HomeMy WebLinkAbout2009-00777 (Mechanical) • � CITY OF ORONO PERMIT NO.: 2009-007�
2750 KELLEY PARKWAY ;
ORONO, MN 55356- �ATE �SsuEn: 1UO3/�09
952 249-4600 FAX: 952 249-4616
ADDRESS : 2240 ABINGDON WAY
PIN : 03-117-23-23-0009
LEGAL DESC : ABINGDON GLEN
: LOT 007 BLOCK 001
PERMIT TYPE : MECHANICAL(>$500)
PROPERTY TYPE : RES[DENTIAL
CONSTRUCTION TYPE : MECHANICAL- MULT[PLE
VALUATION : $ 35,000.00
NOTE: GEOTHERMAL SYSTEM
2 WATER FURNACE-F.,LECTRIC
1 TR]ANGLETUBE GAS HEATING SYSTEM
2 WATERFURNACE 5 T AC
APPLICANT MECHAN[CAL 437.50
UMR GEOTHERMAL STATE SURCHARGE MECH (VALUAT[ON) 17.50
5115 INDUSTRIAL STREET
MAPLE PLAIN, MN 55359 MAIL-IN FEE 2.00
(763)479-6325 MISC FEE 0.00
TOTAL 457.00
OWNER
MUELLER,JOHN&KIMBERLY
2240 AB[NGDON WAY
LONG LAKE, MN 55356-
AGREEMENT AND SWORN STATEMENT
The work for which this permit is issucd shall be performed according to
the approved plans and specifications,applicable City approvals,and the
State Building Code. This permit is for only the work described and does
not grant permission for additional or related work which requires scparate
permits. All provisions of laws and ordinances governing this type of work
shall be compied with whether or not specitied herein.This permit will
expire and become null and void if construction authorized is not
commenced within 180 days of the da[e of issuance,or if construc[ion is
suspended for a period of]80 days at any time after work has commenced.
The applicant is responsible for assuring all required inspections are
requested in conformance with[he State Building Code.This permit may be
revoked at any time for due caus .
-�1� � // � 0�3i0 � //O � O
Applicant Permrtee Signature Date ' ss e y Signature Date
SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE.
� �
�
u ' • m
�
. ,
�
i a
FOR CI Y USE ONLY
,¢�� City of Orono f/ �
P.O.Box 65 Date Received: � Permit# ��_� � �
� �"` 2750 Kelley Parkway
a �: �- ��' Crystal Bay,MN 55323 Approved By: Amount$:
��x�o+`ti���� (952)249-4600 _ d�j�
�l`� ' � �
CITY OF ORONO—MECHANICAL PERMIT
(All Commercial permits must be approved by[he Building Ofticial or Inspector and/or Fire Marshall)
GENERAL INFORMATION �
1. You may apply for mechanical permits by mail or in person at the City offices. Applications will
be reviewed and a permit will be issued within two working days.
2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT
VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE
PERMIT CARD IS POSTED ON THE JOB SITE.
3. Mechanical Desiens—Complete calculations,details and specifications are required for each
heating,ventilation,humidification-dehumidification,and air condition' g installation including
heat iossiheat gain caicuiation,design temperatures,equ;pn-,e,it.ating�u;denti:cation as t�
type, manufacturer and model. Data shall be presented on form provided.
4. When any new construction or remodeling is involved,a separate building permit must be
obtained.
5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code
requirements.
6. All work must be inspected(rough-in and final). Call(952)249-4600.
(24-48 hour ootice required)
7. House Heating Test Record must be submitted before final.
TYPE OF PERMIT
(Check All That A�p�__ ___
�✓ Residential � Commercial(Appro�al Requiredl
❑ New 0✓ Additional ❑ Repairs ❑ Replace
Job Site/Owner Information:
Site Address: 224�Abingdon Way
Owner: Kimberly Mueller Mailing Address: 2249 Abingdon Way
City: urono Z�p: 5b:i56
Home Phone: �952)476-0358 Alternate Phone:
Contractor Information:
Contractor: UMR Geothermal, Inc. Contact Person: Pat Hughes
Address: 5115 Industrial Street State Bond#: 929289728
Maple Plain 55359 09/16/10
City: Zip: Expiration Date:
Phone: (�63)479-6325 Alternate Phone: (651) 336-9445
Q Insurance—Current: 09/01/10
1
r �:� ��
r
m
. �
�
�
MECHAIVICAL SYSTEMS BEING INSTALLED ' '''' !'
Note: All Geothermal Systems will now require a Site Plan& Review by our Building Official.
IS THIS GEOTHERMAL? ❑✓ Yes ❑ No
HEATING SYSTEMS
Quantity: 2 �
Make:
WaterFurnace TriangleTube
NDV064A Solo 175
ModeL•
Fuel: Electric Gas
Flue Size: N/A 3" PVC
Input BTUs:
1750G�
Output BTUs: 164000
CFM: 2000
COOLING SYSTEMS
Quantity: 2
Make: WaterFurnace
Model:
N DV064A
Tons: 5
H.Power
FIREPLACES
❑ Gas Factory Fireplace Brand Name:
❑ Wood Burning Fireplace
� Wood Stove Model No.:
❑ Wood Stove With Flue
VENTILATION
❑ No. Kitchen Exhaust duct recirculating cfm
❑ No. Bath Exhaust(must have duct outside) cfm
❑ No. Other Fans: Locations cfm
FUEL STORAGE (Must be approved 6y Fire Marshall iJproposing to nbandon tank in place.)
� Installation a Removal
Fuel Oil: gallons ❑ Underground � Inside �Outside
LP Gas: gallons
Other:
GAS LINE ONLY
❑ Outdoor Grill � Other/List What&Where: Boiler
2
• , 1' ,
. ,
�
�
PERMIT FEE CALCULATION(S)
BASED OFF-2002 STATE STATUE
❑ Yes,this section applies
The replacement of a Residential fixture or appliance that meets all three of the following requirements:
1. Does not require modification to electrical or gas service.
2. Has a total cost of$500.00 or less;excludine the cost of the fixture or appliance:and
3. Is improved, installed or replaced by the homeowner or licensed contractor.
Skip next section,if this applies; Cost of Permit $ 15.00
State Surcharge $ .50
Mail-In Fee(If Applicable) $ 2.00
Total Permit Fee $
PERMIT FEE CALCULATION S -JOBS OVER$500.00
If above does not apply;follow guidelines below:
1. CONTRACT PRICE * is 1.25%of contract price with a(Minimum Fee of$50.00)
35,000.00 x.0125 $ 437.50
(contract price) (minimum$50.00)
2. STATE SURCHARGE ** Add the State Bldg Code Div. Surcharge(Minimum Fee of�.50)
35,000.00 x .0005 $ 17.50
(contract price) (minimum$ .50)
3. POSTAGE&HANDLING(Only on Mail-In Applications) $ 2.00
4. TOTAL PERMIT FEE(Add Lines 1-3 Above) $ 457.00
■ * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the
permitted work including materials, labor,profit, and other fixed costs. It is the amount to be charged
to the customer for the work done. If any material, equipment, labor or installations are furnished by
the owner, tenant or any other party, the reasonable market value of such items must be added to the
estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the
amount of the job cost, the City may request the submission of a signed copy of the actual contract.
■ **The STATE SURCHARGE is.0005 of the Building Department at(952)249-4600 for the price.
MECHANICAL PERMIT APPLICATION AGREEMENT
The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all
work in strict accordance with the ordinances of the City and the regulations of the State of
Minnesota, and certifies that all statements made on this application are complete, true and
correct.
Applicant's Signature: ', Date: 10/28/09
Reset Form
3
, ;
� �.�
+ a
� �
,,� �' ,�'
� � � ��
w �
t�/ �� �
i� �^ �
I � J �
I �_ `
, �
� I
I
�
V �
�
' � '
� �
� ' �"�� ,�--�
� -�� �.., I � _ ;.�:
,
.� � ;, ,
��., t � � � � ��
�J �,
J '
� I �, �
� �, �c�
� � �
l
�`--- �—- /�----_. -J �
'_- � � ' � /� �_= �
I ,� � �
� ;` �r��
�
_ ,,� ;
_ r `_ �'
�° � j - - ._ �
�� � � ,� -
�
_� � � � �.__ _�:i,�)� '
� -- � - ���
, � � �
� � �
�_
.�, = � �� �> � �, ,
, ;
,� � � �, ��. � G ,
� �'= �'�r �
� � �
,
�� �� � .
� �� � -- � I
._� ��� �
� '� \ "
� �
� � �
�. � � ��Cy �`
\v �
� � _
� C� v � .
� Q �
�
• N
n
. pp
7
�
I $
�
�
�
�
I
Kimberly Mueller
HVAC Load Calculations
for '
Muler �'
I
� ',
I
�
Prepared By: '
Chad Alsaker
UMR Geothermal, Inc.
5115 Industrial Street
Maple Plain MN 55359
763 479-6325
Thursday, October 29, 2009
� Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. ,
Uppe�Midwest Radiant � Kimberly Mueller
Maple Plain, MN 55359 �,� Page 2
Project Report
--- -- - - _ - ---
_ _ -: - - — _ _ _ �� ��-�� �. ,-�--, ��, i
General Pro�ect Information • �� •� ' � ' � ��
- - -- - --_ --- -- -- - ---- - -
Project Title: Kimberly Mueller
Designed By: Chad Alsaker
Project Date: 7-13-09
Client Name: Muler
Company Name: UMR Geothermal, Inc.
Company Representative: Chad Alsaker
Company Address: 5115 Industrial Street
Company City: Maple Plain MN 55359
Company Phone: 763 479-6325
Company Fax: 763 479-2183
Company E-Mail Address: chad@umrgeothermal.com
Company Website: www.umrgeothermal.com
- -
- -- --- --. _.. ----
Dasign Data
--- _ __ _ -- --- - — - - --
Reference City: Minneapolis, Minnesota
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation: 834 ft.
Altitude F,�ctor: 0.970
Elevation oensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Outdoor Outdoor Indoor Indoor Grains
Drv Bulb Wet Bulb Rel.Hum Drv Bulb Difference
Winter: -12 0 30 72 34
Summer: 89 73 50 75 34
Check Figures _. __ _ . _ _ _ ___ ,I
_ _
Total Building Supply CFM: 3,306 CFM Per Square ft.: 0.399
Square ft. of Room Area: 8,281 Square ft. Per Ton: 841
Volume (ft3) of Cond. Space: 81,445
_ _ - -- _ _... __ --_ - __ _ _ - --
Building Loads
----— - - ---- ----- -- - - ---
Total Heating Required Including Ventilation Air: 113,561 Btuh 113.561 MBH
Total Sensible Gain: 88,618 Btuh 92 %
Total Latent Gain: 7,404 Btuh 8 %
Total Cooling Required Including Ventilation Air: 96,022 Btuh 8.00 Tons (Based On Sensible+ Latent)
9.85 Tons (Based On 75°/o Sensible
', Capacity)
Notes
__- -- - __ ___. _ _
_ - -------- -
--- -- ---- - - __ _ - -----
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
i
�
�
G:\UMR\Elite load calcs\Muler.rhv Thursday, October 29, 2009, 7:20 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Develo ment,Inc�
.
� Upper Midwest Radiant � Mueller
Maple Plain,MN 55359 _� age 3
Load Preview Report ' Q ��
I� Has Net Recl ft.� i Sen Lat Net Sen'; Hts CIS Act! Duct
-op _ __ -_ ___ ._ __ I' __ ' Gain'i__ Gain�l Gain Loss _ 9 9 Size
I � CFM CFM CFM
Sc e _ _ , A_DJ - on on; on rea--- - -___ _ _ _ ____---- -
Building 8.00 9.85 841 8,281 88,618 7,404 96,022 113,561 2,601 3,306 3,306
System 1 No 8.00 9.85 841 8,281 88,618 7,404 96,022 113,561 2,601 3,306 3,306 6ac11
Ventilation 418 2,479 2,897 2,510
Humidification 7,275
Zone 1 3,458 21,262 1,425 22,687 32,890 824 797 797 12x11
1-Basement 3,458 21,262 1,425 22,687 32,890 824 797 797 7�
Zone 2 3,458 51,986 1,700 53,686 45,812 1,148 1,948 1,948 32x11
2-Main 3,458 51,986 1,700 53,686 45,812 1,148 1,948 1,948 18-6
Zone 3 1,365 14,953 1,800 16,753 25,074 629 560 560 9x11
3-2 Floor 1,365 14,953 1,800 16,753 25,074 629 560 560 5�
� '
� �
i
I
G:\UMR\Elite load calcs\Muler.rhv Thursday, October 29, 2009, 7:20 AM
# • ' ' �
- -- ----
Rhvac Residential 8 Light Commercial HVAC Loads Elite Software���ent,Inc�
Upper Midwest Radiant '� KQnb Mueller
Maple Plain, MN 55359 � Page 4
Total Building Summary Loads
Component Area Sen Lat Sen Totall
Description Quan Loss Gain Gain Gain ',
- _ _ _ _ __
3A-w-o: Glazing-Double pane low-e (e = 0.40), operable 290 12,910 0 15,597 15,597
window, wood frame, u-value 0.53, SHGC 0.61
3A-w-o: Glazing-Double pane low-e (e = 0.40), operable 867 25,489 0 45,460 45,460
window, wood frame, u-value 0.35, SHGC 0.61
15611-Ow-8: Wall-Basement, , framing with R-11 sill to 1041 4,878 0 107 107
floor in 2 x 4 cavity, core, no board insulation, plus
interior finish, wood studs, 8'floor depth
12E-Osw: Wall-Frame, R-19 insulation in 2 x 6 stud 5052 28,858 0 5,632 5,632
cavity, no board insulation, siding finish, wood studs
166-44: Roof/Ceiling-Under Attic with Insulation on Attic 3458 6,391 0 3,727 3,727
Floor(also use for Knee Walis and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shinales �r Dark Metal, Tar and Gravel or
Membrane, R-44 insulation
21A-32: Floor-Basement, Concrete slab, any thickness, 2 3458 5,809 0 0 0
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 32'wide
Subtotals for structure: 84,335 0 70,523 70,523
People: 4 800 920 1,720
Equipment: 1,600 1,450 3,050
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 217, Summer CFM: 114 19,441 2,525 1,706 4,231
Ventilation: Winter CFM: 112, Summer CFM: 112 2,510 2,479 418 2,897
AED Excursion: 0 0 13,601 13,601
Humidification (Winter) 19.84 gal/day : 7,275 0 0 0
Total Building Load Totals: 113,561 7,404 88,618 96,022
__ _ _ - _ - -
Check Figures _ __ . _ J
-- - -- _ - - _____ -- -__-- -__ _ _-- ---
Total Building Supply CFM: 3,306 CFM Per Square ft.: 0.399
Square ft. of Room Area: 8,281 Square ft. Per Ton: 841
Volume (ft') of Cond. Space: 81,445
Building Loads ' '
Total Heating Required Including Ventilation Air: 113,561 Btuh 113.561 MBH
Total Sensible Gain: 88,618 Btuh 92 %
Total Latent Gain: 7,404 Btuh 8 %
Total Cooling Required Including Ventilation Air: 96,022 Btuh 8.00 Tons (Basea Un Sensible+ Latent)
9.55 Tons (Based On 75% Sensible
Capacity)
_ _ _._ _ __ _ __ _. _ _
Notes
__ __- ------._ ___ _ _ __
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
' �
G:\UMR\Elite load calcs\Muler.rhv Thursday, October 29, 2009, 7:20 AM
/
/ /
��f � DAT 3 TI E V
� CITY OF ORONO CALLED IN /Z n
INSPECTION OTI E SCHEDULED IZ- D ���
PERMIT NO.���OD���COMPLETED
ADDRESS �� � ��
OWNER CONTR. �`�G�
TELEPHONE NO. �5�- �' ����'
� DESCRIPTION �
� ❑ FOOTING ❑ fv1ECHAN RI ❑ EXCAV/GRADING/FILLING
Q ❑ FRAMING ❑ MECHAN A�FINAL ❑ LAKESHORE/WETLANDS
y ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ TREE REMOVAL
Z ❑ WALL BD. ❑ WATER HOOK-UP ❑ SITE INSPECTION
Q ❑ FINAL ❑ SEWER HOOK-UP ❑ PROGRESS
� ❑ DEMO-SITE ❑ SEPTIC MAINT. ❑ COMPLAINT
� ❑ DEMO-FINAL � SEPTIC INSTALL. ❑ FOLLOW-UP
_ ❑ PLUMBING RI ❑ SEPTIC FINAL ❑ HARD COVER REMOVAL
� ❑ PLUMBING FINAL ❑ FOUNDATION/REMOVAL
� OWNER/CONTRACTOR TO MEET YOU:_YES_NO
� COMMENTS:
�
W
a
o �.� ��, "� �'
�
�
0
�
W
�
Q
�
Z
W
�
W
�
j
� ❑WORK SATISFACTORY:PROCEED �ROJECT COMPLETE
W ❑COFRECT WORK&PROCEED � ISSUE CERTIFICATE OF OCCUPANCY
O C CORRECT WORK,CALL FOR REINSPECTION TEMPORARY
V BEFORECOVERING PERMANENT
❑CORRECTUNSAFECONDITIONWITHIN HOURS. C pHOTOTAKEN
INSPECTOR WILL REfURN ❑CITATION ISSUED
❑STOP ORDER POSTED.CALLINSPECTOR
❑ INSPECTION REQUIRED.CALL TO ARRANGE ACCESS.
Call for the next inspection 24 hours in advance. �952� 249-46��
OwnerlContractor on site:
Inspector. � .� �1—'Lc
White Copyllnspector's File Canary Copy/Site Notice