City Ordinance requires that onsite sewage treatment systems in Orono be
inspected on a periodic basis. The onsite sewaDe treatment system at the above
address has been inspected and the followin�is known about the system. A
sketch of tlle known components of the system is available for most properties at
the Orono City HaIL
Imminent Public Health Threat
Yes �No
If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10
days of receipt of this notice. The septic system must be brou�ht into compliance
within 90 days. Failure to do so will result in referral to the City Attorney for
legal action.
System Identifi �as Non-Compliant
Yes
l�o '
If yes, system must be brought into compliance by:
December 31, 2007
December 31, 2010 �
Other
Septic 'Tank(s �np aut Needed
Yes
No
The City recommends the septic tank(s} and/or lift tank be serviced and pumped
out every three years. City records indicate the tank(s) were last pumped out on
�j- !3- G�2 . The tar�(s) should be cleaned through the manhole and
not throu�h the inspection pipes, tlus allows for proper cleaning.
Comments:
.y� w ,p��n �� `
Inspe "�r��y����� '��^'��� Date of Inspection � � U l� •
Telephone(9�3) 249-4600 • Fa� (9�21 2-i9-461fi
�
o.�,.
0 0
C ITY of ORONO
,� r y��• a.
r.�
,I
' � " �, MunicipalOffices
� �s ,\ ti
�,t9 `,g,�G Street Address: qsa-a4q'y6� � Mailing Address:
Ji'�Hp 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: Address: ���� �`�'� ' ^ �r���
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3): �
] "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono
Municipal Code but does mee[the three foot separation requirement or two foot requirement for systems installed 1996 or eazlier,and
which is not failing or an imminent threat to public health or safety.
( 3 J"NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may
��or may not meet all the location,design,or consWction stan�rds of the current Orono Municipal Code and which is failing for any
reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the luniting soil chazacteristics.
TANK CONDITION(5-7): `�
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
Tank was last pumped �'����=� ).
Make sure septic tanks are pumped through manhole and not throu�h white inspection pipes. This allows for the proper
cleaning. Keep water softner and iron filter dischar�e out of septic system to prolong life of drainfield. Ask pumper to test
alarm float to verifv alarm is still workin�in your house. The alarm warns owner that septage is about to backup into basement.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4" dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
D INFIELD CONDITION 8-10 : �
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMMENTS: �C�.^�-:t\�C `�5 t�o�- C o��►\:�,..�r ��� �,,,�� �C 6(��a(�(/
� --� �t—�1-- 10�u ,
� � ���- �a�c ���_
Date of Inspection Matt Bolterman - Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does
not guarantce or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current
conditions based on the available information.
� o�
o:,:{�. o
=1���=� CITY of OIE�ONO
� '���'l.�j �
r�;, �j���,,•�`;`�� ,�F+ Municipal Offices
'C� 'K'^�'��������r G
�!;,:•��.�<.,�.k ,� Street Address: Mailing Address:
�`q$'�Eg'gOg' 2750 Kelley Parkway P.O. Bax 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
9sa-�y9-46o0
To Current Owner: Address: aa�.s �C v�•n � �1 n 2
Ciry Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewa�e treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-31: 3
� "CODE SYSTEM'� An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
),���
2 "COMPLIANT SYSTEM" M ISTS which does not meet all the location,design and conswction standards of the current Orono Municipal
Code but does meet the three foot separation requirement or two foot requirement for systems ins t a l le d 1 9 9 6 or ear lier,an d w hic h is no t fai]ing or
an imminent threat to public health or safety.
� "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may
or may not meet all the location,design,or conswction standazds of the current Orono Municipa]Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5:]�: �
Tank inspection indicates:
5 Pumpout not needed at this time.
� Septic tanks must be pumped out this year (ciry code requires tanks to be pumped out once every 3 years.
Tank was last pumped `�' �7 -`��- �•
Nlake sure septic tanl:s are aumped through manhole and not through white inspection pipes,_
This allows for the proper cleaninQ.
7 Inspection risers missinb tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank.
DRAINFIELD CONDITION - 0`: �
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfie(d is saturated and visibly dischazginD untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
K_� �� s�L'c�- t c�.� ��,c.��-�` ��� Y`��% M" �C �P ��s c Q�
COMIvIENTS: 5 y S �
� � ��-�� - ��io p,,, �,.� �� �\� �
� - \ � -O� ��. ����vn--t:-�
Date of Inspection Matt Bolterman - Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this rcpoR doa not guarancee
orccRify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available
infortnation.
o�
� ��� �,
0 0�,
� CITY of ORONO
.f� -� ,�,
,� �; � -
r�',, �` ,�l4 ; Municipal Offices
� �`�� G �� Street Address: Mailin Address:
� S
� ��9�f�ggOg'��/ 2750 Kelley Parkway P.O. Box 66
' ' Orono, MN 55356 Crystal Bay, MN 55323-0066
Julv 11, 2000
William&Helen Hartfiel
222� Devin Lane
Lon� Lake, Mn 5�356
Dear Mr. & Mrs. Hartfiel
An inspection of your septic system was conducted on July 10, 2000. A summary of the inspection is
belo���.
Septic Tank Condition
1. Pumpout not needed at this time.
The septic system is non-compliant due to a lack of a three foot separation distance between the bottom
of the drainfield to the seasonally high�vatertable. The three foot requirement is a State Code, not a City
Code. A soil boring was conducted to determine the depth of the seasonally watertable. The septic
sy�stem must be replaced by December 31,2010.
Enclosed is a list of state licensed septic contractors �vho �vork in Orono on a regular basis. Also
enclosed is a fact sheet explaining how a septic system functions properly. Finally, an as-built drawing
is enclosed that shows the appro�cimate location of the septic system.
If you have any questions regarding this report, please contact me at the City Offices at 249-4600.
ectf
, ���
�s Pence
On-Site Systems Manager
Enclosures
In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be
advised that this report does no guarantee or certify the etiisting system will continue to function properly,but is
merely an opi�ion of the adequacy of the system under current conditions based on the available informntion.
This report must be kept on the premises���ith the system lacation and pumping records.
Telephone(952)249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
/--i—��
/ � �'\
i�0 O��
'' CITY of ORONO
�� _ � ;;
��' � ; �ti� Municipal Off'ices
\� t �r� �t '�_.
� ���.� �'�.��: ��.`�.`��.��� Street Address: Mailing Address:
�� �$EggOg' 2750 Kelley Parkway P.O. Box 66
\��— Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: L��//��h"7 �✓7' -�j�� � Address: 2225 Devin Ln.
Permit #'s: 6528, 10115 Dates: 10/30/81, 4/17/98 Contractors: Ouverson Exc. , Sullivan
(This is [x an existing system [ ] new construction) .
SYSTEM COMPLIANCE (1-3) : 3
1 Code System: Meets or exceeds current City standards in all respects relating to design,
cor.struction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
mos� respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
,� Non-Compliant System: System may or may not meet current City standards for design,
v construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom of
the drainfield and the saturated soil level.
(The saturated soil level is [� or is not [ ] identified under this septic system. If the
saturated soil level is not identified, this classification is subject to revision.)
�NK CONDITION (5-9) : 5
� Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
10 One or more tanks are cesspools, which means the septic system is non-compliant.
(The tanks are [� or are not [ ] water tight or the condition is [ ] unknown. If the tanks
are not confirmed to be watertight, this classification is subject to revision.)
DRAINFIELD CONDITION (11-14) : 11
, 1 J Drainfield is dry, no surfacing evident.
`L� Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact
the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium
COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings
were performed to verify a 3 foot separation between the drainfield and the seasonal water table.
The separation is 0.8 feet and the system is non-compliant. Repair or replacement of the septic
system is required by 12/31/2008.
/i�3� � 9�' v
Date of Inspection tic Sys em Ins ector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone (612) 473-7357 • FAX 473-0510
CITY OF ORONO � O�
Municipal Offices O � O
Post Office Box 66
Crystal eay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT
r�,� � INSPECTION REPORT
ti
��9kESH04'�G
Owner: (/Vl��d n� 7 IU P I Address: �t�c�C� > �%/�� L-f)�
Permit #'s: Dates:���" Contractors: l�!/(°�1^� �(G.
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is fJY,an existing system [ ] neu construction)
SYSTEM CONFORMITY (1-3):
1 "CODE SYS7EM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface uaters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet aLl the location, design, and construction standards of the current City
Codes and uhich is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the Limiting soil characteristics.
(The limiting soil characteristic �has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identi ied, this classification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
S Purt�out not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accurtwlation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out uithin 48 hours to eliminate surface dischar�e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next purtipout. If tanks have not been pumped out within the last three years, they should be pumped
out now.
Q Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been purtiped out withi, 'n th�st three year th y should be pump d o t now.
. � nks �e 1�- 90?
DRAINFIELD CONDITION (11-14):
D�e�,qfield inspection indicates:
L'W' Drainfield is dry, no surfacing evident.
12 Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City [nspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING S1TE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM fAlLURE (depends on soils,water table,etc.): �
COMMENTS:
Date of nspection Sept c System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
informatton.
This report must be kept on the prE�nises with the system locetien and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
CITY OF ORONO � O�
Municipal Offices O � O
Post Office eox 66
Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT
� � INSPECTION REPORT
ti
��9kESH0��G
f���� �� �
Owner: /► J /C � �%TY��7-F it�J Address: ���� � % L+�
Permit #'s: Z��� Dates:�/�_S,(!-'c�� Contractors:_C/��10�✓=��''� �XC .
City ordi.nance number 100 requires that each on-site seWage treatment system in Orono be inspected on a regular basis.
7he on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is t�--an existing system [ ] neN construction)
SYSTEM CONFORMITY (1-3): •
7� "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system Which does not meet all the location, design, and construction standards of the
current City Codes, but uas instalted according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system uith less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic {�has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10): 'L,
Tank inspection indicates:
5 Pumpout not needed at this time.
b Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out uithin 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. If tanks have not been pumped out Within the last three years, they should be pumped
out now.
0 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
Dr,e�nfield inspection indicates:
(1Y Drainfield is dry, no surfacing evident.
`'12 Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
irtmediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): �/���.
COMMENTS: � Sr� c� 7rA�� 1-✓P1�P �c�����rG�� �/�`d`� �iz�s�,,./9 L� rr�+G�'�Gv�✓li�,�,
�
�' - � .✓
Date of Inspection ptic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system uill continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
7his report must be kept on the pre�nises with the system loc�tion and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
On tl�e North Shore o f
Lake Minnetonka
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT � POST OFFICE BOX 66
� _ � � 1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
OWNER ,�,/,���`1 9� �7f'/Pll /�✓T�-iP/ ADDRESS ��� L.l"i�J%'\ L�In�
PERMIT NO.'S. n�� DATES /���VgI CONTRACTORS � ✓�r` - A'�,
City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is � an existing system ❑ new construction)
�� Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
properly.
� 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes. System appears to be functioning properly;no major
upgrading of the system is required at this time.
� 3 Does not meet current City standards in many respects relating to design,construction, or location.Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
� 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and
dispose of the current input,and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is
creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( m Checked items may require your action)
Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Dces not
(� Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks
❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they
ed out this yeer to help prevent future problems. should be pumped out now.
❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates:
should be pumped out as soon as possible. �Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated
❑ Inspection risers missing—tanks could not be inspected. effluent to the surface. This condition may require replace-
Inspection risers (4" dia. pipe) must be installed in each tank ment or additions to drainfield. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days.
the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Future Expansion
❑ Soil table and system condition) �Adequate
❑ High water table �Low ❑ Fair
❑ Lot size ❑ Medium ❑ Poor
❑ Lake,wetland,or stream ❑ High . ❑ Inadequate
❑ Drainage ❑ System is causing visible
surface discharge,
COMMENTS:
//�`��� .�
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/Inspector's File GOLD COPY/Homeowner