Loading...
HomeMy WebLinkAboutseptic info �� �—��. �� a \ / ��\. � ��� ; ��;�� '`�� C 1T�' Of Uiial�O �,z: �� `� v►'� ,1�� r ' �'� . �%' Municipal Offices "� � ',�� ' � ._ , � ti;;,; ``. 'C� ii'`' � � .,:�� G. � Street Address: Mailing Address: ;� � � � �� �'�Y %/� P,O. Box 66 ���.�kES�I��i%' 2750 Keliey Parkway ���� Orono, MN 55356 Crystal Bay, MN 55323-0066 To: The Current Owner of Address � 7.�S �v%�/'���� �'� City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewa�e treatment system at the above address has been inspected and the following is known about the system. A sketch of tlle known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes �� No If yes, please contact the Onsite Systems Manager at 952-249-4626 within 10 days of receipt of this notice. The septic system must be broujht into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non-Compliant Yes � l�o If yes, system must be brouaht into compliance by: December 31, 2007 December 31, 2010 Other Septic Tank(s) Pump out Needed Yes �No The City recommends the septic tar�k(s) and/or lift tank be serviced and pumped out every three years. City xecords indicate the tank(s) were last pumped out on � _ � � —��� . The tanl:(s) should be cleaned through the manhole and not throu�h the inspection pipes, this allows for.proper cleanin�. Comments: ,r r. Ins ecto�� � � Date of Inspection ���� � P Telephone (9�2) Z�9-4600 • Fati (9�2)2�9-4616 _�-�� i��/ / O \��. /i � � i��:. O O ..,�.., �� CIT�' of ORONO , � ,' � �,,, � � '� ` Z� ���" �G, �% Municipal Offices ���� �� � '�' ��� ��,'� � Mailing Address: ` ` Street Address q 5a-a'�q'y 6 � t`9JfESKpg'� 2750 Kelley Parkway P.O. Box 66 - = Orono, MN 55356 Crystal Bay, MN 55323-0066 To Current Owner: Address: �� S� ���1�f f� v���" u r� City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): � 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the tluee foot separation requuement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is faIling for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil chazacteristics. TArrK corrDiTloN�s-��: 6 Tank inspection indicates: 5 Pumpout not needed at this time. ��eptic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped �'�S' C�-{ ) Mni:e sare septic t2�ks are uumped throu¢h manhole and not through white inspection pipes. This allows for the proper cleanin� Keep water softner and iron filter discharge out of septic svstem to prolonS iife of drainfield. Ask pumper to test alann float to verify alarm is still workin�in your house. The alarm warns owner that septa�e is about to backup into basement. 7 Inspection risers missing-tanks could not be inspected. Inspection risers�4"dia. pipe)mast be installed in each tank. If tanks-�.a�e-not bPen-pumped out within the last three years,they should be pumped out now. DRAINFIE�,D CONDITION(8-10): � _ _ _ 8 Drainfield is dry,no surfacing evident. 9 -Sbme evidence�fsurfacin�,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector imrfl�diat�l-y:Aepairs must be completed within 90 days. COMMENTS: 1`�c '„'^1 � pcj�S OK_ _ - ���r-� SE p1-;L �,�k� SQr�•^c� a.0�5- (�� � ���--5-�`� " '"�� Date of Inspection Matt Bolterman - Septic System Inspector Note: In the event that[his inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or ceRify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the available information. � o� o..�:., o �y���� CITY of �RONO , ���-=. .__,�- r� �1�.,� :.'t��. S+ . ��, ti `� �1� ��. ,,� ,�, hiunicipal Offices r �i�j-����. �� ��:��'��;,��hS'yG � Street Address: Mailing Address: �E$�I�4` 2150 Keliey Parkway P.O. Boz 66 Orano, MN 55356 Crystal Bay, MN 55323-0066 qsa-�49-4600 To Current Owner: Address: v� 7 5 S (e p a e� U�,c w �� City Ordinance 199 requires fhat each existin�on-site sewa�e treatment system in Orono be inspected every two years. The on-site sewa�e treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORI�SITY (1-3): � lb "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the eurrent Orono htunicipa!Cade. 2 "COMPLIANT SYSTEM" An iSTS which does not meet all the location,design and eonstrvction standards of the current Orono Municipal Code but does meet the thrce foot scparation requirement or two foot requirement for systcros instalted 1996 or eariier,and which is not failing or an immincnt threat to public health or safety. 3 "NON-CONIPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a desia ated 100-year flood plain,any ISTS which may or may not mect all thc location,dcsion,or conswction standards of t�e current Orono Municipal Code and which is failing for any reason;and any ISTS wich less than three fcet of unsaturated soil or sand bctween the distribution device and the limitino soil charactcristia. TANK CONDITION(5.7�: � Tank inspection indicates: 5 Pumpout not needed at this time. - 6O _Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. "` Tank was last pumped v�kM�w� �. - l�take sure septic tanks are numped throu�h-manhole and not throu�h white insaection pipes. This allows for the proner cleaninQ. 7 Inspection risers missing tanks could not be inspected. Inspec[ion risers(4"dia.pipe)must be installed in each tank. DRAINFIELD CONDITION(S3-�C1): � 8O Drainfield is dry,no surfacing evidenL - 9 Some evidence of surfacin„not critical yet. 10 Drainfield is saturated and visibly dischargin�untreated effluent to ti`�e surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. CO1��NTS: S y s K� �o�:�� C�. p�,�� �-G�\�� a�.�-, ��- �-��7 �a�� r�o� �Pcc� p � �-pe> w:�--_.� \�15� � �leA�S - � —�b '(�� �°�'-� Date of Inspection hiatt Bolterman— Sepdc System Inspector Note: In the event that this inspection report is used to satisfy the tequicements for a mortga;e or other ttansfer of propetry,be advised that this rcport does not guarantce or certify that an existing system will continue W function properly,but is mecely an opinion of the adequacy of the system undercurnnt conditioru based on the availabte information. -o� ��. � �\ O O`,; ,� , ;�... � � CITY of ORONO ti;j M���� o��� �� � � �� Street Address: Mailing Addross: ��. �,9 � �,� ii. $�gg0 � 2750 Kelley Parkway P.O. Box 66 �-_ ' Orono, MN 55356 Crystal Bay, MN 55323-0066 June 13, 2000 John & Maureen Vogt 2755 Copper View Drive Long Lake, Mn 55356 Dear Mr. & Mrs. Vogt: An inspection of your septic system was conducted on June 6, 2000. A summary of the inspection is below. Septic Tank Condition 1. Pumpout needed within one year. The septic system is a compliant system, meaning it meets all or most current City and State Standards. Enclosed is a list of licensed contractors who work in Orono on a regular basis. This list is enclosed simply for your reference in case your septic system needs maintenance in the future. Also enclosed is a fact sheet explaining your septic system and how it functions. Finally, an as-built drawing is enclosed showing the appro�mate location of the septic system. If you have any ques�ions regarding this report, please contact me at the City Offices at 249-4600. �spect lly, j,.� �;c t,uJ Chris Pence On-Site Systems Manager Enclosures In the event this inspection report is used to satisfy the requirements for a mortgage or othertransfer of property, be advised that this report does no guarantee or certify the existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with the system location and pumping records. Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us � � Companies, Inc. 13792 247�h Avenue—Zimmerman, MN 55398 Phone (763) 274-0925 Fa�c 1763) 274-0928 ROLL-OFFS � BLACK DIRT �' DEMOLITION SEPTIC SYSTEMS � EXCAVATING March 17, 2014 Mike Kurth SEPTIC COMPLIANCE 8726 Dupont Ave S Bloomington MN 55420 Project : 2755 Copper View Dr, Orono, MN A septic compliance was completed at the above address and the system is compliant according to the M.P.C.A codes for chapter 7080,and local codes for Orono in Hennepin County. The system has the following attributes: Date built: 1996 Bedrooms: 5 Septic tank: -1250 g,1000 g septic tanks Pump Tank: 1250 g pump tank, pump and alarm function Soil treatment: mound- soil separation is adequate Steinbrecher Companies, Inc. has been hired to perform a compliance inspection of your ISTS for compliance with local ordinances pursuant to Minn. Stat.§ 155.55 (2010�.The compliance inspection covers only the criteria required by Minn. Stat. § 155.55 Subd. 5a (2010) and Minn. R. 7080.1500 (2011).A compliance inspection is a snapshot in time of your septic system and does not warrant the condition or longevity of your septic system. Steinbrecher Companies, Inc. disclaims any use of the compliance inspection beyond determining ISTS compliance pursuant to Minn. Stat.§ 155.55 (2010). Sincerely, _-- �;1� �c�`������____ �--= Robert Polgreen Steinbrecher Companies, Inc � Minnesota Pollution Compliance Inspection Form - Control Agency 520 Lafayette Road North Existing Subsurface Sewage Treatment Systems St.Paul,MN 55155-4194 �$$T$� Doc Type:Compliance and Enlorcement Instructions: Inspection results based on Minnesota Pollution Control Agency(MPCA) For local tracking purposes: requirements and attached forms-additional local requirements may also apply. Submit completed form to Local Unit of Government(LUG)and system owner within 15 days System Status System status on date(mm/dd/yyyy): 3/17/14 � Compliant- Certificate of Compliance ❑ Noncompliant- Notice of Noncompliance (Valid for 3 years from report date, unless shorter time (See Upgrade Requirements on page 3) frame outlined in Local Ordinance.) Reason(s)for noncompliance (check all applicable) ❑ Impact on Public Health (Compliance Component #1)-Imminent threat to public health and safety ❑ Other Compliance Conditions (Compliance Component#3)-Imminent threat to public health and safety ❑ Tank Integrity (Compliance Component #2)-Failing to protect groundwafer ❑ Other Compliance Conditions (Compliance Component#3)-Failing to protect groundwafer ❑ Soil Separation (Compliance Component #4)-Failing to protect groundwater ❑ Operating permit/monitoring plan requirements (Compliance Component #5)-Noncompliant Property Information Parcel ID#or Sec/Twp/Range: 33-118-23-43-0019 Property address: 2755 Copper View Dr,Orono Reason for inspection: Owner's request Property owner: Buyer—Mike Kurth Owner's phone: 262-227-4304 Owner's representative: Representative phone: 320-334-9292 Local regulatory authority: City of Orono Regulatory authority phone: 952-249-4600 Brief system description: Two 1000 g septic tanks,to a 1000 g pump tank to a mound. Comments or recommendations Certification 1 hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of future system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate maintenance, or future water usage. Inspector name: Robert Polgreen Certification number: 9037 Business name: Steinbrecher Com anies License number: L2851 Inspector signature: `�'�_ � � i� ` y^-�^-�— Phone number: 763-274-0925 Necessary or Locally Required Attachments � Soil boring logs � System/As-built drawing ❑ Forms per local ordinance � Other information (list): cover www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 • Available in alternative formats wq-wwists4-31 • 1/24/12 Page 1 of 3 Property address: 2755 Copper View Dr, Orono Inspector initials/Date: RGP 3/17/14 1. Impact on Public Health-Compliance component#1 of 5 Co�liance criteria:_ _ Verification method(s): System discharge sewage to the ❑ Yes � No � Searched for surface outlet round surface. � Searched for seeping in yard/backup in home System discharge sewage to drain tile ❑ Yes � No ❑ Excessive ponding in soil system/D-boxes or surface waters. ❑ Homeowner testimony (see Comments/Explanation) ❑ "Black soil"above soil dispersal system System cause sewage backup into ❑ Yes � No dwelling or establishment. ❑ System requires"emergency"pumping — -- ❑ Performed dye test Any"yes"answer above indicates the system is ❑ Unable to verify (See Comments/Exp/anation) an Imminent Threat to Public Health and Safety. ❑ Other methods not listed (See Comments/Exp/anation) Comments/Explanation: 2. Tank Integrity-Compliance component#2 of 5 Com liance criteria: Verification method(s): System consists of a seepage pit, ❑ Yes � No ❑ Probed tank(s)bottom cesspool, drywell, or leaching pit. � Examined construction records Seepage pits meeting 7080.2550 may be ❑ Examined Tank Integrity Form (Artach) com liant it allowed in local ordinance. ❑ Observed liquid level below operating depth Sewage tank(s) leak below their ❑ Yes � No desi ned o eratin de th. ❑ Examined empty(pumped)tanks(s) If yes, which sewage tank(s) leaks: ❑ Probed outside tank(s)for"black soil" Any "yes"answer above indicates the ❑ Unable to verify (See Comments/Exp/anation) sysfem is Failing to Protect Groundwater. � Other methods not listed (See Comments/Explanation) Comments/Explanation: baffles in place, effluent levels good, Pump and alarm function. 3. Other Compliance Conditions-Compliance component#3 of 5 a. Maintenance hole covers are damaged,cracked, unsecured,or appear to structurally unsound. ❑Yes* � No ❑unknown b. Other issues (electrical hazards,erc.)to immediately and adversely impact public health or safety. ❑Yes* � No ❑ Unknown `System is an imminent threat to public health and safety Explain: c. System is non-protective of ground water for other conditions as determined by inspector ❑Yes' �No 'System is failing to protect groundwater Explain: www.pca.state.inn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 • Available in atternative formats wq-wwists4-31 • 1/24/11 Page 2 of 3 Property address: 2755 Copper View Dr, Orono Inspector initials/Date: RGP 3/17/14 4. Soil Separation-Compliance component#4 of 5 1996 ❑ Unknown Verification method(s): Shoreland/Wellhead protection/Food Beverage �odging? ❑ Yes � No Soil observation does not expire. Previous soil observations by two independent parties are sufficient, Com lianCe Criteria: unless site conditions have been altered or local requirements differ. For systems built prior to April 1, 1996, and ❑ Yes ❑ No not located in Shoreland or Wellhead � Conducted soil observation(s) (Atracn boring/ogs) Protection Area or not serving a food, ❑ Two previous verifications(Attach boring logs) beverage or lodging establishment: ❑ Not appliCdble (Ho/ding tank(s),no drainfieldJ Drainfield has at least a two-foot vertical ❑ Unable to verify (See Comments/Exp�anation) separation distance from periodically saturated soil or bedrock. ❑ Other(See Comments/Explanation) Non-performance systems built April 1, � Yes ❑ No Comments/Explanation: 1996, or/ater or for non-performance systems/ocated in Shoreland or Wellhead Protection Areas or serving a food, beverage, or lodging establishment: Drainfield has a three-foot vertical separation distance from periodically saturated soil or bedrock.' "ExperimentaP; "Other", or 'Performance" ❑ Yes ❑ No IndiCate de ths of elevations systems built under pre-2008 Rules; Type IV or V sysiems built under 2008 Rules (7080. A. Bottom of distribution media 95.1' 2350 or 7080.2400 (Advanced Inspector LiCense required) B. Periodicall saturated soil/bedrock 92.0' Drainfield meets the designed vertical C. S stem se aration 3.1' separation distance from periodically saturated soil or bedrock. D. Re uired com liance se aration' 3' Any "no"answer above indicates the system is •May be reduced up to 15 percent if allowed by Local Failin�to Protecf Groundwater. Ordinance. 5. Operating Permit and Nitrogen BMP*-Compliance component#5 of 5� Not applicable Is the system operated under an Operating Permit? ❑ Yes ❑ No If"yes",A below is required Is the system required to employ a Nitrogen BMP? ❑ Yes ❑ No If"yes", B below is required BMP=Best Management Practice(s)specified in the system design If the answer to both quesfions is "no'; this section does not need to be completed. Com liance criteria a. Operating Permit number: ❑ Yes ❑ No Have the O eratin Permit re uirements been met? b. Is the required nitrogen BMP in place and properly functionin ? ❑ Yes ❑ No Any "no"answer indicafes Noncompliance. Upgrade Requirements (Minn. Stat. § 715.55)An imminent threat to public health and sa/ety(ITPHS)must be upgraded, replaced,or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance. If the system is failing to protect ground water, the system must be upgraded, replaced, or its use discontinued within the time required by local ordinance. If an existing system is not failing as defined in law, and has at least two feet ol design soil separation, then the system need not be upgraded,repaired,rep/aced, or its use discontinued, notwithstanding any/oca/ordinance that is more stricf. This provision does not apply to systems in shoreland areas, Wellhead Protection Areas,or those used in connection with food,beverage,and lodging establishments as defined in/aw. www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 • Available in alternative formats wq-wwists4-31 • 1/24/12 Page 3 of 3 Soil Boring Data 2�123 Verdin Boring 1 Elevation: Location: Drain Field Soil Horizons Depth (uiches) Texture Color Structure 0-0.5' cla loam top soil 10yr 3/4 massive 0.5-2.2' cla loam top soil 7 0 r 5�6 massive 2.2' redox found Boring 2 Elevation: Location: Soil Horizons De th (inches) fI�exture Color Structure 1 - Boring 3 Elevation: Location: Soil Horizons Depth (inches) Texture Color Structure Boring 4 Elevation: Location: Soil Horizons De th (inches) Texture Color Structure 2755 Copper View Dr _ Elevations: , deep well bench mark= 100' . � 125' closest tank mound top=96.6' 165' mound media bottom=95.1' SB1 grade=94.2' S61 redox= 92.2' 5 BR house bench mark SE deck ftng � 2- 1250 g, 1000 g septic tanks 1250 g pump � • � . . � / � � • � SB1 � � �. � / � � • � , . � � • ` �� / � 1 � � / . � • � . ❑ • ` • • / mound, 2' lift N ' • . . , , ' � � .-- � • , . _ �7�.� � �er� � �� � � � � � A . � � ��� �� � �- � \� � -� �� 5a_'3 �{�� \ �� ' �' � �1 � (� � � ��� 6o'a T� o � , , � � f �' �� 4r�, \� �h ,�a'� �Qo U �� �, � /�� �I1 D IG�'� s��� � �� \ � O� , O ;�,a_ O � y r I C ITY of ORONO s � �� � �����r�� ��� � ���' l �, ' �, Municipal Oftices , 2 � �� �������i�� .,��� G� ,� ����� � ��"��� Street Address: Mailing Address: '9IfE$'��,�'Qg' 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: .�[J � � Address:2755 Copper View Dr. Permit #'s:8390 Dates:9/18/96 Contractors:Bauer Trucking (This is [ ] an existing system � new construction) YSTEM COMPLIANCE 1-3 : 1 1 Code Svstem: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant Svstem: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant Svstem: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level . (The saturated soil level � has or [ ) has not been identified at this time. If the saturated soil level has not been identified, this classification is subject to revision. ) TANK CONDITION 5-9 : 5 5 Pumpout not needed at this time Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers installed now. 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout the tanks � were or [ ] were not confirmed to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be watertight, this classification is subject to revision.) DRAINFIELD CONDITION (11-14) : 11 1 Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (svstem aqe and condition, soils, etc. ) : low COMMENTS: ��a� �� -����. Date of Inspection Sep ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 � FAX 473-0510