Loading...
HomeMy WebLinkAboutseptic info SEPTIC SYSTEM INVENTOR Y Address: 2820 Farview Ln. PID: 04-117-23 34 0005 Building Typexesidence BRs Install'd for: 5 In Musa: Yes Permit#: 5772 Date of Permit: 10/16/79 Installer: Westonka Plbg. System Type: standard trench Performance: no Tank Filter: SYSTEM CONDITION Conformity: 3 Tank Condition: 9 DF condition: 8 Failure Pot: medium SEPTIC TANKS Material: precast concrete Capacity: 1000, 1000, 1000 Setback to Bldg: 14 Cesspool: no DRAINFIELD Length of Lines: 440 # Lines: 4 Trench Width: 3 Treatment Area: 1300 Type of Filter: rock Soil Boring: yes Tile Size: 4 Under Tile: 12 Perc Rate: 22 Setback DF-Bldg: 40 DF Ht above Wt: 0.3 Soil Type: sandy clay loam, clay loam Limitations: water table WELL DATA Setbacks - Well-Tanks: 100 Well-DF: 100 Report in File yes Pump Type: subm. Depth: 156 Diameter: 4 Method: drilled INSPECTION RECORD PUMPO UT RECORD DATE DESCRIPTION COMPLIANCE DATE GALLONS 10/29/79 installation 1 6/22/87 1500 8/30/84 no surfacing 1 5/1/90 2000 8/6/87 no surfacing 1 5/1/92 2000 4/3/89 no surfacing 1 5/10/94 2000 7/30/90 no surfacing 1 4/10/96 2000 7/18/91 no surfacing 1 5/6/98 2000 10/28/94 no surfacing 1 6/O1/Ol 2000 8/23/96 non-conforming-repair by 12/31/2006 3 6/1/99 non-compliant-repair by 12/31/2006 3 7/10/Ol non-compliant,replace by 12/31/2010 3 7/29/03 non-compliant,replace by 12/31/2010 non-compliant 9 p) �� r� 1 � I�� � �t 5��� � � � -_ �_ ���Q �- -���/;eU� 1�- I� �� -- C� , -�. ! �'� �� _` J / � � i� � �I � _ - - - . i � / `' _` __� � / � / / / /. / / � . `� / � / � / .i � � D ���} ��� ��'D --- T. � � � � ,�'� 1 �� — � , ��� �r� �� I� , � o� ��� �s 6 ��1 �l� `7�/� 5��� �I '� �)'� ��� ��'D �'� ? , - �31� ��� � I UU _ ._.__.__. � �� i � O '`, �,; , � �� ciTY o� o�o�va ',! � �� ,% Municipal Offices � Street Address: Mailing Address: ���9x '' p��G 2750 Kelley Parkway P.O. Box 66 ESK ,-_.__ _ Orono, MN 55356 Crystal Bay, MN 55323-0066 To: The Current Owner of Address o� ��v �A-�v� �� City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewa�e treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes No 1/' If yes, please contact the Onsite Systems Mana�er at 952-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identif as Non-Compliant Yes No If yes, system must be brought into compliance by: December 31, 2007 December 31, 2010 —� Other Septic Tan�) Pump out Needed Yes No The City recommends the septic tank(s) and/or lift tank be serviced and pumped out every three years. City records indicate the tank(s) were last pumped out on (� -��.� j . The tank(s) should be cleaned through the manhole and not through the inspection pipes, this allows for proper cleaning. Comments: �' � ,. Inspector�� � :�� .� � :��` Date of Inspection � '�� J . � 4 Telephone (9�2) 249-4600 � Fax (9�2) 249-4616 �r ww.ci.orono.mn.us /� ii�� O�\� �O O�1 ��� ::; f �;,:. ;! C ITY of ORONO ,� ,a, , � . ,�,, ,�r�, �°�,� i�� �� �!� ;j Municipal Offices '�' ,�': ;; F�,�; G;. Street Address: Mailing Address: `':,�R' ; ;,;¢,�,:,♦' '�,kESHO�,' 2750 Kelley Parkway P.O. Box 66 ��---'' Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: �� ��� �`'���'f`�' �ej��- City Ordinance 199 requires that each existing on-site sewage h•earinent system in Orono be inspected every two years. The on-site sewa�e treatment system at the above address has been inspected and appears to fall into the categories checked Uelow. SYSTEM CONFORMITY (1-3): � 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requiremen[or two foo[requirement for systems instailed 1996 or earlier,and which is not fail ing or an imminent threat to public health or safety. � "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated ]00-year flood pfain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any[STS with(ess than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): 5 Tank inspection indicates: � Pumpout not needed at this time. 6 Septic tanks must be pumped out this yeac- (city code requires tanks to be pumped out once every 3 years. Tank was last pumped_ �a-i-c�� ). Make sure septic tanks are numped throuEh manhole and not throu�h white insnection pipes. This allows for the proper cleanin�. Keep water softner and iron filter discharge out of septic svstem. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia. pipe) must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. RAINFIELD CONDITION 8-10 : � 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing, not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. COMMENTS: p�.��:.��-.e1� �S r�cn- C��.�`�1,�r:�- �'•�r��� i��.vSfi- �� ;� 1�'��c � �� �"l.-�\-- 'ZC 10 . --�_zi-���� �;��� ���.. Date of Inspection Matt Bolterman - Septic System Inspector Note: [n the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised tliat this report does not guarantee or ceRify that an existing system will continue to function proper(y,but is merely an opinion ofthe adequacy of the system undercurrentconditions bazed on the available informatio�. Telephone(952)249-4600 • Fax(952)249-461b www.ci.orono.mn.us � o� o�;:,, o �`������a�=� CITY of ORONO ; a ' ����� �. � ���� s r �� �►��,�=���;��� ti M�;�;� o��� l ���, � ��-.;��;�`�g�G~ Street Address: MaiUnQ Addreu: E'SI't� 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: ��M �o w��� Address: a�Sao FG�� :e� �--n City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 3 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards ofthe current Orono biunicipal Code. 2 COMPLIANT SYS'I'EM" An ISTS which does not meet a11 the location,desigi and construction standards ofthe current Orono'�funicipal Code but does meet the three foot sepazation requirement,and which is not failing or an imminerrt threat to public health or safety. 3O ��NON-COMPLIANT SYSTEM�� A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the cuireirt Orono Municipal Code and which is failing for any reason;and any ISTS with less than three fzet of unsaturated soil or sand between the distribution device and the 1'uniting soil characteristics. TANK CONDITION(5-10): � Tank inspection indicates: � Pumpout not needed at this time. � Tank must be pumped out this year (city code requues tanks to be pumped out every 3 years. Tank was last pumped S��- -` D �, 7 Solids accumulation in tanks is at a critical a critical IeveL Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface dischazge. 9 Inspection risecs missing-tanks could not be inspected. Inspection risecs(4"dia.pipe)must be installed in each tank at ne.�ct pumpout Iftanks have not been pumped out within the last thrze years,they should be pumped out now. 10 Inspection pipa is located directiy over tarilc ba61e(does not give accurata measurement of solids accumulalion). If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION(11-14): l\ 1 1 Drainfield is dry,no surfacing evident 12 Some evidence of surfacing,not criticai yet 13 Drainfield is saturated and visibly dischazging untreated e$luent to the surface. Contact the City Inspector immediately.Repai�must be complzted within 90 days. 1-� Drainfield extent and condition unknown. CO1�Il�IENTS: SyS�e� �5 �`oc�- eo�,pl;s�� Jv� ro ��c,k o� 3 �oo� Sepfrqfi- o,� h�T�-«.. ��e� �-�5�� �� bb�to.� o� �rcc^e,�.eS_ c \qc. � Id-31 -�o(o. p��.� -����c.s - 7 —�o —o � �11 c�C ��e2 - �M Date of Inspeclion Septic System Inspector ' Note: In the event that this inspection repoR is used to satisfy the requirements for a mortgage or other traasfer of property,be advised that this repoR does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under currerrt conditions based on the available informaliaa ;—� �' � ��V � , � i��� � _ O�� �� , - �� CITY of ORONO ��+� ��� �l,��.�; �+ ;' � +�,� �'t �// Municipal Offices �� � , � t, "- G~'/ Street Address: Mailing Address: ���'91t�Kp'¢'� 2750 Kelley Parkway P.O. Box 66 ��� Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: ��(��j ���� P.ddress: 2820 Farview Ln. Permit #'s: 5772 Dates: 10/16/79 Contractors: Westonka Plbg. (This is [� an existing system [ ] new construction) . SYSTEM COMPLIANCE (1-3) : 3 1 Code System: �ieets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes aad is func�icning prcperly. � Non-Compliant System: System may or may not meet current City standards fc� d�s�g:, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the arainfield and the saturated soil level. (The saturated soil level is [�] or is not [ ] identified under this septic system. If the saturated soil level is not identified, this classification is subject to revision.) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharginq to the surface. Tanks must be pumped out within 4S hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out �� within three years, they should be pumped out and risers installed now. � 9') Inspection pipe is located' over tank baffle-can not measure solids accumulation. If tanks v have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [ ] or are not [ 7 water tight or the condition is [�] unknown. If the tanks are not confirmed to be watertight, this classification is subject to revision.) �INFIELD CONDITION (11-14) : 11 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : medium COMMENTS: The septic system is non-compliant, but does not appear to pose an imminent threat to public health or safety (surface discharge or backup into the dwelling) . The system must be repaired or replaced by 12/31/2006 or within ninety days of posing an imminent threat to public health or safety, whichever comes first. �--f—�9 .s� � Date of Inspection e ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone(612)249-4600 • Fax(612)249-4616 � - �� /j O \ � � ��� /,i�O O ..,�; ' , ��.f �,. C ITY of ORONO r� �: .; , � _ ►�+' ' f Eti � Municipal Offices `� � �` � ' '; '�, // �'�\� ' '`'� � ��� �� ,� � �� � � ;�G�� Street Address: Mailing Address: `�;9$Eg�� 2750 Kelley Parkway P.O. Box 66 � —= Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: �/ '�/1� ,��_ / /��%.�•� ��__ Address:2820 Farview Ln. Permit #'s:5772 Dates :l0/16/79 Contractors:Westonka Plbg. (This is f;{] an existing system [ ] new construction) . ti SYSTEM COMPLIANCE (1-3) : 3 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant Svstem: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance �, with previous codes and is functioning properly. �3J' Non-Compliant Svstem: System may or may not meet current City standards for design, J construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. � .._.. ._ _. _--__ _ ._ _,. �.._ --�_._------� (The saturated soil level � has or [ ] has not been identified at this time. If the saturated soil level has not been identified, this classification is subject to revision. ) TANK CONDITION (5-9) : 9 5 Pumpout not needed at this time 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. � Inspection pipe is located over tank baffle-can not measure solids accumulation. If `-' tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout the tanks [ ] were or �] were not confirmed to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be watertight, this classification is subject to revision. ) DF�AINFIELD CONDITION 11-14 : 11 1 Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (system aqe and condition, soils, etc. ) : medium COMMENTS: The non-compliant septic system must be repaired by 12/31/2006 or within 90 days of failure (surface discharge) , whichever comes first. , "v� � �°� > �. J Date of nspection Sep�' �System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Tetephone (612) 473-7357 • FAX 473-0510 CITY OF ORONO � O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 a � ON—SITE SEWAGE TREATMENT r�,� � INSPECTION REPORT '�� G~ `�k�sxo�'*� Owner: ��QY7��� (l'l�i�l� Address: ��v`� TC�1'�1/1i`��lnJ [—r�� Permit #'s: �/„C Dates: �Q'"�U�� Contractors: f���C�^.�C�.'7 �dj..'?� City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is �an existing system [ ] neW construction) SYSTEM CONFORMITY (1-3): � "CODE SYSTEM��-A system uhich meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the curr•ent City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located uithin a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system uith less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic�has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identi ied, this classification may be subject to revision.) TANK COkD1TlON (5-10): 7ank inspection indicates: 5 Purtipout not needed at this time. 6 Solids acc�nulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. 7anks should be pumped out as soon as possible. 8 System is discharging to the surface. 7anks must be pumped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out uithin the last three years, they should be p�xnped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been punped out within the last three years, they should be pumped out nou. DRAINFIELD CONDITION C11-14): Dpa�nfield inspection indicates: /1q Drainfield is dry, no surfacing evident. `12 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector irtmediately. Repairs must be completed uithin 90 days. 14 Drainfield extent and condition unknown. LIMITING S1TE FACTORS Cslope,setbacks,etc.): POTENTIAL FOR SYSTEM FA[LURE (depends on soils,water table,etc.): � ���[ i/_1Y1� COMMENTS: � Date of Inspection ep ic System nspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the prE�nises with the system loc=tien and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner On the North Shore of Lakc Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 1335 S. Brown Rd. � � ° Crystal Bay, MN 55323 473-7357 OWNER /� u��s ���� ADDRESS �v� ��'��'�� �*" /� PERMIT NO.'S. �77a DATES ��/� CONTRACTORS � City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been i�spected and appears to fall into the category checked below. (This is �an existing system ❑ new construction) {a 1 Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating ��' properly. � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance wiih previous codes. System appears to be functioning properly; no major upgrading of the system is required at this time. � 3 Does �ot meet current City standards in many respects relating to design,construction, or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgradi�g of system is required at this time. � 4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard, or is otherwise creating a public�uisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank'nspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not �Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulatio� in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. �Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) �4dequate ❑ High water table C� Low ❑ Fair O Lot size �Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑ System is causing visible surface discharge. COMMENTS: 7-I g-`�� Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/ Inspector's File GOLD COPY/Homeowner