HomeMy WebLinkAbout2015-00934 - mechanical , � CITY OF ORONO * z 0 1 5 - 0 0 9 3 4 * 2750 KELLEY PARKWAY DATE ISSUED: 07/27/2015 ORONO, MN 55356- (952) 249-4600 FAX: (952) 249-4616 ADDRESS , : 945 FOREST ARMS LA PIN : 07-117-23-12-0019 LEGAL DESC : FOREST ARMS COUNTRY CLUB ADDN : LOT 000 BLOCK 002 PERMIT TYPE : MECHANICAL(>$500) PROPERTY TYPE : RESIDENTIAL CONSTRUCTION TYPE : MECHANICAL-MULTIPLE VALUATION : $ 12,700.00 NOTE: (1)CARRIER FURNACE (1)NATURAL GAS BOILER (1)CARRIER A/C UNIT (I)KITCHEN ECHAUST (3)BATH EXHAUST GASLINE TO RANGE AND FIREPLACE APPLICANT MECHANICAL 158.75 STATE SURCHARGE MECH(VALUATION) 6.35 WEST METRO MECHANICAL TOTAL 165.10 220 FRANKLIN ST NORWOOD YOUNG AMERICA, MN 55368- Payment(s) Minnesota State License#: mech-684939 CREDIT CARD 8702 165.10 OWNER EATON, BOB&JENNIFER 2721 COMSTOCK LA N PLYMOUTH, MN 55447- AGREEMEIYT AND SWORN STATEMENT The work for which this permit is issued shall be performed according to the approved plans and specifications,applicable City approvals,and the State Building Code. This permit is for only the work described and does not grant permission for additional or rela[ed work which requires sepazate permits. All provisions of laws and ordinances governing[his type of work shall be compied with whether or not specified herein.This permit will expire and become null and void if construction authorized is not commenced within 180 days of the date of issuance,or if cons[ruction is suspended for a period of 180 days at any[ime after work has commenced. The applicant is responsible for assuring all required inspections aze requested in conformance with the State Building Code.This permit may be revoked at any time for due cause. ��� �'�-�.,,Qi -��� �7 �oz 7�/S Applicant Permitee Signature Date Is ed Signature Date � . � F CITY SE p1YLY . ��� c�ty ocorono - �2:� .� o20/v`� G�D9�3 � O P.O.Box 66 Date Receive . ermit# 2750 Kelley Pazkway ,l Crystal Bay,MN 55323 Approved By: Amount$:�f(,J Phone(952)249-4600 Faz(952)249-4616 � � , yF � !�'�fSN�R�� CITY OF ORONO—MECHA1vICAL PERMIT (All Commercial permits must be approved by the Building Official or Inspec[or and/or Fire Mazshall) GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within two working days. 2. Permit cards will be sent by retum mail after a review is completed. PERMI'I'S ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD LS POSTED ON THE TOB SITE. 3. Mechanical Desi�ns—Complete calcularions,details and specifications are required for each heating,ventilation,humidification-dehumidification,and air conditioning installation including heat loss/heat gain calculation,design temperatures,equipment ratings and identification as to type,manufacturer and model. Data shall be presented on form provided. 4. Wheo any new construction or remodeling is involved, a separate building pernut must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-io and final). Call(952)249-4600. (24-48 hour notice required) 7. House Heating Test Record must be submitted before final. TYPE OF PERMIT (Check All That A 1 ) �Residential ❑Commercial(Approval Require�) �New ❑Additional ❑Repairs ❑Replace Job 5ite/Owner Information: Site Address: ��15 ��`��"� Ar�� �-n^� Owner: Mailing Address: City: Zip: Home Phone: Alternate Phone: Contractor Information: Contractor: �'��'>� �e��� ����^���'���� ContactPerson: ���t�'' F����k Address: ��'� F���'��-�+r ��', State Bond#: ��Gg�`�ci3`� City: ��'��''�<<� Zip:55��%� Expiration Date: �`, �`��" Phone: �5�-a�S' �3\�`I Alternate Phone: ❑ Insurance-Current: 1 ' � MECHANICAL SYSTEMS BEING INSTALLED Note: All Geothermal Systems will now require a Site Plan&Review by our Building Official. IS THIS GEOTHERMAL? ❑ Yes �No HEATING SYSTEMS Quanrity: �r �ti����(i � " 1�>� ,�C(� Make: �+"C�z� 1" �1 T�Tb� Model: �cl�f ����C�l � C�1 � G Fuei: �<i�ti;c,� ��.5 I�.t�+�.�h� G��,s Flue Size: �•� ` ,�� �i` Q�� � � � , � � Input BTUs: ������ �'� �� ou�ut BTUs: S����C� ��d�1<;�_�.T c�: 1 �l,�� COOLING SYSTEMS Quantiry: � Make: �q�<�Y' Model: �-1�i�3��t��^I�' Tons: ,�� S H. Power FIREPLACES ❑ Gas Factory Fireplace Brand Name: ❑ Wood Burning Fireplace ❑ Wood Stove Model No.: ❑ Wood Stove with Flue/Masonry VENTILATION � 6.� -3 `,�, No. � Kitchen Elchaust duct recirculating cfm � No. �_ Bath Exhaust(must have duct outside) �4 cfm No. Other Fans: Locations cfm FUEL 5TORAGE (Must be approved by Fire Marshall if proposing to abandon tank in place.) ❑ Installation ❑ Removal Fuel Oil: gallons ❑ Underground ❑Inside ❑Outside LP Gas: gallans Other: GAS LINE ONLY ❑ Outdoor Grill � Qther/List What&Where: �yn�}� 1�1�Z Q�c1�Z Z PERMIT FEE CALCULATION(S) BASED OFF- 2002 STATE STATUE ❑ Yes,this section applies The replacement of a Residential fixture or appliance that meets all three of the following requirements: 1. Does not require modification to electrical or gas service. 2. Has a total cost of$500.00 or less;excludin¢the cost of the fixture or appliance:and 3. Is improved,installed or replaced by the homeowner or licensed contractor. Skip next secrion,if this applies; Cost of Permit $ 15.00 State Sutcharge $ 1.00 Mail-In Fee(If Applicable) $ 2.00 Total Permit Fee $ PERMIT FEE CALCULATION(S)-JOB5 OVER$500.00 If above does not apply;follow guidelines below: l. CONTRACT PRICE *is 1.25%of contract price with a(Minimum Fee of$50.00) la, �o� x.o�25$ (contract price) (minimam 550.00) 2. STATE 5URCHARGE � ��_��� x.0005 $ (contract price) 3. POSTAGE&HANDLING(Only on Mail-In Applications) $ 2,00 4. TOTAL PERMTT FEE(Add Lines 1-3 Above) $ ■ * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the pernutted work including materials,labor, profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor or installations are furnished by the owner, tenant or any other pariy, the reasonable market value of such items must be added to the estimated cost or contract price for pernut fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. MECHANICAL PERMIT APPLICATION AGREEMENT The undersigned hereby applies ta the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regularions of the State of Minnesota, and certifies that all statements made on this application are complete, true and correct. Applicant's Signature: �A�% � `�'" Date: �"�� J"�� 3 �A � • _,_ _ -_ _ _ _ __ Rhvac-Residential&Light Commercial HVAC l.oads Elite Software Development,lnc. West Metro Mechanical Inc. Eaton 345 Forest Arms Lane,Orono, MN Norwood, MN 55368 page 2 Project Report _ ____- -- - _ _ - -- - -- — _ ------ General Project information `' " _---_ _ ------- --- — -- ------ ---- --- Project Title: Eaton 345 Forest Arms Lane, Orono, MN Designed By: Andrew Franck Project Date: Tuesday, April 21, 2015 _ - __ -- __ _ __ _ -__ _ - - Desi�n Data - -- _ __ -- - -_ _ __ --- - _ _ _ __ Reference City: Minneapolis/St. Paul AP, Minnesota Building Orientation: Front door faces East Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains DN Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: -11 -11.42 n/a n/a 72 n/a Summer: 88 71 44% 50% 72 30 __ -- ___ _ __ - - __ _ __ Check Figures _ _ __ _ _ _ . __-------- -- ----_. _ Total Building Supply CFM: 1,790 CFM Per Square ft.: 0.462 Square ft. of Room Area: 3,873 Square ft. Per Ton: 1,088 Volume (ft')of Cond. Space: 34,860 ----- - ----- -- - - -----__ ------ ---- -- __ Building Loads _ __-- ------- ..___ -- -- ----- _ _---- ---- --------- __ __ -- --- -- Total Heating Required Including Ventilation Air: 60,257 Btuh 60.257 MBH Total Sensible Gain: 39,090 Btuh 91 % Total Latent Gain: 3,645 Btuh 9 % Total Cooling Required Including Ventilation Air: 42,736 Btuh 3.56 Tons (Based On Sensible + Latent) Notes _ _ _ _ . _ _ ___ ----- --_---------- _ .___ __ Rhvac is an ACCA approved Manual J and Manual D computer program. --- ---- ----------- — ------ -- Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\...\Eaton New Construction.rh9 Sunday, July 26, 2015, 9:30 PM Rhvac-Residential 8�Light Commercial HVAC Loads Elite Softwa�e Development,Inc. West Metro Mechanical Inc. Eaton 345 Forest Arms Lane,Orono,MN Norvvood,MN 55368 . . Pa�e 3, _ Miscellaneous Report __ _ _ _ _ _ _ __ _ _ _ System 1 Outdoor Outdoor Outdoor Indoor indoor Grains Input Data Dry Buib Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference _ _ _ Winter: -11 -11.42 79% Na 72 n/a Summer: 88 71 44% 50% 72 29.99 _ - --- - __ _ -- --- --- Duct Sizing Inputs- - --- - ---- - - --- --- - ----- __- ----- -- --- — — --- ---- ---- ___ _ --- Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. ---- --- — ----- I Outside Air Data ; ------------ ---- _ -- ------ -__—_ Winter Summer Infiltration Specified: 0.190 AC/hr 0.100 AC/hr 103 CFM 54 CFM Infiltration Actual: 0.190 AC/hr 0.100 AC/hr Above Grade Volume: X 32.486 Cu.ft. X 32,486 Cu.ft. 6,172 Cu.ft./hr 3,249 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 103 CFM 54 CFM Total Building Ventilation: 130 CFM 130 CFM ---System 1-- Infiltration &Ventilation Sensible Gain Multiplier: 17.08 = (1.10 X 0.970 X 16.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 19.79 = (0.68 X 0.970 X 29.99 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 88.58 = (1.10 X 0.970 X 83.00 Winter Temp. Difference) Winter Infiltration Specified: 0.190 AC/hr(103 CFM), Construction: Semi-Tight Summer Infiltration Specified: 0.100 AC/hr(54 CFM), Construction: Semi-Tight i i � � i I i I � � � , i C:\...\Eaton New Construction.rh9 Sunday, July 26, 2015, 9:30 PM _ - Rh'vac-Residential&Light Commerciai HVAC Loads Elite Software Development,Inc. West Metro Mechanical inc. Eaton 345 Forest Arms Lane,Orono, MN Norwood, MN 55368 . Page 4_ Load Preview Report Has! Net ft.'� Sen, Lffi' Net' Sen, Sys' Sys' Sys Scope AED' Ton /Tonl Area Gain Gain Gain Loss: �9 Cig Ad CFM CFM CFM Bulding ____ ___ ____ __ __ _ ______ 3.56 _1,088 -3,873 39,090' __ __.. _._ ___. 3,645 42,736 60,257 . 745 1,790 1,790 System 1 No 3.56 1,088 3,873 39,090 3,645 42,736 60,257 745 1,790 1,790 Ventilation 888 2,572 3,460 4,606 Zone 1 3,873 38,202 1.073 39,275 55,651 745 1,790 1790 1-Basement 1,800 10,534 460 10,994 21,904 293 494 494 2-Main 50 593 75 668 2,325 31 28 28 3Main 533 8227 136 8,363 9,098 122 385 385 4Main 43 92 8 100 269 4 4 4 5-Main 684 9,727 132 9,859 9,473 127 456 456 GMain 443 3,471 106 3,577 4,754 64 163 163 7-Main 320 5,558 156 5,714 7,828 105 260 260 � � I � I I i i I � I I I � �il C:\...\Eaton New Construction.fi9 Sunday, July 26, 2015, 9:30 PM . __ Rhvac-Residential 8 Light Commercial HVAC Loads Elite Software Development,inc. West Metro Mechanical Inc. Eaton 345 Forest Arms Lane,Orono,MN Norwood,MN 55368 . _ _ _ Page6_ TotalBuilding Summary Loads _ _ - _ Component Area Sen lat Sen Tota( Description Quan Loss Gain Gain Gain - ---------- ---- _---- _ -- __ _ ---- 1D-cv-o: Giazing-Double pane, operablewindow, clear, 48.3 2,288 0 1,740 1,740 vinyl frame, outdoor insect screen with 100% coverage, light color drapes with medium weave with 50% coverage, u-value 0.57, SHGC 0.56 1 D-cv-o: Glazing-Double pane, operable window, clear, 438.6 20,746 0 24,090 24,090 vinyl frame, u-value 0.57, SHGC 0.56 11P: Door-Metal- Polyurethane Core 42 1,010 0 328 328 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 1671 9,014 0 1,770 1,770 cavity, no board insulation, siding finish, wood studs 1560-10sf-2: Wall-Basement, , R-10 board insulation to 966.1 6,222 0 750 750 floor, no interior finish, 2'floor depth 12F-Obw: Wall-Frame, R-21 insulation in 2 x 6 stud 292.1 1,576 0 221 221 cavity, no board insulation, brick finish, wood studs 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic 2073.3 3,441 0 2,115 2,115 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 21 B-28: Floor-Basement, Concrete slab, any thickness, 2 1800 2,241 0 0 0 or more feet below grade, R-3 or higher insutation installed below floor, any floor cover, shortest side of floor slab is 28'wide Subtotals for structure: 46,538 0 31,014 31,014 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 0 0 0 . Ductwork: 0 0 0 0 Infiltration: Winter CFM: 103, Summer CFM: 54 9,113 1,073 925 1,998 Ventilation: Winter CFM: 130, Summer CFM: 130 4,606 2,572 888 3,460 Exhaust: Winter CFM: 130, Summer CFM: 130 AED Excursion: 0 0 6,263 6,263 Total Building Load Totals: 60,257 3,645 39,090 42,736 - _ _ -__ - - __ - ------------ ---- Check Fi�ures _ _ _ - - - - -- - - --- ----- ---------- -- -------' Total Building Supply CFM: 1,790 CFM Per Square ft.: 0.462 Square ft. of Room Area: 3,873 Square ft. Per Ton: 1,088 Volume (ft3) of Cond. Space: 34,860 _ _ -- ----- -------- _- _ Buildin� Loads --------------------- _ _ ----- - - ------- ----:_� _-�_�_ Total Heating Required Including Ventilation Air: 60,257 Btuh 60.257 MBH �--iLL--�-_____-_____ Total Sensible Gain: 39,090 Btuh 91 % Total Latent Gain: 3,645 Btuh 9 % Total Cooling Required Including Ventilation Air: 42,736 Btuh 3.56 Tons(Based On Sensible+ Latent) ---_____------ ------________�__,_�--__ Notes -_ __- __ ___..- ------ ---_- _ _------------- ____---- ---- -=---------- ----- --__.� ------------ -------- Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. I I C:1...\Eaton New Construction.rh9 Sunday, July 26, 2015, 9:30 PM � Rhvac-Residential&Light Commercial HVAC Loads EIRe Software Development,Inc. West Metro Mechanical Inc. Eaton 345 Forest Arms Lane,Orono,MN Norwood, MN 55368 Page 15 System 1 Room Load Summary Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Clg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Basement 1,800 21,904 293 5-6 503 10,534 460 494 494 2 Main 50 2,325 31 1-4 319 593 75 28 28 3 Main 533 9,098 122 4-6 491 8,227 136 385 385 4 Main 43 269 4 1-4 49 92 8 4 4 5 Main 684 9,473 127 5-6 464 9,727 132 456 456 6 Main 443 4,754 64 2-5 596 3,471 106 163 163 7 Main 320 7,828 105 3-5 637 5,558 156 260 260 Ventilation 4,606 888 2,572 System 1 total 3,873 60,257 745 39,090 3,645 1,790 1,790 System 1 Main Trunk Size: 18x18 in. Velocity: 795 ft./min Loss per 100 ft.: 0.065 in.wg _ . . Cooling System Summary ___ Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 3.56 91%/9% 39,090 3,645 42,736 _ __ Equipment Data _ _ _ ___— - -- --- - __ ___ _--_ _------ -_ _ ___ __ --- Heatinq System Cooling Svstem Type: Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 0 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh C:1...\Eaton New Construction.rh9 Sunday, July 26, 2015, 9:30 PM �� �._ � C� DATE TI I RONO CALLED IN CTYOFO � INSPECTION NOTICE SCHEDULED PERMIT NO. �—�� S���3y COMPLETED ADDRESS ��� ��iv f'C_�" /��/'/�'K � f--� OWNER TELEPHONE NO.��'��� ���� CONTRACTOR ! � ����C � DESCRIPTION /�� �L1 �IC.�C%�� � � ' - lL ❑ FOOTING ❑ DEMO-FINAL ❑ SEPTIC FINAL Q ❑ POURED WALL ❑ PLUMBING RI ❑ EXCAV/GRADING/FILLING y ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL Z ❑ RADON SLAB �dECHANICAL RI ❑ SITE INSPECTION Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ RATED WALLS � ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP W ❑ AS BUILT-SURVEY ❑ SE E HOOK-UP ❑ FOUNDATION/REMOVAL _ J ❑ DEMO-SITE ❑ SE INSTALL 2 OWNERICONTRACTOR TO ME� ES_NO c�.� COMMENTS: o� a �h - ��bo r 1t.r4 ti� � 2c.�E — o ' pcx �4��h� an d`r�5,� �aow. Q.. roc.�(��Q- � ' `(i/ L � � �.S �d/lXi4� � � 0 �l W � Q z dl� c� �v� r W � W � J d o�/�TISFACTORY:PROCEED ❑ PROJECT COMPLETE w ❑CORRECT WORK 8 PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY O ❑CORRECT WORK,CAIL FOR REINSPECTION TEMPORARY V BEFORECWERING PERMANENT ❑CORRECTUNSAFECONDITIONWITHIN HOURS. ❑ pHOTOTAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR �CITATION ISSUED ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Ca�l " s ion 24 hours in advance. (952) 249-4600 Ow ontractor on site: Inspector. White Copyllnspector's File Cenary CopylSite Notice �/��� �� � / � DATE TIM � CITY OF ORONO .� cr+��eo iN 2,015 , INSPECTION NOTICE SCHEDULED �' PERMIT NO. `�� COMPLETED ADDRESS �'�-�..� �Di���C 7L ����S �f�-- OWNER TELEPHONE NO.�ti� �� ���� CONTRACTOR ���������/ /� T �=�'/ � DESCRIPTION �--�'�y� � ly ❑ FOOTING ❑ DEMO-FINAL SEPTIC FINAL Q ❑ POURED WALL ❑ PLUMBING RI ❑ EXCAV/GRADING/FILLING Q ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL Z ❑ RADON SLAB �-A6ECHANICAL RI ❑ SITE INSPECTION Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ RATED WALLS � ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP i ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ FOUNDATION/REMOVAL v ❑ DEMO-SITE ❑�SEpTIC WSTALL � OWNER/CONTRACTOR TO MEET YOU:�VES_NO c�.� COMMENTS: � W a �u/J✓J���s r�t4.-Ks- �K o - � �-�� �� �P4�� — 6� �. � 0 � D K cG G� v�� W � Q � 2 W � W � j W �SATISFACTORY:PROCEED ❑ PROJECT COMPLEfE � ❑CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY W O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORE CWERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑pHOTO TAKEN INSPECTOR WIIL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR �CITATION ISSUED ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Ca� ion 24 hours in advance. (g52) 249-4600 Owne ontract ite: � Inspector. '^' White Copyll�spector's File Cenary CopylSite Notice