HomeMy WebLinkAboutseptic info CITY OF ORONO � O�
Municipal Offices O � O
Post Office eox 66
Crystal eay, MN 55323-0066 a � ON—SITE SEWAGE TREA'I`MENT
„� � INSPECTION REPORT
ti
��9kESH�4'�G
Owner: �C�+6' UI� .�} ►11�'\ Address: .
' - £�c ��sa�
Permit �'s: �S Dates: " ontractors:
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked belou.
(This is,J� an existing system [ ] neW construction)
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
uithout discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
"NON-CONfORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and an s stem with less than 3 feet of saturated soil or sand
between the distribution device and the limiting soi c arac e s ics. ���� � I� J�
,�(The limiting soil characteristic;�l�has or [ ] has not been identified at is time. If the limiting soil
characteristic has not been identi'fiied, this classification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to hetp prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
� System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
[nspection risers missing-tanks could not be ins cted. In�n c�ti„on risers (4" dia Rj.�) m�cr hP ;ncrall d in Parh
■
tank at next t. If tanks have not een puniped out wit'fiin etTi`last th ee year , t y should
ou ��
10 Inspection e is located directly over tank baffle (does not give accurate mea uP� s l s a c la�io ). •
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRA[NFIELO CONDITION (11-14):
D�field inspection indicates:
/ 1]t' Drainfield is dry, no surfacing evident.
�`12 Some evidence of surfacing, not criticat yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
imnediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.): � �
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): � �vrr�
rir1E Ts: - � r � �' �
��n
'�- r- � �'
Date of Inspection e ic ystem Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system wilt continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the prEmises with the system locatien and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
CITY OF ORONO � O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT
� � INSPECTION REPORT
ti
��9kESH��'�G
" � Cv .
Owner• / /,Cd 1�/I�'�1'�1 Addres s•
Permit �'s: Dates: ��i��'�/�p"/�'�ontractors: .�
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is f�an existing system [ ] neu construction)
SYSTEM CONFORMITY (1-3):
"CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface uaters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and uhich is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic [ ] has or L�L has not been identified at this time. If the limiting soil
characteristic has not been identified, this c[assification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
� System is discharging to the surface. Tanks must be pumped out uithin 48 hours to eliminate surface discharge.
Inspection risers missing-tanks could not be inspected. Ins ecti ' " ' ach
tank at next pumpout. tf tanks have not been ou uithin the last three years, they should be pumpe
ou now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
Dy'SS�nfield inspection indicates:
11X Drainfield is dry, no surfacing evident.
12 Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City ]nspector
imnediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): ��//x p'^�'�
w/T
COMMENTS:
Date of Inspection ept c System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the prEmises uith the system loc=tion and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
CITY OF ORONO � O�
Municipal Offices O O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON–SITE SEWAGE TREATMENT
„� �, INSPECTION REPORT
ti
��9kESHo��G
Owner• � /%K.13��1'� �,l"n)� Address• Q ��') � �
Permit #'s: ��� Dates: -- "� [��� Contractors: �Y�'�
City ordi.nance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is J?�1 an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3):
1� "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and uhich is operating satisfactorily by treating and disposing of the entire current sewage input
uithout discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system uith less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic [ ] has or � has not been identified at this time. If the limiting soil
characteristic has not been identified, this c assification may be subject to revision.>
TANK CONDITION (5-10):
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
�j System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
��� Inspection risers missing-tanks could not be inspected. In ' - " i e must
tank at next . If tanks have not been pumpe out within the last three years t ey should be�mped
ou n
10 Inspec ion pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
Drainfield inspectior, indicates:
11 Drainfield is dry, no surfacing evident.
12 Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FAC70RS (slope,setbacks,etc.):
POTENTIAL POR SYSTEM FAILURE (depends on soils,Water table,etc.): ���,�.�.�
COMMENTS: t �,', �J `�
—� ���
Date of Inspection ptic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the pre�nises with the system loc�tion and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
On the North Shore of
Lakc Mi�znetonka
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT + POST OFFICE BOX 66
1335 S. Brown Rd.
� � � Crystal Bay, MN 55323
473-7357
OWNER /�,�r�t/in .�/'7i�f-� ADDRESS ���`� �n�,n7r�� �,�(%tj�
536c/ i�-�3-7� �-
PERMITNO.'S. ��'� DATES � -��' `� CONTRACTORS -��il���
City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is � an existing system ❑ new construction)
(Q( � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
��—~ properly.
� 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes.System appears to be functioning properly; no major
upgrading of the system is required at this time.
� 3 Does not meet current City standards in many respects relating to design,construction, or location.Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
� 4 System may or may not meet current City standards for design, construction or location, but is failing to property treat and
dispose of the current input, and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is
creating a safety hazard, or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( m Checked items may require your action)
Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not
❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks
❑ Solids accumulation i� tanks indicates they should be pump- have not been pumped out within the last three years, they
ed out this year to help prevent future problems. should be pumped out�ow.
❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates:
should be pumped out as soon as possible. � Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge, ❑ Drainfield is saturated and visibly discharging untreated
�� Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace-
Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days.
the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Future Expansion
❑ Soil table,and system condition) � Adequate
❑ High water table � Low � Fair
❑ Lot size ❑ Medium ❑ Poor
❑ Lake,wetland,or stream ❑ High ❑ Inadequate
❑ Drainage ❑System is causing visible
surface discharge.
' Y � �� � �r�.� /�r ��,���n�,
COMMENTS: � r��l%i�Uh i.C' I�� /,�1/� P / G+
f,aLL�ji I'� /)h�2 1/1�1�'✓:
�0��� /� �a
Date of Inspection ptic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer ot property,be advised that
this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available intormation.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/ Inspector's File GOLD COPY/Homeowner
SEPTIC SYSTEM INVENTORY �
Addr: 1940 Country Club Rd. PID : 27-118-23 42 0018
Building Type : residence # BRs/GPD: 3 # Systems/units : 1/1
Permit No : 5364 , Date of Permit : 10/13/78 Installer: E . J. Peterson
System Type : standard trench Appliances : lndry
SYSTEM CONDITION
Conformity: 3 Tank Condition: 9 DF condition: 11
Failure Pot : medium
SEPTIC TANKS
Material : concrete block Capacity: 1000 , 750
Setback to Bldg: 25
DRAINFIELD
Length of Lines : 400 No. Lines : 4 Trench Width: 3
Treatment Area : 1200 Type of Filter: rock
Tile Size : 4 Under Tile : 12 Perc Rate mn/in:
Setback DF-Bldg: 50 DF Ht above WT : 0
Soil Type : sandy clay Limitations : water table
WELL DATA
Setbacks - Well-Tanks : 75 Well-DF : 75
Report in File? : y Pump Type : subm.
Depth: 148 Diameter: 4 Method: drilled
INSPECTION RECORD PUMPOUT RECORD
Date Compliance Date Gallons
9/6/78 compliance-no surfacing s 11/9/81 1500
10/16/78 add 600 SF of DF and pump c 7/24/86 1500
8/9/79 no surfacing 1 8/27/92 1000
6/20/84 no surfacing 1
7/25/86 no surfacing 1
6/21/88 no surfacing; insp . pipe covered 1
10/8/90 no surfacing-need risers,pump tanks 1
7/27/92 no surfacing-need risers,pump tanks 1
9/19/94 no surfacing-need risers 1
10/18/95 non-conforming-repair by 12/31/97 3
��'`-� L.q I�.v►�ew T���-
__ -- -- - - - - 1
I
�- � �
�� �� �� o�U ��
1 ► �
� � I/� �-1 ��
� ��� �'� � I
���
�
�
I ?
��� v
_ _ _ _ I
� � _ _ __ - _ - �
� J
� �
f
�
�
I
� �
� Q
� � I
i
i �
I d ��
� �
(
i �
�
� �
c I �
� - - - - - �
( - - - - -
� I��
c' I .
�
�
� �� ���
Ol�� � �
Ol, f�� C��I � --�-
� � b, l� �-
, 9
� � �
�
� — -- —
�b�� M aJ'� � O��b�
�
G�`�
U�l�