HomeMy WebLinkAboutheat loss info LINE-HT.XLS Heat loss Master Residence Client Name: Site Address: � K�ITH WATERS & ASSOCIATES, INC. 10340 Viking Drivc Bden Prairic,MN 55344 Liccnsc 110001508 '�-���-� . Phonc(6l2)942-1060 I'aa(612)942-1058 Permitted Heat Loss Area(Sq. Ft.) x U Value = Heat Loss 1 Total exposed wall area: 6382.00 0.11 702.02 2 Total roof/ceiling area: 3355.00 0.03 87.23 Total permitted heat loss: 789•25 Heat Loss Through Wall Segments Wall Windows 1446.50 0.31 448.41 Doors 55.56 0.19 10.56 Rim Joist 597.00 0.04 23.34 Wall Framing(Average 10%) 428.29 0.11 46.10 Net Insulated Wall 3854.65 0.04 159.75 Foundation Windows 0.00 0.00 0.00 Foundation Wall Above Grade 0.00 0.06 0.00 3 Total heat loss through walls: 688.16 (If item#3 is the same as or less than item#1, then you have met the intent of SBC(c)2. Heat Loss Through Roof Skylight 48.00 0.34 16.32 Roof/Ceiling Framing(Average 10%) 330.70 0.03 9.41 Net Insulated Roof/Ceiling 2976.30 0.02 50.63 4 Total heat loss through roof: 76.37 (If item#4 is the same as or less than item#2, then you have met the intent of SBC(c)2. Alternate Building Envelope Design To utilize the total envelope system method,the values established by the sum of items#3 and#4 shail not be greater than the sum of items#1 and#2. Permitted Loss Item 1 +Item 2: 702.02 87.23 789.25 Actual Loss Item 3+Item 4: 688.16 76.37 764.53 Heat loss is acceptable 11/9/95 1 . LINE-HT.XLS Heat loss ' ' ` ' Master Residence Client Name: Site Address: = K�ITH WAT�RS & ASSOCIAT�S, INC. 10340 Viking llrivc Bdcn Prairic,MN 55344 Liccnsc#0001508 -� . Phonc(612)942-1060 Pax(612)942-1058 Permitted Heat Loss Area(Sq. Ft.) x U Value = Heat Loss 1 Total exposed wall area: 6382.00 0.11 702.02 2 Total roof/ceiling area: 3355.00 0.03 87.23 Total permitted heat loss: 789.25 Heat Loss Through Wall Segments Wall Windows 1446.50 0.31 448.41 Doors 55.56 0.19 10.56 Rim Joist 597.00 0.04 23.34 Wall Framing(Average 10%) 428.29 0.11 46.10 Net Insulated Wall 3854.65 0.04 159.75 Foundation Windows 0.00 0.00 0.00 Foundation Wall Above Grade 0.00 0.06 0.00 3 Total heat loss through walls: 688.16 (If item#3 is the same as or less than item#1, then you have met the intent of SBC(c)2. Heat Loss Through Roof Skylight 48.00 0.34 16.32 Roof/Ceiling Framing(Average 10%) 330.70 0.03 9.41 Net Insulated Roof/Ceiling 2976.30 0.02 50.63 4 Total heat loss through roof: 76.37 (If item#4 is the same as or less than item#2, then you have met the intent of SBC(c)2. Alternate Building Envelope Design To utilize the total envelope system method,the values established by the sum of items#3 and#4 shall not be greater than the sum of items#1 and#2. Permitted Loss Item 1 +Item 2: 702.02 87.23 789.25 Actual Loss Item 3+ Item 4: 688.16 76.37 764.53 Heat loss is acceptable 11/9/95 1