Loading...
HomeMy WebLinkAboutseptic info SEPTIC SYSTEM INVENTORY Addr: 908 Dakota Ave . PID: 26-118-23 33 0022 Building Type : residence # BRs/GPD : 3 # Systems/units : 1/1 Permit No : 4415 Date of Permit : 5/20/76 Installer : Widmer Bros . System Type : standard trench Appliances : lndry SYSTEM CONDITION Conformity: 3 Tank Condition: 5 DF condition: 13 Failure Pot : surfacing SEPTIC TANKS Material : concrete Capacity: 1000 , 1000 Setback to Bldg: 35 DRAINFIELD Length of Lines : 250 No. Lines : 3 Trench Width: 3 Treatment Area : 750 Type of Filter: rock Tile Size : 4 Under Tile : 6 Perc Rate mn/in: 10 Setback DF-Bldg: 30 DF Ht above WT: 0 . 3 Soil Type : sand, sandy loam Limitations : water table WELL DATA Setbacks - Well-Tanks : 75 Well-DF: 75 Report in File? : y Pump Type : subm. Depth: 116 Diameter: 4 Method: drilled INSPECTION RECORD PUMPOUT RECORD Date Compliance Date Gallons 5/24/76 installation 4/5/82 2000 6/29/81 no surfacing 1 2/11/87 800 11/29/84 no surfacing 1 8/1/90 1000 9/28/87 no surfacing 1 11/26/93 800 6/18/90 no surfacing 1 10/19/94 1000 7/31/92 no surfacing-new grass on DF 1 1/11/95 1000 9/19/94 DF surfacing-non-conforming 3 11/29/95 1000 2/5/96 1000 S � �� �'���.�i l � � �Q� �c� �a��. ,�'��,� IV (�e� � .D � ��� � G , 6� �g� � �r� ��� � - � � �� �� � � � � e � l 3� '� I�� CITY OF ORONO � O� Municipal Offices O O Post Office eox 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT r�,, � INSPECTION REPORT �� G~ 9kESH��'� Owner: , �'(J� N,��L�� Address:��� 2� �Q �(�l � s Permit �'s: /� Dates: ��'�yl, Contractors: l����T /���, � City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is �an existing system [ ] neu construction) SYSTEM CONFORMITY (1-3): 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONfORM[NG SYSTEM'�-A system uhich does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located uithin a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and an sv m � ��;,s than 3 feet of �n�aturated soil �� �� � betueen the distribution deviee and rhP Limiting soi c aracteristics (The limiting soil characteristic q�has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK COkD1T[ON 5-10 : Tank in ect q indicates: 5 �P�po, f ot neederJ at this time. ,b� `SQ�`1Bi's accumulation in tanks indicates they should be pixnped out this year to help prevent future problems. « Sri�'Q§ accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out uithin 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next purtipout. lf tanks have not been pumped out uithin the last three years, they should be purt�ped out noa. 10 ]nspection pipe is located directly over tank baffle (does not give accurate measurement of solids acc�miulation). If tanks have not been purtiped out within the last three years, they should be purnped out noW. DRAINFIELD COND[TION (11-14): Drainfield inspection indicates: 11 Drainfield is dry, no surfacing evident. 1,21 Some evidence of surfacing, not critical yet. ��� Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact t irtmediately. R�airs must be completed within 90 days. 14 DrainfTe e�ana c3naiiion unKnown. LIMITING SITE FACTORS (slope,setbacks.etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table,etc.): COMMENTS: � ,(JJ � Y � � s a - , ��e v►,,,` Date o Inspection Septi System Inspector " Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system Will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available tnformatton. This report rteust be kept on the prE�nises with the system loc�tien and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO � O� Municipal Offices O � O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT � � INSPECTION REPORT ti ��9kESH0�'�G Owner: �l3� (�/1/.��1'� Address: ��� [�/�!� j���� Permit #'s: �{�/� Dates: �S��� Contractors:,f�,�G�/?'�Y ��,�- City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is � an existing system [ ] new construction) SYSTEM CONFORMITY 1-3 : 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input uithout discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic [ 7 has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): Tank inspection indicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffte (does not give accurate measurement of solids accumulation). If tanks have not been purtiped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): Dr,ar�field inspection indicates: �C1 Y Drainfield is dry, no surfacing evident. �rz Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): COMMENTS: r p�j` �` ` � � �' � � Date of Inspection eptic ystem Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the prE�nises with the system loc�tien and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner