City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below,
SYSTEM CONFORMITY (1-3): �
1 "CODE SYSTEM" An ISTS which meets all che location,design and construction standazds of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal
Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or
an imminent threat to public health or safety.
3 NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standazds of the current Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-71:
Tank inspection indicates:
Pumpout not needed at this tune.
6 eptic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped 1�' "�—Q �� ).
Make sure sentic tanks are uumaed through manhole and not through white inspection nines. This allows for the
proaer cleaning. Keep water softner and iron filter dischar�e out of seutic svstem.
7 Inspection risers missing-tanlcs could not be inspected. Inspection risers(4" dia.pipe)must be installed in each tank, If
tanks have not been pumped out within the last three years,they should be pumped out now.
INFIELD CONDITION 8-10 : �,
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing, not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the�ity Inspector
immediately.Repairs must be completed within 90 days.
COMMENTS: r�;n�•-cIJ '�S P,c��- �� 1:�.�fi c}— �vJ� �` ;�{ I�,c��
b-Z ��L-�3� - "Lti`c , pu ^-I� S�G��-� ��,r�l� sv�.,.�.c� Zc�o '�.
� '1L--J� �.�� �cl
Date of Inspection Matt Bolterman - Septic System Inspector
Note: In the event that this inspecdon report is used to satisfy the requirements for a moRgage or other transfer of property,be advised that this report does not guarantee
or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
Telephone(952)249-4600 • Fax(952)249-4616
www ri nrnnn tnn nc
� � °�
� o. o
-�� � CITY ONO
� ����=�-� of �R
,� „�� '�:��;? p,,
'�+�.� if'•.;ti�'����;� C',�,�' Municipal Offices
.q�� ����.� g, Mailing Address:
� � ��:;i;•� �i Street Address: .
. �E$�I� 2150 Keiley Parlcway P.O. Box 66
Orono, MN 55356 Crysta( Bay, MN 55323-0066
Owner: �qM�,S U �1 �Gr�� Address: So�S — indql� � /�/ .
Ciry Ordinance 199 requires that each existing on-site se�vage treatment system in Orono be inspected every rivo years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked belo�v.
SYSTEM CONFORMITY (1-3): � '
1 "CODE SYSTEM" An ISTS which meets all tha location,desigi and construction standards of the cuaent Orano hiunicipal Code.
2 "CO�IPLIANT SYSTEM" An ISTS which does not meet ali the location,design and mastruction standards of the currerrt prono I�funicipal
Coda but does meet tha three foot separation requiremrnt,and which is not failing or aa immineat thceat to public fiea2th ar saf�:ry.
�3 "NON-COi�IPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a daignated 100-year flood plaia,aay ISTS which may
or may not meet all the location,daign,or construction standazds of the curreat Orono 1�tuaicipal Code and vchich is failing for any reazoq and
any ISTS with less than three feet of uasaturated soil or sand bztwern the distn'bution device and the limiting�oil characteristics,
TANK CONDITION(5-10): S •
Tank inspection indicates: .. -
� Pumpout not nraded at this time.
f) Tank must be pumped out tivs year (city coda tequires tanks to be pumptd out every 3 years. Tank was last pumped ��'�'�0 )
7 Solida ac�vmulation in Lznks u at a critical a criticallavaL Tanlcc should be pumped out as soon u possible.
8 System is discharging ta the surface. Tanks miut ba pumped out within 48 haurs to eliminate surface discharge.
I Irupcction cisers missing-tanks could not be itupected Inspection tisars(4"dia pipe)must ba installed in each tank at aest pumpout If tanks
hava not been pumpad out within the lazt three years,they should be pumped out now.
1� Insptctiun pipt is locatzd direcdy over tacilc ba@le(doas not give accurate mauurement of solids accumutation). If Gznks havt not bern pumped
out within the lut three years,they should be pumped out now.
DRAINFIELD CONDTTION(11-14): ��
� Ikainfield'u dry,no surfacing evident
12 Some e�ndanca oFsurfacing,not crilica!yet . � ' '
13 DrainFeld'u uturatrd and visibly discharging unktatad e@lurnt to the surfaca Contact the City Inspector unmediaLaly.Repairs must be
complatad«tthin 90 days.
1� Drs'uif'iald ea�ant and condition unknown.
COIvli�NTS: 5 S-�c�.. ",s �e�—Con. �;q,.,� d�c 1-o I�c, al 3 -�oo-�- Sr �,�c}��� 6�'�,.ce� ���
o-�- -rr�r.��eS � +oP D� e�so�l .�.4ficr +�,ble
7-a6-a► G��
Date af Inspcction Septic Syscem Inspectoc .` '
Notr,: In the event that this iaspaction report is used W satisfy the requiremenis for a mortgage oc otfier tra�sfer of property,be advised that thic tepoR does aot guarantae
or cectify that aa esisting system will continue to function properly,bat is merely an opinion of the adequary of the system uader cvuent conditioas bazed on the availabla
informatioa
/'--_�_O`��\.
i� \
;� �\•
���0 O\
, �,�
i, \�Ii
; , ,�,a r r ,. ;, CITY of ORONO
, a i . �� �+ ��
�C„ !; Municipal Offices
` ,"`. 1 � 'ti�
���� �'- �. ����' � ` Street Address: Mailin Address:
�\,�9 ¢�,� g
.,.,$'ESHQ / 2750 Kelley Parkway P.O. Box 66
�_-� Orono, MN 55356 Crystal Bay, MN 55323-0066
March 24, 2000
James & Marga.ret Ogland
�2� Femdale Road North
Wayzata, Mn 55391
Dear Mr. & Mrs. Ogland:
An inspection of your septic system was conducted on Mazch 24, 2000. A summary of the inspection
is below.
Septic Tank CondiNon
1. Pumpout needed within one year(last pumpout 5/1/96)
The septic system is non-compliant due to a lack of a three foot separation distance between the bottom
of the drainfield to the seasonally high watertable. The three foot requirement is a State Code,not a City
Code. A soil boring was conducted to determine the depth of the seasonally wateRable. The septic
system must be replaced by December 31,2008.
Enclosed is a list of state licensed septic contractors �-ho work in Orono on a regular basis. Also
enclosed is a fact sheet explaining how a septic sy�stem functions properly. Finally, an as-built drawing
is enclosed that shows the approximate location of the septic system.
If you have any questions regarding this report; please contact me at the City Offices at 249-4600.
Re ectfu
t
� ,�C�,�,'�
Chris Pence
On-Site Systems Manager
Enclosures
In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be
advised that this report does no guarantee or certify the esisting s}-stem will continue to function properly,but is
merely an opinion of the adequacy of the system under current conditions based on the available information.
This report must be kept on the premises with the system location and pumping records.
Telephone(612)249-4600 • Fax(612)249-4616
/ / O�
/� /�
'�� � �
�;
� '��`�� CITY of ORONO
� t� �I%
� ���
��b �� !4/i Municipal Offices
'���,� + ,`�;�G�'� SVeet Address: Mailing Address:
9 ' � ��4�
' \ k,EggO 2750 Kelley Parkway P.O. Box 66
- Orono, MN 55356 Crystal Bay, MN 55323-0066
Ouner: Address: 525 Ferndala Rd. N.
Permit #'s: none Dates: Contractors: unknown
(This is � an existing system [ ] new construction) .
SYSTEM COMPLIANCE (1-3) : 3
1 Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
� Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom
of the drainfield and the saturated soil level.
(The saturatad soil lavel is [ ] or is not [ ] identified under this septic system. If the
saturated soil lavel is not i entifiad, this classification is subject to revision.)
TANK CONDITION (5-9) : 10
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out witl�in three years, they should be pumped out now.
10 One or more tanks are cesspools, which means the septic system is non-compliant.
(Tha tanks are [ ] or are not ] water tiyht or the condition is ( ] unknown. If the tanks
ara not confirmed to be watarti ht, this classification is subject to revision.)
DRAINFIELD CONDITION (11-14) : 13
11 Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface.
Contact the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : failinQ
COMMENTS: The septic system is non-compliant and is discharging effluent to the surface, which
is an imminent threat to public health or safety. The system must be repaired or replaced by
10/15/98.
�9� � �
Date of Inspection Sep c System Inspect r
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 • FAX 473-0510
CITY OF ORONO � O�
Municipal Offices O � O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT
� � INSPECTION REPORT
ti
�L9kESH��'�G
Owner: J��1ll� � Address: ��� �Y)'1'AQI� �e /V�
r
Permit #'s: �1'Zf' Dates: Contractors: l/1"?Kt'li���✓Y�
City ordi.nance number 1Q0 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is �1, an existing system ( ] new construction)
SYSTEM CONFORMITY (1-3): _�
1 "CODE SYSTEM"-A system uhich meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface uaters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but uas installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current seuage input uithout discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and an s stem with less than 3 feet of unsaturated soil or sand
��tween tDe �' tts ribution device and the limiting soi c �W�_ . � --� S��
(The limiting soil characteristic� has or [ ] has not been identifie �a�ltfiis�m . ��the limiting soil
characteristic has not been identi ied, this classification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
5 Purtipout not needed at this time.
6 Solids accumulation in tanks indicates they should be d out this year to help prevent future problems.
7 Solids acc�unulation in tanks is at a critical level. Tan s should be pixnped out as soon as possible.
$.� System is discharging to the surface. Tanks must be pumped out uithin 48 hours to eliminate surface dischar�e.
� Inspection risers missing-tanks could not be ins cted. Inspection risers (4" dia. pipe) must be installed in each
tank at next ut� If tanks hav n pumped out within the last three yearsd they should be pumped
out now. �� 1(��v}��
10 Inspection pipe is lbcated «Trec ly o er tan�baf le (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINfIELD CONDITION (11-14):
Dr field insp�ction indicates:
�11�Drainfield is dry, no surfacing evident.
Y1 Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
irtmediately. Repairs must be completed uithin 90 days.
14 Drainfield extent and condition unknown.
LIMITING S[TE FACTORS (slope,setbacks,etc.): p
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): �G�,y---�
� �I
COMMENT : '� � . � ' � �C� Sf�� � �' ^rJ'�'"QQl
r � ►�'�r
S 5 h '^.` � ' � � ''�.- ` � r
,� ✓..
Date of Inspection Septic yste nspector
Note: [n the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system uill continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the pre�nises with the system loc=tien and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
CITY OF ORONO � O�
Municipal Offices O � O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON-SITE SEWAGE TREATMENT
� � INSPECTION REPORT
ti
���kESH��'�G
Owner: 1.��'�1/ ����i'K�l'� Address: ��� /-�y}'1�(rl" /�[�� 1��
Permit #'s: �'Y�'1�'�_ Dates: "� Contractors: "'�
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is ,(,T1-an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3): �
1 "CODE SYS7EM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input uithout discharging
any pollutants into ground or surface Waters.
3 "NON-CONfORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic [ ] has or E�1 has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
� System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surtace discharge.
Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. If tanks have not been pumped out within the last three�ears, they should be pumped
out now. "
10 Inspectio pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out uithin the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
Dr,6Sy�field inspection indicates:
(11� Drainfield is dry, no surfacing evident.
�2 Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City ]nspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING S1TE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): ��L�
COMMENTS: � r �_ S. jc fi�n,�s/,�•�✓r� �ns��� 9_�� �/�S �L�r� nvrr av r/'��'..J,
`�
, _.
Date of Inspection Se ic System nspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certtfy that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the premises with the system toc�tien and pumping records.
WHITE COPY/lnspectors File YELLOW COPY/Homeowner