HomeMy WebLinkAbout2015-00434 (fire system-sprinkler system) ` CITY OF ORONO
* 2 0 1 5 - 0 0 4 3 4 *
2750 KELLEY PARKWAY DATE ISSUED: 04/29/2015
ORONO, MN 55356-
952 249-4600 FAX: 952 249-4616
ADDRESS : 3225 CASCO CIR
PIN : 20-117-23-43-0021
LEGAL DESC : SPRING PARK
: LOT 029 BLOCK 000
PERMIT TYPE : FIRE SYSTEMS
PROPERTY TYPE : RESIDENTIAL
COI�ISTRUCTION TYPE : SPRINKLER SYSTEM-IN BUILDING
NOTE: INSPECTIONS ARE DONE BY FIRE MARSHALL,JAMES VAN EYLL.
PLEASE CALL JAMES VAN EYLL DIRECTLY AT:(952)473-9701 TO SET UP AN INSPECTION.
ENTER THE VALUTATION 18225
APPLICANT FIRE SPRINKLER-RESIDENTIAL 227.81
STATE SURCHARGE VAL OTHER 911
VIKING AUTOMATIC SPRINKLER CO. MAIL-IN FEE 2.00
301 YORK AVE
ST. PAUL, MN 55130- TOTAL 238.92
(651)588-3300 Payment(s)
Minnesota State License#: BUIL-C-005 CHECK 10045090 238.92
OWNER
LEESTMA, MARTIN&KATHRYN
3225 CASCO CIR
WAYZATA, MN 55391-
AGREEMENT AND SWORN STATEMENT
The work for which this permit is issued shall be performed according to
the approved plans and specifications,applicable City approvals,and the
State Building Code. This permit is for onty the work described and does
not grant permission for additional or related work which requires separate
permits. All provisions of laws and ordinances goveming this type of work
shall be compied with whether or not specified herein.This permit will
expire and become null and void if construc[ion authorized is not
commenced within 180 days of the date of issuance,or if construction is
suspended for a period of 180 days at any time after work has commenced.
The applicant is responsible for assuring all required inspections are
requested in conformance with the State Building Code.This permit may be
revoked at any time for due cause.
n�
� �/ � ,�C,�''Yl���1 t� ,E� �' /
1 /.5
Applicant Permitee Signature ate Issued By Signature Date
,
;
City ofi Urono
2750 Kelley Parkway
Orono MN 55356 952-249-4600
Receipt No: 3.013277 Apr 29, 2015
4iking Automatic Sprinkler
Previous Balance: .OU
Permits
2015-00434 3225 Casco Cir z�7,g�
lO1-32530
Mechanical;Septic/Other
Permits
2015-0�434 3225 Casco Cir g.��
lU1-20802
Due to govts-State
Permits
2015-00434 3225 Casca Cir 2.00
101-34440
Bldg Permits-mail in fees
Total:
--------238.92
Check ----"-`-----_-
Cherk No: 1004509076 2:?g y2
Payor:
Viking Automatic Sprinkler
Total Applied: 238 92
Change Tendered: ,00
U4/29/21�15 10:30AM
City �f Orono
� 2750 Kelley Parkway
Orono MN 55356 952-249-4600
Receipt No: 3.013277 Apr 29, 2015
Viking Automatic Sprinkler
—�.fl�
^�•��^�us Balance: .00
/ ts
� )0434 3225 Casco Cir 227.81
?530
C�NOFORONO DATE TIME \/ �ical;Septic/Other
INSPECTION NOTICE CA�LED IN ts
SCHEDULED 00434 3225 Casco Cir 9.11
PERMIT NO. cOMPLETED �j -- 0802
ADDRESS 32� —��'���--�"� ��"� ts9ovts-State
�" 00434 3225 Casco Cir 2.00
OWNER j444o
TELEPHONE NO. Permits-mail in fees
CONTRACTOR '�J ------- 23$-92_
� � l: _______________
� DESCRIPTION ��
<
eck No: 1004509076 238.92
W ❑ FOOTING yOr:
Q ❑ POURED WqLL � DEMO-FINAL ❑ SEPTIC FINAL king Automatic Sprinkler
❑ PLUMBING RI ❑ EXCAV/GRADING/FILLING 1 Appl ied: 238.92
Zy ❑ FOUNDATION WATERPROOF
❑ RADON SLAB � PLUMBING FINAL ❑ TREE REMOVAL ,ge Tendered: .00
Q ❑ FRAMING � MECHANICAL RI ❑ SITE INSPECTION _______________
� ❑ INSULATION � MECHANICAL FINAL ❑ RATED WALLS 04/29/2015 10:30AM
Q ❑ FINAL � WOOD BURNER/FIREPLACE ❑ COMPLAINT
W ❑ AS BUILT-SURVEY � WATER HOOK-UP ❑ FOLLOW-UP
Z ❑ SEWER HOOK-UP ❑ FOUNDATION/REMOVAL
v ❑ DEMO-SITE ❑ SEPTIC INSTALL
2 OWNERICONTRA�OR TO MEET YpU:_YES_NO
� COMMENTS:
j ��k � �.� � �, .L ��..,. 5��•-�...�
0
�.
¢
0
�
W
�
Q
�
W
W
�
J
d
� ❑WORK SATISFACTORY:PROCEED
❑CORRECT WORK&PROCEED �PROJECT COMPLETE
�W ❑ISSUE CERTIFICATE OF OCCUPANCY
❑CORRECT WORK,CALL FOR REINSPECTION
(� BEFORE CWERING TEMPORARY
O CORRECT UNSAFE CONDITION WITHIN PERMANENT
INSPECTOR WILL RETURN HOURS. ❑ pHOTO TAKEN
❑STOP ORDER POSTED.CALL INSPECTOR �CITATION ISSUED
❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS.
Call for the next inspection 24 hours in advance. (952� 249-4600
�wner/Contractor on site:
Inspector.� �,�'„� �� �
J
White Copyllnspector's File Canary CopylSite Notiee
t ��`,
"`�� FOR CITY USE ONLY
f Q � �— , �
� �+.. ��� Cl�'Of�1'0110 Date Received ��j � ��:,Permit# (�; � '���J�-
P.O.Box 66
�`
'� 2750 Kelley Parkway Amount $ �-f �4 ��� `" �
�,, F � �� Crystal Bay,MN 55323 __'�
�,��,.� '�> > �:;' (952)249-4600 Approved By
� �,`� Recommends: A roval Denial ❑
\�''1�1.1}li?C� ;
CITY OF ORONO—AUTOMATIC FIRE SPRINKLER/GENERAL PERMIT
(All permits must be approved by the Pire ilarshall and/or Building Official)
1. Permits are required for all fire sprinkler installation and repair. All work shall be done by a licensed
fire sprinkler contractor. Two sets of plans, specification data sheets, �re flow tests and hydraulic
calculation sheets shall be submitted to the Orono Fire Marshal a minimtam of 7 days beFore titart ol'
«�ork.
2. Permits can be applied for by mail at PO box 66, Orono,MN, 55323 or in person at,
2750 Kelly Parkway;Phone: (952)249-4600. Permits are also available online at:
����ti�.ci.orono.mn.us
3. All systems shall be designed, installed and maintained to N.F.P.A.-13,N.F.P.A.-25,Minnesota State
Building Code,Minnesota State Fire Code and Standards. All attic systems are to be spaced at
maximum 130 square foot coverage. Plastic pipe will not be allowed at any time in attic spaces.
4. All equipment installed shall be U.L. or F.M. approved for fire protection service. Water flow test
shall be completed on all new systems. Water flow test reports shall be submitted to the Orono Fire
Marshal along with plan submittal.
5. Yard or wall post indicator valves are required. All indicating and control values installed shall be
provided with tamper protection. On dry systems,the control valve to service the pressure switch(air)
shall be supervised.
6. Inspectors test valve shall be installed on each floor level or zone of system. All systems shall have
main drain and inspectors test valves piped to the outside.
7. No water is to be introduced into the sprinkler system until main has been thoroughly flushed. 200#
air test and flushing shall be witnessed by the City of Orono Water Department.
8. An approved audible/visual device wired to main flow switch shall be installed above F.D.
connection and in areas normally occupied by tenants.
9. EXISTING SYSTEMS: If any changes in the hydraulically most demanding area, change in
occupancy classification or an addition of 20 or more heads,hydraulic calculations and flow test will
be required.
10. The Orono Fire Marshal shall witness all final flow or trip tests. Appointments can be made by
calling the Fire Marshall at(952) 473-9701, 8:00-4:00 p.m. Monday-Friday. 24-hours notice is
requested.
11. When required, (30 foot building height)stairwell standpipe's shall have 2 '/2 gate valves installed
with 2 '/z x 1 '/z caps.
C `i�c
�..,�., �. ';�. , , . �4',���r�r���:..,...... ........���`A���^�LR\,F.i�"�i���J�i�;L ,�,�',,,it ��,�.
�PI a C:heck One_-- �
� New ❑ Addition ❑ Remodel ❑ Replace
r� ���� � � _� x ��������, �E
t�T��.�i�ri �� � �
��� e,. :.��. _.> �f�, �
Site Address: �o�a�S Cd S�D ���r c.�e
Owner:
Le�eS-f-w� a Mailing Address: �'�Y Za�'� ,�/�N
City: � �0 /�1.0 Zip: ��`3 � �
Home Phone: Alternate Phone:
W� N �k� � ��\��1✓ � L�u���,�y�^'�„� � �`s'.
➢
Contractor/App.: � ►/� ��'r Contact Person: '� �� OVS,��/
/
Address: 30� ).✓or k A �e • State License#: C��S
City: .�, t�evt K � Zip: -��� Expiration Date: � ��
Phone: �/— .SS�'' 3 3 O a Alternate Phone: 6�l— SS g- 3a a �
� .�P�����T v ����'RIl'�T�ER�1'����['��. ? r,��., , ����� ��
❑ Commercial—Fire Sprinkler �Residential—Fire S rip nkler
Fire Systems Permit Fire Systems Permit
* Base Price=Contract Price: $ I7�, 4���x.0125 =$ Ot o��• D( (Minimum$50.00)
�-
* Surcharge=Contract Price: � � OT x.0005 =$ l• �
* Mail-In Fee(Only On Mail In Applications) _$ 2.00
*Total Cost of Permit: _$ ��• 9 4�
The undersigned herby applies to the City for issuance of a Sprinkler Systems Permit. Applicant agrees
that all systems shall be designed, installed and maintained to N.F.P.A.-13,N.F.P.A.-25,Minnesota State
Building Code,Minnesota State Fire Code and Standards, and certifies that all statements made on this
a lication are complete,true and correct.
.� � y ,o �.�
Applicant Date
� 301 York Avenue
V� K 1 N � St. Paul, MN 55130
T:651 558 3300
AUTOMATIC SPRINKLER C0. F:ssi 55a s3�o
8 June 2015
City of Orono
2750 Kelley Parkway
Orono, MN 55356
Dear recipient,
Viking Automatic Sprinkler Company recently a�plied for a permit [Permit #
2015-00434] to install a 13D fire suppression system at the location of 3225
Casco Circle. The home builder decided to use the services of another fire
suppression installer. Viking Automatic Sprinkler Company is requesting a
refund for all permit fees as we will not be doing any work at this location.
Attached you will find a copy of the permit and receipt for payment.
Sincerely,
Dale Lipovsky
651-558-3221 l �.�C� _�,�.
Viking Automatic Sprinkler Co. ��� ~ '
�
��; . , ,_c.y
i ����1 , r� , ���-�`�-6
�����C�.�-�
��C_L`^Z( �►, ,'''���'�' �- „'�.
��
G� �'� ' , �, '' � ��'
-�/
, �� < ���
�,.e._� �°�- �����
.
June 16, 2015
Peter;
Attached is a refund request from Vikin�Automatic Sprinkler, for permit#2015-00434 located at
3225 Casco Cir. Per the attached letter they will not be doing the work on this project.
They would like a refund. Roger has agreed to refund the cost of the permit, minus the State Surcharge
and Mail-In Fees.
Please refund Vikin�Automatic Sprinkler Co.$227.81 for the cost of the permit only.
Thank you,
�����
Rachel Dodge
Administrative Assistant
Send refund check to:
Viking Automatic Sprinker Co.
301 York Ave
St. Paul, MN 55130
, �
V, �sNG
AUTOMATIC SPRINKLER C0.
a subsidiary ol AP/6YOYp,/IK.
LETTER OF TRANSMITTAL
Date: Apr 14,2015 Job# 125366
To: Ciry of Orono Attention: Fire Sprinkler plan reviewer
Fire Sprinkler Plan Reviewer Regarding: Leestma Residence
Address P.O.Box 66 2750 Kelley Parkway 3225 Casco Cirlce
City Orono State MN Zip Code 55323 Wayzata,MN 55391
We are sending you...... � Attached � U�der separete Cover via the following items:
COPIES DATE DESCRIPTION
2 Apr 14,2015 Submittal Drawings
2 Apr 74,2015 Hydraulic Calculations
2 Apr 14,2015 Material Data Sheets
1 Apr 14,2015 Permit Application
1 Apr 14,2015 Permit Check
2 Apr 14,2015 FlowTest
These items are transmitted: tas�n�ked�oW�
� For approval (� Approved as submitted (� Approved as noted i� Resubmit copies for approval
(� For your use (� Returned for corrections (` Returned for clarification '� Submit copies for distribution
Other:
(1 As requested (� (� Return corrected prints
(� For review and comments ( (^ For Bids Due Date:
Prints returned after loan to us
Remarks:
Copied to: If enclosures are not as noted,please notify us as soon as possible
Siqned:
Name Title Date
Dale Lipovsky Engineering Technician Apr 14,2015
VIKING SETS THE STANDAR!D...
301 York Ave.
�na �a �� ST. PAUL, MN 55130
�� PHONE: (651) 558 3300
AUTOMATIC SPRINKLER CO. F�(: (651) 558-3310
HYDRANT FLOW TEST RESULTS
TIMEOFTEST: D ��� ( JOB: ���SfNa%�q �_P����..-�[�
DATE: y��/�S TAKEN BY: .J c j�- �• `�.i D✓S�y�
WITNESS: �.-��.�-�/ C9'� �../C"�'3rt o
HYD.# NO.OF OPENINGS PITOT TUBE GA�LONS PER MIN. STATIC PRESSURE RESIDUAL PRESSURE
0
1-2-1/2" � � ��� �� K'` �
2-2-1/2"
1-4-1/2"or 5"
GALLONS PER MIN. COEFFICIENT � �i
UNDERGROUND SIZE:
Q=29•84cd�-2�z� DEAD END/CIRCULATING ��r��'r� ���
z
Q=29.84cd✓�-4%:"@ UP OPENING ON HYDRANT:��'or 5" �.
�' �
i
SK.ETCH: .90 0.8� �.��
NO TH
f
, � -��� �'-�' i` '�Z a
// ��,� av�'�`r �r �� —1
��11� �� �
.
�
�tOUt� �� cas�o c►r�lt
0
�„ ����•.
!�',��'����"� � ��� x� ,= .
��` R �
f �������N. f ' ��, /.
������ ����
�
, � , � �
AUTOMATIC SPRINKLER C0.
Fire Suppression Sprinkler Svstem
Materials Information
Prepared for:
Leestma Residence
3225 Casco Circle
Wayzata, MN 55391
on:
April 14, 2015
a�� C c��co �
People. Integrity. Professionalism.Excellence � �� ��—��l'3 U
1
Table of Contents
Section 1: Fire Sprinklers
Section 2: Pipe Types
Section 3: Pipe Fittings
Section 4: Pipe Hangers
Section 5: Valves
Section 7: Miscellaneous
Section 1 : Fire Sprinklers
' Bulletin 006 Rev. I
Model RFC30 (SIN RA0611) °J
C� Model RFC43 (SIN RA0612) �.
Model RFC49 (SIN RA0616) �
Residential Flat Concealed �
Sprinklers `
A Residential Flat Concealed
Sprinkler engineered for a minimum �°��
-�� a ��
design density of 0.05 gpm/ft2 with W �
low GPM requirements. _ �
Features
1. Very low water flow requirements.
2. Cover plate attachment (Plain or Perforated)
with '/2" (13mm)Total adjustment.
3. Thread-On/Thread-Off or Push-On/Thread
Off cover attachment option.
4. Smooth aesthetic ceiling profile.
5. Available in brass, chrome and black plated
or painted finishes. Plain Cover P�ate
Listings & Approval
1. Listed by Underwriters Laboratories, and
certified by UL for Canada (cULus)
UL Listing Categories
Residential Automatic Sprinklers � � "� � �
UL Guide Number ���� � � � �
VKKW
Product Description -
Model RFC30, RFC43 and RFC49 Concealed Residen- T • - - - - - - - �
tial Sprinklers are fast response residential fusible solder
link automatic sprinklers. Residential sprinklers differ
from standard sprinklers primarily in their response time
and water distribution patterns. Perforated Cover Plate
Model RFC30, RFC43 and RFC49 sprinklers discharge
water in a hemispherical pattern below the sprinkler de- and positively attached and blends into the ceiling, con-
flector. Residential distribution patterns are higher and cealing the most dependable fire protection available, an
generally contain a finer droplet size than standard sprin- automatic sprinkler system.
kler patterns. The RFC30, RFC43 and RFC49 are UL Listed Residen-
The combination of speed of operation and high dis- tial Sprinklers to be installed in the residential portions
charge pattern required for residential sprinklers has of any occupancy in accordance with NFPA 13, 13R, &
demonstrated, in fire testing, an ability for controlling 13D.
residential fires, and thereby providing significant evacu- The RFC30, RFC43 and RFC49 can reduce the need
ation time for occupants. for precise cutting of drop nipples. The threaded cover
The RFC30, RFC43 and RFC49 Sprinklers provide the plate assembly can be adjusted without tools to fit ac-
best form of fire protection by combining an attractive ap- curately against the ceiling. The fire protection system
pearance and '/2" (13mm) of cover adjustment for ease need not be shut down to adjust or remove the cover
of installation. The small diameter cover plate is easily plate assembly.
Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Application and Installation
The RFC30, RFC43 and RFC49, for residential instal- When inserting or removing the wrench from the sprin-
lations, use a 165°F (74°C) fusible solder link in a tun- kler/cup assembly, care should be taken to prevent dam-
ing fork style sprinkler frame with a drop-down deflector. age to the sprinkler. DO NOT WRENCH ON ANY OTHER
This assembly is recessed into the ceiling and conceafed PART OF THE SPRINKLER/CUP ASSEMBLY. MODEL
by a flat cover plate. The cover plate is attached to the RFC30, RFC43 AND RFC49 CONCEALED SPRINKLERS
skirt, using 135°F(57°C)ordinary temperature classifica- MUST BE INSTALLED ONLY WITH 135°F RATED COV-
tion solder.When the ceiling temperature rises, the solder ERS.
holding the cover plate releases the cover allowing the Note:A leak tight Y2" NPT(R1/2)sprinkler joint can be ob-
deflector to drop into position and exposing the sprinkler tained with a torque of 8-18 ft-ibs (10,8- 24,4 N-m). Do not
inside to ceiling temperature. The subsequent operation tighten sprinklers over maximum recommended torque. It
of the solder link opens the waterway and causes the de- may cause leakage or impairment of the sprinklers.
flector to drop into position to distribute the discharging Cover assemblies provide up to '/2" (13mm) of adjust-
water in a hemispherical pattern below the sprinkler de- ment. Turn the cover clockwise until the flange is in con-
flector. Any adjustment of thread engagement between tact with the ceiling. For the push-on/thread-off option,
the cover plate and cup will assure that the drop-down the cover assembly is pushed onto the cup and final ad-
deflector is properly located below the ceiling. The resi- justment is made by turning the cover clockwise until the
dential distribution pattern contains a finer droplet size skirt flange makes full contact with the ceiling. Cover re-
than a standard sprinkler, and the pattern produces sig- moval requires turning in the counter-clockwise direction.
nificantly higher wall wetting. In ceilings that have a plenum space above the
After a 25/a inch diameter hole is cut in the ceiling, the sprinkler,the plenum space may have neutral or neg-
sprinkler is to be installed with the Model FC Wrench. ative pressurization but must not be positively pres-
When installing a sprinkler, the wrench is first positioned surized. Inspect all sprinklers after installation to en-
into the sprinkler/cup assembly and around the hexago- sure that the gap between the cover plate and ceiling
nal body of the sprinkler frame. The Wrench must bottom and the 4 slots in the cup are all open and free from
out against the cup in order to ensure proper, safe instal- any air flow impediment.
lation. The sprinkler is then tightened into the pipe fitting.
Thread Nominal Sprinkler CCP Assembly Max. Max.
Model Size Orifice Temp Ratin Tem Ratin Ambient
SIN g p' g Tem K Pressure
� � Inch (mm} Inch(mm) oF °C °F °C ,F ; p o� Factor psi(bar)
RFC 30
! (RA0611) ��? ��5) 2VE<(g,2) 165 74 135 57 100 38 3.0(43.2) 175(12)
RFC 43
(RA0612) '�Z���15) �/s(10) 165 74 135 57 100 38 4.3(62) 175(12)
RFC 49
(RA0616) '����15) '/,s(11) 165 74 135 57 100 38 4.9(70.6) 175(12)
Note: 1 bar= 100 Kpa
RFC 30
-- - -.....--- ----
Ordinary Temp. Rating
Max. Coverage 165°F/74°C Top of Deflector Minimum
area Max. Spacing � � to Ceiling �nstallation Spacing
Ft x Ft(m x m) Ft(m) Flow Pressure Inch(mm) Type � Ft(m)
GPM(Umin) PSI (bar)
12 x 12(3,6 x 3,6) 12(3,6) 9(34,1) 9.0(0,62) Smooth Ceilings'h to 1(13 to 25.4)
---------- - ---- -- Beamed Ceilings per NFPA 13D, 13R or Concealed 8(2,4)
14 x 14(4,3 x 4,3) 14(4,3) 10(37,8) 11.0(0,76) 13 installed in beams Yz to 1(13 to 25.4)
_.._ _..-— — —... - - — -- -
For Ceiling types refer to NFPA 13, 13R or 13D
2.
RFC 43
Ordinary Temp. Rating
Max. Coverage Max.Spacing (165°F/74°C) Top of Deflector Minimum
area to Ceiling �nstallation Spacing
Ft x Ft(m x m) Ft(m) Flow Pressure Inch(mm) Type Ft(m)
GPM(Vmin) PSI(bar)
12 x 12(3,6 x 3,6) 12(3,6) 12(4,5) 7.8(0,54)
14 x 14(4,3 x 4,3) 14(4,3) 13(49) 9.1 (0,63)
Smooth Ceilings%2 to 1(13 to 25.4)
16 x 16(4,9 x 4,9) 16(4,9) 13(49) 9.1 (0,63) Beamed Ceilings per NFPA 13D, 13R or Concealed 8(2,4)
13 installed in beams Yz to 1(13 to 25.4)
18 x 18(5,5 x 5,5) 18(5,5) 18(68) 17.5(1,21)
20 x 20(6,1 x 6,1) 20(6,1) 21 (79) 23.8(1,64)
For Ceiling types refer to NFPA 13, 13R or 13D
RFC 49
Ordinary Temp. Rating To of Deflector Minimum
Max.Coverage Max.Spacing 165°F/74°C p Instailation
area Ft(m) Flow Pressure to Ceiling Type Spacing
Ft x Ft(m x m) GPM Umin PSI bar Inch(mm) Ft(m)
12 x 12(3,6 x 3,6) 12(3,6) 13(49) 7.0(0,48)
14 x 14(4,3 x 4,3) 14(4,3) 13(49) 7.0(0,48)
Smooth Ceilings Y to 1(13 to 25.4)
16 x 16(4,9 x 4,9) 16(4,9) 13(49) 7.0(0,48) Beamed Ceilings per NFPA 13D, 13R or Concealed 8(2,4)
I13 installed in beams'/z to 1(13 to 25.4)
18 x 18(5,5 x 5,5) 18(5,5) 17(64,3) 12.0(0,83)
20 x 20(6,1 x 6,1) 20(6,1) 20(75,73) 16J(1,14)
For Ceiling types refer to NFPA 13, 13R or 13D
Maintenance
Model RFC30, RFC43 and RFC49 Concealed Sprin- symmetric lever mechanism, maintaining a Teflon-coated
klers should be inspected and the sprinkler system Belleville spring washer and machined brass cap water
maintained in accordance with NFPA 25. Do not clean seal assembly containing no plastic parts. Sprinkler K-
sprinklers with soap and water, ammonia or any other factor shall be nominal 3.0(43.2), 4.3 (62), and 4.9(70.6)
cleaning fluids. Remove dust by using a soft brush or having a'�jg , 3�g and �/,6" orifice. Temperature rating
gentle vacuuming. Remove any sprinkler cover plate as- shall be Ordinary 165°F(74°C); cover plate temperature
sembly which has been painted (other than factory ap- rating to be 135°F(57°C). Cover plate assembly shall
plied) or damaged in any way. A stock of spare sprin- consist of a brass cover plate and copper alloy retainer
klers should be maintained to allow quick replacement flange allowing a'/z" cover plate adjustment. Any secure
of damaged or operated sprinklers. Prior to installation, engagement between the cover plate and the cup will
sprinklers should be maintained in the original cartons assure that the drop-down deflector is properly located
and packaging until used to minimize the potential for below the ceiling. A plastic protective cap shall be
damage to sprinklers that would cause improper opera- provided and factory installed inside the sprinkler cup
tion or non-operation. to protect the drop-down sprinkler deflector from dam-
age, which could occur during construction before the
MOdel RFC30, RFC43 and RFC49 Residential cover plate is installed. Standard cover finish: [Chrome]
Concealed Sprinkler Specification [White] [Specialty-specify]. Residential concealed
sprinklers shall be Reliable Model RFC30, SIN RA0611
Sprinklers shall be cULus Listed low flow residential con- (Bulletin 006), Model RFC43, SIN RA0612 (Bulletin 006)
cealed sprinklers with drop-down deflector and adjust- or Model RFC49, SIN RA0616(Bulletin 006).
able flat cover plate engineered for a minimum design
density of 0.05 gpm/ft2. Sprinkler frame and deflector
shall be of bronze frame construction having a'/2" NPT
thread. Thermal element shall consist of an approved
black-painted beryllium-nickel fusible solder link with
3.
Ordering Information Cover Piate Finishes�'� �
;
SpeCify: Standard Finishes �
1. Sprinkler Model Chrome �
2. Cover Plate Finish � € �
White Paint �.
3. Thread-On or Special Application � �, �
Push-On Feature Finishes�2� ' ` ��
�
Bright Brass ' �
Finished Bronze
Black Plating ' :
Black Paint �.,; ,
Off White �'"��-- <
Satin Chrome ! '
�'� Other finishes and colors are I � � `�
available on special order. `
Consult factory for details. E �� � �
Coverplate custom paint is =
semi-gloss, unless specified ` -y���� € I
otherwise. 1
�2- For the perforated style cover- I
plate,consult factory for avail- ; ' ��
ability on these and other cus- � � �
tom finishes. j ���
� 3
f 3
E
�'.:_. .:^��
�•X f/Z•RmUC�1eV �
7EE OR EL80W � !
__ �
-- T--��--
,,, ,�,
---�,�-- ,��
---� -t--�_--
, r 2�"[66.SSmmJ
2�"[58.42mmJ DlA N�LE fN CfIUNG
CUP
i 2'[SO.BmmJ A(A.Y.
I FACE OF FlfT/NG
�'[12.70mm] AtAX. ������� TD FAC£ OF CEILlNG
COVER AOJUSTMEM ������� O/MENSlON
�������_ �
_- iiiiiii
1/2'[12.70mm] M/N. TO ' ���/���
t"[?5.4mmJ MAX. C£lLlNC ! �� i i i i i i i
DROPPED D£FLEC70R
TO CEILING i CElUNC
�'[�.96mm]
FL9T COVER PlA7E 3�'[84.?1 mmJ DG4.
/L55EM8LY
SPR/NKLER
COVER PLATE.• 1,��12.7mm� ADJUSTMENT
�,�
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory
'�4ct�:a:RC.:r;rrf-��o�:,�.•rat,r-,o�ot"er:,�V�lar ,�.�:z.,,Icns and also with the provisions of governmental codes or ordinan,..s. t�� �.��� �!::._,t��!F
Prci;..c..� r.i ��=ic�n��d<:.i�'.,t�ib�.�eci::y kc:a:�iE���s3v:�been protecting life and property for over 90 years,and are installF:;<an: ,,��.::,;1 k,r.�t,� ,> ,i;c�.;;
s��jli`:e�i<�ru:•N�>.,t�,:,ie,>�}r�n�c:�-:,c.n.r,�,;1��:;��a€e;i f•roughout the United States,Canada and foreign countries.
1;�td> �a �; i;d
�;:
Reliable Automatic Sprinkler Co., Inc. � `'�'
io..:))431-1588 Sales Offices ��
(t?,�'i.;)848-6051 Sales Fax Revision Ilnes indicate updated or new data.
��;t�l)829-2042 Corporafe Offices
vvv:�.r.�.reliablesprinkler.com Internet Address EG Printed in U S.A. 11/14 P/N 9999970261
Section 2: Pipe Types
�
�
FlameGuard°
� � CPVC FIRE SPRINKLER PRODUCTS
FG-2-0312
Complete System of Pipe, Fittings c� Solvent Cement
�r� Corrosion Resistant • SupeYior Flow � Ease of Installation
�;� ._. Spears�' FlameGuard° CPVC Fire Sprinkler Products provide a cost
�� ; � effective alternative to tnetal systeins with advantages of lligh corrosion
'
���� �� �;� resistance, improved system 1lydraulics, ease of installation and quick
� � �� assembly with readily available tools. CPVC Fire Sprinkler Systems are
�Pf�ff� + t
�,� ��!►��. �����,��,(`���� based on proven
h� � �� "_:J �^.`�.+��`�.I ��� \ : �
cP�c�}��`s����x��R������_� roducts that ���
� :
have been in continuous service for ��� �g
��� � ,�:
over 40 years. Spearsn FlameGuard° n'�" y „ �,. �
L � � �..
�, � �:, � 9
products are approved by UL��' FM�' � � ���' � � ` �
� ��� w���.,. �';� ��
Global, LPCB and Certified by NSF ��� '� �~ �'�'' �.� `
International for potable water use. � � �
��' �', �� �"-
���
Check local codes for restrictions and `�.
���,:; ,-r , . ��,
limitations. � 3 � .� �-.:' _ .�� w� m,�..��..:
,�
Corrosion Resistant CPVC Material Daes Not Easy� Installation for Lower Costs
Sustain Biological Growth FlameGuard�CPVC systein installations significantly
Unlike� metal systems, FlameGuard� CPVC products never reduce costs over conventional metal piping by virtually
n�st,scale or pit and do not sustain biological growtl�-a cause eliininating prefabrication. Systems can be fully installed
of Microbiologically Influenced Corrosion(MIC)which can on site using solvent cement joining methods.
destroy metal fire sprinkler systems from the inside out. UL'$ Listed for U.S. and Canada in
NFPA 13, 13R & 13D Systems
Superior Flow Characteristics for Lowcr FlameGuard� CPVC Fire Sprinkler Products are UL�
Friction Losses
The smooth-wall interior surfaces of FlameGuard� CPVC listed for U.S. and Canada applications for Light Hazard
systems result in reduced friction luss over metal systems. occupancies as defined in NFPA 13,Residential occupancies
The design flow characteristics remain constant throughout up to and including 4-stories as defined in NFPA 13R,
the life of the product because there is no interior corrosion and Residential occupancies for one and two family
in the system due to microbiological activity. dwellings and manufactured home�s as defined in NFPA
13D. Consult Spears FlameGuard CPVC Fire Sprinkler
Pressure Rated to 175 psi (1200kpa) (d; 150°F Products Installation Instructions and NFPA Standards for
(65°C) additional applications including air plenum,system risers,
FlameGuarde CPVC Products are produced in combinations concealed, exposed, underground, combustable attic,
of Schedule 40 and Schedule 80 Fitting configurarions con- garage,basement and low pressure dry piping installations.
fonning to ASTM F 438 or F 439 standards and FlameGuard° L'ull Limited Lifetime WaCCantV
SDR 13.5 CPVC Fire Sprinkler Pipe confonning to ASTM F FlameGuard� CPVC Fire Sprinkler Pt•oducts carry a
442 standai-ds. UL�"� Rated working pressure is 175 psi limited lifetime wan•anty against defects in material or
(1200kpa)@, 150°F(65°C)(LPCB rated to 120°F)(49°C). workmanship. Consult Spears�'warranty for additional
details.
� �``� �"���� PROGRESSIVEPRODUCTSFROM ���`�R',, ���������
s�...,���� SPEARS`'�INNOUATION& ' LPCB9= '� �
�_ �' .w : TECHNOLOGY so oao , �YKASS7
=yZ�x ra����il Visit our web site: www.spearsmfg.com oo;
Spears° FlameGuard°. . . The Leader in Innovative
CPVC Fire 5prinkler System Products
Pioneer in Molded-in Metal Insert Head Adapters
Spears�' pioneered the development of the FlameGuard° molded-in-place a.°
metal thread insert for connection of sprinkler heads to CPVC fire sprinkler ��'' �'�'
systems, plus Metal FIPT threaded female adapters for metal-to-plastic � � _
�� �
transitions. ' � '
,�
Developed the Special Reinforced (SR) Head Adapters
Spears`�� FlameGuard° continuous improvement program developed the �
technology to prodlice a superior patented plastic threaded fitting - the �
Special Reinforced(SR)Design.This unique design incorporates a patented � '
thermoplastic compression process that equalizes stresses generated by ,� � �ry�'
tapered thread joint make-up. All CPVC plastic body and threads provide a '����3� ��,
more uniform construction and improved corrosion resistance. ���:
Now, the Revolutionary TorqueSafeT"" Gasket Sealed
Head Adapter � �
• Requires NO Thread Sealants • Eliminates Stress
• Prevents Over Tightening • Provides Easy Frame Alignment
Spears�' revolutionary design feahires a special molded-in-place Brass � ��;
�� ., '�`a_
Thread Insert fitted with an elastomer gasket seal at the base of the threads. ���o �
The gasket seal allows a modified thread design that eliminates radial stress ���� ���� � ��
and associated problems typical with tapered thread j oint make up. The insert is designed to rotate for easy
sprinkler frame alignment without over tightening. Patent Pending.
Full Assortment of Specialty Products & Fitting Configurations
Spears� FlameGuard° provides the specialty fittings needed in today's fire sprinkler systems. Like the
adjustable drop nipple for fine-ri�ning to finished ceiling height,and ringed head adapter for ease of locating
during installation. Plus, Spears�� FlameGuard�line offers a fu11 assortment of CPVC fire sprinkler fitting
configurations including Tees, Elbows, Flanges, Couplings, Caps, Male Adapters, Grooved Coupling
Adapters and Unions, sizes 3/4" through 3"; with new 3/4" and 1" Repair Couplings.
Complete Size Range of CPVC Pipe
� �r-„-�-,�,c�„���-st �;
Spears'�FlameGuard� CPVC Fire Sprinkler Pipe is available "
in sizes 3/4" to 3". Conforms to ASTM F 442 standard for �,,,_ �� ������������",, �
SDR 13.5 CPVC pipe.
Spears�' Solvent �ements & Thread Sealant
FlameGuard�products sllould be installed using Spears�' FS-5 One-Step Solvent Cement. For threaded
joints, use Spears�' BWE 75'" Thread Sealant that has been tested for compatibility with FlameGuard�
CPVC Fire Sprinkler Products. Spears R'TorqueSafeT"' Gasket Sealed Adapter requires no sealant.
Consult sprinkler head manufacturer prior to use.
Installation Training Available - Contact Spears�' Technical Services for Details
FlameGuardo Products must be installed in accordance with Spears"CPVC Fire Sprinkier Piping Products Installation Instructions,National
Fire Prot�ection Association Standards 13, 13R, 13D,and in accordance with local codes.Code requirements and field conditions may differ.
It is the responsibility of the instatling contractor to insure that the product is suitable to meet these requirements.
SPEARS�' MANU�ACTURING COMPANY v <<.
CORPORATE OFFICE ::� -,
������ 15853 Olden St., Sylmar,CA 91342 • PO Box 9203, Sylmar, CA 91392 �
(818)364-1611 •www.spearsmfg.com '`�.,, ,�;="'
�O Copyright 2012 Spears�Manufacturing Company. All Rights Reserved.Printed in the United States of America 03l12. FG-2-0312
Section 3: Pipe Fittings
�
�� � FlameGuard° t�uickTorqueTM
Gasket Sealed Sprinkler Head Adapter
�� � �� FGQT-2NP-0814
.
- u eckTor ueTM # � ,
q
- � The Qne Head Adapter
That Has 1t ALL!
-� Spears° New FlameGuard°QuickTorqueT'" CPVC
�,�
:�� Sprinkler Head Adapter uses a combination
� �
-=;� � ��� � of high-strength materials to provide the most
;,� �_ ��� � reliable, worry-free adapter in the industry:
���
Y"���x a��°`' CPVC Body for Unsurpassed Corrosion
Resistance
High grade EPDM Gasket for Reliable Sealing
Metal Thread & Exterior Reinforcement for
Superior Strength
The thread design and gasket seal eliminate radial
stress found in tapered thread joint make up, the gasket
compresses to allow sprinkler frame alignment without over
tightening.
4235-130GMR Metal Stainless Steel
✓ Metal Thread Eliminates Cross Threading Threads� Reinforcement
� �i�
✓ Requires NO Thread Sealant �� f
�
✓ High Grade EPDM Compression Gasket �=`
Allows Quick, Easy Head Alignment
Sealin One
✓ Easiest Installation, Finger Tight Plus g Piece
1-Turn Then Align Sprinkler Head! Gasket CPVC
✓ NSF� Certified Lead-Free for Use in Body
Potable Water Systems — Suitabie for Use
in Multi-purpose Systems
QuickTorqueT"" Female Sprinkfer Nea�
Adapter-Gasket Sealed Metal Thread Style,
Prog�essive Products Fro�z Spears� Innovation & Technology
....— .: � ....� .N-
� _'�
'i '
.. {�� __ .:.:7 ,''"' ...
.,.
� Y t . _'�,. _ ,.--..�::� ,.
. . � � � . . ..r
�
�� e
��.... �� '.-�'. _...
4 y.--�'"
� ,, „-
:-,.f � �,.. -., {�,\ ���y
�-:�� _ . ,�� i � '
��
�7""5 `� ����'�' 4,: �� �:_-..
E :ia.er._x�.y.� �,..,,� � �
�
a�i' t � �`- . —'�
+r.--..4 ., . .�i
�� � , � _
DO NOT USE THREAD SEALANT � �'��� / ' � � \�
� �� � �
.'�l� . �
A ry� )��y�T.� ..���
m � ` Y'--{' ��`�..,�
r
x £
�' � 4'tJ?y:
.:' _'.., ..::yyA, � ...w /,�s"—�.�—�—
'! _�_�
�+� � Tighten One Additional Turn Using Wrench
Hand Tighten Only
EPDM Gasket
Metal Threads
Gasket Sealed
� �
._--'``'� � _ .
Align Sprinkler Head 1� -
Horizontally �
_. � , r—�.�.�1"
./'" _. .,,
.(c�"�- �- �'� .�-�-�->=- � '
ik'�
��' �� '._
� ���,�'Y^� �
��� -�� .-''��� tf�� .. �"'—'\... ���� �'��.� �;.t ->��.
�
. .,. � �. .,.."w� � , �
r �
�4 V m.:....� . t
, ,.
°: l .. ..... -�.
�> � � � � ,
� •+# � . `
., �, .;;,
: �� �
� <R,,.�
�,u�'
I�"__���
Align Sprinkler Head
Horizontally
�
SPEARS�MANUFACTURING COMPANY�CORPORATE OFFICE ` ��"' � j 4,�
S°���y � 15853 Olden St.,Sylmar,CA 91342•PO Box 9203,Sylmar,CA 91392 ���: �'.;��� _•�
(818)364-1611 •www.spearsmfg.com t;J�` �--��`��
��
0 Copyright 2014 Spears�'Manufacturing Company. All Rights Reserved. Printed in the United States of America 08!14. FGQT-2NP-0814
Section 4: Pipe Hangers
, ,
Model #470 w ,_
� �-�:y
Short Clip -�, � �
� r� �
y�'�
.y.. ,.�^" g.? �'�`"�,
APPLICATION: Support pipe close to ceiling or walL �� �� � �
� ',� } x-F�..`,, 4 s,f�
NOTE: Follow fastener manufacturer s recommended E '`
�� " ..���,,` °:`
shear and pull-out strength when fastening to the structure. ��`-� ��� �-�
, -.�°:"`,
Part No. PS H CL CL1 W Max. Recom. Finish*
� Load (Ibs)
I 4700050PL 1/2 1-3/16 9/16 2-5/8 3-5/8 300 PL
4700075PL 3/4 1-3/8 11/16 2-7/8 3-7/8 300 PL
4700100PL 1 1-5/8 13/16 3-1/8 4-1/8 300 PL
4700125PL 1-1/4 2-1/8 1-1/8 3-7/16 4-7/16 300 PL
4700150PL 1-1/2 2-1/2 1-3/8 3-1/2 4-1/2 300 PL
4700200PL 2 2-7/8 1-1/2 4 5 300 PL
4700250PL 2-1/2 3-5/8 1-15/16 4-1/2 5-12 500 PL
4700300PL 3 4 2-1/8 5-1/8 6-1/8 500 PL
4700400PL 4 5-1/8 2-5/8 6-1/8 7-1/8 500 PL
Conforms With: Federal Specification WW-H-171 (Type 26), Manufacturers Standardization Society
ANSI/MSS-SP-58; (Type 26) install in accordance with ANSI/M55-SP-69.
Model #9 B�
� �.�r�.4 �,��.,� �
Perforated Hanger Strapping �� -� ���u� 4j �+��,�.
APPLICATION: Light duty, residential pipe support. �_ ��r,�� �;�A, �
NOTE: Follow fastener manufacturer's recommended ,., �� � ,� } �,_,���f�.
shear and pull-out strength when fastening to the structure. F � . �
„�..,��;�?� _.
Part No. Strap Ga. L Max. Recom. Finish*
Size Load (Ibs.)
0097524EG 24 10' - 0" 10 EG
Model #107
One-Hole Wrap Around Strap for CPVC Pipe 3/16
APPLICATION: Support horizontal position from Top or Side of beam. .�
I ;
Part No. PS A B Max. Hanger Finish* B ; A
Spacing
1070075EG 3/4 1 2-7/16 5-1/2' EG �
1070100EG 1 1-7/16 2-11/16 6' EG �
1070125EG 1-1/4 1-5/8 3-1/16 6-12' EG 1-' 1/4'
1070150EG 1-1/2 1-3/4 3-5/16 7' EG � �� �:
1070200EG 2 1-11/16 3-3/4 8' EG °s"°
� All dimensions are in inches unless otherwise noted.
� S_ *See page 2 for finish and material descriptions. All material is Carbon Steel unless otherwise noted.
� � 24 Phone: 800-333-0852 • Fax: 800-677-5403
��• www.e rico.com
�
Model #108 ,� B �,
Two-Hole Strap for CPVC Pipe A ' `
��._.._. � �
i ; i
APPLICATION: Support horizontal piping from # �� s �� 1-3/16 �__._
To Bottom, or Side of beam. Retainer dim les ' �' � �
—� P "� �..� __..-�- _ :..� �
secure hanger to pipe during installation. ��;
1/4 (�
�Q�
Part No. PS A B Max. Hanger Finish* °�`m
Spacing
1080075EG 3/4 3-1/8 2-1/8 5-1/2' EG �
1080100EG 1 3-5/16 2-1/4 6' EG '
1080125EG 1-1/4 4-1/8 3-1/8 6-1/2' EG
1080150EG 1-12 4-5/16 3-3/8 7' EG
1080200EG 2 4-7/8 3-15/76 8' EG
Model #109 cQ� 1-3/16 � B � •— „
Side-Mount Strap for CPVC Pipe °'�° � c
APPLICATION: Support horizontal piping from �-- q ��� �
To� or Bottom of beam. Retainer dimples secure
hanger to pipe during installation. 1/4 0
Part No. PS A B C CL Max. Hanger Finish*
Spacing
1090075EG 3/4 2-5/16 1-11/16 2-7/16 1-7/8 5-1/2' EG
1090100EG 1 2-5/8 2 2-11/16 2 6' EG
1090125EG 1-1/4 3 2-3/8 3-1/16 2-1/8 6-1/2' EG
1090150EG 1-1/2 3-1/4 2-5/8 3-5/16 2-1/4 7' EG
1090200EG 2 3-11/16 3-1/16 3-13/16 2-1/2 8' EG
Model #50 �� --�- �b
{� F
Stand-Off 2-Hole Strap for CPVC pipe
` .�J �
APPLICATION: For mounting CPVC pipe to structural wood or ���` ,��
composite wood joists with a minimum 3/8 web thickness. +� �,
....... E'�..*�.,,„
Part No. PS Finish* a
S072A 3/4 Pre-Galvanized
S016A 1 Pre-Galvanized � �L �
S020A 1-1/4 Pre-Galvanized
S024A 1-1/2 Pre-Galvanized
S032A 2 Pre-Galvanized
APPLICATIONS FOR MODELS#107,#108,#109,#50:To support CPVC or Polybutalene fire sprinkler piping in Fire Sprinkler Systems installed per
NFPA 13, 13R,and 13D.Fasten with Hardened Hex Head Screw(s),#10 x 1",supplied.Offset edge for abrasion prevention and added strength.
NOTES FOR MODEL#107:Install with hanger tabs upward only.If installed inverted,with the hanger tab downward it does not function as
a hanger,but as a restrainer.Do not install on the bottom of a beam or under horizontal surface.for these applications,see Model#108.
All dimensions are in inches unless otherwise noted.
*See page 2 for finish and material descriptions. All material is Carbon Steel unless otherwise noted.
Phone: 800-333-0852 • Fax: 800-677-5403 25 ER1���
www.e rico.com
Section 5: Valves
' • r i , �
�
` Fuil Floatin Cla er Assembl F P P I
9 pp Y
� Description
� � �� �;
� The bronze"`swing check valve features a full floating clapper assembly that �� ��e �
provides for a positive seal each time the valve is cycled. This feature improves � >: � " .�
the swing check valves ability to "clear" any debris that may be present in the � � ' �,
water supply. The seat material is NBR which provides for a positive seal even � , �Jx�`
' � ,-
� under light residual pressures. ���� � �� ° �_�' �_ �
�m3 "'�s.,..�,� ,.'�a� _
� .�.
�
�
�
�.. .. .. . '. .�.+.�........ ....... ..a«M.«�.,u...�....�.�....,...e ,.... ,.,.. ..........,n . ..�.� ,.. —,_.,.,,....., ._...: d� �.` .,. :z ��. ��
�
} e
.. : - _^, y� ..� � o.,
� , ,�y.
� . � _ .
F
= Installation Warning Specifications
� For horizontal installation only. The DO NOT OVER TIGHTEN. Over
� female by female swing check valve tightening during installation will Valve Body:
Cast Bronze'
? should be installed in accordance crack the valve body. Evidence (85-5-5-5)
with commonly used installation of overtightening may not be
practices for the fire sprinkler industry. readily visible or apparent upon Clapper Assembly:
Forged Brass
Proper seal of the threads can be pressurization.
accomplished by applying a liberal Seat:
amount of PTFE based thread seal- NBR(Chloramine Resistant)
ant such as PipeFit�Thread Sealant Sizes
Paste or PTFE Tape. Never use tape �h" IPS
and paste together. This will cause 2" IPS
excessive stress on the threaded Female by female
£ connection leading to failure of the Rated Pressure:
valve. Do not exceed one full turn 250 psi
past hand tight when installing male
'Contains lead.Not for use in
threads into the check valve. water systems intended for numan
consumption.
i
�
3198 LIONSHEAD AVE
CARLSBAD, CA 92010
� TEL+1 760 599-1168
+1 800 344-1822
FAX+1 800 344-3775
O 2012 Fire Protection Products,Ina
i� r� �r � � � r
Section 7: Misceilaneous
3MTM Fire Barrier Sealant IC 15WB+
� . . : � - . . . . .
Regulations and Industry Standards
MSDS (US OSHA)
See Material Safety Data Sheet(MSDS)for hazard and other regulatory data.
EU REACH
This product is a chemical preparation under Regulation No 1907/2006 of the European Parliament and the
Council concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH). To the
best of its knowledge, 3M has pre-registered and has registered/is intending to register all substances of its
chemical preparations that it currently imports into and/or manufactures in the European Union that are in
scope for(pre-)registration by 3M. It has a required safety data sheet.
EU RoHS
This product does not exceed the maximum concentration values (MCVs) in EU Directive 2002/95/EC
(Restriction of the Use of Certain Hazardous Substances (RoHS) in Electrical and Electronic Equipment), as
amended, and/or the MCVs set under EU Directive 2011/65/EU (RoHS recast), as stated in Annex II to that
directive. This which means that each of the homogenous materials within this product does not exceed the
following MCVs: (a) 0.1% (by weight)for lead, mercury, hexavalent chromium, polybrominated biphenyls or
polybrominated diphenyl ethers; and (b) 0.01% (by weight)for cadmium.
Persistent Organic Pollutants (POPs)
This product does not contain a substance(s) present on the Stockholm Convention on Persistent Organic
Pollutants (POPs),Annex A, B,or C retified 8 May 2009.
Lacey Act
As a company committed to compliance and sustainability, a standard part of 3M's supplier practices and
arrengements is to require its suppliers to comply with all applicable laws affecting the manufacture of
products for 3M.This includes the U.S. Animal and Plant Health Inspection Service (APHIS) Lacey Act
amendments of May 22, 2008.This product does not contain does not plant based material and as such is
exempt from the Lacey Act.
Conflict Minerals
"Conflict Minerais," which the U.S. Securities and Exchange Commission ("SEC") has defined as gold,
columbite-tantalite(coltan), cassiterite, wolframite, or their derivatives (tin,tantalum, or tungsten), are not
contained in and are not"necessary to the functionality or necessary to the production"of the above-listed
product, as the term"necessary to the functionality or the production"is defined under the SEC's Conflict
Minerals Rule. 77 Fed. Reg. 56274 (Sept. 12, 2012).
Chemicals and/or Compounds of Interest
Arsenic and (As) compounds :This chemical or chemical compound is not intentionally added.
Asbestos :This chemical or chemical compound is not intentionally added.
Cadmium and (Cd) compounds :This chemical or chemical compound is not intentionally added.
Chlorinated polyethylene :This chemical or chemical compound is not intentionally added.
Chlorofluorocarbons (CFCs) :This chemical or chemical compound is not intentionally added.
Chloroprene (Neoprene) :This chemical or chemical compound is not intentionally added.
Chlorosulfonated polyethylene :This chemical or chemical compound is not intentionally added.
Chromium and (Cr) compounds :This chemical or chemical compound is not intentionally added.
Colophony (Rosin) :This chemical or chemical compound is not intentionally added.
Creosote :This chemical or chemical compound is not intentionally added.
Epoxy compounds :This chemical or chemical compound is not intentionally added.
Flame Retardants (not PBB or PBDE) :This chemical or chemical compound is not intentionally added.
Formaldehyde :This chemical or chemical compound is not intentionally added.
Halogenated Flame Retardants :This chemical or chemical compound is not intentionally added.
Hexavalent Chromium and (Cr+6)compounds:This chemical or chemical compound is not intentionally
added.
Hydrochlorofluorocarbons (HCFCs) :This chemical or chemical compound is not intentionally added.
Lead and (Pb) compounds :This chemical or chemical compound is not intentionally added.
Mercury and (Hg) compounds :This chemical or chemical compound is not intentionally added.
Natural Rubber Latex :This chemical or chemical compound is not intentionally added.
Ozone Depleting Chemicals(ODCs) :This chemical or chemical compound is not intentionally added.
Pentachlorophenol :This chemical or chemical compound is not intentionally added.
Petrochemical fertilizers :This chemical or chemical compound is not intentionally added.
Phthalates : This chemical or chemical compound is not intentionally added.
Polybrominated Biphenyls (PBB) :This chemical or chemical compound is not intentionally added.
Polybrominated Diphenylethers (PBDE) :This chemical or chemical compound is not intentionally added.
Polychlorinated Biphenyls (PCBs) :This chemical or chemical compound is not intentionally added.
PVC(polyvinyl chloride) :This chemical or chemical compound is not intentionally added.
Radioactive Substance:This chemical or chemical compound is not intentionally added.
Selenium and (Se) compounds :This chemical or chemical compound is not intentionally added.
Disclaimers:The information provided in this document related to material content represents 3M's knowledge and belief,
which may be based in whole or in part on information provided by suppliers to 3M.This is intended to answer commonly
asked questions about 3M products and is not intended to be a comprehensive listing of all substances that may be of interest
or that may be regulated in this or other 3M products,nor is it intended to be a comprehensive summary of any and all
regulations that may apply to this product.Where substances are listed,their listing does not infer or constitute a judgment as
to their safety environmental or health impacts.Information is supplied upon the condition that the persons receiving the
same will make their own determination as to its suitability for their purposes prior to use. Customers are encouraged to
consult with leqal and requlatory experts to determine applicable requlations in liqht of intended use of the product.
Limitation of Remedies and Liability: In the event any Product is proven not to conform with the information in this
document,then to the extent permitted by law, 3M's entire liability and Buyer's exclusive remedy,will be at 3M's option either:
(i)replacement of Product with a conforming product,or(ii) refund of the purchase price paid by Buyer for each non-conforming
Product,within a reasonable time after written notification of said non-conformance and return of said Product to 3M. 3M shall
not under any circumstances be liable for direct,incidental,special,or consequential damages(including but not limited to loss
of profits,revenue,or business)related to or arising out of this certification, including,the use,misuse or inability to use the
Product. Unless stated otherwise in writing,the foregoing language cannot be waived, modified,or supplemented in any manner
whatsoever.
Industrial Adhesives and Tapes Division �03M 2014
www.3M.com/regs Printed: 31-Ju1-2014
�, �� �
;�.
> '
� � �_ z �
'y�3 ,;- f
?:; �.
�
��. �
.�� �� , ` _
�
� .
�
a � _.. . ._
�
� x:
�-::�.9,�
.���
,..,, :... � �..4� �H� . . . . ��
��a;,��. �� , . "
�. t
��
j ,z '
,�, . �. ��; �
� `' � ;
� : ���.�
�' .. ?�. ��.", _ , .
, �^
. .. :� .: . . .� ..
_�°. ,� �...�4€. .. .. , . ,�.s s�� ���,_ , :�:� � . _:�.��A; ;�a.
?:�.
�
ST$7EM CQMPATIBLE
' ; , _. : -�.; ' :
.w�s`�a;��.�`�:ur.��:..��.-s�:�-i._. . ..,:3 „.. . ' '"„�' ��,>rs�,:,,��a....,��..�.�i,���;.a�� .,, ::: . .. . ' Y��s.;3�� �� �����
• .:� �, a..�� '; �?.__', ::��- :
s :,�'
'�?^ : �... .: :. �.
�4:
� � FireFic�i�t�r fi�i��38 is a tioi�-toxic;giycerii�e-based antifreeze for use i�j all ty�ae�o€
r �et fire spri��kler- syat��as, incl�dinc� CP4�C. Fire�ic�l�ter GL48 is fa�tary pre-mixed to
s�n NFPA guicleli€�e� of a 48�o c�lycerii}e s�luti�r�. All fire sprifz�Cler systems utilizir�g
�;' �' Fi��eFic�l�ter G��3c� s��oulc3 co��for�r�to lr�cal, stat�, a�ic� E�iFPfi� r�c{vire����i�ts. The us� of
��.�� �ryti�r�eeze °+�iff�ii� t3t�se s ste;��� �4t�uld ciso «��fcrna to NFPA re viremei�fs.
�,' y � q
�,� �
i
�
fi
�^� ���;: � �
� :
�.....
�� �,
� . . � � �� .. . ... ..
,i
��• � � ��
�"
�ns�allatic�r�: 5�stem �tequirenr�+�nts,
• Evacuate al( wat�r frc�rn syzter�� a��d dre�itx dro�s accordiiag�o (.111'�I�'C��IO11$ +�t �qU�IClC1S:
i*3FPA rec�vire�=.enfi�,
• �ireF€g�f�ter GE�8 sf��oa.�(c� be se�te��rior�o introcPutsion lnfo A?l#ire pretecrio��sprF��kler syster�is thz�t use Fire�fgi�ter C�L�8
�I�e s�ste��,. sl�c�u�d confarna to ioeal,s3nte a��d t�lEP,�,requiren�ents.TI-�e use
• aa r�ot diVu=e or add ea3;centrate to FireFigltt�r Gi.48 of cai�ti€reeze v.•ittii��these systenis sl�ould aiso cor�form ta NFPA
• Aft�er fi�l[i�ir,th�sy�tas�f,follo�.��t°�iFP�.guiceEis�es#Qr testing t1s�e requiret��a��+s.
anti�reeze.F9uid sar���xles s�jo�(d be ta�ted �ron3 a n�inimurn af�
fai�h �oint and Ea�.v poEnt,und sl�puld E�e co�az�arabie to k�otf� l3se of� antifE�eeze solutEoi�s shoulc! ulso be i��ccri�faarrnance with
eacl�other and tc�t�e sarr�ple of t'see flui�;t�siec� prior to any state or Incal liecaltl��c�ades. Please contact your tcrcnl
iriror�uction into the syste�n. h�alth authcsrities'sf you have a�zy questions<ancerning the
• Pt�PA rec�uir�s a tag so be crffixed to tl�e riser 1�zdicating t1�e codes in your�m•e�.
dcrte te�ted or replaced,the type and toncentrcatior� by volut�7e
of fluid used,�yst��n ca�cacity �`snn valu€�iej,contractor �zamc ar�d Chem��cals vrEilc�r�anipose FireF�gf�ter GL48 can brs�lc do.;���
facerase izun�(�er,ai�c! c� staren�e��t in�ficat'd��g i�the erit�ire svstem o�ar time. N�AA 2�reqvires thatr t}��� freeairsg po€e�t of t[7e
wcrs drainec! and reple�ced ��itl�anti#reeze.Tags are availpble syste���sfrtoulc4 !ae tested at least oiice a year. Periadic tasti�ig
free of cl�arge fro�ia Noble Cor��paE7y or your lo�a! FireFigttter of syste��is is critical to m�if�taini3ig t4ie proper cone�ntratian
distributor. and freezE �oi��t of the flu#d. Leaks, pressure surges,ar�d
tgr�iperature cl�anges to tfie syste��?casi cause a��tifreeze ta
flo:+- aut of tf�e systen;or wcster to flow fnto the systeni
��'S��tl'1 �E'UtE�.'C�IC?t'E: changing the freeze temperature.
�i,re',Fit�,�r,'�`7�e1' GL4$ ��'�>
Fact�ory�,re-Mix "�
drsrv.s.xn nau . ��w� �. 2. .; � ��^ �,,�'�_� `�
� � :�:
. _ . .... : ..
;,�of Ft�eze F4ow Burst Spsci�ic Gravify '
. FireFighter GE4$ Paint Pcint Poinf ='7°f j�5"C
� 1 CJU � -1�"P -2J�'"F -�t�`'� i.�37 � � ��
F _F f<.�� I��--en���e�,;.a v��Fr�. Yi€.iis�����r; �.,�I#,=n�.in t� f€:,icl_
B ar;?>'oit3'i>n�e t�-ri��e���re�%�e'+ie fluic;ws�1i�3,�xFz rsd::�F�e:i7c3 Frrrstirc�r:ia vessel. ,
Fire�ighrter A+�c�ssori�s:
I" The Fcrlm Abbe re#racta+3jeter is fast,convenient,
I ar}d easy t4 use. SiR��p1y p3ace a di•op or t�o of
fiu€d ic��3e ritaniu��i��•ell aitd press r��autton.The
� custc��i�.desictR�ed micraprocessar is ten�peraiure �,,:
�
'. ' cot�ipensating at7d delivers reudi�tgs for glyceF•i�ie ; �
L �^ ��
anc!pcopylene glycol for both p�rcer7tage�y ;��` ' ��_ �
. a `'�����
vo=urYie and fre�ze poie�t.Ac�are�<y of+,'-.10°��. - - � �f�
f
� _ ., Tl�e Hy�rorreter ar�ea�ures tE�e st�ecific -
' arav9ty of pr�{�ylei�e gPy�c�l and alyceri��e.
'��` Conversio�i t�abies e�llo��the user to
i�=?ea��e�lat� readir�gs#or percei�tage csf �""
a
cancei�tratioE7 'by Yo9un�e ar�d freeze poiast. �
Ir..:luc'es qraduate� c��li��der.
.. .._ � .. � - . ffC.LP�f7+i�t1
... 5ui�'zc+.ir,U8,'It}
�
�. �. . �� '��
� ��- . � ���� � . � � .
�
�t� ����v��ry : . � €� '�- :F�. � ti�"�a ��a�:a:.. C s� ,.�������� " . . s, .�i,a '���1 . . ?'��� �...`��
,w�... .�w�_ „.... .. '�,' ��-,.. . .. .��,�r_ _ . ..��.. . ���a� _ .. ., - .«
�y� P � � � � � � :
, ;
� v_
� � _ � �, � �� a� �� �
� ��� �� _:�� ; ��
a.. �... _ i.
argco.cor-n
�
_
, , , - .
- . .� ������ ��� 12 Hea�l Box
� �,�_
3:
���k... ���
xa � �+y� �.
Y '�
F. � �
� .e�
r9 � I
... . � �� 3.$' 3.32$' O O O O O
5. 1 5 .� � � � � � �
� � � �
� � � 4�
All boxes are made aut z;�• � �4�
of heavy gauge steel ' 'zs°-�'
Knockouts and shelf to & Nedd BOX 6 Large Nead Sox
accommodate any 112"
or- 3I4" heads
A31-welded constructian
and full length hinge
Powder coated red
3 75'
enamel 3.325 625� I
� � � � � � �
5� 1 � � � � � �
Slotted for easy mounting �
with screws, rivets or � � 14„ �3.125"
strapping. � ,a� �2�
Designed to allow for spare sprinkler head storage as required by NFPA guidlines.The Spare Sprinkler Head Cabinets are available in four configu-
rations.Three head,six head,six head ESFR and twelve head.All four styles are manufactured with"knockouts"to accomotlate the most common
size sprinklers.The shelf is located to allow for the storage of a typical sprinkler head wrench.
Each cabinet is finished with a red enamel finish. Each spare head cabinet comes with a hinged door the remains closed to protect the spare sprin-
klers from the elements and features to holes on the back panel to allow for attachment to most surfaces utilizing the approriatefasteners.
Once the correct Spare Sprinkler Head Cabinet has been selected, installation is accompolished by inserting the correct fastener in each of the two
holes inside the cabinet,securing the cabinet securely to the wall.
'�t�.�'� �� �� x;�`;s
,
' Hydraulic Calculations
for
Project Name: Leestma Residence
Location: 3225 Casco Circle, Wayzata, MN 55391,
Drawing Name: Leestma Residence.cad Calculation Date: 4/14/2015
Design
Remote Area Number: 1
Occupancy Classification: Residential
Density: 0.050gpm/ftz
Area of Application: 900ftz(Actual 292ft2)
Coverage per Sprinkler: 100ft2
Type of sprinklers calculated: Pendent
No. of sprinklers calculated: 2
Type of System:Anti-Freeze Volume of Anti-Freeze System: 31.16
Hose Streams: 0.0 gpm at Node: 1 Type: Allowance at Source
Total Water Required (including Hose Streams where applicable):
From Water Supply at Node 1: 34.54 @ 38.221
Water Supply Information:
for Node: 1 Date: 4/10/2015
Location: Casco Circle
Source: Dale Lipovsky
Name of Contractor: Viking Automatic Sprinkler Company
Address: 301 York Avenue, St. Paul, MN 55130
Phone Number: 651-558-3221 Name of designer: Dale Lipovsky
Authority Having Jurisdiction: City of Orono
Notes:
� �� �� � .��� r ��� � �� ��
��� k�h �J
��� ���...�,. �� c CC�.�J C'�D .�-1�L •
�! /���/�5
:^�fJ M.E.P.CAD, Inc. ,`��AutoSPRINKO VR11 v11.0.30.0 4/14/2015 9:18:05AM Page 1
_ :,
Hydraulic Graph
Job Name: Leestma Residence N �.ss
Remote Area Number: Date:4/14/2015
100
Water Supply
Summary Sheet
so Node: 1
so
�o
vailable Supply
Static Pressure 64.000
4.54 @ 63.937
60
N
Q
j �J�
N
N
N
a`
40 4.54 @ 38.221
934.00�36.000
30
System demand curve
20
10
0
0200 400 600 $�� 1000 1200 ��� 1600 1800 2000
Flow-gpm
�M,O M.E.P.CAD, Inc. _,�� AutoSPRINKO VR11 v11.0.30.0 4/14/2015 9:17:OOAM Page 1
�
t-���Summary Of Outflowing Devices ---� JobNumber:125366
'i ti Report Description:Residential
� Actual Flow Minimum Flow K-Factor Pressure Density
Device m m K si m ft2
=�;� S rinkler 101 16.97 16.97 4.9 12.000 0.170g m/ft�
Sprinkler 102 17.57 12.96 4.9 12.857 0.176gpm/ft�
�:> Most Demanding Sprinkler Data
,� O M.E.P.CAD,Ina �,�;�AutoSPRWKO VR11 v11.0.30.0 4/14/2015 9:17:OSAM Page 2
J�ob Name: Leestma Residence
Remote Area Number: Date:4/14/2015
Pipe Information
Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes
Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent
(Foot)
(Q� Fitting Length)
Pf Friction Elev(Pe) Fixed Pressure Losses,when
Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly
Node 2 Actual ID Length Total
(Foot) (Q) (Foot) Foot (PS�) Friction(P� to(P�and shown as a
� 1 ne ative value.
101 21'-10" 4.9 16.97 1 �
See 15'-2Y2" 150 12.000 •••••Route 1 •••••
Notes) Sprinkler,
8'-0" -0.328
0.050231 E(7'-0"),Tr(1'-0")
7 22'-7" 16.97 1.10 23'-2'/z" 1.165
7 22'-7" 17.57 1 (See 4'-5" 150 12.837
Notes) Flow(q)from Route 2
��� � 5'-0��
6 22'-7" °� � 34.54 1.10 9 5 0.187004 1 761 C(5'-0")
a �
6 22'-7" 1'/: (See 114'-7Yz" 150 14.598
Notes)
93'-0" 12.826
5 -7'-0" � 34.54 1.60 207,7�2. 0.030474 6 32� 5Tr(1'-0"),4T(8'-0"),6E(9'-0"),
; �.,.� 2c I 1'-0"
5 -7'-0" 1 Yz (See 2'-2" 120 33.751
Notes) 38'-11" 0.723
�'��
4 -8'-8" ��, ` 34.54 1.6g 0.035366 2T(12'-6'/z'),CV(13'-9Yi')
� -,� � 41'-1" 1.453
:. r .
, See 0'-4Yz" 120 35.927
4 -8'-8" 1/< <
Notes) 0.159
3 -9'-0" w' 34.54 1.45 O,��Z, 0.073428 0.027 BaIV
�,�� ;
3 -9'-0" �+�, (See 100'-10'/�' 150 36.112
Notes) 16'-0" 0.383
2 -9'-11" '°���� 34.54 1.39 116'-10Y=" 0.059264 6.927 2E�8�-0")
2 -9'-11" g (See 57'-9" 150 43.422
Notes) -5.202
0.000023
1 2'-1" ' ����� 34.54 6.98 Water Supply
�� 57'-9" 0.001
��
�;
� ,,.�,
0.00 38.221 Hose Allowance At Source
1 34.54 Total(Pt) Route 1
102 21'-10" 4.9 17.57 1 (See
0'-9" 150 12.857 •••••Route2•••••
Notes) Sprinkler,
5'-0" -0.328
7 22'-7" 17.57 1.10 0.053540 T(5'-0")
5'-9" 0.308
12.837 Total(Pt) Route 2
�,O M.E.P.CAD,Ina �;��AutoSPRINK�VR11 v11.0.30.0 4/14/2015 9:17:07AM Page 3
.1ob N�m�: Leestma Residence
Remote Area Number: Date:4/14/2015
Equivalent,Pipe Lengths of Vaives and Fittings(C=120 only} ��� ::,; y;.;, ; �•Ualue Multiplier
Actual Inside Diameter 4.87 Value Of C 100 130 140 150
=Factor
Schedule 40 Steel Pipe Inside Diameter ) Multiplying Factor 0.713 1.16 1.33 1.51
� �,: � ����`�tUrigs t»sgen��., �
, ,:.
, „�,,, ., �,..
_ ..,,.
ALV Alarm Valve An V An le Valve b Bushin
BaIV Ball Valve BFP Backflow Preventer BV ButterFl Valve
C Cross Flow Turn 90° c I Cou lin Cr Cross Run
CV Check Valve DeIV Delu e Valve DPV D Pi e Valve
E 90°Elbow EE 45°Elbow Ee1 11'/<°Elbow
Ee2 22'/z°Elbow f Flow Device fd Flex Dro
FDC Fire De artment Connection fE 90°FireLock TM Elbow fEE 45° FireLock TM Elbow
fl Flan e FN Floatin Node tT FireLock TM Tee
Gau e GIoV Globe Valve GV Gate Valve
Ho Hose Hose Hose HV Hose Valve
H d H drant LtE Lon Turn Elbow mecT Mechanical Tee
Noz Nozzle P1 Pum In P2 Pum Out
PIV Post Indicatin Valve PO Pi e Outlet PRV Pressure Reducin Valve
PrV Pressure Relief Valve red Reducer/Ada ter S Su I
sCV Swin Check Valve S r S rinkler St Strainer
T Tee Flow Turn 90° Tr Tee Run U Union
WirF Wirsbo WMV Water Meter Valve Z Ca
�+ O M.E.P.CAD,Ina �,��AutoSPRINK�VR11 v11.0.30.0 4/14/2015 9:17:07AM Page 4