Loading...
HomeMy WebLinkAboutseptic info SEPTIC SYSTEM INVENTOR Y Address: 3090 Farview Ln. PID: 04-117-23 34 0011 Building Type residence BRs Install'd for: 3 In Musa: Yes Permit#: 7138 Date of Permit: 9/6/83 Installer: Widmer Bros. System Type: lined trenches Performance: no Tank Filter: SYSTEM CONDITION Conformity: 3 Tank Condition: 9 DF condition: 8 Failure Pot: medium SEPTIC TANKS �.� Material: precast concrete Capacity: 1000, 1000 ` � Setback to Bldg: 50 CesspooL• � � � DRAINFIELD � � Length of Lines: 365 # Lines: 5 Trench Width: 3 Treatment Area: 1100 Type of Filter: rock,clean sand Soil Boring: yes Tile Size: 4 Under Tile: 12 Perc Rate: 80 Setback DF-Bldg: 100 DF Ht above Wt: 0.7 Soil Type: sandy clay Limitations: water table WELL DATfI Setbacks - Well-Tanks: 75 Well-DF: 100 Report in File yes Pump Type: subm. Depth: 155 Diameter: 4 Method: drilled INSPECTION RECORD PUMPO UT RECORD DATE DESCRIPTION COMPLIANCE DATE GALLONS 9/7/83 installation 1 10/3/89 2400 9/4/84 no surfacing 1 7/27/92 1500 4/22/86 no surfacing 1 1/13/93 1500 8/25/88 no surfacing 1 9/17/93 2000 7/30/90 no surfacing 1 4/28/97 1800 7/19/91 no surfacing 1 7/17/02 2500 11/1/94 no surfacing 1 "] - ,�?f—U� „��� 8/27/96 non-conforming-repair by 12/31/2006 3 5/24/99 non-compliant-repair by 12/31/2006 3 7/12/O1 non-compliant,replace by 12/31/2007 3 7/24/03 non-compliant,replace by 12/31/2007 non-compliant C� .,OS <` �( ` �, �.�,�'�=-j �- � �� c -� �� � -� � � � ���U� l�e �� � i _ _ __ _ — ,_ _ _, � i — g _ � W�L� TANK 1 �N (o`l' 5�' ou� C�� 57'�" - TANK Z IN (v�� Sc?' �'—'— ---•— - _ our �,3t � �I ' � D-eox � �/I ' -78��" 1 _ ._ ' " � \ � � h �-aoX Z y`� � g� B , \ D_gox 3 5£3��" �i'7 � �� '� . .\ � _ /i�h '� �. � :'' •� i�. h� \ �� .� � \ .3: � \ \ \. � _ �2p � � � �, �•� �h3i � � � � � ' � � � ` • � � � � � - � �� � � � •� � � ,f � � � � '� � �v� '� � � � �\ � '� - � � � � � � � �. \. �L � � , � � _ _.___.; � � " ' � O `'' '� `��'��� CITY of 4R4Na ,i a � � �, �,,!� � ,� ��, -i Municipal Offices Street Address: Mailing Address; ��`9.k � p�'�� 2750 Kelley Parkway P.O. Box 66 EsK _,_ _- Orono, MN 55356 Crystal Bay, MN 55323-0066 To: The Current Owner of Address � � �f C� I�/-�- J� i�f�t,c.a City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewa�e treatment systein at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes l�To � If yes, please contact the Onsite Systems Mana�er at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identifi d as Non-Compliant Yes No If yes, system must be brought i ompliance by: December 31,20Q7 December 31, 2010 Other Septic Tank(s) Pump out Needed Yes �No The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every three years. City records indicate the tank(s) were last pumped out on --1�� � -� � . The tank(s) should be cleaned through the manhole and not through the inspection pipes, this allo�vs for proper cleaning. Comments: ,r,�� ��� ,� �, `�d„��+���.'�, �?" � � ��Ia ��� C? .5 Insrector. 4, Date of Inspection Telephone(9�2)249-4600 � Fas (9�2) 249-4616 µ��s.ci.orono.mn.us ;% o.�,.\, ,� � , ��o , _ o �, ' CITY of ORONO ii �� r, f t i; ,,�< �,,, J, ��\� �:� r ' ,- ��: �' ',�� � !�v�� Municipal Offices �,�� ' , ` ��� t'-�. G"�'�, ,; � � Street Address: Mailing Address: ,�9 �,�' ;g,�:��, �',�'EgKO.;:%' 2750 Kelley Parkway P.O. Boz 66 �`__-="� Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: -S �1�� �"—�;�W;�� L`'��.. City Ordinance 199 requires that each existing on-site sewa�e h•eattnent system in Orono be inspected every two years. The on-site sewa�e treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): �.� 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all che location,design and construction standards of the current Orono Municipal Code bu[does meet the three foo[separation requirement or t�vo foot requirement for systems installed 1996 or earlier,and wltich is not failing or an imminent threat to public health or safety. �"NON-COMPLIANT SYSTEM" A prohibi[ed ISTS;an ISTS located within a designated ]00-year flood plain,any[STS which may or may not meet all the(ocation,design,or consUuction standards of the current Orono Municipal Code and which is failing for any reason;and any[STS widi less than diree feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): S Tank inspection indicates: � Pumpout not needed at this time. Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped �-1'7 —C+�- ). Make sure septic tanks are pumped throu�h manhole and not throueh white inspection piaes. This allows for the proper cleaning. Keep water softner and iron filter dischar�e out of septic svstem. 7 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION 8-10 : 1� 8 Drainfield is dry,no surfacing evident. Some evidence of surfacing, not critical yet. 10 Drainfield is saturated and visibly discharging untceated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. COMMENTS: ��c�::..�--z1� �S r�o,.- Cc`���'1:5�-- �,��� :�.v�T- �j` �'��ii��cc�! �-j i�--'����1--�e� - � Z���^5 Ul'��ti ��-t� Date of Inspection Matt Bolterman- Septic System Inspector Note: [n the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. Telephone(952) 249-4600 • Fax(952) 249-4616 www.ci.orono.mn.us � o� :. �_, o ��� � CITY of ORONO � �;��_.� � ��1�������� � `�,� ,������ ti M�;� o��� l�•-"���Og�iG Street Addres�: Mailing Address: 2750 Kelley Parlcway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: RObe.c�'r Sc,�n-�:� '� Address: 3o�p F�rJ;e•., � n City Ordinance 199 requires that each eYisting on-site sewage treatment system in Orono be inspected every t�vo years. The on-site sewage treatment system at the above address has been inspected and appears to fail into the categories checked below. SYSTEM CONFORI�IITY (1-3): 3 1 ��CODE SYS1'EIvf�� Att ISTS which mzets all the localioq desig�and consttuction standards ofthe current Orono blunicipa!Code. 2 '�COMPLIANT SYSTEM�� r1n ISTS which does not meet all the locatioq design and rncutniction standards ofthe current Orono Municipa! Coda but does meet the three foot sepazalion requuzmerrt,and which is not failing or an imminznt threat to public health or safety. � ��NON-COMPLIANT SYSTEM�� A prohibited ISTS;an ISTS locat�d within a desgnated 100-year IIood plain,any ISTS which may or may not meet all the localion,design,or construction standards of the currnrt Qrono\itmicipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution dz�ir and thz limiting soil chazacteristics. TANK CONDITION(5-10): � Tank inspection indicates: J Pumpout not nezded at this time. OTank must be pumped out this year (city coda requirzs tanks to be pumped out e�•ery 3 years Tank was last pumped i"a�S—C17 �, 7 Sulids accumulation in tanks is at a critical a aitical le�•el. Tanks should be pumped out is soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to zlim�?_r�y�'ace discharge. y Inspection risers missing-tanks could not be inspected. Inspzction risers(4"di�pipe)must bz irLstalied in each tank at next pumpout Iftanks have nut bzen pumptd out within the last three years,they should be pumped out now. 1� Inspectiun pipa is located directly ovzr tank ba81e(does not give accuratz me�suremrnt ofsolids arcumulation). Iftanks have not bern pumped out within the last three years,they s}iould be pumped out now. DRAINFIELD CONDITION 11-14 : �_ 11 Drainfiald is dry,no surfacing evident 12 Soma evidenca of surfacing,not crilical yet 13 I?rainfiald is saturated and visibly dischazging untreated e@luent to the surface. Contact tha Cin•Inspector immediately.Repairs must be completed withict 90 days. 1-� Drainfieid axtent and condilion unknown. COI�Ii�NTS: S�(S-t-e�,, �S �o�- �o�Pl;�,� dvc t-o I�,cK d F 3 �oo�t-- Seper�-j- o� ����e�� S�� �.� 5ot�o..._ 0�- �rre�c��S. Re \a S 1�-3�_ a.067 S�ore15� ��4, �J �Q 'C'Gc�`L� � 7 -1�- o\ �� . Date of Inspection �• Scptic System Inspector Vote: In the evtnt that this irupection teport is used to satisfy the requuemecrts for a mortgage or other 7�sfrr of property,be advised that this report does not guazantze or certify that an tsisting systam will continue to function properly,but is merely an opinion of the of thz information. ��7' sys�m undzr currertt condilioru based on the available � °� �o _� o � � ��:��� _ �� CITY of URONO i i �.�j �'�� r�� ; ,��� , 1�, ����, � �, � Municipal Offices \ \� Y h3Y 1 � �`� ���� � ` �`�' �� Street Address: Mailing Address: � ; � �� ��'9$�K� 2750 Kelley Parkway P.O. Box 66 ��- _— Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: '� Address: 3090 Farview Ln. Permit #'s: 7138 Dates: 9/6/83 Contractors: Widmer Bros. (This is [� an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. � Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is [x] or is not [ ] identified under this septic system. If the saturated soil level is not identified, this classification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. � Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [ ] or are not [ ] water tight or the condition is [�] unknown. If the tanks are not confirmed to be watertight, this classi£'ication is subject to rev4 sion.) �D INFIELD CONDITION (11-14) : 11 /1]r Drainfield is dry, no surfacing evident. �-� Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medium CONIDIENTS: The septic system is non-compliant, but does not appear to pose an imminent threat to public health or safety (surface discharge or backup into the dwelling) . The system must be repaired or replaced by 12/31/2006 or within ninety days of posing an imminent threat to public health or safety, whichever comes first. ��-�9' .�.-_ Date of Inspection ep c System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone(612)249-4600 • Fax(612)249-4616 %o�\ ;� � �\, � !o 0 , ,�f , ,� CITY of URONO ,.� ta .. ,�� � ; { � ti MunicipalOffices "� ��.,jy� � �': � , ` � � �� t � �F;_r G;, � ,t9 , g,� � Street Address: Mailing Address: `� �C'�gg0�� 2750 Kelley Parkway P.O. Boz 66 ��_=-% Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: �f! �-'�=f'����-�'� Address:3090 Farview Ln. Permit #' s:7138 Dates:9/6/83 Contractors:Widmer Bros. (This is [� an existing system [ ] new construction) SYSTEM COMPLIANCE (1-3) : 3 1 Code Svstem: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant Svstem: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. � Non-Compliant Svstem: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three.feet of verti a between the bottom of the rain ie a e saturated soil level. (The saturated soil level ��], has or [ ] has not been identified at this time. If the saturated soil level has not been identified, this classification is subject to revision.) �ANK CONDITION (5-9) : 5 �� Pumpout not needed at this time 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout the tanks ( ] were or [�, were not confirmed to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be watertight, this classification is subject to revision.) �ELD CONDITION (11-14) : 11 1 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTZAL FOR SYSTEM FAILURE: (system acTe and condition, soils, etc. ) : low COMMENTS: The non-compliant septic system must be repaired by 12/31/2006 or within 90 days of failure (surface discharge) , whichever comes first. �`O��/�� J ��-" � �-----• Date of Inspection Sep��ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510