Loading...
HomeMy WebLinkAbout2006-P10431 - mechanical PERMIT CITY OF ORONO 2750 Kelley F`arkway- PO Box 66 Permit Number: p1o431 Crystal�►3ay, Minnesota 55323 Permit Type: 1vlechanical Permits (952) 249-4600 Date Issued: 10/10/2006 SITE ADDRESS: 905 Ferndale Rd W Unit# Wayzata, MN 55391 P��� 02-117-23-44-0010 DESCRIPTION: Proposed Usc: Residential Permit Class: General Permit Type: Mechanical Permits Pem,it Sub-type(s): Heating Systems DETAILS: Approved per resolution#: Separate permits required: NOTICES/REMARKS: Also putting in a gas line FEE SUMMARY: Pernut Fee: $ 37.50 valuation: $ 3,000.00 State Surcharge Fee: $ 1.50 TOTAL FEE: $ 39.00 APPLICANT: Vogt Heating&Air Conditioning OWNER: John&Joan Brooks 3260 Gorham Ave 905 Ferndale Rd W St. Louis Park,MN 55426 Wayzata MN 55391 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. , ) ��� �/�'� e G'Y�C�// ��� APPLICANT ITEE SIGNA"I'URL' ISSUED BY SIGNATURE Copies: l-File(Signatures Xeguired), 1-Applicant, I-Monthly Reports, 1-Assessing,(If Septic, 1-Septic) Page l � � : f , , CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 GENERAL INFORMATION 1. You may apply for mechanical pernrits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within two working days. 2. Pernut cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTII.,YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Des�ns - Complete calculations, details and specifications are required for each heating, ventilation,humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building pernut must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected (rough-in and final). Call (952)249-4600. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call (952) 249-4600. Please check one: ❑ New .�Addition ❑ Repair ❑ Replace ❑ Residential ❑ Commercial JOB SITE: ��,s' ��rr�r� Zip: SS3�/ Owner's Name: �v/,� _ ;v�l�j Phone Number: Mailing Address: S�4-'rri City: Zip: Contractor's Name: �/uy�- �,�,��+�,�,d •',oGM.�,��fione Number: y'SZ-�Z-g��7L• ") Mailing Address: �Z� .(�;,j,,:,v �,,:� City• S�f�,,,,; ,�., Zi ' p� Ss'ya 4. 1 c � ► SYSTEM DESCRIPTION � HEATING SYSTEMS Quantity: ,.� d.��f�r Make: v;; � �� in�n; Model: �j'1')Q -� Fuel: (,'1CtS�ri c, Flue Size: Input BTUs: � �� %C(A� Output BTUs: .5 , j� . CFM: �j COOLING SYSTEMS Quantity: Make: Model: Tons: H.Power FIREPLACES GAS LINE ONLY ❑ Gas factory fireplace �Installing a Gas Line Only ❑ Wood burning factory fireplace with flue ❑ Wood Stove ❑ Wood stove with flue Brand Name Model No. VENTILATION No. Kitchen Exhaust duct recalculating cfm No. Bath Exhaust(must have duct outside) cfm No. Other Fans: Locations cfm FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) ❑ Installation or ❑Removal ❑ Fuel oil: gallons ❑ underground ❑ inside ❑outside ❑LP Gas: gallons ❑ Other Gas opening 2 , r PERMIT FEE CALCULATION(S) 2002 State Statute ❑ Yes This Section Applies The replacement of a Residential fixture or appliance that meets all three of the following requirements: 1) Does not require modification to electrical or gas service. 2) Has a total cost of$�00.00 or less; excludin�the cost of the fixture or appliance: and 3) Is improved, installed or replaced by the homeowner or licensed contractor. Skip next section; Cost of Permit � 15.00 State Surcharge $ .50 Mail-In Fee $ 1.50 If above does not apply, follow guidelines below: 1. Contract Price* is .0125% of job with a l�Tinimum Fee of($35.00) St�C7 "� x .0125 S S'�7 S U (contract price) (minimum$35.00) 2. State Surcbar�e. ** Add the State Building Code Division a Minimum Fee of(� .50) S��U'J•, x .0005 S I:S���V (contract price) (minimum$.50) 3. PostaQe and Handlina (Only mail-in applications) S 1.50 4. TOTAL PERMIT FEE (Add lines 1-3 above) � ,�,���r ���-�� *CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials,labor,profit,and other fixed costs.It is the amount to be charged to the customer for the«ork done. If any material, equipment,labor,or installation is fumished by the owner,tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes.In the event that there is a dispute on the amount of the job cost,the City may request the submission of a signed copy of the actual contract. **The STATE SURCHARGE is.0005 of the contract price under$1,000,000 or�.50-whichever is greater.For valuations over $1,000,000 call the Deparnnent of Inspectional Services for the price. T'he undersigned hereby applies to the City for issuance of a Mechanical Permit,agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code,and certifies that all statements made on this application are complete,true and correct. �� Applicant's Sia ature: � / ��y�1 Date: � �� Approved By: Date: 3 �Rhv�c-Residential 8 Light Commercial HVAC Loads Elite Software Development,Inc. j s , i Vogt Heating and Air Brooks Boathouse � ; �Minneapolis,�AJIN 55426 -- —_ -- ___ --___-_- --- Pa e 1 --------------- ----_ _,------------ ' ------ i �Tofal Building Summary Loads______ _________ ___ � I� ;�Component -- - Area Sen Lat - Sen _ Total DescriQtion Quan Loss Gain Gain Gain 3A-w-o: Glazing-Double pane low-e (e = 0.40), operab{e 91 4,244 0 5,003 5,003 I window, wood frame 11 N: Door-Polystyrene Core 21 647 0 184 184 12E-Osw: Wall-Frame, R-19 insulation in 2 x 6 stud 572 3,423 0 639 639 j cavity, no board insulation, siding finish, wood studs 16C�4: Roof/Ceiling-Under atfic or knee wall, Vented 352 681 0 302 302 Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R�4 insulation j 22D-5ph: Floor-Slab on grade, Vertical board insulation 76 3,839 0 0 0 covers slab edge, turns under slab and extends 4' ' horizontally, any floor cover, R-5 insulation, passive, ' heavy moist soil ' - - - - - - _ _ __ � Subtotals for structure: 12,834 0 6,128 6,128 People: 4 920 1,200 2,120 Equipment: 0 0 0 � i Lighting: 0 0 0 � Ductwork: 0 0 0 0 I Infiltration: Winter CFM: 11, Summer CFM: 6 1,041 129 87 216 � Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 ; _ _ - - - - _ _ _ _ _ - - -- - - - - - -- - - -- Total Building Load Totals: 13,875 1,049 7,415 8,464 Check Figures _ � Total Building Supply CFM: 347 CFM Per Square ft.: 0.987 Square ft. of Room Area: 352 Square ft. Per Ton: 439 i IVolume (ft3) of Cond. Space: 3,168 Air Turnover Rate (per hour): 6.6 I � �Building Loads -� Total Heating Required With Outside Air: 13,875 Btuh 13.875 MBH Total Sensible Gain: 7,415 Btuh 88 % ; Total Latent Gain: 1,049 Btuh 12 % Total Cooling Required With Outside Air: 8,464 Btuh 0.71 Tons (Based On Sensible+ Latent) 0.80 Tons(Based On 77% Sensible Capacity) Notes - i Calculations are based on 8th edition of ACCA Manual J. I All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. � � � i �; i f,Rh.vac-Residential 8�Light Commercial HVAC Loads EI'rte Software Development,Inc. s ; ;Vogt Heating and Air Brooks Boathouse � � Minneapolis,MN 55426 Pa e 2 -- ---- -- - --_ - - - ----- - — ---- — R�diant Floor Report �--- -- - — --- ------ —_Tubing—=_Tubing Floor Supple- ' Radiant Floor Sens. Length Length Heat mental Room Description Room Heat To Meet To Fill Output Heat I Name [Heat Output,Spacing] Area Loss Load Room Btuh Req'd , 1-Main Level In-floor slab on grade[40,4J 352 13,875 1,041 946 12,619 1,256 I I System 1 Total: 352 13,875 1,041 946 12,619 1,256 Notes ------ - --- Area values shown include only those rooms for which radiant floor properties have been entered. I I � Sensible heat loss values on this report do not include losses associated with ductwork, ventilation, winter humidification or � � hot water piping. � I Tubing lengths include only the tubing that is part of the radiant floor panel itself and not the supply and return piping to and from the manifold. Tubing lengths are calculated from the Tubing Spacing input and an assumed installed coverage area that is based on a 6-inch offset from each wall around the perimeter of a rectangular room. � The Floor Heat Output Btuh values shown are calculated with the assumption that the tubing is installed to fifl the room at j the given spacing. I If the Supplemental Heat Required is negative, the radiant floor output exceeds the sensible loss of tf�e room by the indicated amount, assuming that the tubing is installed to fill the room at the given spacing. I ,