HomeMy WebLinkAboutseptic info ; --�
� ��
� �\
, / O O `,
� CITY of ORONO
�� � �
a �;' r,�'�;� �, ;
�1. ��i`' �C, :� Municipal Offices
"�+" �; Z� ' � ti,
�`���� ��� � '��� ��,��;����� Street Address qSa'a4q��6� � Mailing Address:
`�kESH�g 2750 Kelley Parkway P.O. Box 66
-- - " Orono, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: Address: �4 aC ��'"�'��7 S:d e U�,
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3): �
( 1 )"CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code.
\J
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono
Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and
which is not failing or an imminent threat to public health or safery.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which ma}
or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is faIling for any
reason;and any ISTS with less than three feet of unsaturated soil or sand between the dis�ibution device and the limiting soil characteristics.
TANK CONDITION(5-7): �
Tank inspection indicates:
5 Pumpout not needed at this time.
�Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
Tank was last pumped ).
Make sure septic tanks are pumped throu�h manhole and not through white inspection pipes. This allows for the proper
cleanin� Keep water softner and iron filter discharQe out of septic svstem to prolon�life of drainfield. Ask pumper to test
alarm float to verify alarm is still workin�in vour house. The alarm warns owner that septage is about to backup into basement.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4" dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD CONDITION(8-10): �
�Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMMENTS: �t�,.�C-:e,�c� �oc�� �\L , P u�-� S�Q ��� ����1�5 S�r:;��,
�o 0 5 _ �= .x cG�S �� ��kS _
�-�--� -o� '�� D ��
Date of Inspection Matt Bolterman - Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does
not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under curren[
conditions based on the available information.
� o�
o_:_:,: o
�-1==����=� C ITY of ORONO
a� A���`��:�`�� �
� ` ti M�;��� ot���
.�; ;�;:-.��� ti
� ..,;;,���i;,:���, G
� �;,, -��,���_
.��! „�Vr,;� g� Street Address: Mailing Address:
$'EgKO 2750 Kelley Parkway P.O. Bax 66
Orono, MN 55356 Crystai Bay, MN 55323-0066
95d-�4q-4640
To Current Owner: Address: a `� ��� ��'��?�y 5 ;�)L p T
City Ordinance 199 requires that each existins on-site sewage treatment system in Orono be inspected every rivo years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMITY (1-3): f
1 "CODE SYSTEM" An ISTS which meets ail the location,design and construction standards of the current Orono Municipal Code.
2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,desi�and construction standazds of the cuaent Orono Municipal
Code but does meet the three foot separation requiremen[or two foot requirement for systems installed 1996 or eazlier,and which is not failing or
an imminent threat to public health or safery.
3 "NON-COMPLIANT SYST'EM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may
or may not meet all the location,design,or conswction standards of the curtent Orono Municipal Code and which is failing for any reason;and
any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil charactcristics.
TANK CONDITION(5:��: �
Tank inspection indicates:
5 Pumpout not needed at this time.
� Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years.
Tank was last pumped `� -;_`�t> )
1�Iake sure septic tanl:s are pumped through manhole and not throu�h white inspection pipes.
This allows for the proper cleaninE.
7 Inspection risers missinb tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank.
DRAINFIELD CONDITION($-�Q�: �
� Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector �
immediately.Repairs must be completed within 90 days.
COMMENTS: � �f S-4-t� 1 c;c�S �j� _ �'���,�f,i -�.,.\� t� �x+�� f�,�c �-��
� 1
.1C -�" ��-_t\-J _ Ytir iCJCf7 C�� �..'�,Y` :����L�'�.�1 �Q�`�:� �'G ��tA .SUI�,<C
�"��C r � -' '� �'� �^�'~ - -
�J - �—C���-. G��ci:tC ��2,r-�..�—
Date of Inspection Matt Bolterman- Septic System Inspector
Note: In the event that this inspection report is uscd to satisfy the requirements for a mortga�e or other transfer of property,be advised that this rcport does not guarantee
or certify that an existing system will continue to function properly,but is merely an opinion ofthe adequacy ofthe system under current conditions based on the available
information.
o ��;
� � ;
��o o��,����
�� �� CITY of ORONO
� r� • �
;s. !� MunicipalOffices
�� ��' G~ Street Address: Mailing Address:
�������`�$'EggO�'�!� 2150 Kelley Parkway P.O. Box 66
-_-___=�� Orono, MN 55356 Crystal Bay, MN 55323-0066
May 1, 2000
Paul & Rita Nathanson
2420 Countryside Drive
Long Lake, Mn 55356
Dear Mr. & Mrs. Nathanson:
An inspection of your septic system was conducted on April 25, 2000. A summary of the inspection
is below.
Se�tic Tank Condition
l. Pumpout not needed at this time.
The septic system is a compliant system, meaning it meets all or most current City and State
Standards. Enclosed is a list of licensed contractors who work in Orono on a regular basis. This
list is enclosed simply for your reference in case your septic system needs maintenance in the future.
Also enclosed is a fact sheet explaining your septic system and how it functions. Finally, an as-built
drawing is enclosed showing the approximate location of the septic system.
If you have any questions regarding this report, please contact me at the City Offices at 249-4600.
Res ectfully
� �
� �.c�'
Chris Pence
On-Site Systems Manager
Enclosures
In the event this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,
be advised that this report does no guarantee or certify the e�sting system will continue to function properly,but
is merely an opinion of the adequacy of the system under current conditions based on the available information.
This report must be kept on the premises with the system location and pumping records.
Telephone(952)249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
CITY OF ORONO � O�
Municipal Offices O � O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT
r�, � INSPECTION REPORT
ti
���kESH�g'�G
r �
Owner• �����"�/ll/ �C.4r1�� Address• a��%�[ �1//�'������ Y/!�
.
Permit #'s: Dates: //;�d�J1C� Contractors: �/.�Y7l���Y� �/��
.
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is � an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3): �
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and uhich is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface uaters.
2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the
current City Codes, but Was installed according to the code in effect at the time of installation, and uhich
is operating satisfactorily by treating and disposing of the entire current sewage input uithout discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located uithin a designated 100-year floodptain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system uith less than 3 feet of unsaturated soil or sand
betueen the distribution device and the limiting soil characteristics.
(7he limiting soil characteristic (�has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identi'fied, this classification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be p�xnped out within 48 hours to eliminate surface dischar�e.
9 Inspection risers missing-tanks could not be insPected. lnspection risers (4�' dia. pipe) must be installed in each
tank at next pumpout. ]f tanks have not been pumped out within the last three years, they should be p�xnped
out now.
�0 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been putiped out uithin the last thrPP_-vaa�S, t sh u be pumped ou now �
� ,
� t� s �is,'s y�,%
DRAINFIELD CONDITION (11-14):
r nfield inspection indicates:
Drainfield is dry, no surfacing evident.
2 Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated eftluent to the surface. Contact the City [nspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): 1�, �—��L.�.,.__.._
�/s�
O ENTS: ,S � / � � � / �' C�i/'�J
YT /' � .�-
E?
Date of Inspection Sep ic Sy em Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an exisxing system uill continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the prE�nises with the system loc�tion a�d pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
CITY OF ORONO � O�
Municipal Offices O � O
Post Office Box 66
Crystal eay, MN 55323-0066 a � ON—SITE SEWAGE TREATMENT
� � INSPECTION REPORT
ti
���kESHa4'�G
Owner: 7C7�1�`+�l�i� /l,�Gl��";�1''` Address:_�7�� � Y1/Si�(?; �l:
Permit #'s: Dates: ��-�i �� Contractors: /�/h�5(�(� Y"K:4.
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is I�7 an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3):
"CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYS7EM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic� has or [ ] has not been identified at this time. if the limiting soil
characteristic has not been identi ied, this classification may be subject to revision.>
TANK CONDITION (5-10); �
Tank inspecti indicates:
5 P u �t needed at this time.
y.., accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
C7� � accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 ystem is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
9 Inspect�on risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next purtipout. If tanks have not been pumped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
Dr field inspection indicates:
1 Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMI7ING SITE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): �/��IJY?'\
COMMENTS: ' �����` �.. Q .� �jj'�,
��./ s /' �. C� r"
�
_ �.
Date of Inspection e tic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
informatton.
This report must be kept on the pre�nises with the system loc�±ien and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
���,
�j/ � �\\`,
� ` �
; ° ������1 Y o� o�o�
, +,: , :_. - Ii C�T
�, r� ,� �t , ��,� Municipal Offices
�.. ,� %
� �� "4 Mailin Address:
'. 'C� �I�"' ' � .`:�,;� �;!� Street Address: g
,, l , ,.; , �;;' P.O. Box 66
:�. <Q � 2150 Kelley Parkway
�, kESI3� %%' Crystal Ba MN 55323�D066
� ���____� Orono, MN 55356 y�
To: The Cunent Owner of Address � `� +�� C��ti-�-r`{-�� `�I� t� r.
City Ordinance requires that onsite sewage treatment systems in Orono be
inspected on a periodic basis. The onsite sewa�e treatment system at the above
address has been inspected and the following is known about the system. A
sketch of the known components of the system is available for most properties at
the Orono City Hall.
Imminent Public Health Threat
Yes
No �
If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10
days of receipt of this notice. The septic system must be brou�ht into compliance
within 90 days. Failure to do so will result in referral to the City Attorney for
legal action.
System Identified as Non-Compliant
Yes _�_
l�o W
If yes, system must be brought into compliance by:
December 31, 2007
llecember 31, 2010
Other
Septic Tank(s)�mp out Needed
Yes V�
No
The City recommends the septic tanl:(s) and/or lift tank be serviced and pumped
out every three years. City records indicate the tank(s) were last pumped out on
� �- �_�� . The taril:(s) should be cleaned throuQh the manhole and
not through the inspection pipes, tlus allows for proper cleanin�.
Comments:
,� � �"A Fi `� -C� C..
Inspecto:`��� ¢ ' ��� Date of Inspection ;, r,
Telephone (9�2) 249-4600 • Fa� (9�2) 2-19-461fi
On the North Shore o f
Lake Mi�rnetorzka
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT � POST OFFICE BOX 66
1335 S. Brown Rd.
� � � Crystal Bay, MN 55323
473-7357
� �
OWNER � ��� � � ADDRESS � _
PERMITNO.'S. �U�'� DATES `���V�� CONTRACTORS --�C��[t�•
�J
City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is � an existing system ❑ new construction)
{� � Meets or exceeds current City standards in alI respects relating to design,construction,and location.Appears to be operating
��� properly.
� 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes. System appears to be functio�ing properly;no major
upgrading of the system is required at this time.
❑ 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
� 4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and
dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is
creating a safety hazard, or is otherwise creating a public�uisance.P�ease contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary, soil testing will usually be required,and a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( m Checked items may require your action)
Tank inspection indicates: ��.Inspection pipe is located directly over tank baffle.(Does not
❑ Pumpout not needed at this time, give accurate measurement of solids accumulation.) If tanks
❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they
ed out this year to help prevent future problems. should be pumped out now.
❑ Solids accumu�ation in tanks is at a critical level. Tanks Drain ield inspection indicates:
should be pumped out as soon as possible. '�Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge, ❑ Drainfield is saturated and visibly discharging untreated
❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace-
Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days.
the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Futur Expansion
❑ Soil table nd system condition) �,4dequate
❑ High water table �Low ❑ Fair
❑ Lot size ❑ Medium ❑ Poor
❑ �ake,wetland,or stream ❑ High ❑ Inadequate
❑ Drainage ❑ System is causing visible
surface di charge.
COMMENTS: ��v, Y.C� ��' � ,� E1
� ns�r � f--�a �
�
� � � -
?�3`I�
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to functio�properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/�nspector's File GOLD COPY/Homeowner
On the North Shore of
Lake Minnetorika
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT � POST OFFICE BOX 66
� . � � 1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
OWNER �'"G��/� f/�TQ �/�»S�1"1 ADDRESS ���C��'L��/ �� �
�>/ > 7'
PERMIT NO.'S. x d , DATES ������ CONTRACTORS J
City Ordinance No, 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage
treatment system at the above address has bee�inspected and appears to fall into the category checked below.
(This is ,� an existing system ❑ new construction)
� � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
properly.
� 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
Iocated, a�d constructed generally in accordance with previous codes. System appears to be functioning properly; no major
upgrading of the system is required at this time.
� 3 Does nat meet current City standards in many respects relating to design,construction,or location.Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
� 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and
dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is
creating a safety hazard, or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan
must be submitted fo�review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( m Checked items may require your action)
Tank i�spection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not
❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks
�.Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they
ed out this year to help prevent future problems. should be pumped out now.
❑ Solids accumulation in tanks is at a critical level. Tanks Drai field inspection indicates:
should be pumped out as soon as possible. ,�I Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surtacing,not critical yet.
within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated
❑ Inspection risers missing—tanks could not be inspected. effluent to the surface, This co�dition may require replace-
Inspection risers (4"dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days.
the last three years,they should be pumped out now. ❑ Drainfield extent and co�dition unknown,
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Future Expansion
❑ Soil table and system condition) Adequate
❑ High water table � Low � Fair
❑ Lot size ❑ Medium ❑ Poor
❑ Lake,wetland,or stream ❑ High . ❑ Inadequate
❑ Drainage ❑System is causing visible
surface discharge.
COMMENTS:
7-/9-9� -
Date of Inspection S tic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/ Inspector's File GOLD COPY /Homeowner