HomeMy WebLinkAboutseptic info . -�w
� o�v. /
O � O CI'TY OF ORONO
� � Municipal Offices
v�,, ,�y� �, Street Address Mailing Address:
'C� G'�' 2750 Kelley Parkway P.O. Box 66
'�� '� Orono, MN 55356 Crystal Bay, MN 55323-0066
kESS��'
To: The Current Owner of Address 2780 COUNTRYSIDE DR W
City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a
periodic basis. The onsite sewage treatment system at the above address has been inspected and
the following is known about the system. A sketch of the known components of the system is
available for most properties at the Orono City Hall.
Imminent Public Health Threat
Yes �No
If yes, please contact the Onsite Systems Manager at 954-249-4626 within 10 days of receipt of
this notice. The septic system must be brought into compliance within 90 days. Failure to do so
will result in referra] to the City Attorney for legal action.
System Identified as Non- ompliant
Yes
No
If yes, system must be brought into compliance by:
December 31, 2007
December 31, 2010
Other
Septic Tank(s) Pu ut Needed
Yes
No
The city recommends the septic tank(s) and/or lift tank be serviced and pumped out every three
(3) years. City records indicate the tank(s) were last pumped out on � �{�c�C�
The tank(s) should be cleaned through the manhole and not through the inspection pipes, this
allows for proper cleaning.
Comments:
�i �-
Inspecto��{, .�C� � Date of Inspection: ����
Telephone (952) 249-4600 • Fax (952) 249-4616
www.ci.orono.mn.us
• � • •
e
To: Orono residents on mound type septic systems
From: Willie Gibbs, ISTS Manager
Date: May 10, 2006
Re: Landscaping Do's and Don'ts for Mound Systems, Quick Reminder
Do plant and maintain a full cover of grass and keep mowed to a normal height, this grass cover aids
in the evaporation of large amounts of effluent (the liquid left after the "other" stuff has been removed)
in the summer time and allows the mound system to help breakdown nitrogen in the effluent,
Do water the grass over the mound in extreme dry conditions, sparingly.
Do avoid unnecessary foot traffic over the mound, mow it and stay off of it. This is especially true in the
winter time. Even human foot traffic can cause frost to penetrate the mound resulting in potential
freezing problems.
Do inspect your mound system annually for winter kill, (reseed if necessary) animal damage,
(burrowing) or signs of potential failure.
Do n�t plant trees or shrubs on the mound system, smaller trees and shrubs may be planted at the
edges. Remember,that sunshine is the key to a heaithy mound system.
Do ask questions, if you have any concerns or questions concerning your mound systerr�
please feel free to call me, I can be reached at 952-249-4626.
1
.� o.�
o , o
��Y� �-� ! C ITY of ORONO
�
.a ''`�2��� � �►
�c -;�" ti�
'� �S�+�;,.� � . . Municipal Offices
'� ��,�`',�!��'ai��.\► G'ti
�,r,;;,�`� Street Address:
�9 ,¢�i Mailing Addross:
$'EgHO 2750 Kelley Parkway P.O. Bax 66
Orono, MN 55356 Crystal Bay, MN 55323-0066 .
To Current Owner: Address: �7$� C o�nt� S�c�e �!, w,
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3): �
( 1 J"CODE SYSTEM" An ISTS which meets all the location,design and conswction standazds of the current Orono Municipal Code.
�./
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal
Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or
an imminent threat to pubiic health or safery.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failins for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-'7): 6
Tank inspection indicates:
5 Pumpout not needed at this time.
�Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped S��-{—C�C� ).
Make sure septic tanks are aumped throu�h manhole and not throu�h white inspectioo aipes This allows for the
proper cleaning. Keea water softner and iron filter discharge out of seatic system.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia. pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD CONDITION 8-10 : �
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the Ciry Inspector
immediately. Repairs must be completed within 90 days.
COMMENTS: ���� 1n�kS �K _ �U►..�p sep�; � ����.5 -}�►.�S Su�.r+.ef�oy�
-7�1-o� � ��
Date of Inspection Matt Bolterman - Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report dces not guarantee
or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy ofthe system under curzent conditions based on the available
information.
Telephone(952)249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
� o�
,; O O
_�=::�f�__ I CITY of URONO
�� .��� �� .� �
�� � �: ��� � ti M�;��� ot��
� '�`�%'����r�� ~
.� "' �''<7V`- 1:� �G Street Address: Mailin� Address:
9 � ' ,`'.'r 4�
$EggO 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystai Bay, MN 55323-0066
Owner: ` � Sq Se �n,AC'd Address:_a��jo Co�,�-�ys;d� d� W_
Cin Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected er-ery tt��o years.
The on-site se«�age treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTE:�i CONFORMITY (I-3): �
O ��C�DE $YS�NT" ,�n ISTS which meets all the location,dzsi�and construction standards of llte current Orono\hmicipal Codz.
2 °CONfPLIANT SYS'I'EM" An ISTS which dozs not mzet all the location,desi�and construction standards ofttY vrrent Orono�funicipal
Coda but dozs meet the thtea foot sepazation requ'uement,and which is not failing or an�mminent threat to public heaYLh or safety.
3 ��NON-COI�fPLIANT SYST'EM° A prohibited ISTS;an ISTS located within a desigiated 100-yeaz flood plaia any ISTS which may
or mav not meet all the location,dzsigt,or construction standazds of thz current Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil ch.���ristics.
TANK CONDITION(�-10): C�
Tank inspection indicates:
� Pumpout not nzedzd at tltis timz.
UTank must bz pumpzd out this year (city code requires tanks to ba pumped out evzry 3 years. Tank was last pumped U n�n d"v^ ).
� Solids accumulation in tanks is at a critical a critical Izvel. Tanks should ba pumped out as soon as possible.
g System is discharging to the surfacz. Tanks must be pumped out within 48 hours to eliminate surface dischazge.
9 Inspectiun risers missing-tanks could not be inspzeted. Inspection riszrs(4"dia.pipe)must ba installed in each tan(c at o:�pumpout If tanks
ha��e not been pumped out within thz last threz years,they should be pumped out now.
1� Inspec[ion pipe is located directly over tank ba81e(does not give accurate mzasurement of solids accumulation). If tanks havz not bern pumped
o�[within the last threz years,they should ba pumped out now.
DRAINFIELD CONDITION 11-14 : �_
1 1 Drairtfield is dry,no surfacing evident.
1� Some evidence of surfacing,not critical yet
13 Drai�eld is saturated and visibly discharging untrzated etfluent to the surface. Contact the City Inspector immediatzly.Rzpairs must be
completed within 90 days.
1-� Drainfield extent and condition unknown.
COMMENTS: r�Mp tq�ICS , Sy,�te n, I �ok5 d k
6-1�-6 � �1� /�-a�2�.a,,,...
Date of Inspeclion Seplic System Inspector ;
Notz: In the zvent that this inspection repoR is used to satisfy the requitemenLs for a moRgage or other transfer of property,be ad�-iud that this report does not guazantee
or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under�wr�t conditions bued on the availabla
information.
o C���
� �
0 0
CITY of ORONO
� � � � �
l4 Municipal Offices
ti
�,t� ¢.�G Street Address: Mailing Address:
�ESII� 2750 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
y ,
Owner: �i Address: 2760 Countryside Dr. W.
Permit #'s: 7328 Dates: 9/11/95 Contractors: Clover Hill Co.
(This is [x..] an existing system [ ] new construction) .
,S�STEM COMPLIANCE (1-3) : 1
�� Code System: Meets or exceeds current City standards in all respects relating to design,
�" construction, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for new construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
3 Non-Compliant System: System may or may not meet current City standards for design,
construction, or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom of
the drainfield and the saturated soil level.
(The saturated soil level is [�] or is not [ ] identified under this septic system. If the
saturated soil level is not identified, this classification is subject to revision.)
TANK CONDITION (5-9) : 9
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out
within three years, they should be pumped out and risers installed now.
� Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
10 One or more tanks are cesspools, which means the septic system is - ompliant.
(The tanks are [� ] or are not [ ] water tight or the condition is [ ] unknown. If the tanks
are not confirme" to be watertight, this classification is subject to revision.)
INFIELD COVDITION (11-14) : 11
11 Drainfield is dry, no surfacing evident.
12 Some evidence of surfacing, not critical yet. Repair is not required at this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact
the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : low
COMMENTS:
��� ,.l�C G /�"�/
Date of Inspection ep ystem I spector
Note: In the event that this inspection report is used to satisfy the requirements for a
transfer of property, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Telephone(612)249-4600 • Fax(612)249-4616
CITY OF ORONO � O�
Municipal Offices O O
Post Office Box 66
Crystal eay, MN 55323-0066 � � ON—SITE SEWA(3E TREATMENT
r�, � INSPECTION REPORT
�' G~
/ �—^ 1
L�cS� JE'��'�� �kESH04'�
r- -�_ r� � � /, )
Owner: , Address: � ` �' + Vv
Permit #'s: Dates: i`""�/—%� Contractors: '
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
7he on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is [ 7 an existing system �new construction)
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
uithout discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current seuage input without discharging
any pollutants tnto ground or surface waters.
3 "NON-CONFORMING SYS7EM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system uith less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic lyC�L has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10):
tienk� inspection indicates:
l,�J Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be punped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out uithin 48 hours to eliminate surface dischar�e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next purtipout. If tanks have not been pumped out within the last three years, they should be pur�ped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out uithin the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
D i ield inspection indicates:
1 Drainfield is dry, no surfacing evident.
1 Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City inspector
irtmediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING S1TE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): ��
COMMENTS:
Date f Inspection Se ic Sys e Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the pre�nises with the system loc=tien and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner