Loading...
HomeMy WebLinkAboutseptic info SEPTIC SYSTEM INVENTORY Addr: 940 Dakota Ave . PID: 26-118-23 33 0016 Building Type : residence # BRs/GPD: 3 # Systems/units : 1/1 Permit No : 2202 Date of Permit : 8/1/69 Installer : E . J. Peterson System Type : standard trench Appliances : lndry SYSTEM CONDITION Conformity: 3 Tank Condition: 10 DF condition: 11 Failure Pot : medium SEPTIC TANKS Material : concrete block Capacity: 750 , 550 Setback to Bldg: 15 DRAINFIELD Length of Lines : 200 No . Lines : Trench Width: 2 Treatment Area : 400 Type of Filter: rock Tile Size : Under Tile : Perc Rate mn/in: Setback DF-Bldg: 20 DF Ht above WT : 0 . 3 Soil Type : Limitations : water table WELL DATA Setbacks - Well-Tanks : 50 Well-DF : 50 Report in File? : y Pump Type : subm. Depth: 93 Diameter: 4 Method: drilled INSPECTION RECORD PUMPOUT RECORD Date Compliance Date Gallons 6/29/81 no surfacing 2 7/7/78 1000 7/25/85 no srufacing 2 7/1/86 1500 6/27/86 no surfacing 2 8/1/88 1500 6/18/90 no surfacing 2 8/1/92 1500 8/27/92 DF discharging to low area 3 3/1/93 1500 9/16/92 drain tile to low area removed 2 9/10/93 1500 9/21/94 non-conforming-repair by 12/31/96 3 � � � V � / � � C �3'� ' �'� ��a �,/�. �e� I �I �' J-- ��' I� '� �h � T , _ ��� �D ;; T r� - v� ��\ -� - - _ � 1 . � � � � 1 '� ^ �T`le �;,�,�.�o�� rerrr�v�� _ _ _ �_lb.�►a � , ` i i i � � r �� � I i � � � �� � � I � I � � �. CITY OF ORONO � O� Municipal Offices O � O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT r�,� � INSPECTION REPORT '�' Gti �9kESH�g'� Owner: 1�1�]L#Cy1 ,7�I�1�'�, Address: /`7� �K4'�c�l l7V�, Permit #'s: ��� Dates: ��'—�� Contractors: �t 11 �"�7"�✓�\ l� City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is DEJ-an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYS7EM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input uithout discharging any pollutants into ground or surface uaters. 2 "CONFORM[NG SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but uas installed according to the code in effect at the time of installation, and ahich is operating satisfactorily by treating and disposing of the entire current sewage input without discharging � any pollutants into ground or surface Waters. "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and an s stem with less than 3 feet o between the distribution device and the limitin9 soi c arac er . �',r L 1���pj \ I ' 171� ) /b �,J� (The limiting soil characteristic � has or [ ] has not been identified at thi time. Yf the limiting soil J� characteristic has not been identi ied, this classification may be subject to revision.) TANK CONDITION (5-10): � Tank inspection indicates: 5 Purtipout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accurtiulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. 7anks must be pumped out uithin 48 hours to eliminate surface dischar�e. 9 ]nspection risers missing-tanks could not be inspected. lnspection risers (4" dia. pipe) must be installed in each tank at next purtipout. If tanks have not been pumped out within the last three years, they should be pumped out now. inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out uithin the last three years, they should be pumped out nou. DRAINFIELD CONDITION (11-14): Dr�nfield inspection indicates: Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City I�spector irtmediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): ��� POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table,etc.): ���1,��-_ �OMMENTS: � �," _ � p C� � � Q, � 'S � � A'� s Date of nspection Septic ystem Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available informatton. This report must be kept on the prEmises with the system Loc�ti�n and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO � O� Municipal Offices O � O Post Office Box 66 Crystal Bay, MN 55323-0066 a � ON—SITE SEWAGE TREATMENT r�)� �, INSPECTION REPORT ti ��9kESH0�'�G /� Owner: ��✓1C31� Y;°;1�_ Address: L� .Ll��i�7,.d j�1/(� , Permit #'s: ��� Dates: �—�—�7 Contractors: �Ji �t���✓�?�!', l <�, City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is � an existing system [ 7 new construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system uhich meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and uhich is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ ] has or pQ.,has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): C' �.a_ T inspection indicates: 5 Pumpout not needed at this time. Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. lf tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pixnped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): � Drainfield inspection indicates: 11 Drainfield is dry, no surfacing evident. 1�,, Some evidence of surfacing, not critical yet. � Drainfield is satu eated effluent to the surface. Contact the City Inspector i�mned��i�a�tely. DPo ir must be com leted within 9 a 14 Drainfte" l e�t and condttton uncnown. � LIMITING SITE FACTORS (slope,setbacks.etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): ��j COMMENTS: ✓^� �--,_ Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available tnformation. This report must be kept on the pre�nises with the system loc>_ti�n and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner