HomeMy WebLinkAbout2010-01171 - mechanical , , CITY OF ORONO PERm►T No.: 2010-olin 27�0 KELLEY PARKWAY ORONO, MN 55356- DATE ISSUED: 12/02/2010 952 249-4600 FAX: 952 249-4616 ADDRESS : 2805 CASCO POINT RD PIfY : 20-117-23-32-0015 LEGAL DESC : SPRING PARK : LOT 125 BLOCK 000 PERMIT TYPE : MECHANICAL(>$500) PROPERTY TYPE : RESIDENTIAL CONSTRUCTION TYPE : HEATING SYSTEMS VALUATION : $ 7,530.00 NOTG: I[GA"1'ING SYSTF,M: LENNOX -MODEL SLP09U1[1 l OV60C- 1 12Q000 INPUT BTU'S, ]04,500 OUTPUT BTU'S APPLICANT MECHANICAL 94.13 SEDGWICK HEATING &A/C STATE SURCHARGE MECH (VALUATION) 5.00 1408 NORTHLAND DR- SUITE 310 MENDOTA HEIGHTS, MN 55118- MAIL-[N FEE 0.77 (952) 881-9000 TOTAL 99.90 OWNER FROMMELT, ROGER 2805 CASCO PT RD VVAYZATA, MN 55391- AGREEMENT AND SWORN STATEMENT The N°ork for�+�hich this permit is issued shall be performed according to the approved plans and specitications,appiicable City approvals,and the State Building Codc. This permit is for only the work described and does not grant permission for additional or related work which requires scparatc permits. All provisions of laws and ordinances governing this type of work shall be compied with whether or not specified herein.This permit will expire and become null and void ifconstruction authorized is not commenced within I 80 days of the date of issuance,or if construction is suspended for a period of 180 days at any time a�ter work has commenced. "Che applicant is responsible for assuring all required inspections are requcsted in conlormance with the State Building Codc.This permit may be revoked at any time for due cause. C���l�-C�-e� ��l D a—1 /� ��. p�/ �� Applicant Permitee Signature Date Issu 13y Signature Date SEPARATE PERMITS REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE. � :�o � Tc1 FOR CITY USE ONLY '� City of Orono ' � ' 4 � ��� P.O.Box 66 Date Received: Permit# (4 O+1 � �. 2750 Kelley Parkway ��.� a� a���� � �� Crystal Bay,MN 55323 Approved By: Amount$: �� ���.1��o�' Phone(952)249-4600 Fax(952)249-4616 ��tt�usf% CITY OF ORONO-MECHANICAL PERMIT (All Commercial permits must be approved by the Building Official or[nspector and/or Fire Marshall) GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within two working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECENE A PERMIT. WORK MUST NOT BEG[N UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Desi�ns—Complete calculations,details and specifications are required for each heating,ventilation,humidifieation-dehumidification,and air conditioning installation including heat loss/heat�ain calculation,design temperatures,equipment ratings and identification as to type,manufacturer and model. Data shall be presented on form provided. 4. When any new construction or remodeling is involved,a separate building permit mu��bc � �• � < obtained. - - ' '.�� 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. �t(.. — L LU lU 6. All work must be inspected(rough-in and final). Call(952)249-4600. (24-48 hour notice required) CITY OF ORONO 7. House Heating Test Record must be submitted before final. TYPE OF PERMIT (Check All That A 1 ) ❑ Residential ❑Commercial(Approval Required) ❑New ❑ Additional ❑ Repairs ❑ Replace Job Site /Owner Information: ��- � � , Site Address: � ��� �C{ �� C Owner: C�r rn rn l� Mailing Address: �GU � �G�O �' '�� City: � , (J n�� Zip: � S �� � Home Phone: "I� -L� -I 1 -��jS� Alternate Phone: �-C� �o� ,�aj y� 3 ��j� � Contractor Information: Contractor: Contact Person: �� � Address: ��T�N��SL��te Bond #: � � �)� � 1408 Northland Drive Suite 310 City: _ Mendota Heigtg;,ry1N S8�2o Expiration Date: �� � �952j881-�Ob�— Phone: Alternate Phone: ❑ Insurance-Current: , 1 MECHANICAL SYSTEMS BEING INSTALLED Note: All Geothermal Systems will now require a Site Plan& Review by our Building Official. IS THIS GEOTHERMAL? ❑ Yes �No HEATING SYSTEMS Quantity: � Make: ���'YVv��-�' Model: � (,(, �v�)� Fuel: Flue Size: Input BTUs: � Output BTUs: � � l �(�� CFM: COOLING SYSTEMS Quantity: Make: Model: Tons: H. Power FIREPLACES Gas Factory Firepiace Brand Name: Wood Burning Fireplace Wood Stove Model No.: Wood Stove With Flue VENTILATION No. Kitchen Exhaust duct recirculating cfm No. Bath Exhaust(must have duct outside) cfm No. Other Fans: Locations cfm FUEL STORAGE (Must be approved by Fire Marshall ijproposing to abandon tank in place.) � Installation � Removal Fuel Oil: gallons ❑ Underground ❑ Inside ❑Outside LP Gas: gallons Other: GAS LINE ONLY � Outdoor Grill ❑ Other/List What&Where: . 2 PERMIT FEE CALCULATION(S) BASED OFF - 2002 STATE STATUE � Yes,this section applies The replacement of a Residential fixture or apnliance that meets all three of the following requirements: 1. Does not require modification to electrical or gas service. 2. Has a total cost of$500.00 or less;excludin�the cost of the fixture or appliance: and 3. Is improved,installed or replaced by the homeowner or licensed contractor. Skip next section,if this applies; Cost of Permit $ 15.00 State Surcharge $ 5.00 Mail-In Fee(If Applicable) $ 2.00 Total Permit Fee $ PERMIT FEE CALCULATION S -JOBS OVER $500.00 If above does not apply;follow guidelines below: 1. CONTRACT PRICE * is 1.25%of contract price with a(Minimum Fee of$50.00) �] 5 3 C� X .o�zs $ �-� I 3 (contract price) (minimum$50.00) 2. STATE SURCHARGE ** Add the State Bldg Code Div. Surcharge(Minimum Fee of$5.00) � 5 � �J x.0005 $��� (contract price) (mm� um$5.00) 3. POSTAGE&HANDLING(Only on Mail-In Applications) $ 2.00 4. TOTAL PERMIT FEE(Add Lines 1-3 Above) $ � �� ■ * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor,profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor or instailations are furnished by the owner, tenant or any other party, the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. ■ **The STATE SURCHARGE is.0005 times the Contract Price or a minimum of$5.00. MECHANICAL PERMIT APPLICATION AGREEMENT The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the State of Minnesota, and certifies that all statements made on this application are complete, true and correct. Applicant's Signature: "�'� ' Date: \� � � Reset Form 3 � � ��i�e�9lr�tk HEATING dt AIR�ONDITIONING CO. R E S I D E N T 1 A L H E AT I N G D ATA S H E ET Com(ort you can count on JOB NAME: , DATE '� ADDRESS: 2 � �•- � - - f' ' �� OUTDOOR TEMP: INDOOR TEMP: TEMP. DIFFERENCE: DE51GN TEMPERATURE DIFFERENCE MOVABLE GLASS WINDOWS SQUARE � � � � � � � � ,� � � � � � 9TUH FEET HEAT 7RANSFEH MULTlPLIER HEAT LOSS SINGLE GIASS 39 4b 52 58 66 71 78 94 90 97 103 110 116 123 SINGLE GLASS W(STt�RM 21 25 28 31 35 38 42 45 43 52 56 59 63 6& DOUBLE ^uLAS5 28 32 37 41 46 50 56 60 64 69 73 78 82 87 DOUBi.E GLASS W/STORM 16 19 21 24. 27 29 32 35 37 40 42 46 48 5U DEBIGN T�l1AP€RATURE OfFFERENCE SLIDING GLASS OOORS SQUARE � � � � � � � � � � � � � � B7'UH FEET HEAT TRANSFER MULTIPIiER HEAT IOSS SINGLE GIASS 42 48 5b &Z b'9 76 83 90 97 104 110 117 124 131 SINGIE GIASS W/STORM 22 26 29 33 37 40 44 48 51 5b 58 82 66 70 DOUBLE GLASS 29 34 39 43 A8 5:i 5B 63 67 72 77 82 87 99 SaUARE DE5�G111 TEMPERATURE DIFFEAENCE BTUH DOORS FEET � � � � � � � � � � � � � � HEAT LOSS HE.A7 TRANSFER MULTIPLIER SOLID WOOD 31 36 41 46 51 56 62 67 T2 77 82 87 92 97 SOUD WOOD•" 18 21 24 27 30 33 36 39 42 45 47 50 53 56 METAL URETHANE 23 27 30 34 38 42 45 49 53 57 60 64 68 72 METAL URETHANE" 13 16 1$ 20 22 25 27 29 31 33 36 38 40 42 ••Weatherstrip d or Storm RUNNING FEET �s�_� CEILING HEIGHT x r_ GROSS WALL �._.���"�-� WALLS WINDOWS & DOOR AREAS _____. + � ._ '-�-- NET WALL AREA � SQUARE DESIGN TEMPERATUAE DIFFERENCE BTUH FRAME WALL FEET � � � � � � � � � � � � � � HEAT LOSS HEAT TRANSFER MUITIPLIER NOINSULATION 8 10 11 12 14 15 17 18 19 21 'l2 23 25 26 R-11, 3" INSULATION 2.7 3.1 3.6 4.0 4.5 4.9 5.4 5.8 6.3 6.7 7.2 7.6 $.1 8.5 R-13, 3-1/2" INSULATION Z 2.1 2.4 2.8 3.2 3.5 3.8 4.2 4.6 4.9 5.3 5.6 5.9 6.3 6.6 G R-13 + 1" POLYSTYPENE 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5.4 5.7 R-19 + 1/2" POLYS'fYRENE 1.6 1.9 2.2 2.5 2.8 3.0 3.3 3.6 3.8 4.1 4.4 4.7 4.9 5.2 DESIGN TEMPERATURE DIFFERENCE MASONRY WALL SQUARE B7UH ABOVE GRADE FEET � � � � � � � � � � � � � � HEAT LOSS HEAT TRANSFER MULTiPL1ER NOINSULATION 16 18 21 23 26 28 31 33 36 38 41 44 46 49 R-5, 1" INSULATION 4.3 5.0 5.8 6.5 7.2 7.9 8.6 9.4 10.1 10.8 11.5 12.2 13.0 13.7 R-11, 3" INSULATION 2.3 2.7 3.1 3.5 3.8 4.2 4.6 5.0 5.4 5.8 6.2 6.5 6.9 7.3 R-19, 6" INSULATION 1.4 1.7 1.9 2.2 2.4 2.6 2.9 3.1 3.4 3.6 3.8 4.1 4.3 4.6 DESIGN TEMPERATURE DIFFERENCE MASONRY WALL SQUAHE BTUH BELOW GRAOE FEET � � � � � � � � � � � � � � HEAT LOSS HEAT TRANSFER MULTIPt1ER NOINSULATION 4.4 5.1 5.9 6.6 7.3 8.1 8.8 9.6 10.311.011.812.513.214.0 R-5, 1" INSULATION 2.6 3.0 3.5 3.9 4.3 4.8 5.2 5.7 6.1 6.5 7.0 7.4 7.8 8.3 R-11, 3" INSUTATION 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5.4 5.7 R-19, 6" INSULAT�ON 1.2 1.4 t.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 HEAT LOSS SUBTOTAL '� , , . � Heat Loss Subtotal from Pa e 1 S � SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH CEIUNG FEET � �' � � � � � � � � � � � � HEAT LOSS HEAT TRANSFER MULTIPLIER NOINSULATION 18 21 24 27 30 33 36 39 42 45 48 51 54 57 Fi-11, 3" INSULATION 2.6 3.1 3.5 4.0 4.4 4.8 5.3 5.7 6.2 6.fi 7.0 7.5 7.9 8.4 R-19, 6" INSULATION 1.6 1.9 2.1 2.4 2.6 2.9 3.2 3.4 3.7 4.0 4.2 4.5 4.8 5.0 R30, 10" INSULATION 1.0 1.2 1.3 1.5 1.6 1.8 2.0 2.1 2.3 2.5 2.6 2.8 3.0 3.1 R-38, 12" INSULATION 0.8 0.9 1.0 1.2 1.3 1.4 1.6 1.7 1.8 2.0 2.1 2.2 2.3 2.5 FLOOR OVER AN SnUAHE DESIGN TEMPERATURE DIFFERENCE gTUH UNCONDITIONED SPACE FEET � � � � � � � � � � � � � � HEAT LOSS HEAT TRANSFER MUITIPLiER NOINSULATION 10 11 13 14 16 17 19 21 22 24 25 27 28 30 R-11, 3" �NSULATION 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 5.6 6.0 6.4 6.8 7.2 7.6 R-19, 6"INSULATION t.6 1.8 2.1 2.3 2.6 2.9 3.1 3.4 3.6 3.9 4.2 4.4 4,7 4.9 R-30, t0"fNSULATION 1.1 1.3 1.5 1.7 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.1 3.3 3.5 SQUARE DESIGN TEMPERATURE DIFFERENCE gTUH BASEMENT FLOOR FEET � � � � � � � � � � � � � � NEAT LOSS HEAT TRANSFER MULTIPLIER BASEMENT FLOOR 0.8 1.0 1.1 1.3 1.4 1.5 1.7 1.8 2.0 2.1 2.2 2.4 2.5 2.7 � DESIGN TEMPERATURE DIFFERENCE CONCRETE SLAB WITHOUT LfNEAR BTUH PERIMETER SYSTEM FOOT � � � � � � � � � � � � � � HEAT LOSS HEAT TRANSFER MULTiPtiER NO EDGE INSULATION 25 29 33 37 41 46 49 53 57 81 fi5 69 73 77 1" EDGE INSULATION 13 15 17 19 21 23 25 27 29 3l 33 35 37 39 2" INSULATION 6.3 7.4 8.4 9.4 10.5 11.5 12.6 13.6 14.7 15.8 16.8 17.8 18.9 70.0 CONCRETE SLAB LINEAR QESIGN TEMPERATURE DiFFERENCE gTUH WITH PERIMETER SYSTEM FOOT � � � � � � � � � � � � � � HEAT LOSS HEAT TRANSFER MULTIPLIER NO EDGE fNSULATION 57 67 76 68 95 105 114 124 133 143 152 162 171 181 1" EDGE INSULATlON 34 40 4& 52 57 63 69 74 80 86 91 97 103 109 2" EDGE INSULATION 28 33 37 42 47 51 56 61 65 70 75 79 84 89 An additional infiftraYiar�load is cafculated anly if the home ia looaely constructed or when windaw infiltration is greater than .5 CFM per linear foot of c�ack. ^_ FLOOR SQ FT. x ____.___CEILING HEIGHT = CUBIG F? i(U FI LTRATIC71111 VENTELATlON Q•'�x���� �T T � = CFM MECHANICAI VENT7LC,TlQN CFM1 = FRESH /!IR {NTAKE � DE&IGN TEMPERATURE dIFFEREIVCE gjUN CFN� 3Q 35 40 46 SO 56 6L� 66 70 75 80 96 90 � �EAT LOSS HEAT TRRM14SFEH MUi�TiPItER INFILTRATIQN � 33 39 4A 50 55 61 6fi 72 l7 83 98 34 99 1U5 � =� MECHANlCAL VENTILP.TIQN � ' 33 39 44 50 55 61 66 72 77 83 88 34 39 105 - HEAT LQSS SUBTOTAL DUCT LOSS BTUN HEAT LOSS R-4, 1" Flexible Blanket Insulation: ADD 15% 1.151 R-7, 2" Flexible Blanket Insulation: ADD 10% (.10! TOTALNEAT LOSS NOTE: All Heat Transfer Multipliers from ACCA Manuai "J" Sixth Edition. HL-841-L7 002344 Litho U.S.A. SEDGWICK HEATING & AIR CONDITIONING CO. HEATING JOB NO. ` ��� � 8910 WENTWORTH AVENUE SOUTH • MINNEAPOLIS,MN 55420 • (952)881-7739 TEST RECORD � , , _� �, ,,,. FC��V� ADDRESS v` ,�/•I� ��/h/`� ' ' .�� ' CITY v D OCCUPANT � OWNER^ � � � � �V 1 ^I� SOLD BY��rriS�� INSTALLED BY � �� v �NO MAKE� � ,� ^ MODEL � � �� � 1 ( � �I� � � SERIAL NO. ��S �� `C�ln� INPUT � ��-" • J'� -�, ��'�( THERMOSTAT-�1�1 l• VENT SIZE��� - VAWE ✓� TYPE OF LINER � ,r-_-._. LIMIT LINER SIZE LIMIT SETTING ��� FILTERS: SIZE,�� r` �Cr�� ' NUMBER I s�. i � e T_ FAN SETTING WIRING �/l.�LC I^j_.�,��/L7l)l �` PILOT TYPE r� ��^ TEST TAG c' _____. IGNITION MODEL LIGHTING INST. PILOT TIMING � L ' � �� �_ � ,_�I, t �: `�,, DATE TESTED I�/ �J PRESSURE � � PEFICENT CO2 �/•� _� . � - ,�-- �' INPUT CFH O PERCENT OZ I� J COMPANY TESTING A / ` STACK TEMP. PERCENT CO_� NAME OF TESTER U' FORM 235(REV.6/08) FOFM DISTRIBUTION: WHITE COPY-JOB FILE YELLOW COPY-CITY