Loading...
HomeMy WebLinkAboutseptic info �Z CITY OF ORONO Date ADDRESS � Connected to �� ( CODE SErTIC SYSTEM INVENTORY CARD Munici'al Sewer � Address � /� �DfE ST V��� Property I.D. �S—I/�7 �Z3 /� �/� WELL DATA �Standard trench h. .� I I ❑ Mound LoT 7j{� �l.iCk� C., � System type O Other Legal Description B.�`�S/pE�D�/r/D/� , � p I � L Permit No. � Date of permit Installer "' � p d No. Bedrooms Garbage ,� „ ( Building type �SlDE/UL�c or GPD Z $� Laundry X Dishwasher�VJ DisposallL�v ` " = _° `oQ Q / � E SEPTIC TANKS: Material l�Ci�:� 15�vC-fc Capacity 1) � 2) ✓ ° � •o n�r'_ °' � Proper outlet and inlet Baffles Liquid depth to RO level � � 7 °' O i � /� Y Height of tank bottom above water table Distance to nearest building `� � .'n N m v p DRAINFIELD: Total length of lines Number of lines � ? Trench width Y � C Total treatment area(sq.ft.) Height f dr ' fi above water table ;? �- U Type of filter material S il ty e � � � t = Distance from nearest bldg. ile iz Perc rate min/in o � � c � �, o v U N Depth of fill over drainfield epth of rock over tile under tile � n .� " `0 E c — p a cj � LOCATION INSPECTION RECORD PUMPOUT RECORD SKETCH �/�� iy DATE COMPLIANCE DATE GALLONS g'��-7� illd Su�erAG�u� Nor�� S �T4z.7 �fJ / 7-3D r£�D NO S�•R F�4 C/�V fr _ �. � - - -� � � � _ , �-`t- Sl`( .a:u s,,�,�F A�i N G ' � ' a /2-;"3 �(� a�ofL� wC�Llr LoC�(ovJ ' �$ � /� � h�� � -l- � ✓?� .�l/Y-i�C'i✓k1 -n�z✓S � � �6 � ��-9> >� �� -, " �, �, _ �AR� ` ,,N ,�� � C.i2ES`Vt C'� Include: 1) Well location 2) Distance from house to septic tanks,dist.box, and drainfield C— CONFORMING S—SUBSTANDARD N —NONCONFORMING 3) North arrowand road 2N� •fANK LfNt7t'"72 C/IA�K�`D Q:NYJL �/J �'�TO.IA! V j'" � � �� ��"� � � � � � ��� . -:�t�,. �� CITY of ORONO ';� ,' ^"% . ti ' Municipal Offices l.. �/ � '� °,�; �� ` G% Street Address: `�:;-�,9 � ��;¢�i,� Mailing Address: ��-�fEggO :;=� 2750 Keiley Parkway P.O. Box 66 _ � Orono, MN 55356 Crystal Bay, MN 55323-0066 NOTICE OF ZONING VIOLATION Date: April 14, 2003 Property Owner: PATTY L CLAPP Location of Violation: 290 CRESNIEW AVE LONG LAKE MN 55356 Conditions exist on the indicated property which constitute a violation of the following section(s) of the Orono Zoning Ordinance: X SECTION 9.50. JUNKCARS, FURNITURE, HOUSEHOLD FURNISHINGSAND APPLIANCES STORED ON PUBLIC OR PRIVATE PROPERTY. It is unlawful to park or store any unlicenced,unregistered or inoperable motor vehicle lacking essential parts, household furnishings or appliances,or parts or components thereof,on any property,public or private,unless housed within a lawfully erected building. Any violation ofthis Section is declared to be a nuisance and upon seven days written notice to the owner,as shown by the records in the office of the County Auditor,of private premises on which such material is found,the Ciry may remove the same and certify the cost of such removal as any other special assessment. For the purpose of this Section,an inoperable motor vehicle shall be defined as lacking,includin�but not limited to,parts essential to operation,such parts being wheels,tires,motor,drive train,battery,or having two or more flat tires,or having the interior, including the driver's position,used for storage in such a manner that no person can operate the vehicle. (Car in back yard) X SECTION 9.5�. MAINTENANCE OF PRIVATE PROPERTY. SUBD. l. It is the duty of the owner of every vacant property and the owner and occupant of every occupied property to maintain same in a neat;clean and presentable manner free of any junk,debris,refuse,litter,dead trees, or noxious weeds, and to remove all other public health or safety hazards therefrom. (Junk in yard) SUBD. 2. GrasS and Weeds. The owner or occupant of every lot or parcel shall regularly cut or otherwise maintain all grass and weeds thereon at a heiaht of not more than six(6) inches. SUBD.3. Any violation of this section is declared to be a nuisance and public safety and welfare hazard and upon seven days written notice to the owner, as shown by the records of the office of the County Auditor, of private premises on which such material is found or any conditions in violation of this code section exist, the City may remove the same or correct any conditions in violation, and certify the cost of such removals or corrections as any other special assessment. Please take action to comply with the above ordinance requirement(s) by April 28, 2003 A follow-up inspection will be made at that time to verify compliance. If you have any questions regarding this matter, please call me at (952) 249-4600. "��\�� 'd'D �". =n{sp�ct or- Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us On the North Shore of Lake Mi�rnetorzka ON-StTE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 1335 S. Brown Rd. � � � Crystal Bay, MN 55323 473-7357 OWNER ADDRESS �C ,��l7LjC� rl�'�� PERMIT NO.'S. ��� DATES ` CONTRACTORS � City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is �,an existing system ❑ new construction) � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. �2 Does not meet all current City standards for new construction (1978 Code► but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly; no major upgrading of the system is required at this time. � 3 Does not meet current City standards in many respecis relating to design, construction, or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Please contact the City I�spector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit betore work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. �Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated � Ins�ection risers missing—tanks Cn��ld �_� in p�t d� effluent to the surface. This condition may require replace- I must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not en pumpe out v�nt in immediately.Repairs must be completed within 90 days. LTie ast ree y rs, y s ou pumped out now. - ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) O Adequate ❑ High water table ❑ Low C] Fair ❑ Lot size �-Medium �Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑ System is causing visible surf c dis harge. COMMENTS: / � � `�/� .����1 Date of Inspection S ptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY!Inspector's File GOLD COPY/Homeowner On the North Shore of Lake A�Iinnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 s . � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER � / ADDRESS ��t� %,-YA� IC�� ,�{��� PERMIT NO.'S. � DATES CONTRACTORS — City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is (� an existing system ❑ new construction) � � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major upgrading of the system is required at this time. �3 Does not meet current City standards in many respects relating to design, co�struction, or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.Ptease contact the City Inspector to discuss system repair/ replacement procedures. If drainfietd replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Ta�k inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years,they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. ,� Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfiefd is saturated and visibly discharging untreated -� � Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) ❑ Adequate ❑ High water table Low ❑ Fair ❑ Lot size '�.Medium �Poor ❑ Lake,wetland,or stream ❑ High . ❑ Inadequate ❑ Drainage ❑ System is causing visible surface discharge. COMMENTS: � .��S���lY\ ��SP✓S /'Y)I/,Sf �� �Y15�����/ /✓i��%�� I� .��'�; </l�1� � f ,' � � �� �-�"C� , Date of Inspection eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opi�ion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner On the North Shore o f Lake Minnetonka ON-SITE SEWAGE TREATMENT INSPECTION REPORT POST OFFICE BOX 66 � 1335 S. Brown Rd. Crystal Bay, MN 55323 � � � 473-7357 OWNER QENE�1�'T� ��t�(�l� ADDRESS � 1� C.R�Si�1SC� a�1L1�1r3C PHONE PERMIT NO'S. — DATES —' City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below: ❑ � Meets or exceeds current city standards in all respects relating to design, construction, and location. Appears to be operating properly. Does not meet current city standards in some respects relating to design, construction, or location. Appears � � to be operating properly. ❑ � Does not meet current city standards in many respects relating to design, construction, or location. Appears to be operating adequately. ❑ � Does not meet current city standards of design, construction or location, is being overused, or is failing to properly treat and dispose of the current input and is therefore endangering a water supply, is a source of pollution to surface or groundwaters, is creating a safety hazard,or is otherwise creating a public nuisance. Please contact the inspector to discuss requirements for repairs to your system. Soil testing may be re- quired. In all cases a design and site plan must be submitted for review. Your contractor must obtain a permit before work is started. WORK REQUIRED: � Septic tanks must be pumped within 48 hours. � Drainfield must be repaired or replaced within 90 days. �� Inspsction riser (4"diam. pipe) must be installed in each tank. /�T NEX�T PvM PdNG � Tank inspection indicates maintenance pumpout is needed as soon as possible. City ordinance requires that tanks be pumped out every three years. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑Slope (depends on soil types,water Future Expansion �Soil table,and system condition) � Adequate ❑High water table ❑ Low � Fair �Lot size �Medium � Poor 'X Lake,wet�and,or ctraam ❑ High ❑ Inadequate �Drainage ❑System is causing visible surface discharge. COMMENTS: 7 - 9 - $'1 �..,Sle �m�x. Date of Inspection Se System Inspector This report must be kept on the premises with system location and pumping records. WHITE COPY/ Inspector's File GOLD COPY /Homeowner