Loading...
HomeMy WebLinkAboutseptic info On t.he North Shore of Lake Mi�anetorzka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 � . � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER .�+^nTl �7P�h ADDRESS ��/-'S� � ✓i�t/nP ,C.Ji'; PERMIT NO.'S. ���� DATES 3���� CONTRACTORS 1 �✓r'`y � City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is � an existing system ❑ new construction) �y � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating �Gy properly. � 2 Does not meet all current City standards for new construction (1978 Code1 but in most respects appears to be designed, located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major upgrading of the system is required at this time. ❑ 3 Does not meet current City standards in many respects relating to design, construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design,construction or location, but is failing to properly treat and dispose of the current input,and is endangering a water supply,or is a source of pollution to surface or groundwaters,or is creating a safety hazard,or is otherwise creating a public nuisance.P�ease contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle.(Does not � Pumpout not needed at this time. give accurate measurement of solids accumulation.) If ta�ks ❑ Solids accumulation i� tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. � Orainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge, ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace- Inspection risers (4" dia. pipel must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) � Adequate ❑ High water table � Low ❑ Fair ❑ �ot size ❑ Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High . ❑ Inadequate ❑ Drainage ❑ System is causing visible surface discharge. COMMENTS: ��4`�� Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existi�g system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspectar's File GOLD COPY/Homeowner // � O� \\ \ O , O�� � I CITY of ORON� � �r �1 � I1 i „ �* ' 1� j �\� '^��i ,�, �t .� ' .��� Municipal Offices �' � '���}� �`,���'t����` G~'%� Street Address: q�a-a4q,y6o O Mailing Address \�'t�kE$H�¢�'��/ 2750 Kelley Parkway P.O. Box 66 ���---=' Orono, MN 55356 Crystal Bay, MN 55323-0066 To Cui-rent Owner: Address: � � � � ��` �� � ����e' �Ir . City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewa�e treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMITY (1-3): � 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. 2 "CONIPLIANT SYSTEM" An ISTS which does no[meet all the loca[ion,design and construction standards of the current Orono Municipal Code but does meet the three foot sepazation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soi]characteristics. TANK CONDITION(5-7): � Tank inspection indicates: � Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped /�;�i� •' V � ). Malce sure septic tanks are pumped throuQh manhoie and not throu�h white inspection pipes. This allows for the proper cleanina. I�eep water softner and iron filter dischar�e out of septic svstem to prolona life of drainfield. Ask numper to test alarm float to verify alarm is still workino in vour house. The alarm warns owner that septaae is about to backup into basement. 7 Inspection risers missin�tanks could not be inspected. Inspection risers(4" dia.pipe)must be installed in each tank. If tanlcs have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION(8-10): � 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging tmtreated effluent to the surface. Contact the City Inspector immediately.Repairs must be completed within 90 days. �'OMMENTS: )�<.r' d�..� � � � �� � .� ".? _ � _� � ' ��� �'C '� Date of Inspection Septic S�stem Inspector ;- � °� !o ,,, o ��=������ -� � CITY of ORONO I'I ����'j��:�,` � �i � ,� ,� .�. , r�, ,��.�;` ���:�.^ �,�I Municipal Offices � � � "�' I� � .t9' '���7lay�`�4��� Street Address: Mailing Addreu: $E+gg0 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323•0066 �. To Current Owner: Address: 3 5 7� C�` �' S�,ne �f . City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two�ears. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. YSTEM CONFORMITY 1-3 : � 1 "CODE SYSTEM" An ISTS which meets all[he location,design and construction standards of the current Orono Municipa]Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the curtent Orono Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or eaziier,and W hich is not failing or an imminent threat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within_a designated 100-yeaz flood plain,any ISTS nhich may or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failin�for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristi;s. TANK CONDITION(5-7): C� Tank inspection indicates: 5 Pumpout not needed at this time. 6O Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped 1 O-�-�—6 1 ). Make sure seatic tanks are pumped through manhole and not through white insnection pipes This allo�r�s for the proper cleaning. Keea water softner and iron filter discharge out of septic svstem. 7 Inspection risers missinb tanks could not be inspected. Inspection risers(4"dia. pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION(8-10): � � Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. COMMENTS: ►-ro�n� � oo� O K , p�^^P S�P i-'L -1-�,�k S c�cXr S� r.�-,r-c� p�-1 � -� -03 �� Date of Inspection Matt Bolterman - Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report dces not guarantee or certify that an existing system will continue to function properly,but is merely an opinion ofthe adequacy of the system under current conditions based on the available information. Telephone(952)249-4600 • Fax(952)249-4616 www.ci.orono.mn.us � o� o �. o �`��-� CITY of ORONO �� � '������ �+ '�'�+�� ��, � �%'y ;�"� G�l�r � Municipal offices ���,�`� i�;4.� Street Address: MaiI1nQ Address: EggO 2150 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 Owner: M���qel Sh;�I�S Address: 3S�s �-���5�'��e �r' City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two yeazs. The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. SYSTEM CONFORMIT'Y (1-3): I lO ��CODE SYSTEM" An ISTS which meets all the localion,design and constcuction standards ofthe current Orono Municipal Code. 2 °COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and constniction standards of the cu�reirt Orono Municipal Code but does meet the three foot separaiion requirement,and which is not failing or an itntninent threat to public health or safety. 3 "NON-COMPLIANT SYST'EM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which tnay or may not meet all the location,design,or construction standards of the cucrecrt Orono Municipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. TANK CONDITION(5-10): � Tank inspection indicates: S Pumpout not needzd at this time. OTank must be pumped out this yeaz (city code requires tanks to be pumped out every 3 years. Tank was last pumped �/- 1�- Q 6 ). 7 Solids accumulation in tanks is at a critical a critical level. Tanks should be pumped out as soon as possible. g System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected Inspection risers(4"dia.pipe)must be installed in each tank at next pumpout Iftanlcs have not been pumped out within the last Uuee years,they should be pumped out now. 10 Inspeclion pipe is located d'uectly over tank baffle(does not give accurate measuremerrt of solids accumulation). fftanks have not been pumped out within the last three years,they should be pumped out now. DRAINFIELD CONDITION(11-14): I � 11 Drainfield is dry,no surfacing evident. 12 Some evidence of surfacing,not critical yet . 13 Drainfield is saturated and visibly discharging untreated e8luent to the sutface. Contact the City Inspector immediately.Repairs must be completed withirt 90 days. 14 Drainfield e�ctent and condition unknown. CONIlVIENTS: SYSfic�-. ;5 oK_ P��,p tqnkS �-as- o i �� Date of Inspeclion Septic System Inspector � Note: In the event that this inspection repoR is used to satisfy the requirements for a mortgage ot other traatfer of property,be advised that this report does not guazantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under cuaecR conditions based on the availabie info�nation. CITY OF ORONO � O� M�nicipal Offices O O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT h INSPECTION REPORT �' G~ �9kESH�4'� Owner:GZ1'C��E� �G� iE�C��S Address: �"J�7S �i' 1Y (S�Ir�JE �2 , C5S,3S�� Permit #'s: �5�� Dates:_ � ` 2�- ��Contractora: , �(� :5 �=x� � � City ordinance rnmber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is y4�an existing system [ ) neu construction) ! � STEM CONFORMITY 1-3 : t "COOE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface Waters. 2 "COf1FORMING SYSTEM"-A system which does not meet all the tocation, design, and construction standards of the current City Codes, but was instalted according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located Within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system uith less than 3 feet of unsaturated soit or sand bet►+een the distribution device and the limiting soil characteristics. (The limiting soil characteristic ( � has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): -��- nk 'nspection indicates: Punpout not needed at this time. 6 Solids accumulation in tanks indicates they should be punped out this year to help prevent future problems. 7 Sotids accunulation in tanks is at a critical level. 'fanks should be pianped out as soon as possible. 8 System is discharging to the surface. Tanks must be punped out Within 48 hours to eliminate surface dischar�e. 9 inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be instalted in each tank at next punpout. If tanks have not been punped out Within the last three years, they should be punped out nou. • 70 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation). If tanks have not been punped out uithin the tast three years, they should be p�x�ped out nou. DRAINFIELD CONOITION (11-14): � ainfield inspection indicates: 1 Drainfield is dry, no surfacing evident. 2 Sane evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector irtmediately. Repairs must be completed uithin 90 days. 14 Drainfield extent and condition unknoun. LIMITING SITE FACTORS (slope,setbacks.etc.): ' /�.{ � , � POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table etc ): �Q�J ' COMMENTS: �Gr.�C S� `�('Ldi, /V�� S�(✓j�i Cl�1v ct..� (v(S' —� • _ � _ � Date of Inspection Septi System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available tnformatton. This report must be kept on the premises with the system location and Fxmping records. WHITE COPY/lnspectors File YELLOW COPY/Homeowner CITY OF ORONO � O� Municipal Offices O � O Post Office Box 66 Crystal Bay, MN 55323-0066 � � ON–SITE SEWAGE TREATMENT �,, �C,, INSPECTION REPORT 'C�� G~ 9kESH�4'� !�� �, 1 �� �/ � -z----a-�' �✓ r Owner• /�lc:./V��1 � �71)e1 Addres s: � Y � Permit #'s: Dates:_ �'�(`� Contractors: 4�� �.X�, City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site seuage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is � an existing system [ ] new construction) SYSTEM CONFORM[TY 1-3 : 1 "CODE SYSTEM��-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input uithout discharging any pollutants into ground or surface uaters. 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the current City Codes, but uas installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input uithout discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located uithin a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic �has or [ ) has not been identified at this time. [f the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK COfdDITION (5-10): Tank inspection indicates: � Purtipout not needed at this time. Solids accumulation in tanks indicarPs rhe� should_�e Dumaed out this vPar to F1pinr�nravPllY fuTurP oroblems. �o i s�tion in tanks is at a critical l�an s s ouTabe pumped out as soon as possib— l–e�� 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next punpout. If tanks have not been pumped out within the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pixnped out uithin the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): D�field inspection indicates: _ j,. 1 Drainfie[d is dry, no surfacing evident. �� 2 Some evidence of surfacing, not critical yet. ` 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City [nspector immediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): � POTENTIAL FOR SYSTEM FAILURE Cdepends on soils.uater table,etc.): �.-jd� / / �,,, � C MMENTS: `�f f �" � � � � Da e of Inspection ep ic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the prE�nises with the system loc=tien and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO � O� Municipal Offices O � O Post Office eox 66 Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT r�`,, �C�, INSPECTION REPORT ti ��9kESH���G Owner: ///ll.qY�1�� �a/'fl�f��� Address: �/,� ��✓l�S YW. A 11; ` i Permit #'s: /1�`�1 Dates:____ �>��" ` Contractors: � �/P_� �C��. City ordi.nance number 100 requires that each o�-site sewage treatment system in Orono be inspected on a regular basis. 7he on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is �an existing system [ J new construction) SYSTEM CONFORMITY (1-3): J� "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM'�-A system uhich does not meet all the location, design, and construction standards of the current City Codes, but uas installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic � has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identi ied, this classification may be subject to revision.) TANK CONDIT[ON (5-10): Tank inspection indicates: 5 Pumpout not needed at this time. � Solids accurtwlation in tanks indicates they should be pumped out this year to help prevent future problems. �olids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out uithin the last three years, they should be pumped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pumped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): Dr�field inspection indicates: Drainfield is dry, no surfacing evident. 2 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector imnediately. Repairs must be completed within 90 days. 14 Drainfield extent and condition unknown. LIMITING SITE FACTORS (slope,setbacks,etc.): /��"' / POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): ��; COMMENTS: /. �._ Date of nspection ep c System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the pre�nises with the system loc�tion and pumping records. WHITE COPY/Inspectors File YELLOW COPY;Homeowner � �O� O � O CI'TY OF ORONO � � �" ,��� � MunicipalOffices r�,, ,�� �' �, Street Address Mailing Address: �t �j'�' 2750 Kelley Parkway P.O. Box 66 �i Orono, MN 55356 Crystal Bay, MN 55323-0066 �kESH�g' To: The Current Owner of Address 3575 CHRISTINE DR City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes �No If yes, please contact the Onsite Systems Manager at 954-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identified as Non-Compliant Yes No If yes, system must be brought into compliance by: December 31, 2007 December 31, 2010 Other Septic Tank(s) Pump Needed Yes No The city recommends the septic tank(s) and/or lift tank be serviced and p mped out every three (3) years. City records indicate the tank(s) were last pumped out on �- 3 ( - U� The tank(s) should be cleaned through the manhole and not through the inspection pipes, this allows for proper cleaning. Comments: w '���-'� � �.�� � - G� Inspect " ""'� °` -�,{ Date of Inspection: Telephone (952) 249-4600 • Fax (952) 249-4616 www.ci.orono.mn.us ! _ � • • • • � To: Orono residents on mound rype septic systerns From: Wifiie Gibbs, ISTS Manager Date: May 10, 2006 Re: Landscaping Do's and Don'ts for Mound Systems, Quick Reminder Do plant and maintain a ful! cover of grass and keep mowed to a normal height, this grass cover aids in the evaporation of large amounts of effluent (the fiquid left after the "othe�" stuff has been removed) in the summer time and allows the mound system to help breakdown nitrogen in the effluent, Do water the grass over the mound in extreme dry conditions, sparingly. Do avoid unnecessary foot traffic over the mound, mow it and stay off of it. This is especially true in the winter time. Even human foot traffic can cause frost to penetrate the mound resulting in potential freezing problems. Do inspect your mound system annualiy for winter kill, (reseed if necessary) animal damage, (burrowing)or signs of potential failure. Do not plant trees or shrubs on the mound system, smaller trees and shrubs may be planted at the edges. Remember,that sunshine is the key to a healthy mound system. Do ask questions, if you have any concerns or questions concerning your mound systern please feef free to call me, ! can be reached at 952-249-4626. 1 SP TESTING /NG Steven B.Schirmers —951 Katydid Lane NE—St. Michael,MN 55376 Cert. No 627 — State License#394 — Phone 763-�4973566 — Fax 763�97-5011 www.sptestinA.wastewater@comcast net— schirmerswastewater.com October 29, 2015 � Janeile Shields 3575 Christine Dr. Orono, MN A Compliance inspection was completed for the existing on-slte sewage treatment system located on this property. The system consists of 2-1000 gallon septic tanks, 7-1000 gaflon pumping chamber S a pressurized mound system with a 10' x 55' rock bed built in �1989 for a 4 bedroom home. Soit boring #1 found mottled soil {redox features} at 2.6' into the original soii. Soil boring #1 found the original soil at elev. 89.4 8 the bottom of the rock bed at elev, 99.4 leaving 2' of sand below the rock bed � a 4.6' separation from the bottom of the rock bed � redox features, Soii boting #2 found mottled soil at 1.7' into the o�iginal soil. Soil boring #2 found the original soil at elev. 89.5 & the bottom of the rock bed at elev. 91,4 leaving 1.9' of sand below the rock bed � a 3.g' separation from the bottom of the rock bed 8� redox features. This system is classif�ed as in complfance with Minnesota Chapter 7080 rules. The tanks were pumped � aertified by Kothrade Sewer Water � Excavating. Nothing other than gray water (laundry, showers etc.} human waste 8� toilet tissue should be disposed of into the septic tanks. Garbage disposals are not recommended due to adding more sol�ds & fine solids passing through into the system. Iron fiiters are also not recommended $ should be diverted out of the system. Excessive amounts of soaps, antibacteria! soaps, cleaning agents, shower cleaners used every shower 8 chlorine agents may kill the bacteria you need living In the system. Additives are not recommended. Recommend to pump & clean you tanks through the manhole by a certified pumper every 2 years. Check with your pumper to set up a schedule. This cerEi�cate of compliance is no guarantee that this system will continue to function ind�n[tely. Steven B. Schirmers , SP TESTING /NC. Steven B.Schirmers —951 Katydid Lane NE—St. Michael,MN 55375 Cert.No 627 — State License#394 — Phone 763-497-3566 — Fax 763-497-5011 www.sptestina.wastewaterCa�comcast.net— schirmerswastewater.com SOiL BORING PR4FILE Janelle Shields 3575 Christine Dr. Orono, Mn Soil borings completed with a bucket auger on 10-20-15 SOIL BORING #1 - ELEV.92.5- MOTTLED SDIL PRESENT AT 2.6' into #he ori8inal soil - NO STANDING WATER PRESENT IN THE BORING. 0 - 8" Fill soil S� - 37" Fill soil medium sand 37" - 44" Original soii very dark gray loam to clay loam 10VR 3/1 44" - 56" Very dark brown loam 'IOYR 3/7 56" - 68" Dark brown clay loam 10YR 4/2 S8" - 72" Brown clay loam 10YR 4/3 - distinct mottles 10YR fil8 SOIL BORING #2 - ELEV.93.1 - MOTTLED SOIL PRESENT AT 1.T' into the original soil - NO 8TANDING WATER PRESENT IN THE BORING. 0 - 12" Fill soil clay loam 12" - 40" Filf soil medium sand 40" - 48" Original soil very dark brown clay toam 10YR 3/9 48" - 60" Brown clay Ioam 10YR 4/3 60" - 70" Brown ciay Ioam 70YR 5/S - distinct mottles 10YR 56/8, 10YR 7/1 � S-P TESTING, /NC. � Ste�e� B. S�,i�� • MPCA Cert.No. g27 951 Katydid Lane NE • St. Michael� MN 5537g • (763}�4g7-356fi FAX (763) 497-5011 . State License #394 wwwsptesting.wastewater(a�comcas�,net- schirmerswastewater.com 1 � i�v�. , �.4.`�E��►s-fi�.1�_ �� , . V4�o�v r�� . }�tS l�? � 5 � , ��w�. Vi• _ ~ r � J" �M: 1 Oo,o 'Ta� ,o� '�qy�,,,� �1a1c . � .. ._... ►6 �(�II qd� Ouy� 38` . ��. �N ' . . . i� � 11 . �o�.ks �� ��� y � �-�v,l�-�C�o�. S � �'��L.-g�.S `"�°vo�;'O°:`�r a:l.' o�u. so,�.. s.► �434-y. �� '�.�ir1��r,�r . � ►oci . 'Q9ti�'4�c� q 1.�•1 L�IAVIs�� �.0�S�s-'�Q►sR - 1� ��L� ���Se�• ___.__ ��-a - 9 . ,;.� ,.�T � _ . o u.�,� .3► - .�..���._�.�.�.,�� o____.�2s��5��..5..r-�t_�-.�-��*�,.w►S+aw� �G11�.'1�3.�.5���4�191i_..--------.....__ Mo►�faa S�S�{�•aS �4 t� � �a � e� q3�`F 9 3��� � 4�ot� 1� q�� � � °�1•�k �a . ��y;z c�w�-�►i.`� d S _ • �j0� ;:,�.�:r� �I��hnesota Pollution COrT�I l�ance .inst�ection For � ��� Con�rot Agenty � t' m � 5�0 La�ayette Road North ��ti�g 5���� ��9e 7'reatment Systems s�.Paui,MN SSt55-4194 �SSTS) Doc Tvpe:CamWa►�e ar►a E►ilF�emerrt Instructlons: InspecEion resuMs based on Minnesota PoNuHon Controi Aaency{MPCA) Far locel tracking purposes: requirements and atta�forms-additianal loc�if requirem�ts may afso apply. Subm(t comp(et�ed tonn to Locat Unit of Oovemmertt(LUO)and syst�em owner within 15 days . System Status System status on date(mmlddfyyyy): /(J-a� -�s� �Compl�ant—Cerdflcate of Compltance ❑ Noncompiiant—Notice of Noncompliance {1/apd for 3 years firom report date,unless shorter tlme (Ses Upg�de Requlr�mertts an page 3) trame outlJned fn Loca/Oroflnance.} Reasan(s)tor nqncompliarfce{chsck all appllcab/e) �� ❑ Impact on Public Health{Complfance Componeni #i)-lmminer►t thrvat te publlc hea�h and safi�ty ❑Other Compll�oe Conditlons(Corr�llance Counponent#3)-lmminent tt+�at fo publk health and sefety ❑7ank 1nts8riiY(Complfance Component �2)-Falqng to protec..Y grtwr+dweter ❑Other Campliance Conditions(Corr�pllarrce Component�3)-Fa!ling to prt�fect qroundwafer � ❑Soll Separatlon{Complfar►c�Componarit #4)-Faflfi9 to Prr�tect groundwater ❑Operatln�permitlmonitoring plan requirements(Comp!lance Component #5)-Nor►complfant Property Ir�formation paro�ir�or ser�rwprr�an98: _��rf�u�,,�, �,c�• Properly addreas: _3 5 7 S Gl�'�,�C1�3-.��i�. ��c� Reason far inspec�ion: � �Q.,A��SF� Praperty ovmer: Owners phor�: or � Owne�'s representaHve: P'�J��'V' .�ii��i'aruC� Repres�tetive phone: ��,�Z �a lr���}014 t.ocei r�egulatory atrtt�ority: L�.'C� t9� d4�(9�Lc) Regufetory authortty phone: g S2-�aW9 - �Flov o Brief system descx9ption: ' � • Comments or reoommendations: Certff�cation 1 ha�by certity ihat al!the necessary Informadion has bser►gafhered fo determine the canmplfence sfatus of thls sysfsm,No determinadon of lufur�system performance has besn nor cen be made due to unkno�m conditlons dudng sys#em oonstrucilon, posstble.abuse of the system,Inedequste mafni+�nanve,or hdure w�ter ussge. Inspector name: ��y(l�.l +�.,���t!'Prh��DQ� Certiftc�tion number. f�,..a.7 BUsin8s8 n8m@: -' � UC@t188 RWfIbBT: -- -�e�-71.�- Inspedoc signature: ...- ,. �..�--- Phone number. �{d� --4.�-�-�, �� Necessary or locally Requ�red Attachments �Soil boring fogs �System/As-bu�t drawing (]Fo[ms per local or+dir�r�ce ❑Other{ritormatlon(iist): . www�pc�.state.mn.us • 451-29b-4300 • 8Q��657•3864 • Ti'Y 651•Z82-5332 or 80o-657-3864 • Avaitabte in aitematNe formats ►,�-�t�,-3r . rn4irz � Property eddre�s: 3��� �,►�1Q���.,►.�• tj.�,.r.�. p Q,d;�v .� Inspector inlUalalDate: ��,d-1 ''' 1. lmpact on Public Heaith-Compitance component#1 of 5 .. Com ifancs c�iterla: Variftcatlan m�thod(s): System discharge aewage tu the ❑Yes �No � ��r eurface ouUet round surface. � Searched for seeping in yardlbadcup ln home nlo System diacharge sawage to drain t�e ❑Yes �Na �I �zo�sive pondtng in so(I systam/0-boues 1.�4 or surtaoe waters. D Homeo�mer tesNmony($ee comment�EicpianaHon) System cause sgwage badcup lr�tc ❑Yes �No � ���S°��0�8011 dispersal system �.10 dwelfing or establishn�nt. ❑ System requlres"emergencyl'pumptng ❑ Performed dye test Any'•yes„anawer above/ndicai�s ths system is ❑ Unsbte to verify(See Coniment�i6rplansllon) an!mminenf Tftreat tia Publ(c Ne�tlth and Safety. 0 p��methods not fiated(see Comments�F rpla,reato„) Commentsf�xplaneUon: , . 2. Tank Integt"ity--Comp�iance component#2 of 5 � Coni liance crlterta: ,. Veriflcatiort method{s); . System oonslsts of a aee�a6e Pit, ❑Yes ❑No ❑ Probed t�nk(s)bottom �c�sPool.dryweil,o�leadiln9 P�. . ❑ E.xamined construcdon records See�e pRs mee�rtq T080.765o mey be ❑ Exatt�lcted Tartk I�agcity Fo�n(attach) c�mm lfsnt,�aUowed!n loca!a�lner�e. ❑ �bserved lEguid fe�rel below opera�ng depth Sewage tank(s)leak below thelr ❑Yes ❑No � �i�� u�t desi ned ratin de th. PiY(P i�t�nks(s) Ef yes.which sewage tarik(s)feaks: ❑ Probed outside tank(s}for`bladc soil' I1ny"yes"answerabove ina�catea the . . O U�le to veMy(see commer,ts�xp�enauon� aystem Is Falling to Protecf Groundwefer. . ❑Other methods not fisted(See comments�xplenatton) CommentsJExplanaSon: ' • S�i�/ 1�'�'��L1�,k� '�,Ckf�111�, 11.t�'���r,�`'� . '���'� -��`(�1��'�'�'bw'�� � 3. Other Comptlance Conditions—Compii�nce campanent#3 of 5 a. Mair�enanos hole oovecs are dart�ged�cxedced.un�mad,oc�tc�ra0y unso�nd. D Yes• �►ao I�un�oMm b. Other issues(elecbical hazerd�,eb.}b�h�eE�ly 8nd adveisely MpBd pubNC h�dlt oT Sa�etyl. �]Yes" ■No ❑Unia�own *System Is an Unminer�t th►est to pubJk haaffh and sal�ty ��; �i���C4-1 t.�. �fL¢�A�S� - . c. Systiem is nori�rotedi�re of ground waterfor o�her t�iats as de�emdned by t�pec�or ❑Yes" ■Mo 'Syale►n/a fi1IORg�0 p/vmCtQ�ulwd�t�F . Explafn: � Www�pc��state�ilul�us � 651•z9b�b300 � 800�651�3864 � � TTY b31•281•5332 Or�65�•3864 • Ava��abte�altemative farmats wq-wwlstsf-3i • 1/24/12 Prop�rty address: 3�'i s Ll-�nZ�L�.a.� '�,7�- � c�4-��.c� Inspector Wtiaals/Dale: ` /v�'ao-�� ' 4. Soit Separation—CompGance componer�t#4 of 5 Date af tnstallation: ! J q�a( ❑Unknvam VeriRca#lon method(s): lodytnrefandlwettt+ead pro�tfontFood Sevsrape �Yes ❑No SnJI obse�vation daes not axpJr�.Pnavtous soN obsenratfons by two lrtdepende�f partfes are sufl5cfent, Com Ilance ct�teria: unless slte c�ondr�ons heve�een aJtered or-bcaf For sysfems buJ/t pr�or to Ap�i!1, 1996,ar�d ❑Yes ❑Pla �j��a ditler. noflncatedln ShoreJand orWellhhesd � Conduc�ed soil obser�ation(s)(Attact,boring�ogs} Profecdion A�ea ornot serving a food, ❑ Two previous ve�ons{Attadr bor�n9�1 beverage orlodging est�Wtshment: Drainfleld has at ieast a twafoot vertEcxil � µOt applicable{Ho�ng tank(s},no�nt►efd} separation distance�rom pe�iodlcaily ❑ Uitable to verity(See Comment�xptanatkn) saturated soif or bedrock. ❑ Othe�(Ses c.anments/Explena�on) Nor�-perfom►ance aystems bullt Ap�i1 i, �Yes ❑NQ Comments/Explanatlon: 9998, or/aherorfiornon pe�mence systems locafed!rr Shae/and or Wephesd Pr+�tecUon A�as orssrving a fiood, beverege,orlodgingesfaWishmertt: . Drair�fleld has a thr8e-foot vettical separatton dtstance from pe�iodicai�r . saturafed soil or bedr+odc.` °Expedmental", `Othe�',or •Perfomrancaa' � ❑Yes ❑No lndicate de of elevadons systems built undsr p�s-2008 Rules;Type IV .. or V systems buNt under 20a8 Rules(7080. A. �ottom of dtsMbution media �'l+�'"d 9�•� 2350 or 7080.2400 (Advanced inspec;tor � s�� t � �•L. ��.o'sa.�� Lic�ense requir�d) B. Peri satu�abed soiVbedrodc s�rb�a- �, l-�'s+a�*�,� �rainfield meets the desEgnecf vertical C. tlon 5��`L- y.c,�� , separation distanoe frorn periodfc�lty ' saturated soil or bedrock. 0. ulred Ilance n� �'�/ Any"no"answer above fndlcatss the system!s� *May be reaucea up to 1�percent ff a�towea by�oca� Faliing fo Profect Groundwater. ordinance. 5. �perating Permit and Nitrogen BMP*—Complianoe«�mmponent#5 0#5 ■Not applkable . Is tbe system operated under an Opera�ng Pertnit7 ❑Yes ❑No !f"yes"�A b�low�requlred Is the system requlred to employ a Nitrogen 6MP?� O Yes ❑Na N"yes"�8 below is requfred BMP�Best Menag�merrt Pr�cb'ce(s)apec�if'ied br the sy,�m deslgn K the answer to both questlons ts"no;thts aecdon does nof need to be completeal � COtit I18RC@ C!'It@rIe a. Operaling Perm�number: ' Have the O eratl Permit uirements been met? ❑Yes ❑tVo b. Is the uired en BMP in (aoe and ro furx�Ionin � Yes No Any"no"answerina�cates Noncomptfance. Upgrade Requframertts{Mlnn.Stet§1�5.68)M lmmhreM threetb pubRel�alth and aefe(y(ITP.HS)»nist De uP9rgded,�eplaced,orlts use �scb�nued w�bt ten mortfhs of recelpf�this nntics or w�thb�a shorter perlod lf reyWr+ed bY Mcel av�nance.lf the aystem!s fapin8 to proted �nrouund wafer,the system rnust be upgradeQ replececf,ar Ks use dieoondnu�d wldrhr the thne requlr�d by bca!ordinanae.!f an exlsth�g system is��nr,��s�nee�,tsw,andne$8��east rwo r�erad�►,scn�e�uon,rnen r�aysrem�d nac be u�►aaed,re�rred r�►8�ea,or ns use�ued,�vl�andh�9 a►�Y!xa!ordh►a►�e thatls more sbh.�Thls pr�visJa►does not e�ply to aystems fi shore/snd areas, Wellhead Profedfon A►+9es,ar those used in connect�on wlth fbod.beaera�B,end fodg�fi�g establ�hments as deffned&�law. www,pCB,St��e,mn,uS • 65l•29fr6�0 � 800-b5/-3864 • 1TY 651-28't•5332 or 800�b57•38b�4 • Avail�h�e�t attemative formatr ,�-wwtsc�r-3 r • f/24/J2 � . 3575 Christine Dr,Orono MN 55358 Property address: Michael�Janelle Shields Inspector initiatslDate: LB 10/22/2015 1. Impact ott Public Health—Compliance component#1 of 5 Com Elance criteria: Verifcatlon method(s): System discharge sewage to the ❑Yes ❑No ❑ Searched for surface aatlet round surface. ❑ Searched for seeping ln yard/badcup in home System discharge sewage to drain Gle ❑Yes ❑ No ❑ �sslve ponding 1n soil system/D-boxes or surface waters. ❑ Homeowner testimony(Sss Commems/Explanatlon) [] "Bladc soil°above soii dispersal system System cause sewage backup into ❑Yes ❑ No � gy,tem requires"emergency'pumping dwelling or establishment. ❑ Performed dye test Any"yes"answer above indfcates fhe system Is ❑ Unable to vertfy{see Comments/Explanetior►) an/mminent 7"hreat to Pub!!c Healfh and Safety. ❑ Other methods not listed(see Comments�cpranation) Comments/E�lanation: 2. Tank tntegrity—Compliance component#2 of 5 Com liance ctiteria: Verffication method(s): Sysiem consists of a seepage pit, ❑Yes�o ❑ Prabed tank(s)bottom cesspool,drywell,or leaching pit. ❑ Examined construction records Seepsqe�its meeting 7080.2550 may be ❑ Examined Tank Integrity Form(Attach) oom lant if allowed Tn loce!ordlnartce. ❑ �bserved liquid leve!below operating depth Sewage tank(s)lesk below their ❑Yes No desf ned o ratin de th. � Examined empty(pumpedy fanks(s) if yes,which sewage tanfc{s}leaks: ❑ Probed outside tank(s)for"black soi!" Any"yss"answer above fndfcates the ❑ Unable to verify{See Comments/Explanation) system Is Falling to Protect Groundwater. ❑��►er methods not listed(Sea CommentsiExplanetion) Comments/Euplanation: �—�e�p 9�.6le,., �c,.,,� 5 n� �o o d C'o,.�d;�o,J Business Name: Kothrade Sewer,Water,Excavafing, Inc Business Addr�ess: 12059 Whitetail Ln, Hanover MN 55341 � Business Phone: 763.498.8702 Company Representative: Larry Bursch MPCA#: 0192/9t99 Signat � 3. Other Comp(iance Conditions—Compliance component#3 of 5 a. Maintenanve hofe covers are damaged,cracked,unsea�red,or appear to struduralty unsound. p Yes` p No p Unknown b. Other issues(elechicslhazards,eic.)to immediately and adversely impad pubfic heafth or sa#ety. Q Yes• ❑No O Untcnown 'System Js an/mminenf thne�at to pubiic heaith and safety Explain: c. System is non-protective of ground water for other conditions as determined by inspector p Yes• p No •System is failing to protect groundwater www.pca.state.mn.us • 65t496-6300 • 800-657-38b4 • T7Y 651•282•5332 or 800•b57-3864 . Avaflable in attemative fortnats wq-wwists4•3f . !/24/f2 Poge 2 of 4