Loading...
HomeMy WebLinkAboutseptic info * _ -.., .¢, O,� � O ,, O CI'T'Y OF ORONO �'`9 _ s Municipal Offices a �� . � �, �,, ,� � �, Street Address Mailing Address: �L G�' 2750 Kelley Parkway P.O. Box 66 �i Orono,MN 55356 Crystal Bay, MN 55323-0066 9kESH04 To: The Current Owner of Address 185 CRYSTAL CREEK RD City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health -hreat Yes /1 No If yes, please contact the Onsite Systems Manager at 954-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as No -Compliant Yes No If yes, system must be brought into compliance by: Deceinber 31, 2007 December 31, 2010 Other Septic Tank(s) Pum ut Needed Yes No The city recommends the septic tank(s) and/or lift tank be serviced and pumped out every three (3) years. City records indicate the tank(s)were last pumped out on �-�� The tank(s) should be cleaned through the manhole and not through the inspection pipes, this allows for proper cleaning. Comments: � Inspector: '"��4JC.C.JK., ��4� Date of Inspection: �� � Telephone �952) 249-4600 • Fax (952) 249-4616 www.ci.orono.mn.us � � � • � To: Orono residents on mound type septic systems From: Wiliie Gibbs, ISTS Manager Date: May 10, 2006 Re: Landscaping Do's and Don'ts for Mound Systems, Quick Reminder Do plant and maintain a full cover of grass and keep mowed to a normal height, this grass cover aids in the evaporation of large amounts of effluent (the liquid left after the "other" stuff has been removed) in the summer time and allows the mound system to help breakdown nitrogen in the effluent, Do water the grass over the mound in extreme dry conditions, sparingly. Do avoid unnecessary foot traffic over the mound, mow it and stay oif of it. This is especially true in the winter time. Even human foot traffic can cause frost to penetrate the mound resuiting in potential freezing prablems. Do inspect your mound system annually for winter kill, (reseed if necessary) animal damage, (burrowing)or signs of potential faifure. Do not plant trees or shrubs on the mound system, smaller trees and shrubs may be planted at the edges. Remember, that sunshine is the key to a healthy mound system. Do ask questions, if you have any concerns or questions concerning your mound system please feel free to call me, E can be reached at 952-249-4626. 1 ;; � ° � � o : o =�����}- - CI'�I' �rf �ROl�TO , r� �r'�`;',�'.�``;'a;,._., � ,aiy i, � \'�'+, b� a : i i..:... �/ Municipal Offices �"� '��'� �s�"��"� G � Street Address: `�5a'a4 q"�6� � Mailing Address: , �,;J�r .`�,. .r � ` ����kE$HO¢�'/ 2750 Kelley Parkway P.O. Boz 66 ��--��" Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: / ��5 �`�.� �`� � ��C��I� City Ordinance 199 requires that each existing on-site sewa�e treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the cate�ories checked below. SYSTE�M CON�'ORIv1ITY (1-31: � 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. Z "CO1bTPLLAIVT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Nlunicipal Code but does meet the three foot sepazation requ¢ement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threa[to public health or safety. 3 "NON-COLIPLIA2�iT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may or may not meet all the loeation,design,or constrvction stand�irds of fl�e current Orono Municipal Code and which is failing for any reason;and any ISTS�vith less than three feet of unsaturated soil or sand between the distribtrtion device and the 1'uniting soil characteristics. TA1vrFC CONDITION(5-7): � Tank inspection indicates: � Pumpout not needed at this time. 6 Septic tanl:s must be pumped o�µt t�s year (city code recorrunends tanks to be pumped out once every 3 years. Tanl:was last pumped �� )• 1bl�l:e sure septic tanks are pumped throuah manhole and not throu�h white inspection pipes. T'his allows for the proper cleanina Keep water softner and iron filter dischar�e out of septic svstem to prolono life of drainfield. Ask pumper to test alarm flo�t to verifv alarm is still workinQ in your house. The alarm warns owner that septaQe is about to backup into basement. 7 Inspection risers missinQ-tanks cotild not be inspected. Inspection risers (4"dia.pipe)must be installed in each taril:. If tanl:s have not been pumped out within the]ast three years,they should be pumped out no�v. � DRAINFIELD CONDITIOri(8-101: � 3 Drainfield is dry,no surfacin�evident. � 9 Some evidence of surfacinQ, not critical yet. � 10 Drainfield is saturated and visibl_y dischar�ing untreated e�fluent to the surface. Contact the City Tnspector j immediately. Repa:rs mtut bz completed within 90 days. � i ' ; ����,,T��-i�. ��� ��,,a �% y� :�/fi 3� L, " '..., '�! _ �y� �, � t `�' � ��� �=�vp ..��� J Tl...� ..,^-T..._...�::..� Can.t,^ \�;..h_�r-i Tncn?rtnr � o� o=_���:� o � �:��,,��`� ,, CITY of ORONO \� ���� ���.,,.'!� '��'/I Municipal Offices �.t �'��;��;����`��.�G/ Street Address: Mailing Address: 9kEgHo4' 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 • --- _ —. To Current Owner: Address: � �S C�y�.?.�� Cf c ej� R� City Ordinance 199 requires that each existing on-site sewage h-eatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYST'EM CONFORMITY 1-3 : � 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" M ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or eazlier,and which is not failing or an imminent threat to public health or safery. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year tlood plain,any ISTS which may or may not meet all the location,desipn,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any[STS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil chazacteristics. TANK CONDITION(5-7): E� Tank inspection indicates: 5 Pumpout not needed at this time. 6OSeptic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped �✓c�kno w� ). Make sure septic tanks are pumped throu�h manhole and not through white inspection aipes This allows for the proeer cleaninQ. Keep water softner and iron filter discharee out of sentic svstem. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION(5-10): � � Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. COMMENTS: r�u�✓� �v e`<S 0�-, �'u�-- S�� �:L -}�,r.�CS n 2�c'�- S ,r . �F X�c l�av c, c.o�r ��c.� �,��- c w-�-�... ���S i- 'S cc f S _ �I e�^ �=\4'< < 0 � S�tc� ��IC. O�CL P�r \��q!' , I —7 —\5'—0� �c.�.-� Date of Inspection Matt Bolterman - Septic System Inspector Note: (n the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion ofthe adequacy of the system under current conditions based on the available information. Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us J,�. O ~ CITY of ORONO �x�:,��� � �"���� � ��� 5 �� �=� �a�,, ,�,�' Municipal Offices � �1�;��`�' G Street Add�ess: Mallin Address: ���� 4,'� L �'EggO 2150 Kelley Parlcway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 : Ke �� ����k M�,\('dS2 Address:_ I �S C-r�sfiq I CreeK Rd Jrdinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. ,on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMIT'Y 1-3 : � 1 ��CODE SYSTEM�� An ISTS which meets all the localion,desigi and construction standards ofthe currerit Orono Municipal Code. 2 COMPLIANT SYSTEM�� An ISTS which does not meet all the location,design and construction standards ofthe cuaent prono Municipal " Code but does meet the three foot sepazation cequuement,and which is not failing or an imminent threat to public health or safety. 3 NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may ' or may not meet all the location,design,or construction standards ofthe cucrecrt Orono Municipal Code and which is failing for any reason;and any ISTS with►ess than three feet of unsaturated soil or sand between the distribulion device and the limiting soil characteristics. TANK CONDITION(5-10): �_ Tank inspection indicates: SO Pumpout not needed at this time. 6 Tank must be pumped out Uus yeaz (city code requires tanks to be pumped out every 3 yeacs. Tank was last pumped ), 7 So(ids accumulation in tanks is at a critical a critical level. Taziks shou(d be pumped out as soon as possible. 8 System is dischuging to the surface. Tanks must be pumped out within 48 houcs to eliminate surface discharge. 9 Inspedion rise�missing-tanks could not be uupected. Inspection rise�(4"dia.pipe)must be ins�talled in each tank at next pumpout If tanks have not been pumped out within the last three yeazs,they should be pumped out now. 1� Inspection pipe is located directly over tank ba&le(does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three yea�,they should be pumped out now. DRAINFIELD CONDITION(11-141: _�\ 11 Drainfield is dry,no sucfacing evident. 12 Some evidence of surfacing,not critical yeL 13 Drainfield is saturated and visibly dischazging utrtreated effluent to the surface. Contact the City Inspector irnmediately.Repairs must be completed wiUun 90 days. 14 Drainfield extent and condition unknown. co�rrTs:_ sysfie� -�5 ok P�Mp -�a�Ks ;� �ooa o3 Yov hav �.I �s o� q�ks fi►.qfi r�.� t b� e � J 'cql � bC rnci;^fiG;n r� • 6-a�- o � /�"/�/��//��Q y,A} �/� _ - 1 ""\ III/!I V '�+ [��M Date of Inspection Septic System Inspector � Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this repoR does not guarantee or ceRify that an existing System wili continue to function property,but is merely an opinion of the adequacy of the system under cuirerrt conditions based on the availabie infocmalion.