Loading...
HomeMy WebLinkAboutseptic info On the North Shore of Lake Minnetoyzka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 � _ � � 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER /�V� G• 1�✓�►��'�tJ ADDRESS ���D ����,�.q l.Yl� PERMITNO.'S. DATES J�/��� CONTRACTORS City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is �an existing system ❑ new construction) �� Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating properly. � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major upgradi�g of the system is required at this time. � 3 Does not meet current City standards in many respects relating to design, construction, or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and dispose of the current input,and is endangeri�g a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard, or is otherwise creating a public nuisance.P�ease contact the City Inspector to discuss system repairl replacement procedures. If drainfield replacement is necessary, soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directfy over tank baffle.(Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks �Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems, should be pumped out now. ❑ Solids accumulation in tanks is at a critical level. Tanks Drainfield inspection indicates: should be pumped out as soon as possible. � Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated ❑ Inspection risers missing—tanks could not be inspected. etfluent to the surface. This condition may require replace- Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table,and system condition) ❑ Adequate ❑ High water table �,Low �Fair ❑ Lot size ❑ Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High . ❑ Inadequate ❑ Drainage ❑System is causing visible surface discharge. COMMENTS: ��/.� 90 Date of Inspection eptic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY /Homeowner On the North Shore of Lake Minnetoyzka ON-SITE SEWAGE TREATMENT INSPECTION REPORT � POST OFFICE BOX 66 1335 S. Brown Rd. � � � Crystal Bay, MN 55323 473-7357 OWNER �—"� � ADDRESS PERMIT NO.'S. _�C�� DATES ��I ��gb CONTRACTORS • � City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is �-an existing system ❑ new construction) y� � Meets or exceeds current City standards in all respects relating to design,construction,a�d location.Appears to be operating �� properly. � 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes.System appears to be functioning properly; no major upgrading of the system is required at this time. ❑ 3 Does not meet current City standards in many respects relati�g to design,construction,or location.Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. � 4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and dispose of the current input,and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is creating a safety hazard, or is otherwise creating a public nuisance.Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfield replacement is necessary,soil testing will usually be required,and a design and site plan must be submitted for review.Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( m Checked items may require your action) Tank inspection indicates: ❑ Inspection pipe is located directly over tank baffle. (Does not ❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks ❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they ed out this year to help prevent future problems. should be pumped out now. ❑ Solids accumulation in tanks is at a critical level, Tanks Drainfield inspection indicates: should be pumped out as soon as possible. `�Drainfield is dry,no surfacing evident. ❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet. within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated � �Ins ction risers m' ' — nk d not be inspected. effluent to the surface. This condition may require replace- ,Jl Inspection risers (4" dia. pipe)must be installe in eac tank ment or additions to drainfield. Contact the City Inspector at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days. the last three years,they shou pumpe out now. ❑ Drainfield extent and condition unknown. SITE CHARACTERISTICS: Limiting Site Factors Potential for System Failure Site Capabilities for ❑ Slope (depends on soil types,water Future Expansion ❑ Soil table and system condition) ❑ Adequate ❑ High water table �Low '� Fair ❑ Lot size ❑ Medium ❑ Poor ❑ Lake,wetland,or stream ❑ High ❑ Inadequate ❑ Drainage ❑ System is causing visible s rfac discharge. I COMMENTS: ✓e � e �s �� � d � -��/ Date of Inspectio� Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions based on the available informatio�. This report must be kept on the premises with system location and pumping records. WHITE COPY/Inspector's File GOLD COPY/Homeowner � % ,/� �11�' /%�O O�,�, 'i,i ,� ��,�����r:������:�.. �, ��� CITY of ORONO V� a$, � • �, � �ti� Municipal Offices � , ,� �. � � �i'� � t�;C'v�� G � �,� .� Street Address: Mailing Address: `qk'EggO�' 2750 Kelley Parkway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 owner: p' '\ _ �f � ��t/ Address:4360 Chippewa Ln. Permit #' s:8793 Dates :ll/17/86 Contractors:Widmer Bros. (This is [,�J an existing system [ ] new construction) SYSTEM COMPLIANCE (1-3) : 1 � Code Svstem: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Compliant Svstem: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non-Compliant Svstem: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level . (The saturated soil level [X] has or [ ] has not been identified at this time. If the saturated soil level has not been identified, this classification is subject to revision. ) TANK CONDITION (5-9) : 8 5 Pumpout not needed at this time 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. � Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out within three years, they should be pumped out and risers instal�ed now 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now. (During the last septic tank Maintenance Pumpout the tanks [ ] were or [� were not confirmed to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be watertight, this classification is subject to revision. ) D INFIELD CONDITION 11-14 : 11 11- Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition unknown. POTENTIAL FOR SYSTEM FAILURE: (svstem aqe and condition, soils, etc. ) : low COMMENTS: ���'/l-�'� - �� -��'�---- � Date of Inspection S tic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Telephone (612) 473-7357 • FAX 473-0510 CITY OF ORONO � O� Municipal Offices O � O Post Office Box 66 Crystal eay, MN 55323-0066 a � ON—SITE SEWAGE TREATMENT r�`,, �G�, INSPECTION REPORT ti ���kESH04�G Owner: L.� � Address: `��C)� ( `{�j/`f�u,;,�)!� �, Permit #'s: ° Dates: ����C��` Contractors: /Jt/iC.f/�F� �(�., City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is [� an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): � 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM'�-A system uhich does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic {�has or [ ] has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): Tank inspection iruiicates: 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 [nspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout✓ If tanks have not been pumpe ou wt tn e"���years, they shoul3�e-�SOmp'�Zt ou now:'� 10 ]nspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been purtiped out within the last three years, they should be pumped out now. DRAINFIELD CONDITION (11-14): � Dr field inspection indicates: �Drainfield is dry, no surfacing evident. 12 Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City ]nspector imnediately. Repairs must be completed uithin 90 days. 14 Drainfield extent and condition unknown. L[MITING SITE FACTORS (slope,setbacks,etc.): POTEN7IAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): �`^J COMMENTS: a �= �- 1.. Date of Inspection S ptic System Inspector Note: !n the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system w�ll continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the prE�nises uith the system loc�tien and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner CITY OF ORONO � O� Municipal Offices O � O Post Office Box bb Crystal Bay, MN 55323-0066 a � ON—SITE SEWAGE TREATMENT v,y`, � 2NSPECTION REPORT 'C�� G~ � �k�sKo� Owner:C�i�°/'� ��}14�i�/f PoI�V Address: %3��, ��'1/ L--Gi1�9 �l� �� J`�J Permit �'s: �J r / Dates: �I—��"Ov Contractors: U►�iCll��-� �i�i��$• City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. The on-site seuage treatment system at the above address has been inspected and appears to fall into the category checked betow. (This is an existing system [ ] new construction) SYSTEM CONFORMITY C1-3): 1 "CODE SYSTEM"-A system uhich meets all the location, design, and construction standards of the current City Codes, and uhich is operating satisfactorily by treating and disposing of the entire current sewage input uithout discharging any pollutants into ground or surface waters. 2 "CONFORMING SYSTEM"-A system uhich does not meet all the location, design, and construction standards of the current City Codes, but uas installed according to the code in effect at the time of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input uithout discharging any pollutants into ground or surface uaters. 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located uithin a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and uhich is failing for any reason; and any system uith less than 3 feet of u�saturated soil or sand between the distribution device and the limiti�g soil characteristics. (The limiting soil characteristic�has or ( ] has not been identified at this time. If the limiting soil characteristic has not been ident fie , this classification may be subject to revision.) TANK CONDITION (5-10): � Tank inspection indicates: Pumpout not needed at this time. Solids accumulation in tanks indicates they shoutd be pumped out this year to help prevent future problems. Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface dischar�e. 9 Inspection risers missing-tanks could not be inspected. lnspection risers (4" dia. pipe) must be installed �n each tank at next pun�out. If tanks have not been pumped out within the last three years, they should be pumped out nou. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been purtiped out within the last three years, they should be pumped out noW. DRAtNF1ELD CONOITION (11-14): D�A'f�field inspection indicates: [111 Drainfield is dry, no surfacing evident. �f2" Some evidence of surfacing, not critical yet. 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed Within 90 days. 14 Drainfield extent and condition unknown. LtM1TING S1TE FACTORS (slope,setbacks,etc.): (�/�.-�Cl�tH6/� POTENTIAL FOR SYSTEM FA[LURE (depends on soils,water table,etc.): �L DiUiY1 $Q�t3�rl a(f�� C/OMM/�ENTS: l.7i,� fiv lac� o {� �v.� Fz�of s�r��aK�ricTn� k���.�o�� c(vc������i�ic�`a , ���v Y�i /l � = S l`-W?(C �S� s�F� %S �• r)� C�C�i� "rvt!n S ��iL(.(c�J L � - > .i- _ i � _ — � Date of Inspection Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly� but is merely an opinion of the adequacy of the system under current conditions based on the available information. This report must be kept on the pre�nises with the system locetion and pumping records. WHITE COPY/Inspectors File YELLOW COPY/Homeowner � O� O . , O � �' C ITY of ORONO �� �=tr :_�_� �.� I� � ����;���f,;,.r� ,�v I '�r�, `�1.r�:. :��`�°-, �!� MunicipalOffces r`, �� \ ", ."<7';;�`���',�G Streat Addr�s: MailinQ Address: `�EggOg' 2150 Ke!!� Paricway P.O. Box 66 Orono, NV 55356 Crystal Bay, MN 55323-0066 Owner: �A�`� Le no �� ne Address:_ 4360 c����ew�, I� Cin�Ordinance 199 requires that each exisUng on-site sewage trea�ent syst�m in Orono be inspected every�ttvo years. The on-site sewage treatment system at the above address has been i=�ected and appears to fall into the categories checked below. SYSTEM CONFORI�IITY (1-3): 3 1 ��CODE SYSTEM" An ISTS which mezts all the location,design and::�-uuction standards ofthe current Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not mzet all the lci:cn,desi�and construction standards of the currrnt Orono Vfunicipal " Code but does mert thz three foot sepazalion requirement,and which is�e'azling or an imminent threat to public health or safet}�. � NON-CO�iPLIANT SYSTEM A prohibited ISTS;an ISTS lo�.i withia a d�ignated 100-yeaz flood plain,any ISTS which may or msy not meet all the localion,dzsig�,or construction standuds of tte.w.:=rrt Oreno�funicipal Code and which is failing for any reason;and any ISTS with less than three fzet oY unsaturated soil or sand between t�:--zbution 3:�-ice and the limiting soil chazacteristics. TANK CONDITION(�-10): 6 Tank inspection indicates: � Pumpout not needed at this time. OTank must be pumped out this year (city code reyuires tanks to be pumpzc_c:evzrV 3��ars. Tank was last pumped I o-i i- 9 6 � 7 Solids accumulation in tanks is at a critical a crilical level. Tanks should�_cmpzd out 3s soon as possible. g System is dischazging to thz surface. Tarilcs must be pumped out within 3F_�.�_rs to eli.zsate surface discharge. y Inspzction risers missing-tanks coutd not be inspected Inspection riszrs(:'=.i.pipe)�st be installed in each tank at next pumpout Iftanks ha�e not been pumped out within thz last three years,they should be pumr�.�t now. 1� Inspzction pipt is located dirzctly over tank batlle(does not give accurate==;uremrnt ei solids accumulation). If tanks have not been pumped out within tha last tivez yzars,they should be pumped out now. Dt2�INFIELD CONDTTION(11-1-i): 1 t 1 1 Draintield is dry,no sur:acing evident 1� Somz evidence of surfacing,not crilical yet 13 Drainfield is saturatzd and visibly dischazging unVeated effluent to the surf�: Contact�e City Inspector immediately.Repai�must be completed within 90 days. 1� Drainfield estent and condition unknown. CONIlVIENTS: SySten. aoe5 no-� n.ee�- 4 �oot- SeQera+- o, �2-F-we�e� bott0� o� dc�..�.��--.e1� ��J ��n o�- Seti5��.4� -,-�fi�� fiable Re(��ace by �a- 3� —�-o �D 6-7 - 0� '�.ctxc Date of Inspection Septic System Inspector {` Vote: In thz event that this uupection repoR is used to satisfy the requiremenis for a mct�e or ot�a�-ansfer of property,be advised thai this repoR does not guazantee or certify that an z�isting system will continue to function properly,but is mzrely an oFT-a of the a;er,uacy of thz system under current condilions based on the availablz information. .� o�l,. � l 0�.,� � �1 � ������=�� � � CITY of ORONO ; '� ,� ;���j�:� �, �, �; � •�, 1� �'{���,�'�~ ��4�� ?►innicipal Offices ,� �N.��'�I�t<<ti �';,. I� � ;4 � � ;`r�;�`� �G Street Address: Mailing Address: `�!'E+gg0g' 2150 Kelley Parlcway P.O. Box 66 Orono, MN 55356 Crystal Bay, MN 55323-0066 . To Current Owner: Address: �3GU L�`'FFZ`^�� �-��e, Ciry Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. The on-site sewage treatment system at the above address has been inspected and appears to falt into the categories checked below. SYSTEM CONFORMITY (1-3): � 1 "CODE SYSTEM" An ISTS which meets all the location,desi�and construction standards of the curtent Orono Municipal Code. 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal Code but does meet the three foot separation requirement or n�o foot requirement for s�stems installed 1996 or earlier,and which is not failing or �"� an imminent threat to public health or safery. l .� J "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within_a desi�ated 100-year flood plain,any ISTS which may �J or may not meet all the(ocation,desi�n,or conswction standards of the current Oror.o�iunicipal Code and which is failing for any reason;and any ISTS with less than three feet of unsaturated soil or sand ben�een the distribution der-ice and the limiting soil characteristics. TANK CONDITION(5-7): S Tank inspection indicates: SO Pumpout not needed at this time. 6 Septic tanks must be pumped out this year (city code requires tanks to be pumped out once every 3 years. Tank was last pumped "2��7- ). Make sure seatic tanks are aumped through manhole and not throuQh w•hite inspection pipes This allows for the proaer cleaning. Keep water softner and iron filter dischar�e oat of septic svstem. 7 Inspection risers missing-tanks could not be inspected. Inspection risers(-�"dia. pipe)must be installed in each tank. If tanks have not been pumped out within the last three years,they should bz pumped out now. DRAINFIELD CONDITION 8-]0 : � 8 Drainfield is dry,no surfacin�evident_ 9 Some evidence of surfacin„not critical yet. 10 Drainfietd is saturated and visibly dischar�ing untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 da}�s. COMMENTS: (�tc.:�•�:���1 ;S no �- co...,.fl\, a�-� �� r���fi b;� lCpl�cc� by �a-'"�� -Z.,o�u _ �o-��—0� �``�� 1 �r�� Date of Inspection hfatt Bohrrman - Septic System Inspector Note: In the event that this inspection report is used to satisf}�the requirements for a mort�a�e or other uansfer of property,be advised that this report does not guarantee or certify that an existing system will continue to function properly,but is merel}•an opinion of the adequan ofthe system under current condi[ions based on the available infortnation. Telephone(952)249-4600 • Fax(952)Z-i9-4616 www.ci.orono.mn.us / � O� � ��� � ORON� �I - - .- � CIT� of ' '�, ' 1';�'�• ` .'*r�J Municipal Offices ��`'a ''} +� '�11' �' � ��� � ��� � '' � �' '�" q sa-a'�q-"j6o o Mailing Address: ',;'�,� �R'� _�.i,�� � ,� � ; Street Address: � _'�+` �� P.O. Box 66 ���'; � �����'���������`� '� � 2750 Kelley Parkway ��•�!9�ES�p'4�' =%' Crystal Bay, MN 55323-OOb6 ���_���� Orono, MN 55356 To Current Owner: Address: �"r ��C' �/-'' " �'��'�.``'�� City Ordinance 199 requires that each existin o°e address has beenm spected nd ppearsto falpmtothe cate o�ries checked below. The on-site sewage treatment system at the ab SYSTEM CONFORMITY (1-31� � ] "CODE SYSTEM" An ISTS which meets all the location,design and consiruction standards of the ciurent Orono Municipal Code. '_7 "COMPLLANT SYSTEM" An ISTS which does not meet all the location,design and conshvction standards of the current Orono Ivlunicipal Code but does meet the three foot sepazation requirement or two foot requirement for systems installed 1996 or eazlier,and which is not failing or an imminent ihreat to public health or safety. 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-yeaz flood plain,any ISTS which may or may not meet��less than threelfeet of unsaturat d so 1 or�sansd be[wee n the d tr bu on devi�ce and thelimt g so 1 characotenstics. reason;and any ISTS w TANK CONDITION(5-7): � Tank inspection indicates: 5 pumpout not needed at this time. 6 Septic tanks must be pumped�out this year (city code recommends tanks to be pumped out once every 3 years. Tank was last pumped 1 r�l tr. �� Malce sure se tic tanlcs are °an�aron Tilter d schare e out of sert c v tem tonsrolotno life of d a nfield wAsk tum er to test cleanina. I�ee water softne alarm float to verifv alarm is still worki ould not beinspected a'Inspection rsers(4h dia.p pe)'must be ins al ed in each tanlcn If '7 Inspection risers missing-tanks c the should be pumped out now. tanks have not been pumped out within the last three years, y DgAI'�TFIELD CONDITION(8-10�: � 8 Drainfield is dry,no surfacing evident. 9 Some evidence of surfacing,not critical yet. 10 Drainfield is saturated and visibly discharginQ untreated effluent to the surface. Contact the City Inspector immediately,Repairs must be completed within 90 days. COMMENTS: ;'�� a�`� �� '� `` � �` � � S ''�C_� �'� � W @ l�° m"+' �a +7"'�F°L o -�\ � �'?Pr'i j' �� ,�' � �� r� i i� -g ��� � ��""�A "�� P � . F / n J GY�/�" �/ � `J.o '� cs� � Septic System Inspector Date of Inspection _ ' . �._ _J..:...A �l,�r rhi: r?nnrt ({(1Z5 r � � O� O , O CITY OF ORONO 3.. ,a � ' _ � MunicipalOffices r�,, �, Street Address Mailing Address: `C� ' G~' 2750 Kelley Parkway P.O. Box 66 '�.� � ,��i Orono, MN 55356 Crystal Bay, MN 55323-0066 kEsH� To: The Current Owner of Address 4360 CHIPPEWA LA City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a periodic basis. The onsite sewage treatment system at the above address has been inspected and the following is known about the system. A sketch of the known components of the system is available for most properties at the Orono City Hall. Imminent Public Health Threat Yes _/` No ✓ If yes, please contact the Onsite Systems Manager at 954-249-4626 within 10 days of receipt of this notice. The septic system must be brought into compliance within 90 days. Failure to do so will result in referral to the City Attorney for legal action. System Identifie on-Compliant Yes No If yes, system must be brought into compliance by: December 31, 2007 / December 31, 2010 ✓ Other Septic Tank(s) Pump eeded Yes No The city recommends the septic tank(s) and/or lift tank be serviced and pumped out every three (3) years. City records indicate the tank(s) were last pumped out on l J�( (r 9' ` The tank(s) should be cleaned through the manhole and not through the inspection pipes, this allows for proper cleaning. Comments: � Inspector: r Date of Inspection: � ' �� Telephone (952) 249-4600 • Fax (952) 249-4616 www.ci.orono.mn.us Septic System Upgrade Deadline is Approaching Here's a friendly reminder to all Orono property owners with non-compliant onsite septic systems. Beginning in the mid-1990s the City began to identify those septic systems that made use of trench drainfields, a maj ority of which do not maintain the minimum required vertical separation above seasonal water tables. Each existinb system was subjected to soil borings to determine the seasonal water table depth. When a system was identified as non-compliant, the owner was notified of the need to bring the system into compliance.and given several years to complete the upgrade. The deadlines to upgrade were divided into whether or not the property was in the Shoreland District (within 1000' of a lake, or within 300' of a protected tributary stream). Properties in the Shoreland District were given until December 31, 2007 to become compliant. Properties outside the Shoreland area with non-compliant systems were allowed until December 31, 2010 to conform to the septic code. Don't wait until the last minute! The City is strongly recommending that property owners not wait until the deadline arrives to bring t�heir systems into compliance. The process to upgrade your septic system can be quite lengthy. The first step in the process is to hire a site evaluator & designer to determine what type of system is required and provide the blueprint for the system installation. The property owner inust then contract v�ith a septic s}�stem ir.sta??er to have thP system const:�a�ted. The installation of septic systems is very weather dependent, especially for mound systems, which can onTy be installed when the ground is relatively dry, i.e. typically Junc ilil•u September. Contractors' schedules fill up quickly, so it's important to start your plannin� and desibn process now to ensure a timely installation. The period of tirne from decidin�to update your septic system to the actual installation can easily eaceed three to four months or more. Please contact the Building and Zoninb Department at (952-249- 4500� ���ith an;� questions yo�i may have about brin�in� your septic system into compliance. For a list of licensed designers and 'ansta�lers you may go to ��w�.�fl.��-o�a�.��.aa�, eYick on C'ity I)epartments, elic�: on Septic, then clic�: on the lin�:to wti�ca.state.mn.us%pro�rams.