Loading...
HomeMy WebLinkAboutseptic info � o� O ,, O CI'TY OF ORONO �s -,. � �'�� � MunicipalOffices � � Street Address Mailing Address: �� � G 2750 Kelley Parkway P.O. Box 66 �i Orono, MN 55356 Crystal Bay, MN 55323-0066 9kESH0� To: The Current Owner of Address 4650 CREEKWOOD TR City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat � Yes �No If yes, please contact the Onsite Systems Manager at 954-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non-Compliant Yes =�No If yes, system must be brought into compliance by: December 31, 2007 December 31, 2010 Other Septic Tank(s) Pump out Needed Yes �No The city recommends the septic tank(s) and/or lift tank be serviced and pumped out �ry three (3) years. City records indicate the tank(s) were last pumped out on � . I� _ o� The tank(s) should be cleaned through the manhole and not through the inspection pipes, this allows for proper cleaning. Comments: Inspector: Date of Inspection: R `�� ���C"."� ��C�L� Telephone �952) 249-4600 • Fax(952) 249-4616 www.ci.orono.mn.us • • • � � To: Orono residents on mound type septic systems Prom: Willie Gibbs, ISTS Manager Date: May 10, 2006 Re: Landscaping Do's and Don'ts for Mound Systems, Quick Reminder Do plant and maintain a full cover of grass and keep mowed to a normal height, this grass cover aids in the evaporation of large amounts of effluent(the liquid left after the "other" stuff has been removed) in the sumrner time and allows the mound system to help breakdown nitrogen in the effluent, Do water the grass over the mound in extreme dry conditions, sparingly. Do avoid unnecessary foot traffic over the mound, mow it and stay off of it. This is esp�cially true in the winter time. Even human foot traffic can cause frost to penetrate the mound resulting in potential freezing problems. Do inspect your mound system annually for winter kili, (reseed if necessary) anima! damage, (burrowing) or signs of potentiai failure. Do not plant trees or shrubs on the mound system, smaller trees and shrubs may be pianted at the edges. Remember,that sunshine is the key to a healthy mound system. Do ask questions, if you have any concerns or questions concerning your mound system please feel free to call me, I can be reached at 952-249-4626. 1 � �� . . O_�a O `� ��� I C ITY of OR4NU ,�ti.��.,r; - - .� ����? - � ��- - �' / ������ '���.�:-��L �!4 Municipal Offices ��� "�' ���;��<�,Fti C�/ \ ` '�``�� �.C� / Street Address: Mailing Address: ,, � -,���,t�,� 4ry , kEBH�%� 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: �6' U Lf t2�'""�C�� )�'`�, , City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. T'he on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYST'EM CONFORMITY 1-3 : � 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standatds of the curren[Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standazds of the current Orono Municipal Code but does meet the three foot sepazation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any 1STS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): Tank inspection indicates: 5 Pumpout not needed at this time. � 6� Septic tanks must be pumped out this year (city code requues tanks to be purnped out once every 3 years. Tank was last pumped �'S�`�� ), Make sure septic tanks are uumped throush manhole and not throu¢h white insaection piaes. This allows for the proper cleaning. Keep water softner and iron filter discharge out of septic svstem. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. D INFIELD CONDITION(8-10): � Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. COMMENTS: r'`� ���) � u c�s 0�, �c.��.� Se��:� ��kS ,$v�.n�� �l� Q � , l c; -i�-�� �� � Date of Inspection Matt Bolterman- Septic System Inspector Note: In the event that this inspection report is used to sadsfy the requirements for a mortgage or other transfer of properly,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. Telephone(952) 249-4600 • Fax(952)249-4616 www.ci.orono.mn.us / // O\ �� � � i'�� ��`1 � ` ►i C ITY of ORONU �; „ � ��1� �^''� y� r� e � ti l� Municipal Offices ��`r�,'� �� � ,�.�_ �:-`: ��'" � � Street Address: Mailing Address: , �9, ' .¢,�' , ':,,kE$KO ; 2750 Kelley Parkway P.O. Box 66 �==_�� Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: ����C �` Zz��- ''�'�'�`cl �' ���; 1 City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every rivo years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): ( (1 )"CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. �.� 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the cunent Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not fail ing or an imminent threat to public healdl or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an[STS located widiin a designated 100-yeaz flood plain,any ISTS which may or may not meet ail the location,design,or constn�ction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three Feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): � Tank inspection indicates: 5 Pumpout not needed at this time. � Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped ). Make sure septic tanks are pumped through manhole and not throu�h white inspection pipes. This allows for the proper cleanin�. Keep water softner and iron filter discharge out of septic system. 7 Inspection risers missing-tanks could not be inspected. Inspection risers (4"dia.pipe) must be installed in each tank, If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION (8-10): � � Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the Ciry Inspector immediately. Repairs must be completed within 90 days. COMMENTS: �"�c:;�.l, �o c>�S �k,. �u�,�--� S�.�3��.... fi���.l� o��c�, ev�c-� '�3—�-\ v e�,!S _ �—\S —0 � �� !'' y�� Date of Inspection Matt Bolterman - Septic System Inspector Note: In the event that this inspection report is used[o satisfy the requirements for a moRgage or other transfer of property,be advised that this repoR does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion ofthe adequacy of the system undercurrentconditions based on the available information. Telephone(952)249-4600 • Fax(952)249-4616 � O� O �.� O �'3 � � CITY of ORONO .:.�, �.-� � ,� �j���,��. � �, � , ��: �. ri ti � M�� otr�� ,� , ��� Gti ,� ��� � .� Street Address: Malling Addreu: �EgK04' 2750 Kelley Pa�kway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: k2V�n � � o�K Address_ �f6So ��ee.I�woo� '(��`_ City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-31: � Ol °CODE SYST'EM° M ISTS which meets all the location,design and construction standards ofthe aurent Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the locatioq design and consttuction standards of the cucrerrt Orono Municipal Code but does meet the three foot sepazation requirement,and which is not failing or an imminerrt thr�to public heatth or safety. 3 ��NON-COMPLIANT SYSTEM�� A prohibited ISTS;an ISTS located within a dzsignated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono hiunicipal Code and which is fai(ing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution dzvice and the limiting soil chazacteristics. TANK CONDITION(5-10): 6 Tank inspection indicates: $ Pumpout not needed at this time. OTank must be pumped out tlus year (city code requires tariks to be pumped out every 3 yeacs. Tartk was last pumped �"5—� � ) 7 Solids accumulation in tanks is at a critical a crilical level. Tanks should be pumped out az soon as pamble. g System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface disc�arge. 9 Inspec[ion risers missing-tanks could not be inspected Inspection risers(4"dia.pipe)must be installed m each tank at next pumpout Iftanks have not been pumped out within the last three yeats,they shou(d be pumped out now. 1� Inspection pipe is located duectly over tank ba81e(does not give accucate measuremerrt of solids ac��**��>>�*+on). If tanks have not been pumped out within the lut three years,they should be pumped out now. DRAINFIELD CONDITION(11-14): �J_ 11 Drainfield is dry,no surfacing evidrnt 1 Some evidence of surfacing,not critical yet • 13 Drainfield is saturated and visibly discharging ucrtreated effluent to the surface. Contad the City Inspector mmmediately.Repai�must be completed withitt 90 days. 14 Drainfield extent and condition unknown. COMNIENTS:� �FG�kS '� ���v ha,ve r�ot- �Jv�p�d �:-}-I,;.� � qs�-- 3 ye��5_ Svste� ;5 Ok_ 6-as-6� �� � Date of Inspection Septic System Inspector 4 Note: In the event that this inspeckion report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guazantee or ceRify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the s}�under cuirent conditions based on the available info�nation. � o� � „ o � o�, ;��; ,���,,t�.- � � '��� CITY of ORONO ;�� Municipal Offices �' �, �. �����= 'ti�� � �� %�<I, `,��;,`�G� Street Address: Mailing Address: '`9x�Kpg' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: / Address: 4650 Creekwood Tr. Permit #'s: 4 63, 10303 Dates: 7/1/92, 6/2/98 Contractors: Hayes Exc. , Hayes Exc. (This is �] an existing system ( ] new construction) . SYSTEM COMPLIANCE (1-3) : 1 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant System: System may or may not meet current City standards for design, - construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level is [ ] or is not [ ] identified under this septic system. If the saturated soil level is not id ntified, this classification is subject to revision.) NK CONDITION (5-9) : 5 5 Pumpout not needed at this time. Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. 10 One or more tanks are cesspools, which means the septic system is non-compliant. (The tanks are [�j or are not [ ] water tight or the condition is [ ] unknown. If the tanks are not confirmed to be watertight, this classification is subject to revision.) �D INFIELD CONDITION (11-14) : 11 Drainfield is dry, no surfacing evident. .. 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAIL()RE: (system age and condition, soils, etc.) : low COMMENTS: �'�� q9 �� Date of Inspection S c System Insp ctor Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing. system will continue to function properly, but indicates the operation of the system under current conditions. Telephone(612)249-4600 • Fax(612)249-4616 � °� �, �� _ � � - _ � ��, �:�,��.:,r=�;,,._ � CITY of ORON� � ,��, � 4 � � � �`,, ' �` �'I ��� FY � Municipal Offices \\� � /�I!t'�� ���I��k�`\.,pi� ��� ��. \l� „ � 1 { , �g� � Street Address: �15a'a�q'y6o 0 Mailing Address: . `��kE3H� :�' 2750 Kelley Parkway P.O. Box 66 ��—� Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: ��%���' � ��CJ � z.��;,,.�rt i�. City Ordinance 199 requires that each e�isting on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): 1 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIAIV�T SYSTEM" An ISTS which does not meet all the location,design and consnvction standards of the current Orono Municipal Code but does meet the three foot separation requirement or rivo foot requirement for systems installed 1996 or earlier,and which is not failing or an imr„inent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which mav or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soIl or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-7): � Tanl:inspection indicates: 5 Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. Tanlc was last pumped 3' - � ' �1��, ). Make sure septic tanks are pumped throuQh manhole and not throu�h white inspection pipes. This allows for the proper cleaninQ. Keep water softner and iron flter dischar6e out of septic system to prolong life of drainfield. Ask pumper to test alarm float to verifv alarm is still working in your house. The alarm warns owner that septa�e is about to backup into basement. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tanl:. If tanl:s have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION(8-10): � 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. COMMENTS: Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requuemenu for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under ciurent