HomeMy WebLinkAbout2005-P08564 - mechanical � � PERMIT
CITY OF ORONO Permit ►vumber:
2750 Keiley Parkway - PO Box 66 P08564
Crystal Bay, Minnesota 55323 Per'mit Type: Mechanical Pernuts
(952) 249-4600 Date Issued: a�a�2oos
SITE ADDRESS: 754 Boulder Dr
I,ong Lake,MN 55356
PID: 33-118-23-11-0014
DESCRI PTION:
Proposed Use: Residential
Permit Class: General
Permit Type: Mecbanical Permits Permit Sub-type(s): Multiple Mechanical Items
DETAILS:
Approved per resolution#:
Separate permits required:
NOTICES/REMARKS:
FEE SUMMARY: Permit Fee: $ 101.25 Valuation: $ 8,100.00
State Surcharge Fee: $ 4.05
TOTAL FEE: $ 105.30
APPLICANT: Plymouth Plumbing&Heating OWNER: Dahlstrom Development LLC
12270 43rd Street NE 7745 Polaris Lane
St. Micheal,MN 55376 Maple Grove,MN 55311
THE UNDERSIGNED HEREBY REQUESTS PERMISSION TO MAKE THE REAL IMPROVEMENTS SPECIFIED
AND AGREES TO DO ALL WORK IN STRICT COMPLIANCE WITH ALL CITY OF ORONO ORDINANCES AND STATE OF
MINNESOTA BUILDING CODE REQUIREMENTS.
;
',� ��.�
APPUCANT PERMITEE SIGNATURE [SSUED BY SIGNATURE
Copies: 1-File(SiQnitures Required). 1-Applicant, 1-Monthlv Reports, 1-Assessin�, 1-Finance Page 1
. �
f '
CITY OF ORONO APPLICATION FOR MECHANICAL PERMIT
Box 66 (2750 Kelley Parkway)
Crystal Bay, MN 55323 _
GENERAL INFORMATION
l. You may apply for mechanical permits by mail or in person at the Ciry offices. Applications will be
reviewed and a permit will be issued within 2 working days.
2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL
YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON
THE JOB SITE.
3. Mechanical Designs - Complete calculations, details and specifications are required for each heating,
ventilation, humidification-dehumidification, and air conditioning installation including heat loss/heat gain
calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model.
Data shall be presented on form provided. Identification of and specifications for water heating equipment
shall also be provided.
4. When any new construction or remcLeling is involved, a separate builciing permit must�e a'�tained.
5. All work must be done in accordance with the Uni:�orm Mechanical Code/State Building Code requirements.
6. All work must be inspected(rough-in and fmal). Call 249-4600. 24-hour notice required.
7. House Heating Test Record must be submitted before fmal.
Instructions Complete all items on this application. Compute the permit fee. Sign and date the certification.
INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 249-4600.
Please check one: �ew Addition Repair Replace
_�Residential Commercial
JOB SITE: � , . � Zip:
Owner's Name. - -�� - • Telephone Number:
_ Mailing Address: ;:. „ ,_- __ , ---- City: __ . :Zi� - _ , -
Contractor's Name:. ������L�MBlNG IN�. � Telephone Numbe��(..;�_ �'��.,�/cx:,
12270 43rd Street N.�.
Mailing Address:_ _' ,��.z►+��,1 �N�5376-�7�I' _ _ ity: �lp:_ . w,:;=��i
SYSTEM DESCRIPTION
HEATING SYSTEMS
Quantity: �
Make: ��iL11�`�-
Model: C�-�31�t��f�C�1 u�
� Fuel: '
Flue Size: �
Input BTUs:` � t - —
Output BTUs:
CFM:
COOLING SYSTEMS
Quantity: �'7 �
Make: ��;2 v1.�.`�-
ModeL• � V�tC!�i) �I�`� �
- Tons: �
-- _—-- ------------ -_
H. Power r I 3
�
, ' �
FIREPLACES �� (��`^'�
� l
Gas factory fireplace /
Wood burning factory fireplace with flue
Wood Stove
Wood stove with flue
Brand Name Model No.
VENTILATION
No. � Kitchen E�aust � ducted recirculating cfm
No. �_ Bath E�aust (must be ducted outside) cfm
No. Other Fans: Locations ��
FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHAL)
Installation Removal
Fuel oil: gallons underground inside outside
LP Gas: gallons
Other Gas opening
PERt�1IT FEE CALCULATION
1. 1.25% of Contract Price* or Minimum Fee ($35.00)
L / �v�} - x .0125 $
(contract price)
2. State Surchar�e. ** Add the State Building.Code,Division
Surcharge to each permit. ` x .0005 $
or $.50, whichever is greater (contract price)
.. ' . � �>....• •�yY[L1I[K<N�1��� .
3. Postage and Handlin� (Only mail-in applications) $ 1.50
4. TOTAL PERMIT FEE (Add lines 1-3 above) $
* CONTRACT PRICE or JOB COST means the actual or estunated dollar amount charged for the permitted
� work including materials,labor,profit, and other fixed costs. It is the amount to be charged to the customer
for the work done. If any material, equipment; labor, or u�stallation are fumished by the owner, tenant or
any other party the reasonable market value of such items must be added to the estimated cost or contract
price for permit fee purposes. In the event that there is a dispute on the amount of the job cost,the City may
request the submission of a signed copy of the actual contract.
** The STATE SURCHARGE is .0005 of the contract price under$1,000,000 or $.50 -whichever is greater.
For valuations over $1,000,000 call the Department of Inspectional Services for the price.
� The undersigned hereby applies to the City for issuance of a Mechanical Pernut, agrees to do all
work in strict accordance with the ordinances of the Ciry and the regulations of the Miruiesota
` ' State`Building Eode; and-certifies that all statements made on this application are complete, true
. . � . .y�;.._- .
and correct. _ _
�
Applicant's Signature: . , � Date: � o�c' .S l`-
Approved By: Date:
� �i2HVi�C�Residential 8 Light Commercial HVAC Loads -,, Elite Software Development,Inc.'',
!, PlGrrzouth Plumbing&Heating '' John Terrance Homes- I
j B�ooklyn Center, MN 55428-1662 � rage 1
--- ___._ _
_ _
' Total Building Summary Loads 'I
Component Area Sen Lat Sen Total � !
' Description Quan Loss Gain Gain Gain ' �
3D Window Double Pane Low Emit Wood Frame 199 5,891 0 3,582 3,582 '
11 C Door Metal Polystyrene Core 42 1,619 0 367 367 �'
121 Wall R-19 + 1/2"Asphlt Board(R-1.3) 2216 9,995 0 2,266 2,266
15G Wall 5'or More Below Grade 8/12" BIk+R-11 739 2,605 0 0 0 I
161 Ceiling R-44 Insulation 1901 3,585 0 1,705 1,705 ��,
21A Basemt Floor 2' or More Below Grade 1896 3,731 0 0 0 ''
Subtotals for structure: 27,426 0 7,920 7,920
People: 6 1,380 1,800 3,180
Equipment: 300 1,200 1,500
Lighting: 0 0 0
Ducfinrork: 6,567 0 0 0
Infiltration: Winter CFM: 161, Summer CFM: 215 14,123 4,531 3,445 7,976
Ventilation: Winter CFM: 90, Summer CFM: 90 7,876 1,895 1,441 3,336 I
Sensible Gain Total: 15,806
Temperature Swing Multiplier: X 1.15
Total Building Load Totals: 55,992 8,106 18,177 26,283
' Check Figures _ ' ' , ,�
__ - -- - - -
Total Building Supply CFM: 902 (1.7 AC/hr) CFM Per Square ft.: 0.237
Square ft. of Room Area: 3,797 Square ft. Per Ton: 1,293
- _.. _ _�..__- _ __
�Buildi�g Loads_ _ _ _._ �
---- - ---. _.......
Total Heating Required With Outside Air: 55,992 Btuh 55.992 MBH
Total Sensible Gain: 18,177 Btuh 69 %
Total Latent Gain: 8,106 Btuh 31 %
Total Cooling Required With Outside Air: 26,283 Btuh 2.19 Tons (Based On Sensible + Latent)
2.94 Tons (Based On 77% Sensible Capacity)
Notes----
_ --- _ _
---
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads. I
C:\Elite\Rhvacw\Projects\John Terrance Homes-2460 Sandstone Ln -Orono.rhv Thursday, January 15, 2004, 3:23 PM