Fox rd % Antifreeze by vol.: 20 °io ` � Address: Number of circuits: 10 'Note: M=Methanol; P=Propylene Glycol; E =Ethanol; W=Water Pump combinaton:� C (2) UP26-116 , `Note: Pump combo A= 1-UP26-99; pump combo B =2-UP26-99; pump combo C=2-UP26-116; pump combo D =3-UP26-99 , ; 1. Unit#1: 4 (enter code from below) TT_064 5 tons gpm 15 ' Unit 11.0 ft. of head x 1.01 Antifreeze corr.fact.= 11.09 ft. of hd. � 1" Hose kii 10 ft. of hose* x 14.27 ft. of hd/100 ft. = 100= 1.43 ft. of hd. 1-1/4" Inside Piping 10 ft. of pipe*x 4.40 ft. of hd/100 ft. = 100= 0.44 ft. of hd. ' (Unit to Flow Contoller) Total Unit#1: 12.96 ft. of hd. 2. Unit#2: 4 (enter code from below) TT_064 5 tons gpm 15 � Unit 11.0 ft. of head x 1.01 Antifreeze corr.fact. = 11.09 ft. of hd. 1" Hose kit 10 ft. of hose''x 14.27 ft. of hd/100 ft. = 100= 1.43 ft. of hd. 1-1/4" Inside Piping 10 ft. of pipe'`x 4.40 ft. of hd/100 ft. = 100= 0.44 ft. of hd. (Unit to Flow Contoller) Total Unit#2: 12.96 ft. of hd. Unit total (largest of totaf Unit#1 and Unit#2 -- Units must be piped in parailel): 12.96 ft. of hd. A 3. Inside Supply& Return Piping (Flow Controller to wall penetration): Pipe size: 1.25 in. Total gpm: 30 (Design flow rate) 0 ft. of pipe'`r. 14.78 ft. of hd/100 fl. = 100= 0.00 ft. of hd. B 4. Outside Supply& Return Piping (Wall penetration to header): Pipe size: 2.00 in. Total gpm: 30 200 ft. of pipe*x 2.17 ft. of hd/100 ft. = 100= 4.34 ft. of hd. C , 5. Circuit Piping (Use oniy one circuit if piped using parailel header system; use total pipe if series loop): Pipe size: 0.75 in. Design GPM/ckt: 3.0 Actual GPM/ckt = 2.3 gpm 1800 ft. of pipe* x 2.49 ft. of hd/100 ft. = 100= 44.73 ft. of hd. D 6. Fittings (Add 2 ft. of hd.for every 10 fittings): 10 (number of fittings) 2 ft. of hd. E 7. Total Pressure Drop (A + B + C + D + E): 64.0 ft. of hd." F Minimum system flow rate should be 23 gpm. '0° ��=-;-c���arosss-se '����� ' 2-Grundfos 26-99 � 8. Determine Pump Sizing Curve Coordinates: 90 ��s,�,em��rye--> Tot. gpm (3 gpm/ton) = Q1 30.0 x� ��2-Gruntlfoss26-116 80 Tot. pres. drop (Ft hd)= h1 64.0 y Point A = ��3-Grundfos26-99 ; Tot. gpm x 2/3 = Q2 20.0 x 70 � � LL PD=(Q2^2)(h1)/(Q1^2) h2 28.5 y Point B bo 30 Tot. gpm x 4/3 = Q3 40.0 x PD=(Q3^2)(h1)/(Q1^2) h3 113.8 y}Point C so - 40 9. Plot system curve & determine which Flow - Controller wili produce the desired flow rate. 30 + 20�+ . Pump Sys C = 23 gpm (to the nearest gpm) Zo , '�� � 10. Verify circuit Reynolds number: 2593 �o (Should be 2,000 or greater) Flow Rate(US gpm) 11. Calculate the amount of antifreeze needed: ° o O N O tp W O N ' ' ' N N O t0 Op O � � N �v eV N e0 (Pipe size: 0.75 ) 3600 tot. feet* x 2.8 volume/100 ft. = 100 = 100.8 gallons (Pipe size: 1.00 � 20 tot. feet* x 4.5 volume/100 ft. = 100 = 0.9 gallons (Pipe size: 2.00 � 200 tot. feeY' x 17.0 volume/100 ft. = 100 = 34.0 gallons (Pipe size: 1.25 ' 20 tot. feet* x 8.3 volume/100 ft. = 100 = 1.7 gallons Notes: 1) Use decimal number for pipe size(e.g. 3/4"=0.75) Total fluid in loop: 148.4 gallons*'` � 2)Volume/100 ft. is shown for PE pipe only. % antifreeze X 2�% by VOI. 3) Use 1" pipe for rubber hose. TO121 8f1tIf�88Ze f2q.: 29.7 gallons 12. Determine Flushing Requirements. Flushing requirements: 40 gpm @ 114 ft. hd. tnter tt.ot pipe in ootn oirecuons. incivaes coax t�nusn can. � , Wel] Log Report - 00100240 Page 1 of l Minnesota Uni ue Well No. MINNESOTA DEPARTMENT OF HEALTH County Hennepin WELL AND BORING EntryDate oe�24�tsst 100240 �uad Excelsior Update Date 09/11/1991 �uad ID 105A RECORD Received Date Minnesota Statutes Cha ter 1031 Well Name ERIC SMITH Well Depth Depth Completed Date Well Completed Township Range Dir Section Subsections Elevation 942 ft. 7.5 minute 127 ft. 127 h. 0 5/1 711 9 7 6 117 23 W 3 CDAADA Elevation Method topographic map Drilling Method -- (+l-5 feet) Well Address Drilling Fluid Weil H drofractured. ❑ Yes 445 BROWN RD S Y ° ❑ No ORONO MN From F�. to Ft Use Domestic Geological Material Color Hardness From To Casing Type Joint No Information Drive Shoe? �I Yes ❑ CLAY YELLOW 0 �� No AbovelBelow 0 ft. CIAY BLUE 17— 26 SWAMP SAND 26 30 Casing Diameter Weight Hole Diameter GUMMYCLAY BLUE 30 112 q �n.to 127 ft. Ibs./ft. CLAY 8 GRAVEL GRAY 112 116 DIRTY SAND R RY 116 127 0 en Hole 6om ft. to ft. Screen YES Make JOHNSON Type stainless steel Diameter SIoUGauze Length Set Between � r ! 4 18 8 0 ft. and ft. ,r �' �. ' � , '!, � ��s—_.�,_.-,R_�.�..�. �,w�_a-�.�.. Static Water Level }`} �` � !� 112 ft. from Land surface Date Measured 05I1711976 �...,�� PUMPING LEVEL(below land suRace) ���� � i'� 0 ft after hrs. um ina 30 m. � � � �� ��:� v� � � � � Well Head Completion ��,a � Pitless adapter manu(acturer �dodet 1 L�Casing Protection � 12 in above grade C At-grade(Environmental Welis and Borings ONLY) N 0 R E M A R K S Grouting Infortnation Well Grouted? ❑ Yes ��� No Located by: Minnesota Geological Method: Digitized-scale L24,000 or larger Survey (Digitizing Table) Unique Number Input Date: O1I01/1990 Nearest Known Source ot Contamination Verification: Address verification teet _direction _type System: UTN-Nad83 Zone15. X: 454744 Y: 4979804 Meters Well disinfected upon comptetion? �. Yes ❑ No Pump �i Not Instalied Date Installed ��lanufacturers name DEMPSTER Model number DH 75___ HP 0.75 Volts 230 Len th ot dro Pi e_ft. Ca aci 25 m T e Submersible Material Abandoned Wells Does property have any not in use and not sealed well(s)? ❑ es ��I No Variance Was a variance granted from the MDH for this well? �_i� Yes �,f No Well Contractor Certification First Bedrock qquifer QuaL Buried Ar1es Aquifer $te_vens Well Co, 27194 Last Strat Sand-red Depth to Bedrock ft. License Business Name Lic Or Reg.No Name ot Driller County Well Index Online Report 100240 Printed 9/9/2009 HE-01205-07 httn•//mrih-a�ua.health �tate Trn.us/cwi/well ln¢.a�r,?welliri=l(1(1�4� qi4i�nn4 � Well Log Report - 00563073 Page 1 of 1 Minnesola Uni ue Well No. MINNESOTA DEPARTMENT OF HEALTH 563073 County Hennepin Entry Date 08/1 211 99 7 WELL AND BORING �uad Excelsior Update Date 09127I2006 Quad ID �o5n RECORD Received Date Minnesota Statutes Cha ter 1031 Well Name WALDRON,WILLIAM Wel�Depth Depth Completed Date Weli Completed Township Range Dir Section Subsections Elevation ft. 2gg K, 233 ft. 0312311996 117 23 W 3 DBA Elevation Method Drillin Method Non-s ecified Rota Well Address Drilling Fluid We11 H drofractured? rl Yes 1860 FOX ST Benronite y - ❑ No WAYZATA MN 55391 From Ft, to Ft. Use Domestic Geologicai Material Color Hardness From To Casing Type Steel(black or low carbon) Joint Threaded Drive Shoe? �' TOPSOIL BLACK SOFT 0 2 CLAY YELLOW SOFT 2 18 es � No AbovelBelow ft. CLAY GRAY SOFT 18 67 CLAY GRAY MEDIUM 67 83 Casing Diameter Weight Hole Diameter SAND/GRAVEUCLAY GRAY MEDIUM 83 g8 4 in.to 225 ft Ibs./ft 8 in.to 30 ft. CLAY GRAY SOFT 98 109 SAND&CLAY RED MEDIUM 109 114 6.25 in.to 225 ft. CLAY RED MEDIUM 114 �26 0 en Hole from 225 ft. to 233 ft. SILT RED MEDIUM 126 140 Screen Make Type CLAY RED MEDIUM 140 147 GRAVEL&CLAY RED MEDIUM 147 158 Diameter SIoUGauze len th Set Between CLAY W/GRAVEL RED MEDIUM 158 186 9 CLAY&SILT BROWN MEDIUM 186 211 GRAVEL&CLAY BROWN MEDIUM 211 218 SANDSTONE&SHALE WHT/GRN MEDIUM 218 233 __—�..�a ,,.._=t._� Slatic Water Level j.__ �4 F�--=-�T— — ,- 60 ft. from Land suriace Date Measured 0 312 3/1 9 9 6 PUMPING LEVEL(below land surface) 60 fl after 1 hrs um in 50 . .m. Well Head Completion Pitless adapter manufacWrer WHITEWATER Model ❑Casing Protection r� 12 in.above grade � Al-grade(Environmental Wells and Borings ONLY) N 0 R E M ti R K S Grouting IMormation Well Grouted? �I Yes �' No Grout Material: Bentonite irom to 45 h. 4 bags Nearest Known Source of Contamination 80_feet N__direclion Se t�ic tank/drain feld type Well disinfected upon completion7 �i Yes L; No Pump � Not Installed Date Installed 04/0111996 Manufacturer's name MYERS Model number HP 1 Volts 230 Len th ot dro Pi e 111 ft. Ca aci 25 . .m T e Submersible Malerial Abandoned Wells Does property have any not in use and not sealed well(s)? l__ es 4`I No Variance Was a variance granted from the MDH tor this we117 ❑ Yes �� No Well Contractor Certification First Bedrock Aquifer Stev_ens INell Co 27194 NEM_ITZ T, Last Strat Depth to Bedrock ft. License Business Name Lic.Or Reg.No. Name of Driller County Well Index Online Report 563073 Printed 9/9/2009 HE-01205-07 (� ���v �v� htt»•//mr�h-asliia health ctaf�mn nc/r�ui/�uPll lno acn��z,alli�—�F.2(1'7'2 nmi�nnn . I • Heat Loss Specifications Bid ID: 12346 Model: 1880 FOX ROAD BLUM RESIDENCE Builder: HIGHMARK BUILDERS Total Plan BTU's x Factor/ Efficiency = Plan Total 119,679.80 x 1.16 / 1.00 = 138,828.5 7 BASEMENT Quantity UOM x BTU's/Hour = Heat Loss Value Patio Door Area 70 Sq. Ft. 120.00 8,400.00 Door Area 0 Sq. Ft. 120.00 0.00 Window Area 0 Sq. Ft. 82.00 0.00 Low E Glass Area 0 Sq. Ft. 62.00 0.00 Rim Joist 0 Sq. Ft. 4.00 0.00 Net Frame Wall 0 Sq. Ft. 4.40 0.00 Block Wall-Grade Level 440 Sq. Ft. 10.00 4,400.00 Block Wall- Below Grade 1,128 Sq. Ft. 3.00 3,384.00 Slab Edge 29 Sq. Ft. 12.00 348.00 Floor Area 2,825 Sq. Ft. 3.00 8,475.00 Ceiling Area 0 Sq. Ft. 2.20 0.00 Skylight 0 Unit(s) 62.00 0.00 Fan 1 Unit{s) 200.00 200.00 Vent 0 Unit(s) 600.00 0.00 Fireplace 1 Unit(s) 2,000.00 2,000.00 Basement Totals 27,207.00 MAIN FLOOR Quantity UOM x BTU's/Hour = Heat Loss Value Patio Door Area 36 Sq. Ft. 120.00 4,320.00 Door Area 56 Sq. Ft. 120.00 6,720.00 Window Area 0 Sq. Ft. 82.00 0.00 Low E Glass Area 476 Sq. Ft. 62.00 29,512.00 Rim Joist 280 Sq. Ft. 4.00 1,120.00 Net Frame Wall 2,092 Sq. Ft. 4.40 9,204.80 Block Wall- Grade Level 0 Sq. Ft. 10.00 0.00 Block Wall - Below Grade 0 Sq. Ft. 3.00 0.00 Slab Edge 0 Sq. Ft. 12.00 0.00 Floor Area 0 Sq. Ft. 3.00 0.00 Ceiling Area 799 Sq. Ft. 2.20 1,757.80 Skylight 0 Unit(s) 62.00 0.00 Fan 1 Unit(s) 200.00 200.00 Vent 1 Unit(s) 600.00 600.00 Printed By: CHRIS FRIEND Page 1 of 3 Date Printed: 9/17/2009 4:49:26 PM Fireplace 3 Unit(s) 2,000.00 6,000.00 Main Floor Totals 59,434.60 SECOND FLOOR Quantity UOM x BTU's/Hour = Heat Loss Value Patio Door Area 0 Sq. Ft. 120.00 0.00 Door Area 0 Sq. Ft. 120.00 0.00 Window Area 0 Sq. Ft. 82.00 0.00 Low E Glass Area 271 Sq. Ft. 62.00 16,802.00 Rim Joist 252 Sq. Ft. 4.00 1,008.00 Net Frame Wall 1,997 Sq. Ft. 4.40 8,786.80 Block Wall-Grade Level 0 Sq. Ft. 10.00 0.00 Block Wall - Below Grade 0 Sq. Ft. 3.00 0.00 Slab Edge 0 Sq. Ft. 12.00 0.00 Floor Area 210 Sq. Ft. 3.00 630.00 Ceiling Area 2,187 Sq. Ft. 2.20 4,811.40 Skylight 0 Unit(s) 62.00 0.00 Fan 5 Unit(s) 200.00 1,000.00 Vent 0 Unit(s) 600.00 0.00 Fireplace 0 Unit(s) 2,000.00 0.00 Second Floor Totals 33,038.20 PORCH/4 SEASON ROOM Quantity UOM x BTU's/Hour = Heat Loss Value Patio Door Area 0 Sq. Ft. 120.00 0.00 Door Area 0 Sq. �t. 120.00 0.00 Window Area 0 Sq. Ft. 82.00 0.00 Low E Glass Area 0 Sq. Ft. 62.00 0.00 Rim Joist 0 Sq. Ft. 4.00 0.00 Net Frame Wall 0 Sq. Ft. 4.40 0.00 Block Wall-Grade Level 0 Sq. Ft. 10.00 0.00 Block Waii- Below Grade 0 Sq. Ft. 3.00 0.00 Slab Edge 0 Sq. Ft. 12.00 0.00 Floor Area 0 Sq. Ft. 3.00 0.00 Ceiling Area 0 Sq. Ft. 2.20 0.00 Skylight 0 Unit(s) 62.00 0.00 Fan 0 Unit(s) 200.00 0.00 Vent 0 Unit(s) 600.00 0.00 Fireplace 0 Unit(s) 2,000.00 0.00 Porch/4 Season Room Totals 0.00 BONUS ROOM Quantity UOM x BTU's/Hour = Heat Loss Value Patio Door Area 0 Sq. Ft. 120.00 0.00 Door Area 0 Sq. Ft. 120.00 0.00 Window Area 0 Sq. Ft. 82.00 0.00 Low E Glass Area 0 Sq. Ft. 62.00 0.00 Printed By: CHRIS FRIEND Page 2 of 3 Date Printed: 9/17/2009 4:49:26 PM Rim Joist 0 Sq. Ft. 4.00 0.00 Net Frame Wall 0 Sq. Ft. 4.40 0.00 Block Wall-Grade Level 0 Sq. Ft. 10.00 0.00 Block Wall - Below Grade 0 Sq. Ft. 3.00 0.00 Slab Edge 0 Sq. Ft. 12.00 0.00 Floor Area 0 Sq. Ft. 3.00 0.00 Ceiling Area 0 Sq. Ft. 2.20 0.00 Skylight 0 Unit(s) 62.00 0.00 Fan 0 Unit(s) 200.00 0.00 Vent 0 Unit(s) 600.00 0.00 Fireplace 0 Unit(s) 2,000.00 0.00 Bonus Room Totals 0.00 Printed By: CHRIS FRIEND Page 3 of 3 Date Printed: 9/17/2009 4:49:26 PM - ' Cooling Data Sheet Bid ID: 12346 Model: 1880 FOX ROAD BLUM RESIDENCE Builder: HIGHMARK BUILDERS Total Sensible Heat Gain: 54,226.10 Total Latent Heat Gain: 10,877.20 Total Heat Gain: 65,103.30 WINDOWS - No Shade Description Sq. Ft. Glass Type Multiplier BTUH Heat Gain Amt N 0.00 0.00 0.00 NE & NW 0.00 0.00 0.00 E&W 0.00 0.00 0.00 SE & SW 0.00 0.00 0.00 S 0.00 0.00 0.00 No Shade Total 0.00 WINDOWS - Inside Shade Description Sq. Ft. Glass Type Multiplier BTUH Heat Gain Amt N 0.00 0.00 0.00 NE& NW 0.00 0.00 0.00 E &W 0.00 0.00 0.00 SE& SW 853.00 Double 39.00 33,267.00 S 0.00 0.00 0.00 Inside Shade Total 33,267.00 Doors Description Sq. Ft. Multiplier BTUH Heat Gain Amt Solid Wood 0.00 0.00 0.00 Solid Wood '* 0.00 0.00 0.00 Metal Urethane 0.00 0.00 0.00 Metal Urethane " 56.00 3.80 212.80 Doors Totals 212.80 Frame Walls Description Sq. Ft. Multiplier BTUH Heat Gain Amt No Insulation 0.00 0.00 0.00 R-11, 3" Insulation 0.00 0.00 0.00 R-13, 3-1/2"Insulation 0.00 0.00 0.00 R-13 + 1" Polystyrene 0.00 0.00 0.00 Printed By: CHRIS FRIEND Page 1 of 3 Date Printed: 9/17/2009 4:50:06 PM R-13 + 1/2" Polystyrene 4,089.00 1.30 5,315.70 Frame Walls Totals 5315.70 Masonry Wall Above Grade Description Sq. Ft. Multiplier BTUH Heat Gain Amt No Insulation 0.00 0.00 0.00 R-5, 1" Insulation 0.00 0.00 0.00 R-11, 3" Insulation 0.00 0.00 0.00 R-19, 6" Insulation 440.00 0.80 352.00 Masonry Wall Above Grade Totals 352.00 Ceilings Description Sq. Ft. Multiplier BTUH Heat Gain Amt No Insulation 0.00 0.00 0.00 R-11, 3" Insulation 0.00 0.00 0.00 R-19, 6" Insulation 0.00 0.00 0.00 R-30, 10"insulation 0.00 0.00 0.00 R-38, 12" Insulation 2,986.00 1.10 3,284.60 Ceilings Totals 3284.60 Floors Description Sq. Ft. Multiplier BTUH Heat Gain Amt No Insulation 0.00 0.00 0.00 Carpet Floor No Insulation 0.00 0.00 0.00 R-11, 3" Insulation 0.00 0.00 0.00 R-19, 6" Insulation 0.00 0.00 0.00 R-30, 10" Insulation 210.00 0.60 126.00 Floors Totals 126.00 Infiltration/Ventilation Description Sq. Ft. Multiplier BTUH Heat Gain Amt Infiltration 0.00 0.00 0.00 Mechanical Ventilation 394.00 22.00 8,668.00 InfiltrationNentilation Totals 8668.00 Internal Heat Gain Number of People 5 x 300 1,500.00 Kitchen Allowance 1500 Duct Gain R-4, 1" Flexible Blanket Insulation: Add 15% (.15) 0 R-7, 2" Flexible Blanket Insulation: Add 10% (.10) 0 Printed By: CHRIS FRIEND Page 2 of 3 Date Printed: 9/17/2009 4:50:06 PM � Latent Load Latent Load-Infiltration 0.68 x 35.00 Grains x 394.00 Infiltration CFM = 9,377.20 Latent Load-Ventilation 0.68 x 0 Grains x 0 Ventilation CFM = 0.00 Latent Load-People Number of People 5 x 300 1500 Printed By: CHRIS FRIEND Page 3 of 3 Date Printed: 9/17/2009 4:50:06 PM D�AT� TIME V CITY OF ORONO CALLED IN �Z-`^ � INSPECTION NOTIC��z� SCHEDULED /z' 09 � PERMIT NO.o?G�9 COMPLETED ADDRESS ���b � � OWNER CONTR. ��Z- Q�� TELEPHONENO. �ISZ � 7 `D�D � DESCRIPTION `� �L��� � � ❑ FOOTING ❑ MECHANICAL RI ❑ EXCAV/GRADING/FILLING Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ LAKESHORE/WETLANDS y ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ TREE REMOVAL Z ❑ WALL BD. ❑ WATER HOOK-UP ❑ SITE INSPECTION Q ❑ FINAL ❑ SEWER HOOK-UP ❑ PROGRESS � ❑ DEMO-SITE ❑ SEPTIC MAINT. ❑ COMPLAINT � ❑ DEMO-FINAL ❑ SEPTIC INSTALL. ❑ FOLLOW-UP _ ❑ PLUMBING RI ❑ SEPTIC FINAL ❑ HARD COVER REMOVAL J ❑ PLUMBING FINAL ❑ FOUNDATION/REMOVAL � OWNERICONTRACTORTOMEETYOU: YES O � COMMENTS: � w 0. � � O a � O � � r � ��__ _ Q � _ Z W � W � � d WORKSATISFACTORY:PROCEED C� PROJECTCOMPLETE � ❑ ORRECT WORK&PROCEED C ISSUE CERTIFICATE OF OCCUPANCY W O ❑ CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORECOVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. O PHOTO TAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR �CITATION ISSUED ❑ INSPECTION RE�UIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 2a hours in advance. (952� 249-46�0 OwnerlContractor on s'�te;7 Inspector. w ` White Copyllnspector's File Canary CopylSite Notice __ � �g� �� ��e�- ,---- .�r , -, . � � , � � � ` �. � � _ _ �� �� , � V � �M ��-"I ,. _- - � a�— - - f ^- ... �-`--- ---�-�__ --�---- ��-- / i��� i � _ ___---.----_=---- - � - — �..._Edga ol tle neate�- / / I� 1 I � � ` � ` -�� I - - ------ - \ � - _ � � Y � �� , � l� zz �� . �W ' ' � '' f �Yr ,' ( / . _ . andby_SE-,�� _N 89'S9'44"E 1005. • __ _ � �, g :��3 J � -� --- _ - --- - --- - - -- -- -- - - - - _ - -- i U i' i� 1 r �� S� f- • r — � � c� - - � -� - -- - - �t,��--�c, -- __..�oasF'-------�--� �` �7 �� _ - � ' r / 11J � uj`n �\ n o -- --- - -- ^ � __ - r -- r- -�r �-�--- —���-{7�� � � �" g g � � RA � D .� - —�------�- =_�---- / � �� ` � � / � � X -�- �.` �� �\ l � I � �. �� . � BUII. INC / �-/ �\ I ���� Q tn Q ✓" i � s \\ � � �.� r��� �� �1 / � I,+ ; / .� _,� `�\5[n ;,cT....4., ���� .,� ,,tt �� � U o �LL �'�E �� �, �'G. \�_ _ � �� � J r J� 1 f� \ � '/ , UNE' ( ��50 h �3p � � � �ii O , �6�� �� � � `--- �� �,, �' � ' � ' � � � � � `� - _ - `�`; � � � f /� � l ���4 � > � ,� / d�l �fo \� \MANACE�.�� I � 1 . \ I ACKfOP � �� a � / � /' RI`EWAY \ ,-_� i� \ \�°� � �I I l, j'Vl.� � � /� ��� �i� � \\�`�'��SE7BnCK �` `\ ��L rt \n j ' _1�'I ' / i � � \ �1. � �� �: i ��\ BUFFER -�--r\�i` \'% �� � �,� � / f : n.�'c � n N V / 50 ' - ._'' - 5;°,� �p� � .,� (� �� � o l �- - - -\�� :� ���\ ���' �/� � J � p ���� `, � �\ '� o!f � o� � <<� �\ �. � � �, oocsm � �\, P ��='IX..V'� r- � � � r �9 ° �ppit� LACKTOP � \ 1 \r � _ �,� � � ��� � � ,> ex�sT�v^, ; � (' � � / \ I ` \ � w J uNi +I ��� _._.) ��� Sso��\�����\ i/ ; � I r� � � H�XJSE i880:�a�- DRIvEy�r\ __ \ `I /.� �..\ w O o� � f. o - �...�..__.-�\--� l ' J � �._ _ .___..... ._ ... _ � � � ACKTO � , �., y� `a „ '`R�., � �l l 1� \ W 2 _ � k� '� � \ � \ � IVEWAY t � � ��/ � l �` �1� �, � �. . j�`� Y %� � � � ' \ \\\\� \\ \ ' -- I �' _ -- � rsaNAC� � � ��=-�"v E�� ��\ � � � \ '\\� ROVOSFD''� � 'J ��` �r r. � _ Z W z a � i ,�'lETLF�lD \���� i�\�S�J��_ � ,\\\��� \ \��` �z (�/`W>��� �v� �-' � U �a �,� � ZB� ii � \F �\ --B�FE� --sZs'p' rI�\��\� \�\\� � .\ \ �o�� �/ �� �-'--- --- = � � $' � 30 \ � �---- - - ---� -�--�_ . � . 1 \$ ��— �� \ �\ \ � vsb- •' i � � _. _. \1 N�Y E��i._\ \\��.� � �� ��\� � '---osr�'�� � ��K��i/ �-'" J � f � II i I � `\ \ �/� �����` � \���, ��.+a�__�>��j.`9� � ?-- — -- — - ` � � -�— \ � � � l `\1 1 \ \\�' � '96��yV`� �n����E�' .l� y� I ' ��� \ � I , � � '46Y EA'7 /i/ � � 1 � o 0 0 � �.� I � `,� ��� \�� G I ��/��� �•-"`�� � l i� � �\� f \� � a�''� ~ ° � " i� � � �` .t-`�1� �,,,� 1 ' / i� �� � � `' �� r I � � � ,n� ` , - �, � �, \ ` \ �� � PRESERVE �-'� ` ..�:'Y \ �\ �1 �' � I �/ /� a�uc;ov � =-, � � �._.i ` .�I�� , r � wE r�A�. � � i � �,.,,�' � � 1 � i : ���. — i_- �, a � � I , � � � �, �\ � � ��r' ,��1 1 i i ( � � � -� ��� i ; o w� , � � � i � i �5� � , '� r ,�. N�,g ,��z,, - ` f � i I � \ . /�/ �'� �lp ��H�j�� °�_�.4 �'e� .� s �,-,%" � � ' , 1 \ � �,ti � � ' "'� Q , \�i \ //i� �rv-yti. \ �''°'�','� 1 �' � � ¢=� •�,� /�' ` '� i� � �� ti'° �'6 .. ",��RomoN� o��wi� i \ � O 1 \ \ , �, ��� 2\ � i/� � % f� � �>�c ti : � ---�� � � �� � �y/^�\.. / �s ��� `: ,,j:� ��' Y 1 � � /��%� ' ° � >>o ` 6� ��� 1 � \� � �'�'" ��.� � � � �''� � ^ p � ' I � Edge of del�nealad � a ' 0 ` �"" �� � � �y� wEannds by S E R ��y;� ,�,� ,��- �� � r��( I � � o / r �I ! � / i { 1 / 1 \ �.6 - 6 ����� �, '' �` _ ___ — ��,,� ;- sj' ,- ,� � ,� �� � � ; r; � � � � E : ,° z ' /- � \_ / ,��,i�_�'� �J- � � `�� � � +� '' \� �b '"� ?`° S�- �� I , � y � p .��� N w\`� �j�� /�`r i�/.��.. `a,�� � .� . �� �� �e �1� r � t � 1 .�,�',�I j ,^'� Q0•�� ��11. - 66� ' � M1 � �II �� . �' i O � � / ��� \ ab �JJBL. OADS �, �/ // \ ''/ � � I � w v�� y ,�� � 0�� 4p\/ S.$t -�CRESDRY� �/ a?! i� , �ERTiFi�/�YE C)F SURVEY t�0�, , �� o � obao v m �n p jl /�'ti `.��� 5.16+-ACRESN/ET � , � �/ N 4W �. � / � \ � \� � \ � r, 4.61�-ACRE9URY � �i R ��� _ycr a��e � a � i i � \�!`_/ CONPGUOUS 1?` � �K' V�� �\�'- - 7� � o � �- �—�,� ���.��-�- ;f ��� STEVEN M — _� �G�� Z�, r\\ (�� �- -��' - ,' / --�` � waWe �� � ,��o ,��ti,` � � �--� � � OF LOT 1, BLOCK 1, W�ALDRON W40DS �E 30�� --o� _-�r— ��o€ 3 (;�%�,;� ���, y �sy'�' �y,� �a�d. ����. --� , s HENNEPlN COUNTY, �VIINNESOTA , ��� ���� . ' \i� '� '� we�and by S E ' �o o ,� � ;��n�1�+ r � ,� ��y � � A / zo<� 4�, � �a< � �hit � �� r�.o�' ��` \ � ' �re` �0 ' „�-o..� � �y i r , � ; �_� I � �, � g � � I � U l 1 �l �u J � �� �O ti / � � �` -�„e 6 ��lO�T a r � � � << � � -� � '� y � � / ! �/" ' \ t •�' `� '6 �_ � 6 .,s� J , =a��3 , � � / m \�� !� / � � o 0 �I �/ �r ! I \s' r�� �`��J V � ��.... � v � � �, '� �%i� �/,� ,'� .�\ , �--��ii , ''�`r% `��, � '< . I tl,�,i /� � / ' � c k ��'w-� � ��(�\�.+ o � i �''' � ,�� / i W r `'� � ^ r ��� ��e�� LEGAL DESCRIPTION OF PREMISES: + U"�� y � � F � �. � ����� °' �t �.�'�'� , ��1 J � s�,.�� � �,� ��t� �a�� _�9�� � �o��,ei�k�.wu�RON w000s �,... „�..�;t�� .�; � , � � ' ��,� - ,� � / — �^�..� r�� This aurvey ehows the boundaries of Ne abave descnbedl property,the � �i� / / • location of an euisting hase,shed and drivewaY b`�ereon,and lhe � �\ �.y �� � � proposed localion d lwo proDased additlons.It das not purport to shov �� 1 i Iher im ovements a enaoachments. ��� � , �;' �,/ / �#TY �F �R0�1� am° " �.� � � �. �'�`' za I � / �+�T ry� A' o : Iron marker � `�� , l -1 /� ' /� � �7l1� �"LAi'1 (3RADFNC� PLA�1-- — : �Kb��������e,m��sea��Nde��m V7� ' i 1/ � �� �-�4�?��VED - (�e� -rt�+El�n�+h- Searmgs showii are based upon an assumed dahm > i� ��'^ , .ti.,F'",e� •�`��.���� �- � `�° ❑ �'�`ri��'�� ;V,;;i�i R�`!��I�'�5 �_ -- ` � - � � p 5p 100 20m , ,��;�,� , ,-' � � ) � , � I� �s�.;�� r� ��'-" I C3„ � 3 33 � I� � I '_ j '".__ _ ------ � a I i` ; `''�.�'�_ _---9_Z5 _v% ---- -------- SCALE IN FEET � ,_ __..____�.�__..._---.�__.�....__.____� -