HomeMy WebLinkAbout1997-08-08 septic info � o�
o : o
��������-�=� CITY of 4RON0
,������j�� �� �
'a '�;� `'� -�'
� r�',, �, �'. '��. � ti Municipal Offices
� `"����'�_°� G�
.�9�. �,�,y�4;.�¢.� Street Address: Mailing Address:
jfEggO 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner: � ! � Address: 250 Old C
rystal Bay Rd. S.
Permit #'s: 7710 Dates: 11/14/84 Contractors: Thompson Plbg.
(This is [X ] an existing system [ ] new construction) .
SYSTEM COMPLIANCE (1-3) : 1
1 Code System: Meets or exceeds current City standards in all respects relating to design,
construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
3 Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom
of the drainfield and the saturated soil level.
(The saturated soil level (X] has or [ ] has not baen identified at this time. If the
saturated soil leval has not been idantified, this classification is subjact to revision.)
TANK CONDITION (5-9) : 5
S Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
(During the last saptic tank Maintanance Pumpout the tanks [ ] were or [X] were not confirmed
to be watertight by the licensed pumping contractor. If tha tanks ware not confirmad to be
watertight, this classification is subject to revision.)
DRAINFIELD CONDITION (11-14) : 11
1 Drainfield is dry, no surfacing evident.
12 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface.
Contact the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : low
COMMENTS:
C� � � \ ���/X�(, '> >
Date of Inspection eptic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telep6one (612) 473-7357 .• FAX 473-0510
CITY OF ORONO � O�
Municipal Offices O � O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT
,� � INSPECTION REPORT
ti
��9kESH0��G
� � (�� _
Owner: �n]��� � � � Address: � /�7� �
Permit #'s: ��� Dates: ��� Contractors:
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked belou.
(This is (� an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic j� has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out uithin 48 hours to eliminate surface discharge.
9 Inspection risers missing-tanks could not be insPected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. If tanks have not been pumped out uithin the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
Dr nfield inspection indicates:
�1 Drainfie[d is dry, no surfacing evident.
1Z Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
imnediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): �y�
COMMENTS:
✓
N -
Date of Inspection S tic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the pre�nises with the system loc�tion and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
On the North Shore o f
Lake Nlinnetonka
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT � POST OFFICE BOX 66
1335 S. Brown Rd.
� � � Crystal Bay, MN 55323
473-7357
,� _—�r � ,�'' ��
OWNER �aC'f;/�1=>" I/>[:�'!;1'1>���" � ADDRESS �,��:� C���_l`�I�'�� �,'s�' J�1� �.
PERMIT NO.'S. ��r�? DATES �� (�� k�/. CONTRACTORS �'` y'3'� �
City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is � an existing system ❑ new construction)
� � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
properly.
� 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes.System appears to be functioning properly;no major
upgrading of the system is required at this time.
� 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
n 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and
�—'� dispose of the current input,and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is
creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( m Checked items may require your action)
Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Dces not
:�Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks
Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they
ed out this year to help prevent future problems. should be pumped out now.
❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates:
should be pumped out as soon as possible. � Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated
❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace-
Inspection risers (4" dia. pipe) must be installed in each tank ment or additions to drainfield. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days.
the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Future Expansion
❑ Soil table and system condition) ❑ Adequate
❑ High water table � Low �Fair
❑ Lot size ❑ Medium Poor
❑ lake,wetland,or stream ❑ High ❑ Inadequate
❑ Drainage ❑ System is causing visible
surface discharge.
COMMENTS:
/f 1�� �6 �`- � ..—
Date of Inspection tr eptic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to functio�properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY!Inspector's File GOLD COPY/Homeowner