Loading...
HomeMy WebLinkAbout2003-P06514 - mechanical CITY OF ORONO PERMIT 2750 Kelley Parkway- PO Box 66 Permit Number: Po6si4 Crystal Bay, Minnesota 55323 Permit Type: Mechanical Permits (952) 249-4600 Date Issued: ��s�2oo3 SITE ADDRESS: 2740 Deer Run Tr E I.ong Lake,MN 55356 PI D: 04-117-23-13-0010 DESCRIPTION: Proposed Use: Residential Permit Class: General Permit Type: Mechanical Permits Permit Sub-type(s): Multiple Mechanical Items DETAILS: Approved per resolution#: Separate pernuts required: NOTICES/REMARKS: FEE SUMMARY: Pernut Fee: $ 474.56 Valuation: $ 37,965.00 State Surcharge Fee: $ 18.98 TOTAL FEE: $ 493.54 APPLICANT: Angell Aire Inc. OWNER: Mary Stuart Fox 12243 Nicollet Ave S. 2740 Deer Run Tr E Burnsville,MN 55337 Long Lake,MN 55356 THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF MINNESOTA BUILDING CODE REQUIREMENTS. -7 t � _ �,Q.�'l�� Ce'-,� �� APPLICANT PERMITEE SIGNATURE ISS ED BY SIGNATURE Cooies: 1-File(SiQnitures Reauired), 1-Apolicant, 1-Monthlv Renorts, 1-Assessine, 1-Finance Page 1 CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Page 1 of 3 . CITY OF ORONO APPLICATION FOR MECAANICAL PERMIT Box 66 (2750 Kelley Parkway) Crystal Bay, MN 55323 GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within two working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs- Complete calculations,details and specifications are required for each heating, ventilation,humidification-dehumidification, and air conditioning installation including heat loss/heat gain calculation,design temperatures,equipment ratings and identification as to type,manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call (952) 249-4600. 24-hour notice required. 7. House Heating Test Record must be submitted before final. Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call (952) 249-4600. Please check one New Addition Repair Replace Residential Commercial JOB SITE• �7 5�� ,�t�r �i.�n /�a��/ Zip: S'S 3 3'�v Owner's Name: Le�y �'e.�s a c-�.ah Phone Number: 4rl -gyY-gyq9 Mailing Address: /So�L �.,y 7 uJ. City: �c.� /�R-o.:,� Zip: SS3 ys Contractor's Name: i ri �n c, Phone Number: 93z- 7Y6- S�� Mailing Address:/ZL .3 il/i u�l..,y . S. City: �i�rns�, Y4 Zip: ,S s33 7 SYSTEM DESCRIPTION HEATING SYSTEMS QL1�711t1ty: �� rt�Ge�IQIK.- f��''6��/�/Ks o��e�..� Make: �✓yiQ� ����►4 1�/` 14 �I/( -T Model: �Sa!'Vt YCl/�CJ�/�a�,O 3 S�I�/P✓a36'�t� ,�u�4�/4 N�/DO http://www.ci.orono.mn.us/mechanical%20permit.html 7/8/2003 CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Page 2 of 3 Fuel: !il/�r%��'�s �1/r4�'Gh S `'f/!9�GiE'!S Flue Size: a'Z � ���G. a� ��,l/!/ 3 �� U �-� Input BTUs: �G �+u G G G Gc D �t�G (/GO Output BTUs: 7 GU •_� .; fX+G' QD U�/� , CFM: j C��U !a OU f*,�, f�' COOLING SYSTEMS Quantity: (°::,�.� �...�,c'.;../'�1�!. ��'v��',��r�;,�r i'.'. Make: ` ✓� i - J�J`,/_jAl, j �— Model: ��-�/G�'x GS/� ';�.�./ G C"�t'� � Tons: �� «� �;�!... H.Power FIREPLACES Gas factory fireplace Wood buming factory fireplace with flue Wood Stove Wood stove with flue Brand Namc Model No. VENTILATION Na �Kitchen Exhaust � duct recalculating/�efm No. Bath E�aust(must have duct outside) cfin No. �Other Fans: Locations �ras7"P.� /S U cfin FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL) Installation or Removal Fuel oil: gallons underground inside outside LP Gas: gallons Other Gas opening PERMIT FEE CALCULATION(S) 2002 State Statute Yes This Section Applies 'Thc replacement of a Residential fixture or a�liance that meets all three of the following requirements: 1) Does not require modification to electrical or gas service. 2) Has a total cost of$500.00 or less; excludin�the cost of the fixture or appliance: and 3) Is improved,installed or replaced b_y the homeowner or licensed contractor. Skip next section; Cost of Pcrmit $ 15.00 State Surcharge $ .50 Mail-In Fee $ 1.50 If above does not apply, follow guidelines below: http://www.ci.orono.mn.us/mechanical%20permit.html 7/8/2003 CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT Page 3 of 3 1. Contract Price* is .0125%of job with a Minimum Fee of($35.00� 3 � 96s� x.0125 $ y�s! s� (contract price) (minimum$35.00) 2. State Surcharge. ** Add the State Building Code Division a Minimum Fee of($.50� - X.000s $ /8. 98 (contract price) (minimum$.50) 3. Postage and Handling(Only mail-in applications) $ 1.50 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ y9�•3y *CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor,profit,and other fixed costs.It is the amount to be charged to the customer for the work done.If any material,equipment,labor,or installation is furnished by the owner,tenant or any other party the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes.In the event that there is a dispute on the amount of the job cost,the City may request the submission of a signed copy of the actual contract. *'The STATE SURCHARGE is.0005 of the contract price under$1,000,000 or$.50-whichever is greater.For valuations over $1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit,agrees to do all work in strict accordance with the ordinances of the City and the regulatio f the Minnesota State Building Code, d certifies that all statements made on this application are complete,true and correct. Applicant's Signature: / Date: 7/8 �3 Approved By: Date: http://www.ci.orono.mn.us/mechanical%20permit.html 7/8/2003 LARKIN HVAC LOAD ANALYSIS for � LECY CONSTRUCTION ; ' 15012 HWY 7 WEST MINNETONKA MN 55345-3634 s_.>i...r�r Prepared By: CRAIG ANGELL ANGELL-AIRE 12245 NICOLLETAVE BURNSVILLE MN 55337 612-746-5200 03-27-2003 ---.:,_ _.- _- -- -------.._ -_ __. _ _ _ _ --- -- - ' RHVAC-Residentlal 8 Light Canmercial HVAC Loads Program � Elite Software Devebpment,inc. Argell-Alre IARKIN Eagan.MN 55123 ` ..> � .1:'` 03-27-2003 P�2 I ,. � . , , ., � ., , , . . . .. . - --� SV$}(3ry1..�'' ,1'�",. G�rk,`$+',�5 ,z ,4�'f/Ca,kr-�ti ��P•�, ,Y.."a�,. �.,>i�,xk .�.�vaG 1 �,.:,` 1�1C�•.i;".a� fi�e��,�?�dr '� l, -^n•�.. Y� ' �,`�,'.` `�. a ;� -_ _ �'�`.�/'� �i/ /Y C1'i�"!>.� ��i �l/ Component -� Area Sen. Lat. Sen. Total Description _ ___ Quan Loss Gain Gain___ Gain 3D Wndow Double Pane Low Emit Wood Frame 335 11,127 0 17,886 17,886 11 E Door Metal Urethane Core 42 734 0 212 212 12H Wa{I R-19+ 1/2"Gypsum Board(R-0.5) 1,283 7,081 0 2,047 2,047 15G Wall 5'or More Below Grade 8/12"BIk+R-11 760 3,007 0 0 0 16H Ceiling R-38 Insulation 1,440 3,444 0 1,760 1,760 21A Basemt Floor 2'or More Below Grade 1,872 4,133 0 0 0 Subtotals for stn�cture: 5,732 29,526 0 21,905 21,905 Active Peopfe: 0 0 0 0 0 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 0 0 Lighting: 0 0 0 0 0 p��: 0 0 0 0 0 Inflitration: Winter CFM: 156.2, Summer CFM: 52.1 377 15,341 839 1,278 2,117 Ventilation: WinterCFM: 52.1, SummerCFM: 52.1 0 5,114 839 1,278 2,118 Sensibte Gain Total: 24,461 Temperature Swing Multiplier. X1.00 ___ System Load Totals: 49,981 1,678 24,461 26,140 Chs,kA J i� � ._. . . ��� eck�i�ur'��se*�C+i�i , h .. . .. � , ,. . .. .n,m.., is i . + Supply CFM: 944 CFM per square foot: 0.285 Square feet of room area: 3,312 Square feet per ton: 1,251.068 t- < r af� ..� }�'3�SR�Ti+f4W., zwt..�t" '�S. °,�e1`;%��t��'� . r'+�y`��.�t"�,'�'�..�'�'�++"�".y\,�. . :_ ..� r.. , ��.5�(S��a.��.*�>._ yva `; {.,L '�§�� . i��'c�'n•t��?+� aa y x'.��....r�...�r��rz'p�,Pt�yfi,� -F..` !� ,k'�'�^n ��?'���' r ,.�. Total heating required with outside air: 49,981 Btuh 49.981 MBH Total sensible gain: 24,461 Btuh 94 % Total later�t gain: 1,678 Btuh 6 % Total cooling required with outside air: 26,140 Btuh 2.178 Tons(based on sensible+latent) 2.647 Tons(based on 77%sensible capacity) �, Nc�e�Y.�� ��. �..��ti Ca�ulations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent Ioads. Thursday,March 27,2003 � RHVAC-Residentlal&Ltght Commerciai HVAC Loads Program � ' Eiite Software Development,Inc. �� Angeil-Aire LARKIN � EaAan.MN 55123 �� �� � r;���� , �- z n;. t �:, .��03-27-2003 �_ , ; �r:: �.��._ 7`� . �; ;� � ��� Page 3 I ,,, r,. , Sy�Zem#2 5umt�cap� �41�r„ } �` � i'��' *�!d`�%� i x ry t, ;:i H r�,,^�'a i Y.,%n it.�..9�k 4'��F s�h'1% g` ,,7 F _�,.}�. Y»�µs�. F t ��?��a ; ' _--- '�l/-i/ K/ fV C�L/j�-/ I Component Area Sen. Lat. Sen. Total p��p�n _ _ Quan Loss Gain __ Gain Gain 3D Window Doubte Pane Low Emit Wood Frame 538 17,868 0 29,223 29,223 11 E Door Metal Urethane Core 42 734 0 212 212 12H Wall R-19+ 1/2"Gypsum Board(R-0.5) 1,622 8,954 0 2,589 2,589 15G Wall 5'or More Below Grade 8/12" BIk+R-11 414 1,638 0 0 0 16H Ceiling R-38 Insulation 1,960 4,688 0 2,395 2,395 21A Basemt Fbor 2'or More Below Grade 1,380 3,047 0 0 0 Subtotals for structure: 5,956 36,929 0 34,419 34,419 Active People: 4 0 920 1,200 2,120 Inactive Peopie: 0 0 0 0 0 Appliances: 0 0 0 0 0 ����: 0 0 0 0 0 Ductwork: 0 0 0 0 0 Infiltration: Winter CFM: 169.9, Summer CFM: 56.6 580 16,682 913 1,390 2,303 Ventilation: Winter CFM: 56.6, Summer CFM: 56.6 _ 0 5,561 _ 913 1,390 2,303 Sensibfe Gain Total: 38,399 Temperature Swing Multiplier: X1.00 _ System Load Totals: 59,172 2,746 38,399 41,145 Ctieck�igure��' r.,,.. . :.::;.�;.,��; .,�;, :, r �a �, •:� ,��.,�:-_, u ,z. 3.� �� .�. , Supply CFM: 1,508 CFM per square foot: 0.451 Square feet of room area: 3,340 Square feet per ton: 803.705 . ,:;: $a/S r�I�}��aS ti `. , r �� �,�. � � �� � . .� .��-� ., . .� ,...���, �,� .�, � v _ �,: .,�r��€.,�' ' Total heating required with outside air: 59,172 Btuh 59.172 MBH Total sensible gain: 38,399 Btuh 93 % Total latent gain: 2,746 Btuh 7 % Total cooling required with outside air: 41,145 Btuh 3.429 Tons(based on sensible+ latent) 4.156 Tons(based on 77%sensible capacity) NO�Q$ K4 �eg�:, �.� ''� t7� r��1ti' s' .trr��,:' ;fi } �'�s Q g �� �t�� �� '�l� �< Calcuiations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Tlwrsday,March 27,2003 —�------ g - ---- . � .. 032�3 ` �, , , ;:, RFNAC-ResidentJal�I�i ht Commercial HVAC Loads Pr ram Elite Sofiware Development,Inc. ' An9elt-Aire < E�,MN 5512:i` , ,_ �' ��.,; , �� � �, � , . Pa�e 4 � , �- •. � ,; . , -.� ., . :-.�- : I �.,, - -- --�, � `System#3 Summary.Lt�a, �"�? r�,�"s�;x�.� c�.,a" ��rhsyh`E�j,, Y ,:r �` '�'c;'.�r�'-�y.2*�� . '"€. ,2.� '" 1k��4°,1�'+'v�Cpfi`r;^aY '; ' " r�'J3n',Y;� !'�' r; �.z• , ..`v �ea��� (�7/hv' --- _ �-__- __�-'-1—.._ -- -— Component Area Sen. Lat. Sen. Total Description ____ Quan Loss Gain Gain Gain 15G Wail 5'or More 8elow Grade 8/12" BIk+R-11 1,530 6,052 0 0 0 16C Ceiling R-11 Insulation 648 5,246 0 2,680 2,680 21A Basemt Floor 2'or More Below Grade 648 1,431 ____ 0 _ 0 _____ 0 Subtotals for structure: 2,826 12,729 0 2,680 2,680 Active People: 0 0 0 0 0 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 0 0 ����yy; 0 0 0 0 0 Ductwork: 0 0 0 0 0 infiltration: Wir�ter CFM: 48.6, Summer CFM: 16.2 0 4,772 261 398 659 Ventilation: Winter CFM: 16.2, Summer CFM: 16.2 0 1,591 261 398 659 Sensible Gain Total: 3,476 Temperature Swing Multiplier. _ _ X1.00 _ S�stem Load Totals: 19,092 522 3,476 3,998 'Check Figures; '' ����=i�=- �� � � � Supply CFM: 234 CFM per square foot: 0.362 Square feet of room area: 648 Square feet per ton: 1,722.701 ,. ....�::. : .. . .. , - _.::,.,. .. . ��,yrqij" ���Ctr�'�'�, 4 � r System Lc,�au�. ��`� - ��h� Total heating required with outside air. 19,092 Btuh 19.092 MBH Total sensible gain: 3,476 Btuh 87 % Total latent gain: 522 Btuh 13 % Total cooling required with outside air: 3,998 Btuh 0.333 Tons(based on sensible+latent) 0.376 Tons(based on 77%sensible capacity) ;. � w�s.��� - .. ' ..: f{LL"a. !K�$xw�+� . . t@S Y " � �Ir�:'.• '�P o,�'w.�*��{�'S�E�ra���... '���''?J� - Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Ttx,�day.►�cr,2�,2003 RHVAC-Resfdenttai�Light Conunercial HyAC l.oads P�ogram � �`` �* �Ide Software Development,lnc. ' �elt-Aite > ' ', _ LARKlN� �� Eapan�MN 55123 03-27-2003 + ''° 2 ,� ' Page 5 �, ' �:,..:s . �� ,..F _�> � .. '� " 't;4c � .�_ e , �Y��..h �4���e�++' sw.,a'�.� �;! L F4 �d'�Y rv� �'� y t-� . � S stem#4 Summa oads , _ � �:_ �. � � :: ,LL u .� � ,,.. ,,. .:, .� � k Y . n►�-. �. .� , : � . , . r� cr �"�; -- -'�=�x ;;,, ;.���,,-- , . -'`I "",�f'� Component Area Sen. Lat. Sen. Total Description _ Quan Loss Gain Gain __ Gain 3D Window Double Pane Low Emit Wood Frame 60 1,842 0 2,520 2,520 11 E Door Metal Urethane Core 128 2,067 0 209 209 12H Wali R-19+ 1/2"Gypsum Board(R-0.5) 832 4,243 0 429 429 16H Ceiling R-38 Insulation 648 1,432 0 489 489 22B Slab on Grade 1" Edge Insulation(R-5) 102 3,555 0 0 0 Subtotals for stnicture: 1,770 13,139 0 3,647 3,647 Active People: 0 0 0 0 0 tnactive People: 0 0 0 0 0 Appliances: 0 0 0 0 0 Lighting: 0 0 0 0 0 Ductwork: 0 0 0 0 0 Infiltration: Wirrter CFM: 54.0, Summer CFM: 10.8 188 4,899 -176 58 -118 Verrtilation: Winter CFM: 10.8, Summer CFM: 10.8 0 980 -176 58 -119 Sensible Gain Total: 3,763 Temperature S1'ving Multiplier: X1.00 S�em Load Totals:__ _ 19,018 -352 3,763 3,410 Check Fi ures "� ' i ' � ' - - �, ° �x:�.�, ��. I •q ��#�'"k!�(�'.� ''�0. Fi-�i.�,,v#�t� .n.:^a"�Tr` ,•'�,�;w3?'l&n.. ��:;'� t,t''•.*�.�,r:.�r ��` � Supply CFM: 241 CFM per square foot: 0.373 Square feet of room area: 648 Square feet per ton: 1,591.312 � ,� ,� �, � .� , . � � �a� _. . .. ,. � .. _ System Loads. �.��{ � . _. � k , , . , .. . . .... ..21M1...: !�� �#�.��a '4Hi��Yij''NP.�.! '�,1Y ... ... �'�:.1�^,'�N�`A .w��'�.^. �.�Lr494i:,:. !:. .� , $�..'...� .Y. 'R:ni�Y'Y... 'Y', ' � ,f�.ii Total heating required with outside air: 19,018 Btuh 19.018 MBH Total sensible gain: 3,763 Btuh 110 % Total latent gain: -352 Btuh -10 % Total cooling required with outside air: 3,410 Btuh 0.284 Tons(based on sensible+ laterrt) 0.407 Tons(based on 77%sensible capacity) ' Notes I Calculations are based on 7th edition of ACCA Manual J. I All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Thursday,March 27,2003 _,� _ � T ___---------- _- — -- —— - — ---- - -----._____� ' RHVAC-Resident1a18 Ltght Commerc(ai HVAC Loads Program � ''-'� Efite Sa�tware Development,Inc. ' Mgell-AJre . - Y LARKIN I Eapan.MN 55123 03-27-2003 Page 6 ' �� .SyS��1r1 ZDa,ilp � ���m� � �g �„?brs'��x4 ' '•1{�K`�;v4roa'+tif'ii"�1X4�k� 3YP�YY "o-Y':w�r.ul a�i;.n�d R°°� vtlr�R�i,v �' �y �;,..:cA ,'�'. 'X�'�� f R.�c.��« �, '� �-„3�!'e��u.c� ?',�`i�f•i,�REo�ii�...dS*���l.'�:, r.,�%. . r_ ., . . . .. _ ... .. . -- _ �� fi� .r���:�/ _ — -- Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3D Window Double Pane Low Emit Wood Frame 220 7,307 0 11,812 11,812 11 E Door Metal Urethane Core 42 734 0 212 212 12H Wall R-19+ 1/2"Gypsum Board(R-0.5) 898 4,956 0 1,433 1,433 16H Ceiling R-38 Insulation ______ 1,440 3,444 0 1,760 ___1,760 Subtotals for structure: 2,600 16,441 0 15,217 15,217 Active People: 0 0 0 0 0 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 0 0 Lighting: 0 0 0 0 0 Ducfwork: 0 0 0 0 0 Infiltration: Winter CFM: 108.6, Summer CFM: 36.2 262 10,661 583 888 1,471 Ventilation: Winter CFM: 31.5, Summer CFM: 36.2 0 n/a n/a Na Na Sensible Gain Total: 16,105 Temperature Swing Multiplier: X1.00 Zone Load Totais: 27,102 583 16,105 16,688 Check Figures`. , ,�;. � �,:<t.,� �. � _>, Supply CFM: 656 CFM per square foot: 0.456 Square feet of room area: 1,440 Square feet per ton: 926.874 �' Zone Loads � - ' �� � �� � ; � =�:, Totai heating required with outside air: 27,102 Btuh 27.102 MBH Total sensibfe gain: 16,105 Btuh 97 °� Total latent gain: 583 Btuh 3 % Total cooling required with outside air: 16,688 Btuh 1.391 Tons(based on sensible+ latent) 1.554 Tons(based on 77%sensible capacity) Thursday,March 27,2003 i2HVAC-Residentfa!�L(ght Commercia{HVAG Loads Program � Elite Software Development,inc.1 Ar�ge1F-Aire CC M /�/y� LARKIN �I � ��� W�GJ Z -�.1 Y '� � '-) 1 Y I f�; . Q�27^2WJ . . 4 )� � ��� � , I �ys{,Gm A7 �QhP.A�.?�u�l,����;����d�4�k.c? � i � d <rc n .i:3' F'µ o y,ry. v�fY a.f;i3 .+�'3f t�4�:'3. � 4i1j �'" 3`�g�� fi' 3'rTf '� ��'� 2 �.. '� 't.: f -'�Y"i ��A U�.�i.. .�5�"s .,,.�:L a, .AIE".�r,< ,�'e.�1.�,j� �k '' r��,�,iy a,r�;:.��� �rt-' '�-� _ --- __ - � --------- - Component Area Sen. Lat. Sen. Total Descri�on __ Quan Loss Gain Gain Gain 3D Window Double Pane Low Emit Wood Frame 115 3,820 0 6,074 6,074 12H Wall R-19+ 1/2"Gypsum Board(R-0.5) 385 2,125 0 614 614 15G Wall 5' or More Below Grade 8/12" BIk+R-11 760 3,007 0 0 0 21A Basemt Floor 2' or More Below Grade 1,872 4,133 0 0 0 Subtotals for structure: 3,132 13,085 0 6,688 6,688 Active People: 0 0 0 0 0 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 0 0 Lighting: 0 0 0 0 0 Ductwork: 0 0 0 0 0 Infittration: Wirrter CFM: 47.7, Summer CFM: 15.9 115 4,680 256 390 646 Ventilation: Winter CFM: 20.6, Summer CFM: 15.9 0 n/a Na n/a n/a Sensible Gain Total: 7,078 T�rature Swing Mui�plier: X1.00 Zone Load Totals: 17,765 256 7,078 7,334 I � _ Check Figures ' - I �,�. � Supply CFM: 288 CFM per square foot: 0.154 Square feet of room area: 1,872 Square feet per ton: 2,741.989 � �Zone Loads � {" > �t=� � � � �., ,� z,. „��:; � ;� . ; ,,f. , , �.,ro: �, ,_. , .. ,._ .;:, ;o , _ . ,, ;:. � . � .. , �. , , , . � :. �:. � Total heating required with outside air: 17,765 Btuh 17.765 MBH Total sensible gain: 7,078 Btuh 97 % Total laterrt gain: 256 Btuh 3 % Total cooling required with outside air. 7,334 Btuh 0.611 Tons(based on sensible+latent) 0.683 Tons(based on 77%sensible capacity) Tiwrsday,March 27,2003 � RHVAC-Residantial 8�L(ght Commercial HVAC Loads Program � , � � Elite 3oftware Deveiopme�t,Inc. �' qnpeJ�-qire LARKIN li Eagan.MN 55123 � _ 03-27-2003 Page 8 �:. , , , __�. , , � ,2 ���,��,� , � :, :. j System#2 Zone#1 Sum[nary:�.pad�:� �Y� ����`"`"'�"` '� ��. .r� . �::�<< � � � � �L',�=�""� �, ,- ��--��rr,, ..y� -- ---- - �1 �- � � — -�- Component —y � Area Sen. Lat. Sen. Total Description ___ Quan _ Loss Gain Gain ___ Gain 3D Window Double Pane Low Emit Wood Frame 387 12,853 0 20,827 20,827 11 E Door Metal Urethane Core 42 734 0 212 212 12H Wall R-19+ 1/2"Gypsum Board(R-0.5) 1,0$9 6,012 0 1,738 1,738 16H Ceiling R-38 Insulation ____ 1,960 4,688 0 2,395 2,395_ Subtotals for structure: 3,478 24,287 0 25,172 25,172 Active People: 2 0 460 600 1,060 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 0 0 Lighting: 0 0 0 0 0 puctwo�ic: 0 0 0 0 0 Infiftration: Winter CFM: 125.7, Summer CFM: 41.9 429 12,339 675 1,028 1,703 Verrtilation: Wirrter CFM: 38.7, Summer CFM:41.0 0 n/a n/a Na____Na Sensible Gain Total: 26,800 Te�rature Slnring Muftiplier: X1.00 _____ Zone Load Totals: 36,626 1,135 26,800 27,935 ' Check Figures -�, ... ... ;.. . �. Supply CFM: 1,092 CFM per square foot: 0.557 ' n: 74 . 1 S uare feet er to 5 682 S uare feet of room area: 960 q , q P I Zone Loads. `� r .�, ,,,�',, �. Total heating required with outside air: 36,626 Btuh 36.626 MBH Total sensible gain: 26,800 Btuh 96 % Total latent gain: 1,135 Btuh 4 % Total cooling required with outside air: 27,935 Btuh 2.328 Tons(based on sensible+ latent) 2.628 Tons(based on 77%sensible capacity) Thursday,March 27,2003 ,.._.—.— - ---— ____�_—____—____—_.__.—��T--- -- — , ----- ---- ---. � RHVAC-Residentlai�Ltght Gommercial HVAG�oads Program � Ellte Software Llevebpment,Inc. I Ar�gell-Aire �� LARKIN � Eapan.MN 55123_ 03-27•2003 �-- ------ Pape 9 � , � _ ,, $�/S�t11�2�O�IB�i S�,lilllt7s9�1 L.OaCIS � ��`? �4,^�,.da �r'��5�..�a,�,a,,>fiir..�S`��... . -+�.r".a, ,,,,�,r�g �:'•a,� u`�'� ' 'x.'_�r, ��' �^�� n � ' . �� �,. � .. - -- '- - �'��: �.IC��('�C�� t�G'���_"'��J�//�!S __ - ----------- Component Area Sen. Lat. Sen. Total I Descri�tion _ ___ Quan Loss Gain Gain Gain --- -- --- --_ 3D Window Double Pane Low Emit Wood Frame 151 5,015 0 8,396 8,396 12H Wall R-19+ 1/2"Gypsum Board(R-0.5) 533 2,942 0 851 851 15G Wall 5'or More Below Grade 8/12" BIk+R-11 414 1,638 0 0 0 21A Basemt Floor 2'or More Below Grade 1,380 3,047 0 0 0 Subtotals for stn�cture: 2,478 12,642 0 9,247 9,247 Active People: 2 0 460 600 1,060 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 0 0 Lighting: 0 0 0 0 0 Ductwork: 0 0 0 0 0 Infiltration: Winter CFM: 44.2, Summer CFM: 14.7 151 4,343 238 362 600 Ventilation:Winter CFM: 17.9, Summer CFM: 15.6 0 Na n/a n/a n/a Sensible Gain Total: 10,209 Temperature Swing Multiplier. X1.00 _ Zone Load Totais: 16,985 698 10,209 10,907 I T � �Check Figures ' f�.��� F �` ` ° , ��� � � r� Y;'�;v� Supply CFM: 416 CFM per square foot: 0.301 Square feet of room area: 1,380 Square feet per ton: 1,261.717 I i y i. 6 I ' Zone Loads � � _� v ,. ,,., ,�,. �� ; ! Total heating required with outside air: 16,985 Btuh 16.985 MBH Total sensible gain: 10,209 Btuh 94 �o Total latent gain: 698 Btuh 6 % Total cooling required with outside air: 10,907 Btuh 0.909 Tons(based on sensible+ latent) 1.094 7ons(based on 77%sensiale capacity) Thursday,March 27,2003 ' RH1/AC-Residential d,L(ght Commercial HVAC Loads Program � '" ' ` Ellte 5oftware Development,Inc. i Ar�geil-A1re lARK1 N F�Aar►�MN 55123" ,` �, ' R�, ,':a s�-�; 03,27-2003 ` ..� Page 9 � ' i � _;. �.-: z .. ,.;.., ' ' �System#3 Zon� � �� . ,,. .. : �� +r��� �, �,' ,� ����� a � ' '`.k 1�'r'`��_;w a �����?f,,�. ::: , . �`-r'�'� Componen� Area Sen. Lat. Sen. Totai Description Quan Loss Gain Gain _ Gain 15G Wall 5'or More Below Grade 8/12" BIk+R-11 1,530 6,052 0 0 0 16C Ceiling R-11 Insulation 648 5,246 0 2,680 2,680 21A Basemt Floor 2'or More Below Grade 648 1,431 0 0 0 S�totats for structure: 2,826 12,729 0 2,680 2,680 Active Peopie: 0 0 0 0 0 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 0 0 Lighting: 0 0 0 0 0 Ductwork: 0 0 0 0 0 Infiltration: Winter CFM:48.6, Summer CFM: 16.2 0 4,772 261 398 659 Ventilation: Winter CFM: 16.2, Summer CFM: 162 0 Na n/a Na Na Sensible Gain Total: 3,078 Temperature Swing Multipi�r: _ X1.00 Zone Load Totals: 17,501 261 3,078 3,339 Check Figures�;� • .; . , �:'t�' _ � , , .;. ,_: , . ,__ �.�.,� . , , ..,::. ,,,..,.� Suppfy CFM: 234 CFM per square foot: 0.362 Square feet of room area: 648 Square feet per ton: 2,161.77 ., . _>. . ��...��� �u� � � . .r '` �+'���rrr +fi,� ti.�r+'�'kh'h�'Fi.. �� �� ZO(16�.01d8 r,�x�.RaYt�'�'��' . ... ..., .' `��M;��R^���z'��z'��rc', . .' i .v�{, Total heating required with outside air: 17,501 Btuh 17.501 MBH Tot�al sensible gain: 3,078 Btuh 92 % Total latent gain: 261 Btuh 8 % Total cooling required with outside air: 3,339 Btuh 0.278 Tons(based on sensible+latent) 0.300 Tons(based on 77%sensible qpacity) TFxusday,March 27,2003 f--.—� --- -- — — ----�____— ' RFNAC-ResWential&Light Commercial HVAC Loads Program '� � ` `` �Uta$�twaro Uev,eiqpmant,'inc.� A�lgetl-Aile � � �� • tii �` ��°�' " v��r'- LARKIN � Ea�an.MN 55123 s 03-27-2003" ' Peee 10 I , , ., '� � � �' � . � System#4Zone#1 Summary Loads' t;�,�+�'f"r�,-�����`��'�� �;���� ' ��°����� ���� ,�'"�`� � " � �'� _.g,, � . .� �11�_F�j-l�� �.1//_��Y i =J/`�G/��¢/��1��. II � '_' �.�-_ � _. -__.- -_._..___-- '_-- Component ` Area Sen. Lat. Sen. Total Descnption _ Quan Loss Gain Gain Gain 3D Windaw Double Pane Low Emit Wood Frame 60 1,842 0 2,520 2,520 11E Door Metai Urethane Core 128 2,067 0 209 209 12H Wall R-19+ 1/2"Gypsum Board(R-0.5) 832 4,243 0 429 429 16H Ceiling R-38 Insulation 648 1,432 0 489 489 226 Slab on Grade 1" Edge Insulation(R-5) 102 3,555 0 0 0 Subtotals for structure: 1,770 13,139 0 3,647 3,647 Actnre People: 0 0 0 0 0 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 0 0 Lighting: 0 0 0 0 0 Ductwork: 0 0 0 0 0 Infiitration: Winter CFM: 54.0, Summer CFM: 10.8 188 4,899 -176 58 -118 Ventilation: Winter CFM: 10.8, Summer CFM: 10.8 0 Na Na Na n/a Sensible Gain Total: 3,705 T�rature Swing Multiplier: X1.00 Zone Load Totals: 18,038 -176 3,705 3,529 Check Figures ,��'�`�: x�M _ ;,z���, .,. , � Supply CFM: 241 CFM per square foot: 0.373 Square feet of room area: 648 Square feet per ton: 1,822.688 , ,.� I �� � 3_ >'�_. : R �..- . -:. I z0l1@�.Oa(�$ �>9'�z�°� '�: � , �� ��� � �;� �:a�t �ri>Ln r.;R-r� 'a.��r�': t� ,:.mi�rd �^ .t�.r:e� c„3�n'n� ,¢�sw.�w ' u:. �:. y., � Total heating required with outside air: 18,038 Btuh 18.038 MBH Total sensible gain: 3,705 Btuh 105 % Total �aterrt gain: -176 Btuh -5 % Total cooling required with outside air: 3,529 Btuh 0.294 Tons(based on sensible+latent) 0.356 Tons(based on 77% sensible capacity) Thursday,March 27,2003 ✓ DAT TIME CITY OF ORONO CALLED IN Z �-� INSPECTION NOT E SCHEDULED -�� ::�'C� PERMIT N0. '��5�� COMPIETED ADDRESS Z'"'7�C' f�2 eQ 2,�`-n�TrL �' OWNER CONTR. ��- � �re- TELEPHONE N0. ��`� ��� J Z O� � DESCRIPTION �� `�'�"e ���� � Ot FOOTING 11 MECHANICAL RI 18 EXCAV/GRADING/FILLING Q 02 FRAMING 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS y 03 INSULATION 24/25 WO00 BURNER/FIREPLACE 34 TREE REMOVAL Z04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Q 05 FINAL 14 SEWER HOOK-UP O6 PROGRESS � 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT v 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP = 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL v 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL � OWNER/CONTRACTOR TO MEET YOU:�YES_NO � COMMENTS: � W 0. � � O � � O � W � Q � 2 W � W � � � �RKSATISFACTORY:PROCEED ❑ PROJECTCOMPLETE W �O CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY � ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY � BEFORE COVERING PERMANENT ❑CORRECTUNSAFECONDITIONWITHIN HOURS. p pHOTOTAKEN INSPECTOR WILL RETURN ❑CITATION ISSUED ❑STOP ORDER POSTED.CALL INSPECTOR O INSPECTION REQUIRED.CALLTO ARRANGE ACCESS. Call forthe n t inspection 24 hours in advance. (952� 249-46�� OwnedCont l te: Inspector. �` White Copyllnspector's F e Canary CopylSite Notice �s�1 p E ,� / J �3 TIM E V CITY OF ORONO CALLED IN 7 dG INSPECTION N TICE SCHEDULED 7- /'— O3 /.`30 PERMIT N0. S/ COMPLETED ADDRESS `�7 � t� �-�-�^�� Ti^ OWNER CONTR. �� E'-� ��'' �� TELEPHONE NO. �5/- ��� - �9 S'3 � DESCRIPTION ��{C� �l� �Pc`'�— � 01 FOOTING 1 MECHANICAL RI 18 EXCAV/GRADING/FILLING Q 02 FRAMING 13 ECHANICAL FINAL 19 LAKESHORE/WETLANDS y 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL Z 04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Q 05 FINAL 14 SEWER HOOK-UP 06 PROGRESS � 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT � 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP = 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL J 10 PLUMBING FINAL `/ 36 FOUNDATION/REMOVAL � OWNERICONTRACTOR TO MEET YOU:V YES_NO � COMMENTS: � W � � J O >. � O � W � Q � Z W � W � � � d W� WORK SATISFACTORY:PROCEED ❑ PROJECT COMPLETE W ❑ RRECT WORK 8 PROCEED ❑ISSUE CERTIFICATE OF OCCUPANCY � ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY � BEFORE COVERING PERMANENT ❑CORRECTUNSAFECONDITIONWITHIN HOURS. p pHOTOTAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR ❑CITATION ISSUED O INSPECTION REQUIRED.CALLTO ARRANGE ACCESS. Cail for the ne t inspection 24 hours in advance. (g52) 249-4600 OwnedContr o �ite: Inspector. ����""� White Copyllnspector's File Canary Copy/Site NoUce �5�� � �fa .. DATE TIME CITY OF ORONO CALLEO IN INSPECTION��l�s.�� SCHEDULED 7 a/-�3 /:.3C� PERMIT N0. � COMPLETED ADDRESS `��� � ��-�' �� �r �- OWNER CONTR. ����� �`�' � � TELEPHONE NO. � DESCRIPTION ���' ' �-� �sf �� � 01 FOOTING 11 CHANICAL I 18 EXCAV/GRADING/FILLING Q 02 FRAMING 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS y 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL Z 04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Q 05 FINAL 14 SEWER HOOK-UP O6 PROGRESS � 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT J 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP = 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL J 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL � OWNERICONTRACTOR TO MEET YOU:_YES_NO � COMMENTS: � W � � � O >. � O � W � Q � Z W � W � � d W� WORK SATISFACTORY:PROCEED ❑ PROJECT COMPLETE W ❑CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY � ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY � BEFORE COVERING PERMANENT ❑CORRECTUNSAFECONDITIONWITHIN HOURS. p pHOTOTAKEN INSPECTOR WILL RETURN ❑CITATION ISSUED ❑STOP ORDER POSTED.CAIL INSPECTOR ❑ INSPECTION REQUIRED.CALLTO ARRANGE ACCESS. Call for the ne inspection 24 hours in advance. (952� 249-46�� OwnerlContr r s te: Inspector. White Copy/lnspector's Fi Canary Copy/Site Notice ����� � ✓ DATE TIME CITY OF ORONO CALLED IN INSPECTION ,,ZI� / SCHEDULED � �G'O PERMIT NO. L COMPLETED r� �� ADDRESS � �i �'� �1'l OWNER CONTR. TELEPHONE NO. _ ��Z 7��t S � � DESCRIPTION ���Y , C��� �� � � � 01 FOOTING 11 MECHANICAL RI 18 EXCAV/GRADI LLING Q 02 FRAMING 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS y 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL Z 04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Q 05 FINAL 14 SEWER HOOK-UP O6 PROGRESS � 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT � 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP = 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REMOVAL J 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL � OWNEHICONTRACTOR TO MEET YOU:_YES_NO � COMMENTS: � W � o � ���� I � -C� a � 0 � W � Q � 2 W � W � � d �ORKSATISFACTORY:PROCEED ❑ PROJECTCOMPIETE W ❑CORRECT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY � ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY � BEFORE COVERING PERMANENT ❑CORRECTUNSAFECONDITIONWITHIN HOURS. p pHOTOTAKEN INSPECTOR WILL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR �CITATION ISSUED ❑ INSPECTION REQUIRED.CALLTO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (952) 249-4600 OwnerlContrac Inspect � � l White Copy/lnspector's File Canary CopylSite Notice C�� ��� DATE TIME CITY OF ORONO CALLEO IN INSPECTION N TICE SCHEDULED g-9-o3 !U=�� PERMIT N0. 0 �� _ COMPLETED ADDRESS a 7�Z� �1� %�-u�'t �/� OWNER CONTR. TELEPHONE N0. g� Z 77-�v �ZU� � DESCRIPTION �ir TP�Sf-- ��S L�.� �-d'y G'e��� � 01 FOOTING ' 11 MECHANICAL RI 18 EXCAV/GRADING/FILLING Q 02 FRAMING 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS y 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL Z04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION Q OS FINAL 14 SEWER HOOK-UP O6 PROGRESS � 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPLAINT � 07 DEMO-FINAL 15 SEPTIC INSTALL. 22 FOLLOW-UP = 09 PLUMBING RI 23 SEPTIC FINAL / 35 HARD COVER REMOVAL J 10 PLUMBING FINAL / 36 FOUNDATION/REMOVAL Z OWNERICONTRACTOR TO MEET YOU:_YES�NO � COMMENTS: � W a o C7 l S -- f��'P� � ° �e- �(, VlS +L ���. W � Q � Z W � W � � d W� ❑WORKSATISFACTORY:PROCEED ❑ PROJECTCOMPLEfE W ❑C RECT WORK 8 PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY � CORRECT WORK,CALL FOR REINSPECTION TEMPORARY � BEFORECOVERING PERMANENT ❑CORRECTUNSAFECONDITIONWITHIN HOURS. ppHOTOTAKEN INSPECTOR WILL RETURN �CITATION ISSUED ❑STOP OR�ER POSTED.CALL INSPECTOR ❑ INSPECTION RE�UTAED.CALLTO ARRANGE ACCESS. Call forthe next i spection 24 hours in advance. (952� 249-46�0 OwnerlContrac s te Inspector. White Copyllnspector's File Canary CopylSite Notice