Loading...
HomeMy WebLinkAboutseptic info �O� 0 � E 0 CITY OF ORONO s. � ' Municipal Offices , rl S,� r�,, ,,8`�` �, Street Address Mailing Address: � G'�' 2750 Kelley Parkway P.O. Box 66 'Z9 �i Orono,MN 55356 Crystal Bay, MN 55323-0066 kESH�4 To: The Current Owner of Address 450 DEBORAH DR City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes �No If yes, please contact the Onsite Systems Manager at 954-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non-Compliant Yes �No If yes, system must be brought into compliance by: December 31, 2007 December 31, 2010 Other Septic Tank(s) Purr}� out Needed Yes �� No The city recommends the septic tank(s) and/or lift tank be serviced and pumped out every three j (3) years. City records indicate the tank(s)were last pumped out on �r 3D-c� ' The tank(s) should be cleaned through the manhole and not through the inspection pipes, this allows for proper cleaning. Comments: ����.,�-.�-' �����"'-.� Inspector: Date of Inspection: � �4� Telephone (952) 249-4600 • Fax (952) 249-4616 www.ci.orono.mn.us ,� °� . /r� � �, � `�:== - - 'i� C ITY of ORONO � ,��,,��� ��,r.- �, ,� 1 'a � r�ti ;, � ' �,/� Municipal Offices ,'�+' ` '�,%i `�, '� �i'�fw �'ti�� ,,^� � i �,,\\,t9� � �, ; ���` �/ Street Address: �153.-a4q'y6o � Mailing Address: '¢'� 2750 Kelle Parkwa P.O. Box 66 \ ..�\�f'ES�;;%' Y Y -_ Orono, MN 55356 Crystai Bay, MN 55323-0066 To Current Owner: Address: �� ��' �C' 1�G�.� � 1��. City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): � 1 "CODE SYSTEM"An LSTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYS"I`EM" An LSTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot sepazation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an in.rr,;r,ent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may or may not meet all the location,design,o�constr uction standards of tl�e current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): � Tank inspection indicates: 5 Pumpout not needed at this time. 6 Septic tanks must be pumped out thisyear (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped � (';r';v� ). Make sure septic tanks are pumped throuEh manhole and not through white inspection pipes. This allows for the proper cleanine. Keep water softner and iron filter discharge out of septic svstem to prolon¢life of drainfieid. Ask pumper to test alarm float to verifv alarm is still working in vour house. The alarm warns owner that septage is about to backup into basement. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION(8-10): � 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. COMMENTS: � -� ��� `I ��', ( ,c L,( :�_ Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requiremenu for a mortgage or other transfer of property, be advised that this report does not euarantee or certifv that an existinQ svstem will continue to function properly, but is merely an opinion of the adequacy of the system under current .�, o.�,. o . o �i`� =�� ► C ITY of ORONO � , ,� � ���t :� �� -�� � '�, ���,�;�4;''��� ,��► Nt�;��� otr�� '�� i'�`���� / Street Address: Mailing Address: `� �:�'���"� �� G �,, ;�;i . � 9kE+gg04' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: 't Sv ae�i fql� pr, City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMIT'Y (1-3): a 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. � "COMPLIANT SYST'EM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 �NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): 5 Tank inspection indicates: QPumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped `I-�'L� ). Make sure septic tanks are pumped through manhole and not throuQh white insnection aipes This allows for the proper cteanin�. Keep water softner and iron filter discharge out of septic s s�. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION 8-10 : � Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. COMMENTS: �t�.��:e\� � oc1�5 p1�_ Q��-� ScP�-` �,�ks e��� �� �r'—/ � \' e�'�� ) j �—�� ��� v+�� Date of Inspection Matt Bolterman - Septic System Inspector Note: [n the event that this inspection report is used to satisfy the requiremenu for a mortgage or other transfer of properry,be advised that this report does not guarantee or certify thai an existing system will co�tinue to function properly,but is merely an opinion of the adequacy ofthe system under current conditions ba5ed on the available infortnation. Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us .�, o�,. O,:� O �=� "�� CITY of ORONO . a r3 � �'�j � �+ ,� 1�����`��:� �' Municipal Offices � G�'' �, � ��' h t �}''�`���4,� Mailing Address: � �-�,;�� ,k Street Addreu: �Eg�I� 2150 Keiley Paricway P.O. Box 66 Orono, MN 55356 Crystai Bay, MN 55323-0066 Owner: �O�J2(''� �,e5fic.r�e.\(� Address: y so ��,h orq1, �(`, City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFOR�tiIITY (1-3): � 1 ��CODE SYST'EM�� An ISTS which meets all the locaiior�design and construction standards oFthe current Orono hlunicipal Code. QCOMPLIANT SYSTENI�� An ISTS which dors not meet all the location,design and construccion standards ofthe cvarnt Orono Municipal " Coda but does meet the three foot sepuation requiremerrt,and which is not failing or an irtuninerrt threat to public hea(th or safety. 3 ��NON-COMPLIANT SYS1'EM" A prohibited ISTS;an ISTS located within a desigiated 100-year flood plain,any ISTS which may or may not meet all the localioq design,or coastruction stzndards ofthz current Orono�funicipal Code and which is failing for any reuon;and any ISTS with less than three feet of unsaturated soil or sand bztween thz distribution dzvice and the limiting soil charaderistics. TA1�iK CONDITION(�-10): 5 Tank inspection indicates: � Pumpout not needzd at this lime. 6 Tank must be pumped out this yzar (eity codz requires tanlcs to be pumped out zvery 3 years. Tarilc was last pumpzd��`3_� 1 �, 7 Solids accumulation in tanks is at a criQcal a ctitical level. Tanks should be pumpzd out as soon as possible. g S}•stem is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Insprction risers(4"dia.pipe)must be installzd in each tank at next pumpout Iftanks hacz not bten pumped out within the(ast three years,they should be pumped out now. 1� Inspection pipe is located directly over tank baffle(does not gce accurate measurement of so(ids accumulalion). If tanks have not been pumped out within the last three yeazs,they should be pumped out now. DRAINFIELD CO�TDITION(11-1-�)c \\ 1 1 Draintield'u dry,no surfuing evident. 1� Soma evidence of surfacing,not critica!yet 13 Drainfield is saturattd and visibly discharging untreated effiuznt to the surface. Corrtact the City Inspector immediately.Repairs must bz completed within 90 days. - 1=� Drainfield estrnt and condilion unknown. COi�fi�NTS:__ �c��c}��5 hqv� a �ce� OF SePer�t�o� �C?.�„ee� �^-q-te� }-a51 o.�.� bottoM oF fi�e���.cS_ ��� � ��� yeGr .r-►,at- yo�r Sys�-e,� �5 pv�- �c� �(p v d 0 c�o{- nQ Q d �'� n�c tT ��f c e ti�r 3 �vo,- sepe��,t- o^ �^3— o � ��C ��'�e,��..�..,, . Date of Inspection Septic System Inspector � Note: In the evrnt that this inspection tepoR is tued to satisfy the requireme�s for a moRgage or other transfer of propecty,be advised that this report does not guarantae or certify tha2 an axisting systecn will continue to function proprrly,but is merely an opinion of the adequacy of the system under currrnt condilions based on the avaifablz informatioa CITY OF ORONO � O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT r�, � INSPECTION REPORT 'C�� G~ 9kESH��'� Owner: ��'�� etJ IL�S�l C:/�Tt°[G Address: �S� ��r��i¢}I ,�RiUt �Sh�J� Permit �'s: �Jr�� Dates: /�—�-- �� Contractors: /V 6�� City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site seuage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is�an existing system [ ] new construction) SYSTEM CONFORMITY 1-3 : � 1 "CODE SYSTEM"-A system uhich meets all the tocation, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and uhich is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface uaters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located uithin a designated 100-year floodplain; any system uhich may or may not meet all the location, design, and construction standards of the current City Codes and uhich is failing for any reason; and any system uith less than 3 feet of unsaturated soil or sand between the distribution cJevice and the limiting soil characteristics. (The limiting soil characteristici'f�(1 has or [ ] has not been identified at this time. !f the limiting soil characteristic has not been identiyi�rY this classification may be subject to revision.) TANK CONDITION (5-10): � inspection indicates: Pumpout not needed at this time. Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumutation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be punped out uithin 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been punped out within the last three years, they should be p�mped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumpetl out uithin the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): field inspection indicates: 1 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City [nspector irtmediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. L1MITING SITE FACTORS (slope,setbacks,etc.): � POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): --- �J '— COMMENTS: Date o Inspection S tic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the prE�nises with the system loc=tien and pumping records. WHITE COPY/lnspectors File YELLOW COPY/Homeowner CITY OF ORONO � O� Municipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT r�,� � INSPECTION REPORT ti ��9kESH04`'�G > � Owner: j� Address: s a '- I 1�=�� Permit �'s: � Dates: Contractors: City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is � an existing system [ ] neu construction) SYSTEM CONFORMITY 1-3 : 1 "CODE SYSTEM"-A system which meets alL the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Cudes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic�j has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identi ied, this classification may be subject to revision.) TANK CONDITION (5-10): Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be p�xr�ped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface dischar�e. 9 [nspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next p�xnpout. If tanks have not been p�xnped out within the last three years, they should be purtiped out now. � Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out uithin the la��_���s, ey shou d pumped out ow �? J � 4.�C �� DRAINFIELD CONDITION (11-14): Dr field inspection indicates: (�1 Drainfield is dry, no surfacing evident. '12 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated efftuent to the surface. Contact the City [nspector irtmediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS Cslope,setbacks,etc.): Q� POTENTIAL FOR SYSTEM FAILURE (depends on soils,uater table,etc.): ��� COMMENTS: Date of Inspection Se ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system uill continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the prFmises with the system loc�tion and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO � O� Municipal Offices O � O Post Office Box 66 Crystal eay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT r�,� � INSPECTION REPORT '�� G~ �kESH�4'� Owner: �f�S��—Y�iV�f. ��(�(5i'-�� Address: `��'.,X� ,//(a��� ( )j; � Permit #'s: C3 Dates: ��'"��� Contractors: ���V�1� �.. City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked belou. (This is [-�Sl an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface uaters. 2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic � has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK COND[TION (5-10): Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a criticat level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out uithin 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 1 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they shoutd be pumped out now. DRAINFIELD CONDITION (11-14): D Ynfield inspection indicates: �1}! Drainfield is dry, no surfacing evident. 'T2 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed uithin 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENT[AL FOR SYSTEM FAILURE (depends on soils,water table,etc.): 1�� r COMM NTS: �; � — �� /,' � l Da-te of Inspection ptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the pre�nises with the system location and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner On tl�e North Shore o f Lake Nlinnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 1335 S. Brown Rd. � � � Crystat Bay, MN 55323 473-7357 OWNER /��� �t��trTF'10( ADDRESS ��� . PERMIT NO.'S. �'� DATES /r s $' CONTRACTORS City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The o�-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is f� an existing system ❑ new construction) �� Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. � 2 Does not meet all current City standards for new construction (1978 Code1 but in most respects appears to be designed, located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major upgrading of the system is required at this time. � 3 Does not meet current City standards in many respects relating to design, construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtai�a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not �Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump• have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. �Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Orainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4"dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table and system condition) �Adequate ❑ High water table �Low ❑ Fair ❑ Lot size ❑ Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High � Inadequate ❑ Drainage ❑ System is causing visible surface discharge. COMMENTS: 7/Q�4./ Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner On the North Shore o f Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 � _ � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER ��U.�� /�IP.�STc��L�1 ADDRESS ���✓ �L�-'��lN I�Y PERMIT NO.'S. �S� DATES ���L�J CONTRACTORS J� 7 City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is '� an existing system ❑ new construction) �( � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating �V properly. � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes. System appears to be functioning properly;no major upgrading of the system is required at this time. � 3 Does not meet current City standards in many respects relating to design,construction, or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard, or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump• have not been pumped out within the last three years,they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical Ievel, Tanks Drainfield inspection indicates: should be pumped out as soon as possible. � Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated � �Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe) must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they shoul pumpe ou now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) �Adequate ❑ High water table � Low ❑ Fair ❑ Lot size ❑ Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High . ❑ Inadequate ❑ Drainage ❑ System is causing visible surface isc arge. �n � / ` i / � / COMMENTS: �-�/�j —� � � P.7I ► � � � Y�P � � /' J ���D � Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other tra�sfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner