HomeMy WebLinkAboutre retaining wall Christine Mattson From: Adam Edwards Sent: Monday, July 06, 2015 3:31 PM To: Christine Mattson Subject: RE: 945 Forest Arms Lane/#2015-00484 Okay stamped the plans. Adam From: Christine Mattson Sent: Monday, July 06, 2015 10:45 AM To: Adam Edwards Subject: FW: 945 Forest Arms Lane/ #2015-00484 We received an updated survey dated for the 9'4" retaining wall. Please review and provide comments. Below is the chain of emails between me and the builder for your reference. Thank you. ����W� From: Christine Mattson � \-� Sent: Thursday, June 18, 2015 2:06 PM �''� To: 'Mike Fritr � , , �,;�y� �� Cc: Melanie Curtis -�` `�`� Subject: RE: 945 Forest Arms Lane/ #2015-00484 M i ke, Your site pian has changed. A retaining wall was constructed without approval. The new wall is in a different location than the two previously approved retaining walls. We need an updated site plan to review. Christine'� From: Mike Fritz [mailto:mfritzCa�mandmquality.com] Sent: Thursday, June 18, 2015 1:50 PM To: Christine Mattson; 'Mike Fritz' Cc: Melanie Curtis Subject: RE: 945 Forest Arms Lane/ #2015-00484 The grading has not changed, only the retaining wall material. MCi�e�ri,tz Owner M & M Home Contractors, Inc. Cell—612-554-2556 www.mandmquality.com i From: Christine Mattson [mailto:CMattson@ci.orono.mn.usJ Sent:Thursday,June 18, 2015 1:49 PM To: 'Mike Fritz' Cc: Melanie Curtis Subject: RE: 945 Forest Arms Lane/#2015-00484 Mike, Thank you for the specs for the concrete retaining wall. Our building official has reviewed and approved it. You may proceed with framing. Due to the change in the retaining walls, please provided us with a revised grading plan by Monday,June 29, 2015. Don't hesitate to contact me if you have any questions. Christine'� From: Mike Fritz [mailto:mfritz@mandmquality.com] Sent: Thursday, June 18, 2015 1:24 PM To: Christine Mattson; 'Mike Fritz' Cc: Melanie Curtis Subject: RE: 945 Forest Arms Lane/ #2015-00484 Here you go! Mi�e�ri.tz Owner M & M Home Contractors, Inc. Cell—612-554-2556 www.mandmqualitv.com From: Christine Mattson [mailto:CMattson@ci.orono.mn.us] Sent:Thursday,June 18, 2015 1:23 PM To: 'Mike Fritz' Cc: Melanie Curtis Subject: RE: 945 Forest Arms Lane/#2015-00484 M i ke, Thanks for the additional information. The newly poured retaining wall is 9'4" in height. Since this is a new wall and is over 4 feet in height and was not shown on the approved pian, we must receive the specs/engineering plan for the construction of the wall before you can being to frame. Thank you. Christine"' From: Mike Fritz [mailto:mfritzCa�mandmquality.com] Sent: Thursday, June 18, 2015 1:11 PM To: Christine Mattson Subject: FW: 945 Forest Arms Lane/ #2015-00484 z Please let me know if we are good to start framing. MC�Ze�ri,tz Owner M & M Home Contractors, Inc. Cell—612-554-2556 www.mandmquality.com From: Daniel L.Thurmes [mailto:dan@cssurvev.net] Sent:Thursday,June 18, 2015 11:16 AM To: 'Mike Fritz' Subject: RE: 945 Forest Arms Lane/#2015-00484 PLEASE REVIEW. From: Mike Fritz [mailto:mfritz@mandmqualitv.com] Sent:Thursday,June 18, 2015 10:15 AM To: 'Daniel L.Thurmes' Subject: FW: 945 Forest Arms Lane/#2015-00484 Please call me. M��.e�r�tz Owner M & M Home Contractors, Inc. Cell—612-554-2556 www.mandmquality.com From: Christine Mattson [mailto:CMattson@ci.orono.mn.us] Sent:Thursday,June 18, 2015 10:14 AM To: 'Mike Fritz'; 'Jennifer Storms' Cc:Jeremy Barnhart Subject: 945 Forest Arms Lane/#2015-00484 Mike, After speaking with you this morning and consulting with my coworkers, in addition to having the surveyor show the top of foundation transition points, please also have them show top and bottom of wall elevations for the new retaining wall shown. We will need the above to approve the foundation as-built; before you may begin to frame. In the near future, please provide us with a revised grading plan due to the change in the number of retaining walls and the location for our review and approval. Thank you. Christine Mattson Planning Assistant City of Orono 2750 Kelley Parkway '! Orono II MN 55356 (physical addressJ PO Box 66 � Crystal Bay ;, MN ; 55323-0066 (mailing addressJ `�' 952.249.4620 ' � 952.249.4616 3 �! cmattson@ci.orono.mn.us � www.ci.orono.mn.us Summer Office Hours: (Monday, May 18 through Friday,August 28, 2015) Monday-Thursday: 7:30 am to 5 pm Friday: 7:30 am to 11:30 am OUR OFFICE WILL BE CLOSED: Friday,Ju/y 3, 2015 4 2013 Standarclized Concrete Foundation Dra�win�s Scope of Work: These drawings apply to the construction of cast-in-place concrete foundation walls for typical residential cases. These drawings are not to scale and all conditions are to be verified by the contractor. Means and methods of construction for shoring,water-proofing, insulation,flashing, control and construction joints, and all other non- structural requirements are to be by others in accordance with the Code and standard industry practice. These drawings are valid until the end of 2013. The drawings are to only be used by the contractor noted betow or his authorized sub-contractorslclients. These drawings are to be provided to the building inspection department as part of the permit package. Index: a� ,� �(�!/� �s �.. � � �' S1 -Scope, Index, and Certification / L �n S2-General Notes �.� �Cr ( !/� �N� �t/� P.L l� � ��' �I/ l �a �.-/ VU' S3-Step Footing Detail / S4-Frost Wall Detail -�Q /� �' �G( ( l �I"Gt l•f'1 Gr�� s S �i l� S5-Lookout Wall Detail Y� S6-Full Height Wall Detail �,�� � Materials: � Rei�forcing Steel: Grade 40(40 ksi)for#4 and smaller bars � /� ��� Grade 60(60 ksi)for#5 bars and larger Rebar Substitution Notes: 1. Two#4's bundled may be used to substitute(1)#6 and vice versa provided they are of the same grade steel. 2. For vertical bars on S6,#5's may be used in lieu of#6's at two-thirds of the noted spacing. Concrete: Mix design is to be prepared by the concrete supplier to meet the project's requirements Minimum 28 day compressive strength of 3000 psi Backfill Soil: Sand-30 psf/ft effective lateral pressure Sandy Clay(SC)-45 psflft effective lateral pressure Clay-60 psflft effective lateral pressure I hereby certify that this plan,specification,or Site Address: report was prepared by me or under my direct supervision and that I am a duly licensed Street: professional engineer under the laws of the state of Minnesota. City: �-_� �� State: MN Zip: Craig Oswell,PE(MN#42341) 12/3/2012 Oswell E�ginee�ing and Consulting, L.L.C. 1901 E Hennepin Ave,#201 -,�;�� �=4� �:�:-�. Project Name: 2013 Standardized Concrete Foundation Drawings Mi�neapolis, MN 55413 �N,; '• Description: Scope of Work, Index,and Certification Phone:612-720-463J - ;y� ���. Project# 12.100 Fax:612-886-2966 '' '', Client Name: Oscarson Masonry, LLC www.oswellec.com ''. Client Address: 12450 Count Road 32,Waconia, MN 55387 Page S1 of S6 ,� '� - �., enera o es: 1. Wall thicknesses noted are nominal unless specifically stated otherwise. Maximum tolerance is 112". 2. Maximum wall to footing centerline offset is 2". A minimum of 2"of footing is to extend on each side of the wall. 3. Place matching hooks around all wall corners and intersections for each horizontal bar. 4. Horizontal bars may be placed anywhere within the wall thickness provided 2"minimum cover is provided. 5. Bar laps when required are to be at least 32 diameters for grade 40 bars and 48 diameters for grade 60 bars. 6. Allowable bar placement tolerance is 112". Tying is not required if tolerances are met and maintained. 7. Dowels may be drilled and installed after footing pour unless otherwise noted. Vertical bars may be embedded into footing in place of dowels at the same embedment. Vertical bars and dowels do not need to align. Dowels may be bent down for safety and covering then bent back before wall placement. 8. Sill plate sections require at least two anchors with one within 4"to 12"of each end and at all corners and intersections. Walls less than 24" in length require only one anchor. 9. Anchor bolts 1/2"or larger in diameter do not require corrosion protection per IRC section R319.3 exception 1. 10. Anchor bolts may be substituted with 1l2"diameter threaded rod epoxy grouted at same spacing with 7"embed. 11. The presence of form oil on the reinforcing is acceptable for the conditions contained in these drawings. 12. Slope grade 6"minimum downward away from foundations within first 10 feet or provide Code adequate swale. 13. Do not backfill until the concrete has reached at least 70 percent of the 28 day concrete strength. Use of adequate shoring is required when the final floor and slab systems are not in place. Cold Weather Guidelines: The following information is considered to be general guidelines for the placement of concrete in cold weather conditions. It is the contractor's responsibility to ensure proper means and methods are followed and that the final in place product is adequate. 1. The contractor is to work with the concrete supplier to obtain a mix design which accounts for the conditions expected. Use of extra cement, early-strength concrete,and accelerators are recommended at temperatures below 20 degrees F. 2. Concrete is to be delivered to the site in a timely manner. 3. Placement of concrete earlier in the day to take advantage of latent heat of sunlight is adviced. 4. Do not add additional water. Using water-reducing admixtures is recommended when required. 5. Forms are to be free of snow and ice. Do not place concrete in contact with frozen ground ,snow,or ice. 6. Preheating of rebar is not required, however it is to be free of frost, snow,and ice. 7. Use of form blankets or other approved protection is highly recommended for the top of the wall at temperatures below 10 de rees F and for the whole wall when below zero degrees F. Oswell EnglneeNng anci Consulting, L.L.C. 1901 E Hennepin Ave,#201 j,��,•�` `;��:'ry} r . Project Name: 2013 Standardized Concrete Foundation Drawings Minne�polis, MfV 55413 �-, '� Description: General Notes Phone:612-720-4639 • 1� Project# 12.100 Fax:612-886-2966 �� } Client Name: Oscarson Masonry, LLC www.oswelleacom `�"• '� Client Address: 12450 Count Road 32,Waconia, MN 55387 Page S2 of S6 t �`�- • - i 12/3/2012 Adjacent steps are to be piaced no closer to either side of the beam section than twice the height of the largest step 6'-0"maximum ste (beam section) Optional controt joint each end of beam section by others (2)bundled#4 horizontal bars top &bottom w/3"min clearance extended at least 24"minimum � , beyond each end of beam section � � I I ; Maximum applied actual ; �g I Ioad=4000 plf uniform or I �E!. 12,000 pound � �� 6"minimum thick cast-in-place �� concrete foundation wall concentrated � N� � ��� I � � � HIGH FOO�ING I I �-------� ��� High footing should be placed at 1- � � to-1 (45 degree)line,if footing is ��� closer to step than this line, place LOW FOOTING �� rebar as if it was at this line as '�� � shown i FOOTING STEP �ETAIL Oswell Engineering and Consulting,L.L.C. 1901 E Hennepin Ave,#201 �#�+�.` ,��° ��:_ . Project Name: 2013 Standardized Concrete Foundation Drawin s Minneapolis,MN 55413 '� � Description: Step Footing Detail Phone:612-720-4638 '•� Project# 12.100 Fax:612-886-2966 t '� Client Name: Oscarson Masonry, LLC www.oswellec.com ��'• Client Address: 12450 Count Road 32,Waconia,MN 55387 Pa e S3 of Ss �^.,�;`'; j'-.+i. . I 12/3/2012 Wall framing by others Sill plate by others w/1l2" diameter anchor bolts wl 7" minimum embed&standard washers @ 72"o.c.max or ,,�� equivalent metal strap anchors Maximum stem height is 12" (width to match sill plate) 6"Min 6"minimum thick cast-in- place concrete wall w/ �,� optional slab ledge (1)#4 continuous horizontal bar wlin 18"of top of wall Provide frost protection per Code #4 x 2'-0"long dowels @ 72" o.c. max w/5"minimum embed (dowels are not required if wali 8"minimum thick is backfilled in equal unreinforced concrete strip alternating lifts not exceeding � footing,required width to be 24"in height) determined per Code by others WALKOIJT/ SLAB-ON-GRADE FROST WALL DETAIL Note: Maximum unbalanced fill height may be up to 36"provided the wall is at least 8"thick Oswell Engineering and Consulting,L.L.C. 1901 E Hennepin Ave,#2(F1 a,•� �' �':�. Project Name: 2013 Standardized Concrete Foundation Drawings Minneapolis,MN 55413 �= � Description: Frost Wall Detail Phone:612-720-4fr39 ` , � Project# 12.100 Fax:612-886-2966 Client Name: Oscarson Masonry,LLC www.oswellec.cam Client Address: 12450 Count Road 32,Waconia,MN 55387 Page S4 of S6 ` •' . 12/3/2012 Sill plate by others w/1l2" Wall framin b others diameter anchor bolts wl 7" g y ���°`°`"" " minimum embed&standard ___,.. washers @ 72"o.c.max or equivalent metal strap >_- --- �-.,-.�g anchors ���,� ; 6"Min 6"minimum thick cast-in- �' place concrete lookout (1)#4 continuous horizontal wall � • bar w/in 18"of top of wall � bo M Footing elevation may vary below slab,provide frost #4 x 2'-0"long centered protection per Code dowels wl 5"minimum 8"thick x 18"wide minimum embed wet set or epoxy unreinforced concrete strip grouted in place footing(16"wide minimum for maximum unbalanced 6"wall spacing: grade of 2'-6"or less),larger 36"o.c.max for sand, footing width may be 30"o.c.max for SC,& required for specific soil 24"o.c.max for clay bearing conditions to be determined per Code by 8"+wall spacing: others 4s"o.c.max for sand, LOOKOUT WALL DE�14�L 42"o.c.max for SC,& 36"o.c.max for clay Oswell Enginee�ing and Consulti�g,I.L.C. 1901 E Hennepin Ave,#201 .�,. ":�. Project Name: 2013 Standardized Concrete Foundation Drawings Minneapolis,MN 55413 �� � . � Description: Lookout WaII Detai► Phone:�12-720-4639 :. �. Project# '12.100 Fax:612-886-2966 z s Client Name: Oscarson Masonry,LLC www.oswellec.com Client Address: 12450 Count Road 32,Waconia,MN 55387 Page S5 of S6 ` ' 12/3/2012 . Wood floor&wall framing by others Connection of floor members to sill plate to 2x6 minimum sill plate w/1/2"diameter be per Code by others anchor bolts w/7"minimum embed&2" wide x'I/8"thick square or round countersunk washers or alternative anchor(Anchor bolt clearance between edge of both wall and sill plate is to be 6"Min 2.5")(see table below for spacing) Exterior top of wall may have a brick ledge provided the stem wall formed is at least 6"thick &no more than 16"high Continuous#4 horizontal bars,provide � at least(2)@ 8'-0"clear,(3)@ 9'-0" = clear,&(4)@ 10'-0"clear,At � contractor's option: The lowest wall c� horizontal bar may be omitted if(2)#4 V continuous horizontal bars are placed in the footing Cast-in-place concrete foundation wall wl#6 or #4 x 2'-0"long dowels @ 72"o.c.max w/ equivalent vertical bars 5"minimum embed placed 1.5"from inside face,see table below for spacing 8"minimum thick unreinforced concrete strip footing,required width to be determined per Code by others Footing elevation may vary below slab BASEMENT WALL DETAIL Clear H g nd Soil Type Table Notes: Nominal g� 9' 10' (1)= Unreinforced if concrete is 4000 psi or if Walt clear height is 4"less Thickness Sand SC Clay Sand lay Sand SC Clay Vertical Reba acing (2)= Unreinforced if concrete is 5000 psi or if 8" NA NA 36"(1) NA 36"(2) 36" 36"(1) 36" 24" clear height is 4"less 10" NA NA NA NA NA 36"(1) NA 36"(1) 36" 12" NA NA NA NA NA NA NA NA NA Allowed alternate anchors are: Sill Anchor Spacing MAB/ST,MASA/FA3,FWAZ,or 1/2"diameter BOIfB 72" 72" 48" 72" 48" 36" 60" 36" 24" expansion bolts w/6"min embed(install in accordance with the manufacturer's Alternate 48" 24" 18" 36" �8" 12" 24" 12" 8" recommendations) Oswell Engineering and Consulting,L.L.C. 1901 E Hennepin Ave,#201 w�•� �_`'� °:i, ', Project Name: 2013 Standardized Concrete Foundation Drawin s Minneapolis,MN 554'13 • -� } ,� Description: Full Height Wall Detail Phone:6'12-720-4639 �1 ,,� ' Project# 12.100 Fax:612-886-2966 �'i '6 Client Name: Oscarson Masonry,LLC www.oswellec.com �*, �` Client Address: 12450 Count Road 32,Waconia,MN 55387 Page S6 of S6 �_ ; 12/3/2012