HomeMy WebLinkAbout2016-00137 - mechanical CITY OF ORONO � 2 0 1 6 - 0 0 1 3 7 * ' � 2750 KELLEY PARKWAY DATE ISSUED: 02/10/2016 ORONO, MN 55356- (952) 249-4600 FAX: (952) 249-4616 ADDRESS : 1185 FERNDALE RD W PIN : 02-117-23-43-0025 LEGAL DESC : REG. LAND SURVEY NO.0397 : LOT 000 BLOCK 000 PERMIT TYPE : MECHANICAL PROPERTY TYPE : RESIDENTIAL CONSTRUCTION TYPE : MECHANICAL-MULTIPLE VALUATION : $ 29,545.00 NOTE: (1)BRYANT FURNACE (1)BOILER (1)COOLING SYSTEM (2)BATH EXHAUST GASLINE TO FIREPLACE APPLICANT MECHAMCAL 36931 STATE SURCHARGE MECH(VALUATION) 14.77 PRONTO HEATING&AC TOTAL 384.08 7415 CAHILL RD Payment(s) EDINA, MN 55439- CHECK 11568 384.08 (952)835-7777 OWNER WYMAN,JAMES&KATHLYN 1185 FERNDALE RD W WAYZATA,MN 55391- AGREEMENT AND SWORN STATEMENT The work for which this permit is issued shall be performed according to the approved plans and specifications,applicable City approvals,and the State Building Code. This permit is for only the work described and does not grant permission for additional or related work which requires separa[e permits. All provisions of laws and ordinances governing this type of work shall be compied with whether or not specified herein.This permit will expire and become null and void if construction authorized is not commenced within 180 days of the date of issuance,or if construction is suspended for a period of 180 days at any time afrer work has commenced. The applicant is responsible for assuring all required inspections are requested in conformance with the State Building Code.This permit may be revoked at any time for due cause. ��.�-„ �� �'!��'Jfl� lfo Q [ �_ oZ- / /�,� Applicant Permitee ignature Date Issued B ignature Date F R C TY USE ONLY � � City of Orono �7� /- �j �-O�O P.O.Box 66 Date Recei :`� Permit#KV�1�/ /v 2750 Kcllcy Parkway �q�[ � Crystal Bay,MN 55323 Approved By: Amount$:�d"�� Phone(952)249-4600 Fax(952)249-4616 � � ti � F G� t�kfSH��� CITY OF ORONO –MECHANICAL PERMIT (All Commercial permits must be approved by the Building Otticial or[nspector and/or Fire Marshall) GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a pennit will be issued within two working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs—Complete calculations, details and specifications are required for each heating,ventilation,huinidificatioil-dehumidification,and air conditioning installation including heat loss/heat gain calculation,design temperatures,equipment ratings and identification as to type,manufacturer and model. Data shall be presented on form provided. 4. When any new construction or remodeling is involved,a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected(rough-in and final). Call (952)249-4600. (24-48 hour notice required) 7. House Heating Test Record must be submitted before final. TYPE OF PERMIT (Check All That Appl ) [�Residential ❑ Commercial(Approval Rec�uired) ❑ New [�Additional ❑Repairs ❑Replace Job Site / Owner Information: Site Address: ���S �e�`���lc �o�� W��� Owner: Mailing Address: City: � �`�n� Zip: 5�3�� Home Phone: Alternate Phone: Contractor Information: Contractor: P����� I-lf� -�A;r Contact Person: ��a r►�� —� Address: 7y/5 �G�,;II /��tia� State Bond#: �v�$OUyB�Q City: ��'��i Zip:SS y 3`�Expiration Date: (�`f��(�+ Phone: �'I7 2��1�`-1"'S°3v Alternate Phone: (,l z - 7q�- 3��i$ ❑ Insurance–Current: 1 ' ' MECHANICAL SYSTEMS BEING 1NSTALLED Note: All Geothe�-mal Systems will now require a Site Plan&Review by our Building Official. IS THIS GEOTHERMAL? ❑ Yes ��No HEATING SYSTEMS Quantity: � � � D v,�� Make: �:Yti•�'� �V�%Z Model: `1Z�l�'IA3ouy�v�y 7'�T �� Fuel: �� , l�� Flue Size: �� P✓� 2 �UC. InputBTUs: �W�v bb bov Output BTUs: 3`�,��U j 7 c��v CFM: %�C�� °"""' COOLING SYSTEMS Quantity: i Make: ���a„� � Model: ��� j3 Np o t$ Tons: �• S H.Power j- S FIREPLACES � Gas Factory Fueplace Brand Name: Wood Burning Fireplace ❑ Wood Stove Model No.: ❑ Wood Stove with Flue/Masonry VENTILATION ❑ No. Kitchen Exhaust duct recirculating cfm ❑ No. 2 Bath Exhaust(must have duct outside) cfm ❑ No. Other Fans: Locations cfm FUEL STORAGE (Must be approved by Fire Marshall if proposing to abandofa tank in place.) ❑ Installation ❑ Removal Fue] Oil: gallons ❑ Underground ❑ Inside ❑ Outside LP Gas: gallons Other: GAS LINE ONLY ❑ Outdoor Grill []� Other/List What&Where:Gas �,nt -}n F('_ 2 PERMIT FEE CALCULATIONS 1. CONTRACT PRICE * is 1.25%of contract price with a(Minimum Fee of$50.00) 29 SyS X .o12s � 3�`� .�i (contract price) (minimum$50.00) 2. STATE SURCHARGE zg, Sy5 X .000s � � �. 7"� (contract price) 3. POSTAGE&HANDLING(Only on Mail-In Applications) $ 2.00 4. TOTAL PERMIT FEE (Add Lines 1-3 Above) $ �`D y. C�� ■ * CONTRACT PRICE or JOB COST means the actual or estimated dollar amount cha�ged for the pern�itted work including materials, labor, profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material,equipment,labor or installations are furnished by the owner, tenant or any other party, the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event that there is a dispute on the amount of the job cost, the City may request tl�e submission of a signed copy of the actual contract. MECHANICAL PERMIT APPLICATION AGREEMENT The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the State of Minnesota, and cei-tifies that all statements made on this application are complete,true and correct. Applicant's Signature: ��� Date: � —9-I�, 3 �Rhvac-Residential 8�Light Commercial HVAC Loads Elite Software Development,Inc. Pronto Heating and AC � Wyman Addition Eden Prairie,MN 55344 Pa e 1 Project Report General Pro'ect Information Project Title: Wyman Addition Designed By: Doug Dormanen Project Date: 10-23-15 Client Name: Kyle Hunt& Partners Company Name: Pronto Heating &Air Conditioning Company Representative: Doug Dormanen Company Phone: 952-835-7777 Desi n Data Reference City: Minneapolis, Minnesota Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Drv Bulb Wet Bulb Rel.Hum Rel.Hum Drv Bulb Difference Winter: -16 -12.38 n/a n/a 70 n/a Summer: 95 73 36% 50% 72 30 Check Fi ures Total Building Supply CFM: 391 CFM Per Square ft.: 0.410 Square ft. of Room Area: 956 Square ft. Per Ton: 943 Volume (ft3)of Cond. Space: 8,964 Buildin Loads � Total Heating Required Including Ventilation Air: 24,092 Btuh 24.092 MBH Total Sensible Gain: 9,461 Btuh 78 % Total Latent Gain: 2,706 Btuh 22 % Total Cooling Required Including Ventilation Air: 12,167 Btuh 1.01 Tons (Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\1 New House.rh9 Friday, October 23, 2015, 2:17 PM Rh c sidential&Light Commercial HVAC Loads Elite Software Development,Inc. Pronto Heating and AC � Wyman Addition Eden Prairie,MN 55344 Pa e 2 Load Preview Report � , � , , P '' Net; �on, Area Gain� Latl Net Sen H�S Cisi AC{! Duct _ . _.____.�__ ft.2 Sen -_.-_ ___.___ .-_-_-----_— i Gain' Gain Loss 9 i 9 i � Size , i , � CFM� CFM+ CFMi Sco e Ton- _-- �__---- - — ---- .-'— ------------------------ Building 1.01 943 956 9,461 2,706 12,167 24,092 267 391 391 System 1 1.01 943 956 9,461 2,706 12,167 24,092 267 391 391 9x9 Ventila6on 1,105 899 2,004 4,130 Zone 1 -Clg.:42°/a, Htg.: 52% 360 4,099 792 4,891 10,299 138 192 192 5x8 1-Main Level 360 4,099 792 4,891 10,299 138 192 192 3-6 Zone 2-Clg.: 58%, Htg.:48% 596 5,692 1,015 6,707 9,663 129 267 267 6x8 2-UpperLevel 596 5,692 1,015 6,707 9,663 129 267 267 3-6 Sum of room airflows may be greater than system airflow because system has multiple zones. C:\Users\User\Documents\Elite Software\Rhvac 9 Projects\1 New House.rh9 Friday, October 23, 2015, 2:17 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Pronto Heating and AC � Wyman Addition Eden Prairie,MN 55344 Pa e 3 - _ _ _ --� Total Building Summary Loads _ Component Area Sen Lat Sen Total Descri tion Quan Loss Gain Gain Gain 4A-6-o: Glazing-Double pane low-e (e = 0.20 or less), 100 2,838 0 2,119 2,119 high performance, operable window, e=0.05 on surface 2, any frame, outdoor insect screen with 50% coverage, dark color blinds at 45°with 100% coverage, u-value 0.33, SHGC 0.33 12E-Osw: Wall-Frame, R-19 insulation in 2 x 6 stud 1178.8 6,894 0 2,036 2,036 cavity, no board insulation, siding finish, wood studs 16CR-44: Roof/Ceiling-UnderAttic with Insulation on Attic 596 1,128 0 629 629 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic with Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-44 insulation 22B-10ph: Floor-Slab on grade, Vertical board insulation 64 2,647 0 0 0 covers slab edge and extends straight down to 3' below grade, any floor cover, R-10 insulation, passive, heavy moist soil 20P-30: Floor-Over open crawl space or garage, Passive, 236 710 0 149 149 R-30 blanket insulation, any cover _ _ __- ----- — _ _— Subtotals for structure: 14,217 0 4,933 4,933 People: 3 660 900 1,560 Equipment: 0 300 300 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 63, Summer CFM: 57 5,745 1,147 1,409 2,556 Ventilation: Winter CFM: 45, Summer CFM: 45 4,130 899 1,105 2,004 Exhaust: Winter CFM: 100, Summer CFM: 100 AED Excursion: 0 0 814 814 - - -- _ - — --__-- _ __-- - Total Building Load Totals: 24,092 2,706 9,461 12,167 Check Fi ures Total Building Supply CFM: 391 CFM Per Square ft.: 0.410 Square ft. of Room Area: 956 Square ft. Per Ton: 943 Volume (ft3)of Cond. Space: 8,964 Buildin Loads Total Heating Required Including Ventilation Air: 24,092 Btuh 24.092 MBH Total Sensible Gain: 9,461 Btuh 78 % Total Latent Gain: 2,706 Btuh 22 % Total Cooling Required Including Ventilation Air: 12,167 Btuh 1.01 Tons (Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are perFormed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\UserlDocuments\Elite Software\Rhvac 9 Projects\1 New House.rh9 Friday, October 23, 2015, 2:17 PM � � - - Rhvac-Residential 8�Light Commercial HVAC Loads Elite Software Devetopment,Inc. Pronto Heating and AC � Wyman Addition Eden Prairie,MN 55344 Pa e 4 System 1 Room Load Summary _ � Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Clg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Main Level 360 10,299 138 3-6 326 4,099 792 192 192 — - _-- - - -- - —- --- Zone 1 subtotal 360 10,299 138 4,099 792 192 192 ---Zone 2--- 2 Upper Level 596 9,663 129 3-6 453 5,692 1,015 267 267 - _ _ _ __Zone 2 subtotal 596 _ 9,663 129 5,692 1,015 267 267 - _ -- — ----- _ Ventilation 4,130 1,105 899 _ System 1 total __956 24,092 267 9,461 2,706 391 391 - ---- --_— -- - System 1 Main Trunk Size: 9x9 in. Velocity: 696 ft./min Loss per 100 ft.: 0.123 in.wg Note: Since the system is multizone, the Peak Fenestration Gain Procedure was used to determine glass sensible gains at the room and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended to equal the totals at the system level. Room and zone sensible gains and cooling CFM values are for the hour in which the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the"Average Load Procedure + Excursion" method. Coolin S stem Summa Cooling Sensible/Latent Sensible Latent Total Tons S lit Btuh Btuh Btuh Net Required: 1.01 78%/22% 9,461 2,706 12,167 E uipment Data Heatinq System Coolinq Svstem Type: Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 0 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh (`•\I Icoro\I loo�\Il.,..��.,�..,.,+�\CI:�.. C..F+..,.,�,.\oh.,...,n o�.....,.a..�� ni.....i�_..-- -�n �--'--- ^-`-'- - - .... .....� .. .-. .-... ;��a �_'� � ;�� :_ c�. � 5 �-. . �'-.�. �4� :�� � ���y' � �� � .-�y, ___. _ .-:�:_-— — - `�., ' < _ ---- ___ -____a= �� �r`; � r� e— 1.� �§ �. � � ,� '. } _ � .�;�, i; � � �, � � i,r� ��_} � � J, ; �1 � � Q � o � � 4�3 Q 2� � �-0- } � p O � � � �'�+,�' , �- il � � � .�__." � � � � : _ � . . _. I _ __ _ ._ _:�; � -� « �. �f � -� � � � � � �o �•> �� < � '�— � .� �,. �, � "� �� ~� � I� � � �� i �� ��. \y +o, '-� � � �# ` ,y � ' - . � } �� ,`=� �� ,� � - � --� �. CJ � � � � --� ._ _�' _. � � �,�Q Q Q � � � c � � ,Q � Z � F V � � � r � � � �' J na ^� °� � � � � j` 1 a �*� a � '� '� � O .� '� a � � �_ � � - - - - � � ° s!� � � i � � � , .. ro � ,� � � `.F � � 13' ;, � _ ._ — — — __ � � '° � � � - � 2 � �. � ,. � � � � ��� � — --_ � � � � w � � � o � � L ' s,,�. N a '� � � � `� � g � �" � � _ � � � � �' U � � � .� � .v � n � � � � � � � .. � `� � � g x � � � - - o-- - � _ _ C�7 � ,� ,e . t� � �� � .o ;. _, . . R . . �. a � � ..a ' S � � �° � �i � � ro L � �") � � � � � � -�- — C�C` a � � � < � `' -: C� �O .� � � � , � � .,R � �, � . �� y � '�� �' � ,,, ='�� P�� d� . � � � � � � .�� � ��Y � ti o � � � � � �n �fi� � '' '��. LLI •�' -�....,.� L �� .�' R o c� � y 4 � � � � �, °� �� � _ ._ _ _ -- __.. � � � � � -� - - � � � o �' � „ � :� � � � Q � y ,. 3� G ___. _ ..__ � � t., �, 4+ - - � � �` .�- � � � � � �, --- - - - __ __ � � �� � �' - - � � � U � � � �� � � �� � 'a � � � � � � �� ¢ �� y � � � °� 4, 'll � � Q � � � �� � � r �• � � � � g � � �r � $� � � � D �'Ra a � � � � � i� � V � � _. .. __�__.___-. _.�.... . _.._ _ .. -.__. .� . . . .�_ J _ � x U i Q `<� DATE T� CITY OF ORONO CALLED IN a'/D -�b INSPECTION NOTICE SCHEDULED Ql-/ a-/b ,'/:�� PERMIT NO.�d� L ��37 COMPLETED ADDRESS �l �� %����� �d OWNER T PHONE N0.9��"����3b CONTRACTOR �^�L `� � DESCRIPTION ��G� ��- � ly ❑ FOOTING ❑ DEMO-FINAL ❑ SEPTIC FINAL Q ❑ POURED WALL ❑ PLUM RI ❑ EXCAV/GRADING/FILLING Q ❑ FOUNDATION WATERPROOF ❑ P MBING FINAL ❑ TREE REMOVAL Z ❑ RADON SLAB MECHANICAL RI ❑ SITE INSPECTION Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ RATED WALLS � ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP W ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ FOUNDATION/REMOVAL _ J ❑ DEMO-SITE ❑ SEPTIC INSTALL 2 OWNERICONTFiACTOR TO MEET YOU:_YES_NO c��, COMMENTS: W ' a � J -- O �. � � O � , W CC \ Q N ____--- /_ ,�G, l �� � DATE TIME �� CITY OF ORONO CALLED IN ��� INSPECTION E SCHEDULED PERMIT NO. ����'3� COMPLETED ADDRESS 1 � g � �t�/�I'lOIG7�P��(.,) OWNER TELEPHONE NO. '�/�J"�a 7 y y"�O CONTRACTOR ���L� T C��1��%� � DESCRIPTION �r ' � l� ❑ FOOTING ❑ DEMO-FINAL ❑ SEPTIC FINAL �-� Q ❑ POURED WALL ❑ PLUMBING RI ❑ EXCAV/GRADING/FILLING Q ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL Z ❑ RADON SLAB ❑ MECHANICAL RI ❑ SITE INSPECTION� Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ RATED WALLS �i� � ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT ( Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP '��73� _ ❑ AS BUILT-SURVEY ❑ S ER HOOK-UP ❑ FOUNDATION/REMOVAL v ❑ DEMO-SITE ❑ PTIC INSTALL � OWNER/CONTRACTOR TO MEET YOU: YES O v�, COMMENTS: � W C � � O ` � O � W � Q � 2 W � W � j d W ❑WORKSATISFACTORY:PROCEED JECT COMPLEfE � ❑CORRECT WORK 8 PROCEED ❑ ISSU CERTIFICATE OF OCCUPANCY W O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORE COVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. � pHOTO TAKEN INSPECTOR WFLL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR �CITATION ISSUED - " ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Cail for the next inspection 24 hou ' ance. �9 2 9-4600 OwnerlContractor on site: Inspector. White Copyllnspector's File Canary CopyfSite otice .�_�. s�� �f DATE TIME CITY OF ORONO CALLED IN �� INSPECTION NOTICE SCHEDU�ED � Fj-(-6 l0: G�� PERMIT NO. o�f�l L GL I�7 COMPLEfED ADDRESS �— `� `�-5 r�h,G1 � ��_ �GY OWNER TEL��P�QNE NO. � CONTRACTOR �� OV � � � DESCRIPTION � �-t't- �J k1 ❑ FOOTING ❑ DEMO-FINAL ❑ SEPTIC FINAL Q ❑ POURED WALL ❑ PLUMBING RI ❑ EXCAV/GRADING/FILLING Q ❑ FOUNDATION WATERPROOF ❑ PLUMBING FINAL ❑ TREE REMOVAL Z ❑ RADON SLAB ❑ MECHANICAL RI ❑ SITE INSPECTION Q ❑ FRAMING ❑ MECHANICAL FINAL ❑ RATED WALLS � ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP _ ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ FOUNDATION/REMOVAL v ❑ DEMO-SITE ❑ SEPTIC INSTALL 2 OWNERICONTRACTOR TO MEET YOU:_YES_NO � COMMEN � �4��o.c� 7i�6.-�S {✓ ,(�4��C r.ca...� eF � � �Gtt �ry - ¢.i �� o,��r ,.�,��--���6�� — �. � � ^ �rpr�4Q {�vc�.�. (L�-3 /�rS�cG • �c�✓ L�..=s W /- �'' / -�, � '�/d N� ,C10 t�!�' �Q ,�l iG+�.. �- Q � Z . �W ��/��G� � 0 k �S Cv`r��-TG�¢ � j d W� ❑WORKSATISFACTORY:PROCEED ❑ PROJECT COMPLEfE RECT WORK 8 PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY O ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORECOVERING PERMANENT ❑CORRECT UNSAFE CONDITION WITHIN HOURS. ❑ pHOTO TAKEN INSPECTOR WILL REfURN ❑CITATION ISSUED ❑STOP ORDER POSTED.CALL INSPECTOR ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Call for the next inspection 24 hours in advance. (g52) 249-46�� Ownerl ontractor on si �' Ii�GJ Inspector. / White Copyllnspector's File Cenary Copy/Site Notice � I �- � �� � . � J �� DATE TIME � CITY OF ORONO CALLED IN —�,�—� INSPECTION NOTICE SCHEDULED _J� � r �•�t" PERMIT NO. �-�'�(� �C'/��cornP�erE� ADDRESS � � �� f���'�/�c��l� �c'� l�/ OWNER TELEPHON �j a -� � 7 �'3 C� CONTRACTOR ,, Y7;'YI�l=� �tC/C�7�� ��^ ' �% � DESCRIPTION �� / ��� �r��� l� ❑ FOOTING ❑ DEMO-FINAL ❑ SEPTIC F1 AL , Q ❑ POURED WALL ❑ PLUMBING RI ❑ EXCAV/GRADING/FILLING Q ❑ FOUNDATION WATERPROOF ❑�P��LUMBING—FI AL ❑ TREE REMOVAL Z ❑ RADON SLAB C�VIE HANICA ❑ SITE INSPECTION , Q ❑ FRAMING MECHANICAL FINAL ❑ RATED WALLS � ❑ INSULATION ❑ WOOD BURNER/FIREPLACE ❑ COMPLAINT Q ❑ FINAL ❑ WATER HOOK-UP ❑ FOLLOW-UP _ ❑ AS BUILT-SURVEY ❑ SEWER HOOK-UP ❑ FOUNDATION/REMOVAL J ❑ DEMO-SITE ❑ SEPTIC I TALL 2 OWNERlCONTRACTOR TO MEET YOU:_YES�NO � COMMENTS:�-T r�y� �� `( I I � �=�l�-`-_'f'� W a o �'j'f�i�•�•� G2Vb� ' � 16�0�✓L'V �Bl/�/� /.evr��Q� � � — s c��� r�t c���t�� �4��C c��.S� �,L — 0 � � j'174/C� du✓ G�/' r � k• �D Q ZP�/"�its � � ` 4�1C¢ D� LL B W � � s� CS� 3 a W ❑WORKSATISFACTORY:PROCEED ❑ PROJECT COMPLETE ��ARFI�CT WORK&PROCEED ❑ ISSUE CERTIFICATE OF OCCUPANCY 0 ❑CORRECT WORK,CALL FOR REINSPECTION TEMPORARY V BEFORECWERING PERMANENT ❑CORRECTUNSAFECONDITIONWITHIN HOURS. O PHOTOTAKEN INSPECTOR WFLL RETURN ❑STOP ORDER POSTED.CALL INSPECTOR O CITATION ISSUED ❑INSPECTION REQUIRED.CALL TO ARRANGE ACCESS. Ca11 for the next inspection 2a hours in advance. (952� 249-4600 OwnerfContractor on site: f/��� Inspector. � �-- VYhite Copyflnspector's File Canary CopylSite Notice