Loading...
HomeMy WebLinkAboutseptic info — ,i// O \ �'� �'; � � , O O �' CITY of ORONO � -, �, � `a ,, + ,� �' �C, Municipal Offices , i. . � � `'�\` G Street Address: `�5a'a4 q"�6� � Mailing Address: �'qlf�Hp4'� 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: iS6� F-ox s�� City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): � � "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of ihe current Orono Municipal Code. 2/ "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requuement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or conshuction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the disti-ibution device and the luniting soil characteristics. TANK CONDITION(5-7): � Tank inspection indicates: � Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped ). Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper cleanin�. Keep water softner and iron filter discharge out of septic system to prolong life of drainfield. Ask pumper to test alarm float to verify alarm is still working in vour house. The alarm warns owner that septa�e is about to backup into basement. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. r DRAINFIELD CONDITION(8-10): e'� 8O Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMMENTS: 1'�c �^� IUo�l� D�C_ ��� Sc �,—L- ��kS ��- �t ���Vt rc=r �fr- ��^^�c '^ry�;^ �GS'r � YQ�,•`�, �-z-�-�� �� ���. Date of Inspection Matt Bolterman - Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under cuRent conditions based on the available information. '�, 0,�. O,-::r, O -s-y�=�-� CITY of �RQNO �3 '1����;,� �+ ',�,, j`��':.� -.-�' �r„ � ,;;p,� �'��h G'ti biunicipaI offices �- •` �;�;;t�'�-��- - S � ;,�, g'� treet Address: Mailing Addressc �F.'SI30 2750 Kelley Parfcway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323•0066 95a-�4q-y600 To Current Owner: Address: I S60 Fdx 5T. Ciry Ordinance 199 requires fhat each existin�on-site sewage treatment system in Orono be inspected every two years. The on-site sewa�e treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONF'OR1�IITY (1-3): � 1� "CODE SYSTEM"An ISTS which mcets all the location,design and construction standuds of the currcnt Orono l�funicipal Code. 2 '�CO�iPLIANT SYSTEM" An iSTS which does not mect all the location,dcsio and construclion standards of the cuacnt Orono hiunicipal Code but does mcet thc three foot separation requircment or two foot rcquircment for systems installed 1496 or eulier,and which is not failing or an immincnt thrcat to public health or safery. 3 "NON-CONIPLIANT SYSTEhi" A prohibited ISTS;an ISTS locatcd within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or conswction standards of tjie cumnt Orono Municipai Code and which is failing for any reason;and any ISTS with lcss than thrce fcet of unsaNratcd soil or sand becwecn the distribution device and the limiting soil charactcristiu. TANK CONDITION(5:71: � Tank inspection indicates: � Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was Iast pumped 1 oD � ). 1�Iake sure septic tanks are pumaed throuah manhole and not throuQh white insnection pipes This allo�i�s for the proper cleanin�. 7 Inspection risers missin�tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. 8�R4INFIELD CONDITION($-1Q); Sj _Drainfield is dry,no surfacin�evident. 9 Some evidence of surfacing,not critical yet. � 10 Drainfield is saturated and visibly dischargin�untreated effluent to the surface. Contact the Ciry Inspector � immediately.Repairs must be completed within 90 days. C0�IENTS: r'`e�"�� q�c,, SeR}.� fi�,�KS IooiC ol� � -s-d a G�'1c�c / �ts��� Datc of Inspzction hfatt Boltcrman - Scptic Systcm Insptctor Note: In ihe event that this inspection teport is tued to satisfy the rcquircments for a maRgage or other transfer of property,be advised that this repaR does not guarancce arcertify that an existin;rystem will continue to function property,but is mercly an opinion ofthe adequacy ofthe system tmdereurrcnt condivarubased on the availabie infortna�ion. /'� O \ �% 7 � � O O\\. �,. ,j�,._ ,� '� CITY of ORONO � t,a ;rv ��ij Municipal Offices �.� \ � ,,�``:�G Street Address: Mailing Addross: ��� `91tEgg04'.� �2750 Kelley Parkway P.O. Box 66 __ _�� Orono, MN 55356 Crystal Bay, MN 55323-0066 May 16, 2000 Whitney MacMillan 1560 Fox Street Wayzata, Mn 55391 Dea.r Mr. MacMillan: An inspection of your septic system was conducted on May 3, 2000. A summary of the inspection is below. Septic Tank Condition 1. Pumpout needed within one year (last pumpout date unknown). The septic system is a compliant system, meaning it meets all or most current City and State Standards. Enclosed is a list of licensed contractors who work in Orono on a regular basis. This list is enclosed simply for your reference in case your septic system needs maintenance in the future. Also enclosed is a fact sheet explaining your septic system and how it functions. Finally, an as-built drawing is enclosed showing the approximate location of the septic system. If you have any questions regarding this report, please contact me at the City Offices at 249-4600. R ectful , r �� Chris Pence On-Site Systems Manager Enclosures In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be ad�zsed that this report does no guarantee or certify the existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us _ / � �� o � . C ITY o� OIZONO � � ,� � Municipal Offices Street Address: Mailing Address: ��`9 '4�'�G 2750 Kelley Parkway P.O. Box 66 kE3�10 Orono, MN 55356 Crystal Bay, MN 55323-0066 To: The Current Owner of Address l 5 � � �� � City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the followin� is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes �No If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non-Compliant Yes �No If yes, system must be brouaht into compliance by: December 31, 2007 December 31, 2010 Other Septic Tan��ump out Needed Yes No The City recommends the septic tank(s) and/or lift tanl:be serviced and pumped out every three years. City records indicate the tanl:(s) were last pumped out on � - I -C.� . The tank(s) should be cleaned through the manhole and not tluough the inspection pipes, this allows for proper cleaning. Comments: n ��z�a�f:��""�" ���"' � Date of Ins ection �� � � I sp p '�elephone(9�2)2�9-4600 � �'ax(952) 249-4616 www�.ci.orono.mn.us � o� o . o -��"� '' CITY of ORONO �� .a �'a'��f��� �► �,, � ;� �,� �F► Municipal Offices � fr,��":' ��jt'Ka�� G � � ,,,°��a a'���.� Street Address: Mailing Address: 'q�tEggOg' 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 /y� � Owner: / / l�� J� j�� Address: 1560 Fox St. Permit #'s: 3428 Dates: 11/16/90 Contractors: Sullivan (This is [� an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 1 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level [�] has or ( ] has not bean identified at this time. If the saturated soil leval has not been identified, this classification is subject to ravision.) K CONDITION (5-9) : 5 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout tha tanks [ ] were or [�] were not confirmad to be watartight by the licensed pumping contractor. If the tanks were not confirmad to be watertight, this classification is subject to ravision.) INFIELD CONDITION (11-14) : 11 1 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : low COMMENTS: ��b�/ / � /�',e'✓�" Date of Inspection S tic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510