Loading...
HomeMy WebLinkAboutRe: retaining wall R, • . � ' Christine Mattson From: Adam Edwards Sent: Thursday, May 21, 2015 3:26 PM To: Christine Mattson Cc: Melanie Curtis Subject: RE: 2618 Casco Point Road /#2015-00577 Approved and Stamped plan. In our discussions he mentioned moving more of the reta'sning wall closer to the property line, but all the revise plans showed was roof guttering and catch basins so I approved the roof guttering a catch basin plan. Adam From: Christine Mattson Sent: Thursday, May 21, 2015 10:56 AM To: Adam Edwards Cc: Melanie Curtis Subject: 2618 Casco Point Road / #2015-00577 Adam, Please review the attached survey regarding a new proposed retaining wall and provide comments before May 28, 2015. Thank you. Christine Mattson Planning Assistant City of Orono 2750 Kelley Parkway `, Orono MN " 55356(physical addressJ PO Box 66 ;, Crystal Bay ;',, MN ; 55323-0066 (mailing address) �' 952.249.4620 ' � 952.249.4616 � cmattson@ci.orono.mn.us "; �?' www.ci.orono.mn.us Office Hours: Monday- Friday 8 am to 4:30 pm PLEASE NOTE: Summer Office Hours start Monday, May 18,2015 Monday-Thursday: 7:30 am to 5 pm/ Friday 7:30 to 11:30 am OUR OFFICE WILL BE CLOSED: Monday, May 25, 2015 (Memoria!DayJ 1 Melanie Curtis From: Melanie Curtis Sent: Monday, June 01, 2015 2:39 PM To: Adam Edwards Cc: Christine Mattson Subject: RE: 2015-00006 2618 Casco Point Rd Adam We have received a revised plan for the walls associated with this garage permit. I have placed them in your inbox for review along with an email from the neighbor to the south. Please review and approve, if appropriate. Melanie Curtis �952.249.4627 �mcurtis@ci.orono.mn.us From: Adam Edwards Sent: Wednesday, January 07, 2015 3:36 PM To: Christine Mattson Cc: Melanie Curtis Subject: 2015-00006 2618 Casco Point Rd Chris, I've completed a grading review of the proposed plans for the permit/ property listed in the subject line and provide the following comments: 1. The southern retaining wall has a lower top of wall elevation than bottom of wall elevation (TW=940.0; BW=941.5). 2. The middle of the southern retaining wall is listed an 4 Ft(TW=945.0; BW=941.0). The northern retaining wall is shown to be 4 ft. (TW=947; BW=943 &TW=946; BW=942;TW=946.5; BW=942.5) Walls 4' or greater in height must be designed by a licensed professional, and plans must be submitted to the City for review. 3. The site plan/survey does not depict the drainage pattern as required by the City Survey submittal standards. 4. Based on the proposed contour lines, the plan would direct surface drainage from the west of the house into the southern neighbors property Via a swale. A site plan should be developed to ensure runoff is not directed into the neighboring properties. 5.A silt fence or other erosion control measure is not is not depicted on the plan. A silt fence or other appropriate erosion control mechanism should be planned for and must be installed and inspected by the City prior to any land disturbing activities. The Contractor must provide a minimum 24 hour notice prior to inspection. Adam Adam T. Edwards, P.E. Director of Public Works/City Engineer City of Orono (952) 249-4661 aedwards@ci.orono.mn.us 1 �f ' �� 1 Melanie Curtis From: essenjw@aol.com Sent: Monday, June 01, 2015 1:23 PM To: Melanie Curtis; eric@vogueconstruction.com; essenjw@aol.com Subject: Vogstrom revised permit Melanie & Eric, I spoke to both of you over the past few days and I want to e-mail both of you to be sure we are all on the same page. Melanie is waiting for a final revised site plan to attach to the revised permit. The plan will show a three (3) foot set back for the retaining wall for a portion of its length around the south east corner of the house. It will also show a catch basin behind the wall at the south east corner of the garage, a swale along the length of the retaining wall between the wall and the property line, and it will indicate there will be gutters and downspouts on the garage that drain toward the driveway and street. In my conversation with Eric he confirmed he understands the back side of the retaining wall will be on the north side of the 3 foot setback line. Dirt will be imported to back fill and restore the original grade and contour the swale between the property line and the wall. If I have miss communicated this in any way please let me know. Thanks Jeff Essen i