HomeMy WebLinkAbout2016-00111 - mechanical . CITY OF ORONO * z 0 1 6 - 0 0 1 1 1 *
2750 KELLEY PARKWAY DATE ISSUED: 02/03/2016
ORONO, MN 55356-
(952) 249-4600 FAX: (952) 249-4616
ADDRESS : 100 CREEK RIDGE PASS
PIN : 03-117-23-12-0016
LEGAL DESC : CREEKSIDE IN ORONO
: LOT 005 BLOCK 001
PERMIT TYPE : MECHANICAL
PROPERTY TYPE : RESIDENTIAL
CONSTRUCTION TYPE : MECHANICAL-MULTIPLE
VALUATION : $ 48,565.00
NOTE: (1)LENNOX NAUTRAL GAS FURNACE
(1)TRIANGLE TUBE GAS FURNACE
(1)LENNOX A/C
(1)KITCHEN EXHAUST-6"DUCT-600 CFM
(6)BATH EXHAUST-80 CFM
APPLICANT MECHANICAL 607.06
STATE SURCHARGE MECH(VALUATION) 24.28
MASSMANN,GEOTHERMAL&MECH MAIL-IN FEE 2.00
27944 96TH STREET
ZIMMERMAN,MN 55398 TOTAL 633.34
(763)416-5066 Payment(s)
Minnesota State License#: mech-MB003981 CREDIT CARD 7350 633.34
OWNER
PETERS, BARRY&KRIS
19210 HACKAMORE ROAD
CORCORAN, MN 55340-
AGREEMENT AND SWORN STATEMENT
The work for which this permit is issued shall be performed according to
the approved plans and specifications,applicable Ciry approvals,and the
State Building Code. This permit is Yor only the work described and does
not grant permission for additional or related work which requires separate
permits. All provisions of laws and ordinances governing this type of work
shall be compied with whether or not specified herein.This permit will
expire and become null and void if construction authorized is not
commenced within 180 days of the date of issuance,or if construction is
suspended for a period of 180 days at any time after work has commenced.
The applicant is responsible for assuring all required inspections are
requested in conformance with the State Building Code.This pemiit may be
revoked at any time for due cause.
i
r
C`�a�c� o � � � � l.�
Applicant Permitee Signature Date Issue Signature Date
� � �R Tl"ti5E OtiLY'
�OA rO Cit}�of Orono
��! P.O.Rox tih [?ate Recei�� � pecmii� �d� �� ��
2?�0 Krliey Pazkµ'av
Cnstal Hav.tifN 55323 Appro�'ed IIy: � Amaunt 5: �3 3
� �; pi�anc(95Z1��9—iEOt) �ax(95F)�49-9GMG
l� ) i
� ,, � .�
� 4`, ' CITY OF ORONQ—��E:�Ht��ti1C�L PERi�11T
������#�l� � (All Commcrcial perm[n must he�ppm��eet by thr F3uilding(7llici:�1 or(nspectc>r ancVur Fir�Marshalll
GENERAL INFORMAT(ON
1. Yau may ap�C}' tor mcchanical pennits by mail or in persc�n at thc Cit}'otliccs. Applications will
be revicwed anci a permit wil!be issued within tw�wvrking daYs•
2. Pennit cards ti��ill be scnt by rcturn mail ztter a revic�ti�is completcd. PI:RMIT'S ARE: NU��
VALIU UN"('Il.. �'UU RFC FI�%E A PERMIT. «'�RK !LiUST ti�T BEGIN I�NTiL TNE
PE:RI��11T CARD IS Pt)STEU C)!1"f�{E JOE3 SITH.
3. ;�techanical Dr:i�;ns—Com�lete calculations,detail_r an�1 sprciticati�ns are rryuired fur ea�h
heating, vcntil�ttiun,hutniclitication-�(ell�miditicatiun,and air cun�itiuninL installati��ineluding
heat loss��heut�ain calcu(atit�n,desi�n temperature;.eyuipmznt ritin�s an�l i�ientific3tic�n as tc�
ry�c,manufaeturer anti nwdel_ D�iia sliall be presenttd un ti�rm pr�ivi�ed.
4. ���hen anv nc�v constni<tion or ren�ad�ling is im�olved,a scparate building permit must be
obtain�d.
5. All �4ork must be dor�c in accordancc with the Unifi�rm lvtrchanical Code�State Building Code
requirement�.
(. Ail work must be inspeeted{rt�ugh-in anc� tinal). Gall�9>2)?d9-�ifit}O.
(24-�t8 huur notice requircd)
7. F�Io�ise Heating Tcst Record miist be submitle�bef'Qre tit�al.
TYPE nF PERh1IT
Check All That A !
❑ 1t��idential ❑Commcrcial(Appr<n•al Rrquirrd)
�le.w� ❑ Additional ❑ Repairs ❑ Replace
Job Site/Owner Informatian:
Sitc Address: �V V ����������������.v��� ��� `� �� .���
Owner:��\I`� �:��� ����1 �� ���+�•����"�►il i�n�.= Adclress: 't"" � ���' �Ju'�
c�cy: �v�G��1�..�'�(���'� zi�: �CJ����
Home Phane: Alternatc Phone: `��J " ��� ���,�
ContractQr Information:
Gontrat;tor: ���l�J`(\n Gt�i'\��t����t�c t P�rsQn: ���� �f�.��YV�(.1,V�.V�.
Address:��""t�� �1�=%���-�.���tate Bond #: ��Jtj�J'� D�
City: �,1�`�..-���� Zip���� Expir�tion Date: , ������"`����.
Phone: '��'�� 1"��� �lternate Ph��ne:
� Insurance —Current: ������
I ����
_._____-- ----- —
��.1�C�ANICAI.S�'�'�EIviS��EING P�tSTALLEI>
Nute: AIl Geothermal 5ystems will iiow� require a Site plan c� Revie�ti�by our Bitildiiig Otticial.
IS THIS GEOTH�RMAL? ❑ Yes �No
HEATTI'�G SYSTEMS
Quantity: �_. +
vlake: ,�..f�!'1�'1 �.'�C �Yl�H�G �-t•��.e.
�z���: s�pa�u�iroxY�oc� .S�Ia !r o
Fuet: �� �•�'s�
Flue Size:
3" �'`
�p�ut BT��: �I�,�a� �10,oeo
ou�ut s�rt�s: /07, 2t� ..� t�S� Co�
CFM: ��G�� �''�
C0t3LiNG SYSTEMS
Quantity: � _
Make: G,+�vtY'!o�"
I�4odet: ,f L .�S --d�� i2.�Q
Tons: �
H. Power
FIREPLACES
❑ Gas Factory Fireplace Brand Name:
❑ Wood Burning Firepla�e
❑ Wvod Stove Model No.:
[] Waod Stove with Flue 1 Masonry
VENTILATION
,,� �'�3c�, 1 Kitchen Exhaust '� duct recirculating Gt D cfm
,(� I'�o. �_ Bath Exhaust(must have duct outside} �_cfm
❑ No. Other Fac�s: Locatians cfm
FUEL STOR.�►GE (t�lust be approved bv Fire Marshal!if proposing to abandon tank in plac�)
❑ Installation ❑ Removal
Fuel C3i1: gallons ❑ Underground ❑ Inside ❑ Outside
LP Gas: gallons
Other:
GA5 LINE ONLY
❑ Outdoor Grill ❑ Other 1 I,ist What&Wliere:
2
� � �� � �� � �� �PERMIT FEE GALCULATI0�15 �� ° '
1. CO�"I�RAC"T PRICE * is 1.2�°lo t�f cc�r�tract price���ith a(fitinimum Fee of�5(1.00)
��i,.��P�, 4� x .t�I�S 5 �PL��. ��
Icontract price) (minimum SSO.OU)
2. STATF. SURCNARGF,
x .0005 � c� y ��
�«,���a<<����e,
3. PC7STAGE� HANDLING (Only c�n N1aii-In�p�licat�ions) $ 2.U0
4. T�'TAL PER�'ICT F�:B(r`�dd Lines i-3 .�boc�) $ �� ��
� * COti'TKAC'T PRIC:E e�r JOB COST mcans th� actuat vr estin�ated dc�ilar amoun� eharged lur die
permittcd tivark inclitding matcn.�ls, labe�r, protit.and t�ther �xcd cos[s. It is the ail�ount to t�c chargcd
to the customer for lhe tivork ciune. If any matcrFal,eyuipment,labc�r or installations�ue furnished by thc
owner, tenant or any othcr party, thc reasonable market value of such items must be added to thc
estimat�d cust or ct�ntrart price for permit fre piupuses. ln thc c:vent thait there is a ciispute on thc amount
uf the jab cvst, thc City rrt7ciy rcyucst thc suhmissian vf a signcd co�y af the actual cantract.
�— MECHANICAL PERMIT APPLICATION AGREEMENT
"I�he undersir�ntd her�;by applies to the C�ity 1or issuance of a hlechanical Permit, agrees to do all
wc�rk in strict accc�rd�nce ��ith the urdinances of the City and the regulations of the State of
MinnesQta,and certities that all stat�;nlents made on this ap}�lication arc ct�mplete,true and cr�rrect.
Applicant's Signahue: _ �Dat�: ,�—
/`� ���
-�`5� �
� ��
�
� Load Short Form J�b�
� � � MASSMANN Date: Feb 01,2o�s
� � .0 .. En�ire House By�
Massmann Geothermal
1r�34.96tr�Si Nt^J Z�mr*�arman Mh 55398 Pnone 763�389-0376 Faz� 763-389•OJ86 Emad taso�La?m3ssmann�ep�herma�com Web�wwvmassmann�eothennai com
• ♦ !
For Gordon James, Perters& Barfknecht
Lot 2 Block 2 Oliver Hill, Medina, MN p*,,�,�� Y 3,�.� ^` '°���;��
� 4 i ..i .t'y� . �- ..
.. . s�_. . . ..
� : • M ♦
Hig Cig Infiitration
Outsids db(�} -22 97 Method Simplified
Inside db(�'} 72 75 Canstruction quality Semi-tight
Design TD (�) 94 22 Fireplaces �
Daily range - M
inside humidity(%) 35 50
Moisture difference(gdlb) 41 50
NEATING EQUIPMENT COOLING EQUIPMENT
Make Make Enertech Manufactunng LLC.
Trade Trade
Model Cond
AHRI ref Coil
AHRI ref
Efficiency 140 AFUE Efficiency 0 SEER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh �atent ca�ling 0 Btuh
Temperature rise 0 � Total cooling 0 Btuh
Actuai air fiow 1566 cfm Actual air flow 1566 cfm
Air flow factor 0.015 cfMBtuh Air flow factor 0.447 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space theRnostat Load sensibie heat ratio 0.91
ROOM NAME Area Htg ioad Gg load Htg AVF Clg AVF
(ftz) (Btuh) (Btuh) (cfm} (cfm)
Garage Zone p 1074 14130 0 212 �
Main Zone p 1$65 29726 15Q59 447 701
U pper Zone p 2701 45764 18816 687 876
�ower Zone p 1795 1�t611 4436 219 206
Entire House d 7435 104233 33415 1566 1566
Other equip loads ��� �
Equip. @ 1.02 RSM ��3
Latent cooling 3�
TOTALS 7435 114716 37378 1566 1566
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
`�" wri htsOft zo�s-Feo-4�o�40 1s
g RghtSuite�Urn�.ersai 2013 13.0 tt RSWtl282 Page t
,'��-,���' Pro{ect�.rup Cak=MJB Front Doar laces�. N
� Pro'ect Summa Job:
' � � MASSMANN � � oaee: Fee o�,�o�s
� � , _ Entire House Br:
Massmann Geothermal
279a3 gftn St NW.Z�mnertrwn.MN 5539&Phone�. 763-389-0376 Fax 763•389-038& Ema�l �ason(i�massmanngeothermal.cam Web.w`wwrtv�issmanrycre7lhermai com
• s e
For. Gordon James, Perters& Barfknecht
Lot 2 Block 2 Oliver Hill, Medina, MN
N otes:
i : • s •
Weather: Minneapolis-St. Paui, MN, US
Winte�Design Canditions Summer Design Conditions
Outside db -22 � Outside db 97 �
Inside db 72 `F Inside db 75 �
Design TD 94 � Design TD 22 �
Daily range M
Relative(�umidity 50 %
Masture difference 50 gdlb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 104233 Btuh Structure 33415 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent (209 cfm) 104&i Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 114716 Btuh Use manufacturers data n
Rate/swing multiplier 1.02
Infiltration Equipment sensible foad 340$3 Btuh
Methai Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 3294 Btuh
Oucts 0 Btuh
Heating Cooling Gentral vent (0 cfm) 0 Btuh
Area (ft2) 7435 6361 Equipment iatent load 3294 Btuh
Volume(ft') 55739 46073
Air changes/hour 0.25 0.13 Equipment total load 37378 Btuh
Equiv.AVF(cfmj 232 100 Req. total capacity at 0.70 SHR 4.1 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make Enertech Manufactunng LLC.
Trade Trade
Madel Cond
AHRI ref Coil
AHRI ref
Efficiency 1QOAFUE Efficiency OSEER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh l.atent coaling 0 Btuh
Temperature rise 0 '� Total cooling 0 Btuh
Actual air flow 1566 cfm Actual air flow 1566 cfm
Air flow factor 0.015 cfm/Btuh Air flow factor 0.047 cfm/Btuh
Static pressure 0 in H20 Static pressure � in H20
Space thermostat �oad sensible heat ratio 0.91
Calculations approved by AGCA to meet all requi�ments of Manual J 8th Ed.
+#+ wrightsoft ft�hl-SudeE Unrv�ecsal 2013 13A t1 RSUOC282 Z��`�F���� OPa0e15
9
'��'��'�` Pro�ee�1_rup Cak=MJ9 Front Door faces: N
� Load Multizane Summary Report Job:
' � �� � MASSMANN Date: Feb 01,2ots
� .. sy:
Massmann Geothermal
2754d gbfh Sl NW.Zirtrnerman,MN 55398 Phone� 765-3$9-0376 Faz 7$3�3$9-03$6 ��maJ�.�aso��massmanngeotherrnal.com Web� wwwmassmanngeotherrttaY.com
•
�C13Ul1�", ��W�tlt�
ZC1NEi NA;v1F �� �blurtx: At:H AVF t1TM Uc�tumr: ACIi AVfi Ift'tit
fl' c9m Btuhlft' ft' cfm Btuhift'
Garage Zone 9665 0.28 45 4 .4 0 0 0 0
Main Zone 16505 �.23 64 4,9 16505 0.12 34 0.5
Upper 2one 24309 0.28 115 4.4 24309 G.15 61 0.5
Lower Zone 5259 0.09 & 9.4 5259 0.05 4 0.5
Entire Hause 55739 0.25 232 4 .4 96073 0.13 104 0.5
2015-Feb-Ot 07:dp:15
'�' W PI �'1�SOft Page t
9 R1ght-Suittn4'UnWersel ZO1J i3 0 ti RSUQU282
��-���`�� Projectt.ruU Galc=MJ8 Front Dow taces; N
. . . .
R(�MNt��1E Arca }ftglc�d Clglckid HtgAVr CIgAVt=
ft' Btuh Bt�h cfm cfm
Garage i074 19130 0 212 0
Garage Zone :G'74 i4130 0 212 0
Great Room 440 8157 483I 123 225
Dining 198 7091 4289 107 200
Kitchen 300 193 38 3 2
Message Center 1�0 2980 I342 45 62
i.,aundry 72 '_152 924 17 38
Mudroom 265 471'1 2024 71 94
Mud WZC 41 0 0 0 0
Pawder Bath 40 0 0 0 0
Pantry 54 0 Q 0 0
Foyer 285 5127 1684 77 78
WIC 4 35 30� 26 4 I
Mud Colset 15 0 Q 0 0
Main Zone 1865 29726 15059 447 701
UL Ha11 274 577 317 9 15
Bonus Area 506 13474 5398 202 251
Bedroam 3 285 415� 18b8 62 87
UL Stairs 82 2E12 1138 39 53
L3pper BaCh 143 �3b3 781 35 36
Bedroom 1 204 378Q 121� 57 56
Master Elath 16� 1E48 906 28 42
Master WIC 170 3�#16 1207 51 56
Master Bedrom 522 6E07 2933 102 137
Bedroom 2 170 4323 2120 65 99
J&J Bath 180 2415 938 36 44
Upper 2ane 2701 45"7b4 18816 687 876
LL Hall 83 189 39 3 2
LL IIath 96 702 63 11 3
Bedroom #4 132 2G66 1123 31 52
Steam Roam 66 590 48 9 2
Mech Room 80 183 38 3 2
LL Stairs 120 1284 94 19 4
Play Area 190 2612 1358 39 63
Game Room 27p 616 128 9 6
Fami2y Room 560 4379 1395 66 65
W2t Bar 198 1989 151 3Q 7
Lower Zone 1795 146I1 4436 219 206
Eritire Hou�e 7435 i0423` 33415 1566 1566
-�- wri htsaft zo�s-F�-o,or<o�s
� Right-Suite'�Unrversal 2013 13-Q 7t RSUC10282 Paye 2
�`��'��"ti Prqect7.rup Cak�=MJA Front Ooor taces� N
� � r "'' , f I 'l ��'�'�`"�'�
$ � �. ,i �_, �h 1 `,; ; X � .�k
<.�; ��
� t a7� �. ;'��` _� i _ t�,. '��� - 1� �� �k� /f
-- : '� l-' 'f EAKA� '�� i� � �
,�� ����
��
Date of Test: 2/22/2016 Test File: Peters GJ-Return duct
Test Performed For: gordon james construction
5159 main street swuite 200
maple plain , mn 55359
Phone 763-479-3117
Test Results
1. Test Type: Total Leakage
(Duct Blaster Only)
2. Test Pressure: 25.0 Pa
3. Measured Duct Leakage: 75.8 CFM (14.3 sq. in.)
4. Duct Leakage as a Percent of System Airflow: 3.8%
5. Duct Leakage as a Percent of Building FloorArea: 1.3%
Additional Information
Duct leakage is often one of the largest sources of energy loss in a house. Leaky supply ductwork causes
expensive conditioned air to be lost before it can be delivered to the house, forcing your system to run longer to
keep you comfortable.
Leaky ductwork can seriously degrade indoor air quality by pulling pollutants and irritants directly into your house.
Leaky return ductwork can also pull moisture into your home, making it feel uncomfortable even when the air
conditioning is running.
�' , � ��� � `i�� ���,,� i [� � � ���� �` j I � Ll
. 41�_ t• ���_ y � � I
. . _ '�� - �`. �:.�� ��� � �� �.
�- ; ,� :
DUCT LEAKAGE TEST RESULTS
`� ���C���
Date of Test: 2/22/2016 Test File: Peters GJ-supply duct
Test Performed For: gordon james construction
5159 main street swuite 200
maple plain , mn 55359
Phone 763-479-3117
Test Results
1. Test Type: Total Leakage
(Duct Blaster Only)
2. Test Pressure: 25.0 Pa
3. Measured Duct Leakage: 87.3 CFM (16.5 sq. in.)
4. Duct Leakage as a Percent of System AirFlow: 4.4%
5. Duct Leakage as a Percent of Building FloorArea: 1.4%
Add itional Information
Duct leakage is often one of the largest sources of energy loss in a house. Leaky supply ductwork causes
expensive conditioned air to be lost before it can be delivered to the house, forcing your system to run longer to
keep you comfortable.
Leaky ductwork can seriously degrade indoor air quality by pulling pollutants and irritants directly into your house.
Leaky return ductwork can also pull moisture into your home, making it feel uncomfortable even when the air
conditioning is running.
/ �.�/l � �) /
� � TE E ;%�
CITY OF ORONO CALLED IN � J� '�^'
INSPECTION NOTIC SCHEDULED o2 - 3 —1 � __��Z�
PERMIT NO..�4 � COMPLETED '
ADDRESS ��� �--d-�� ��
OWNER TftEPHONE N0.7 3��D37�
CONTRACTO n ���v C
� DESCRIPTION G���
�
ly ❑ FOOTING DEMO-FINAL ❑ SEPTIC FINAL
Q ❑ POURED WALL ❑ PLUMBING RI ❑ EXCAV/GRADING/FILLING
Q ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL
Z ❑ RADON SLAB ❑ MECHANICAL RI ❑ SITE INSPECTION
Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ RATED WALLS
� ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT
Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP
_ ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ FOUNDATION/REMOVAL
v ❑ DEMO-SITE ❑ SEPTIC INSTALL
� OWNERICONTFiACTOR TO MEEf YOU:_YES_NO
� COMMENTS:
a �n --��' ��� -�
� � .
o ��1�.�,� v�c- a `` �'`���G' ��, `
� - _� -�rz��- �C�s �� a��� �
0
�
W �Q nv--�',c��_�
�
2
W
�
W
�
J
ATISFACTORY:PROCEED G PROJECT COMPLEfE
❑GORRECT WORK 8 PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY
O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY
V BEFORECOVERING PERMANENT
❑CORRECTUNSAFECONDITIONWITHIN HOURS. ❑ pf{OTOTAKEN
INSPECTOR W{LL REfURN
❑STOP ORDER POSTED.CALL INSPECTOR �CITATION ISSUED
❑ INSPECTION REQUIRED.CALL TO ARRANGE ACCESS.
C ' spection 24 hours in advance. (g52) 249-46�0
Ownerl tractor on site: ��
Inspector. �--
White Copyllnspector's File Canary CopylSite Notice
�J
't' i ��. �,. .,r �A j��4 TIME
CITY OF ORONO CALLED IN �
INSPECTION NOTI E SCHEDUI.ED
PERMIT NO. o2f�� "Od��� COMPLEfED �rT-!�
ADDRESS /� G��,�, R.���S�
OWNER TELEPHONE NO.
CONTRACTOR ���eil
� DESCRIPTION �'��• ���' �•! ��� ���
ly� ❑ FOOTING ❑ DEMO-FINAL ❑ SEPT�C FINAL
Q ❑ POURED WALL ❑ PLUMBING RI ❑ EXCAV/GRADING/FILLING
y ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL
� RADON SLAB
Z ❑ ��AQECHANICAL RI ❑ SITE INSPECTION
Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ RATED WALLS
� ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT
Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP
W ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ FOUNDATION/REMOVAL
_
v ❑ DEMO-SITE ❑ SEPTIC INSTALL
Z OWNERfCONTRACTOR TO MEEf YOU:_YES_NO
c�.� COMMENTS:
� /� n
� /CB4l��S �� �JG_G� ��t�.�c�S'7i
J� �i�G/c fi���
� � � � � � � ��
�
� K /i � r,c L<<ci.,tS— � ""_
W
2
Q
2 �� � ��,(/C�./
W
�
j /�f��/6dG .��1� ��12�- �U /i�C�
d
W� �'R�B�ATISFACTORY:PROCEED ❑ PROJECT COMPLEfE
�❑CORRECT VYORK 8 PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY
O ❑CORRECT WORK,CALL FOR REtNSPECTION TEMPORARY
V BEFORE CWERING PERMANENT
❑CORRECT UNSAFE CONDITION WITHIN HOURS_ ❑pHOTO TAKEN
INSPECTOR WILL REfURN
❑STOP ORDER POSTED.CALL INSPECTOR �CITATION ISSUED
❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS.
Call for the next inspection 24 hours in advance. (g52) 249-46�0
OwnerfContractor on site:
Inspector: � � .-. �
White Copyllnspector's File Canary CopylSite Notiee
;�-w�
�"� ������� TIME
CITY OF ORONO \`\���� °s
INSPECTION NOTIC `���,�, 1 SCHEDULED �v�
PERMIT NO. cOMPLEfED a a3l�
ADDRESS / G�'�G,L�►cQ �
OWNER TELEPHONE NO.
CONTRACTOR /_��QS f�r„�/l
� DESCRIPTION /yJec�- �z` �i•� �e�S�''� �
ty ❑ FOOTING ❑ DEMO-FINAL ❑ SEPTIC FINAL
Q ❑ POURED WALL ❑ PLUMBING RI ❑ EXCAV/GRADING/FILLING
Q ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL
Z ❑ RADON SLAB �'�ECHANICAL RI ❑ SITE INSPECTION
Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ RATED WALLS
� ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT
Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP
_ ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ FOUNDATION/REMOVAL
J ❑ DEMO-SITE ❑ SEPTIC INSTALL
2 OWNERlCONTRACTOR TO MEEf YOU:_Y NO
� CO � � �� �
�
� t �
0 3 ! / 'r i..� E �
�. •L�
�
� C�r✓" e5 � !� �JU ��2
W �� - -
� 6 v r���c,5
Q
�
z
W
�
W
�
j
d
W ❑WORKSATISFACTORY:PROCEED ❑ PROJECT COMPLETE
� ❑CORRECT WORK 8 PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY
W
� �RECT VYORK,CAII FOR REINSPECTION TEMPORARY
� BEFORECOVERING PERMANENT
❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ pH0T0 TAKEN
INSPECTOR WILL REfURN
❑STOP ORDER POSTED.CALL INSPECTOR �CITATION ISSUED
❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS.
Ca11 for the next inspection 24 hours in advance. (952) 249-46��
OwnerlContractor on site:
Inspector:
White Copyllnspector's File Cenary CopylSite Notice
�/�' s t 3���R •, /
� � �. , •.Y a
�►" ^�-'--�. ' V
� - ' DdTE �� TIME
CITY OF ORONO CALLED IN o�l -�
INSPECTION NOTICE SCHEDULED p�! �—1(,� �
PERMITNO.aO��lC�U�l� MPLETED
ADDRESS l��
OWNER TEL HON�O.
CONTRACTOR Q-.S_5���-Q-�I �����
r
� DESCRIPTION �! U� �`oYL-- � /i1��
ll� ❑ FOOTING ❑ DEMO-FINAL ❑ SEPTIC FINAL
Q ❑ POURED WALL ❑ PLUMBING RI ❑ EXCAV/GRADING/FILLING
Q ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL
Z ❑ RADON SLAB ❑ MECHANICAL RI ❑ SITE INSPECTION
Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ RATED WALLS
� ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT
Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP
�4 ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ FOUNDATION/REMOVAL
_
J ❑ DEMO-SITE ❑ SEPTIC INSTALL
2 OWNERlCONTRACTOR TO MEET YOU:_YES_NO
� COMMENTS:
�
W A i
a -
� � -
�
O
�" T�l(C �-I �I Ct�1 1 �S�
�
O
�
W
�
Q
�
2
W
�
W
�
�
d
W� ❑WO SATISFACTORY:PROCEED ❑ PROJECT COMPLEfE
W ❑ RECT WORK 8�PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY
� CORRECT WORK,CALL FOR REINSPECTION TEMPORARY
� EFORE COYERING
PERMANENT
❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ PHOTO TAKEN
INSPECTOR WILL RETURN ❑CITATION ISSUED
❑STOP ORDER POSTED.CALL INSPECTOR
❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS.
�
Call for the next inspection 24 ours in adva . ) 249-46��
OwnerlContractor on site:
�
Inspector_ i
�
White Copyllnspector's File Canary CopylSite Notice
r
C.�� ' jf
DATE TIME
CITY OF ORONO CALLED IN ==t=��
INSPECTION NOTICE �� SCHEDULED
PERMIT NO. cOMPLETED
ADDRESS �P�D �h�� lC- !�/ Q�� J�C.�SC
OWNER TELEPHON O. �l(J3e���( `O37k
CONTRACTOR `-7�� ��QS�'!'1�h
� DESCRIPTION ��1 �/vbr C�Y1�i�-,/oo-1
lL ❑ FOOTING ❑ DEMO-FINAL ❑ SEPTIC FINAL
Q ❑ POURED WALL ❑ PLUMBING RI � � EXCAV/GRADING/FILLING
Q ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL
Z ❑ RADON SLAB ❑ MECHANICAL RI ❑ SITE INSPECTION
Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ RATED WALLS
� ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT
Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP
W ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ FOUNDATION/REMOVAL
_
� ❑ DEMO-SITE ❑ SEPTIC INSTALL
2 OWNER/CONTRACTOR TO MEET YOU:_YES_NO
� COMMENTS: a��� \/� ��
W 10
a
0 ��l � �j�/' �c{�/ifG 6f/1� a �� /,��l�'
� a4/E� !K -�S / Q�
oC � .
° •• q.� t e� olaP�s ) G D,�sG .�
W
�
Q
2 6� �S C'6�'��
W
�
W
�
�
�
d
RKSATISFACTORY:PROCEED O PROJECT COMPLEfE
W ❑CORRECT VYORK 8 PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY
O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY
V BEFORECOVERING PERMANENT
❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ pHOTO TAKEN
INSPECTOR WILL REfURN
❑STOP ORDER POSTED.CALL INSPECTOR �CITATION ISSUED
❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS.
Call for the next inspection 24 hours in advance. (J52� 249-4600
OwnerlContractor on site:
inspector: �� / w �
White Copyllnspector's Flle Canary CopylSite Notice
,� _\
DATE TIME
CITY OF ORONO CALLED IN
INSPECTION, O ICE _ SCHEDULED ��� �—
PERMIT N� �'�� � COMPLETED
ADDRESS �CX7 Cr�-t�� �C � e ,� �_,g�
OWNER TELEPHONE NO. ��O-�� 3�� U 3 "]�'
CONTRACTOR ��¢�^
� DESCRIPTION ���41-� 1 Y ��1
W ❑ FOOTING ❑ DEMO-FINAL ❑ SEPTIC FINAL
Q ❑ POURED WALL ❑ PLUMBING RI ❑ EXCAV/GRADING/FILLING
Q ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL
Z ❑ RADON SLAB ❑ M��HANIGAL.FiL ❑ SITE INSPECTION
Q ❑ FRAMING ❑ MECH NICAL FINAL _�� ❑ RATED WALLS
� ❑ INSULATION �WOOD�EPLACE ❑ COMPLAINT
Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP
W ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ FOUNDATION/REMOVAL
_
J ❑ DEMO-SITE ❑ SEPTIC INSTALL
� OWNERfCONTRACTOR TO MEET YOU:_YES_NO
c�., COMMENTS:
�
W
a
�
J
O
�
�
O
k
W
�
Q
�
2
W
�
W
�
J
d
W O WORKSATISFACTORY:PROCEED PROJECT COMPLEfE
� ❑CORRECT WORK 8 PROCEED ❑ I E CERTIFICATE OF OCCUPANCY
W
O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY
V BEFORECWERING PERMANENT
❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ pHOTO TAKEN
INSPECTOR WILL REfURN ❑CITATION ISSUED
❑STOP ORDER POSTED.CALL INSPECTOR
❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS.
Call for the next inspection 24 hours in advance. �9 49-4600
OwnerlContractor on site:
Inspector.
White Copyllnspector's File Canary Copyl te Notice