HomeMy WebLinkAboutSeptic System Inspections � o�
O ,;,.
0 CI'TY OF ORONO
�
Municipal Offices
r��), ,��`�� �� Street Address Mailing Address:
� G 2750 Kelley Parkway P.O. Box 66
'Z� �y Orono, MN 55356 Crystai Bay,MN 55323-0066
kESHO�
To: The Current Owner of Address 2135 CARRIAGE LANE
City Ordinance requires that onsite sewage treatment systems in Orono be inspected on a
periodic basis. The onsite sewage treatment system at the above address has been inspected and
the following is known about the system. A sketch of the known components of the system is
available for most properties at the Orono City Hall.
Imminent Public Health Threat
Yes �No
If yes, please contact the Onsite Systems Manager at 954-249-4626 within 10 days of receipt of
this notice. The septic system must be brought into compliance within 90 days. Failure to do so
will result in referral to the City Attorney for legal action.
System Identified as Non-Compliant
Yes --�_ /
No Z
If yes, system must be brought into compliance by:
December 31, 2007
December 31, 2010
Other
Septic Tank(s) Pump out Needed
Yes �No _
The city recommends the septic tank(s)-and/or lift tank be serviced and umped out every three
(3) years. City records indicate the tank(s) were last pumped out on �- d��07
The tank(s) should be cleaned through the manhole and not through the inspection pipes, this
allows for proper cleaning. .
Comments: __ ._ ._. _ __.. . _ . __
a����
Inspector: Date of Inspection: ����
Telephone (952) 249-4600 • Fax(952) 249-4616
www.ci.orono.mn.us
� °�
0 0�,�
( =;£r� r,�:�,: _ ��� CITY of URONO
11, r3 ,1$�� �� _ �r
�' ,�°bG d "` fY J A7unicipal Offices
�� ������ ���� � �
\��,t � � '�����G Street Address: �15a'a4q'�I6o � Mailing Address:
\��ESH�4 2750 Kelley Parkway P.O. Box 66
� Orono, MN 55356 Crystal Bay, MN 55323-0066
To Current Owner: Address: � ��� �L� !'l�,A,.P LA�1f?
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below.
SYSTEM CONFORMIT`Y (1-3): �
1 "CODE SYSTEM" An ISTS which meets all the location,design and cons�uction standards of the cuirent Orono Municipal Code.
2 "COMPLIAI�TT SYSTEM" An ISTS which does not meet all the location,design and constrvction standards of the current Orono
Municipal Code but does meet the three foot sepazation requirement or two foot requ'uement for systems installed 1996 or earlier,and
which is not failing or an irrnn;nent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an lSTS located within a designated 100-yeaz flood plain,any ISTS which may
or may not meet all the location,design,or construction stan�rds of the current Orono Municipal Code and which is failing for any
reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics.
TANK CONDITION(5-7): S
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years.
Tank was last pumped ).
Make sure septic tanks are pumped throu�h manhole and not throu�h white inspection pipes. This allows for the proper
cleaninQ. Keep water softner and iron filter dischar�e out of septic sVstem to prolon�life of drainfield. Ask pumper to test
alarm float to verifv alarm is still worl:ina in vour house. The alarm warns owner that septa�e is about to backup into basement.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD CONDITION(8-10): �
8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacing,not critical yet.
10 Drainfield'.s saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately.Repairs must be completed within 90 days.
COMMENTS:
<p- i y -�� �(sC.d�'C� ��.
Date of Inspection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requ'uements for a mortgage or other transfer of property,be advised that this report does
not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current
conditions based on the available informarion.
� o�
i`I O�_V. O
� �� CITY of ORONO
''`;� ���a�'"j��-� ; �,��
� � ,
��A�'i,� ;�,,�����;.��!�� ,�lS��'� Municipal Offices
"�'4`�?'��`��� G Street Address:
�9 � • 4� Mailing Addrtss:
k'EggO 2750 Kelley Paricway P.O. Box 66
Orono, MN 55356 Crystai Bay, MN 55323-0066 .
To Current Owner: Address: a� 3 S C`'��r' ��o�� t-.o,�Q_
City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every tr�-o years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the cate�ories checked below.
SYSTEM CONFORMITY (1-3): I
� "CODE SYSTEM" An ISTS which meets all the location,design and construction standards of the current Orono�tunicipal Code.
2 "COMPLIANT SYSTEM" An[STS which does not meet all the location,design and construction standards of the currrnt Orono Municipal
Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and which is not failing or
an imminent threat to public health or safety.
3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located«•ithina designated 100-}ear flood plain any ISTS which may
or may not meet all the location,design,or conswction standazds of the current Orono Municipal Code and which is failm�for any reason;and
any[STS with less than three feet of unsaturated soil or sand between the disuibution device and the limiting soil chazactc�ristics.
TANK CONDITION(5-7): s
Tank inspection indicates:
5� Pumpout not needed at this time.
6 Septic tanks must be pumped out this yeaz (city code requires tanl:s to be pumped out once every�3 years.
Tank was last pumped q-�-b —0'�. ).
Make sure seatic tanks are aumped throu�h manhole and not throuah white inspection pipes This allows for the
proper cleaninQ. Keep water softner and iron filter dischar�e out of septic s��stem.
7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia. pipe)must be installed in each tank. If
tanks have not been pumped out within the last three years,they should be pumped out now.
DRAINFIELD CONDITION(8-10): �
O8 Drainfield is dry,no surfacing evident.
9 Some evidence of surfacina, not critical yet.
10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the Cit}�Inspcctor
immediately.Repairs must be completed within 90 days.
COMMENTS: D«•;��--t\t} �c r�� 0� "��,�kS I oo(� v�
c�-�� —p� Gl�,� ��
Date of Inspection �iatt Bolterman - Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortga;e or other vansfer of propem•,be advised that this report does not guarantee
or certify that an existing system will continue[o function properly,but is merely an opinion ofthe adequacy of the system under current condmoas based on the available
information.
Telephone(952)249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
�o
„ � �
� O _ O i
� ���;�f,��_.� �, i CITY of ORONO
�;�, ��i,` �'� �`f;�� ,�ti Municipal OtTices
`�,� .r,,�,�,����� G
� "�',�"�_;�,, "�� Street Address: Maili�Address:
9$EggO�' 2150 Kelley Parlcway P.O. Bax 66
Orono, MN 55356 Crystal Bay, MN 55323-0066
Owner. � �o'� �e�� � Address: a I 3 S ���,� ; Gq � �
City Ordinance 199 requires that each e�sting on-site sewage treatment system in Orono be inspected even-mo years.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the cate�eries checked belo�v.
SYSTEM CONFORI�fITY (1-3): �
� ��C��E SZ'S�M�� An ISTS which meets all the location,design and construction standards of the current Orono l�funicipal C da.
2 ��COI�IPLIANT SYSTEM�� An ISTS which does not meet all the location,design and construction star:dards ofthe cuirr�Orono biunicipal
Code but does meet the threa foot sepazation requirzment,and which is not failing or an unminent threat to public health or safrr..
.i ��NON-COMPLIANT SYS1'EM° A prohibited ISTS;an ISTS located within a designated 100-yzar flood plain,any ISS which may
or may not meet all the location,design,or constru:tion standards of thz currznt Orono Municipal Code and�shich is failing fa.inv reason;and
any ISTS with less than thrze feet of unsaturated soil or sand between the distribution dzvice and the luniting soil characteristis
T?,ti�CONDITION(5-10): S
Tank inspection indicates:
OPumpout not needad at this time.
6 Tank must bt pumped out this year (city code requir�tanks to be pumped out every 3 yeats. Tartk was last pumped ),
� Solids accumulation in tarilcs is at a critical a critical lzvel. Tanks should be pumped out as soon as possiblz.
s S}stzm is discharging to the surface. Tanks must be pumpzd out within 48 hours to zliminatz surface discharge.
y Inspection risers missing-tanks could not be inspectzd Inspection risers(4"dia.pipe)must ba installzd in each tanlc at ne�ct pu��t If ra�t�c
have nut bezn pumped out within thz last three yea�,thzy should be pumped out now.
1� Inspection pipe is tocatad directly ovzr tank bafrle(dozs not give accurate measurement of solids accumulation). If tanlis havz nct',.�c�en pumped
out within the last threa years,they should be pumped out now.
DRANFIELD CONDITION(11-14): �
1 1 Draintield is dry,no surfacing evident
1? Soma avidznce of surfacing,not critical yet ,
13 Drainfield is saturatad and visibly dischazging untrzat:d e&luent to the surface. Contact thz City Inspector immediately.Repairs u�.L-a be
complztzd within 90 days.
1� Draintield e�tent and condition unknown.
co��NTs: SYS�� M 1bok5 0l(
�� -o� '�a,�,�
Date of Inspection Septic System Inspector �{
Note: In the e��ent that this inspzction repoR is used to satisfy the tequirements for a mortgage or othzr transfer of propeRy,be advised tha2 t�a report does not guazantee
or ceRity that an zxisting system will continue to function properl��,but is merely an opinion of the adequacy of the system undzr currerrt coa�:oos basrd on the available
informatioa
Minnesota Pollution Compliance Inspection Form
Control Agency
520 Lafayette Road North Existing Subsurface Sewage Treatment Systems (SSTS)
St.Paul,MN 55155-4194 Doc Type:Compliance and Enforcement
Inspection results based on Minnesota Pollution Control Agency(MPCA) For local tracking purposes:
requirements and attached forms—additional local requirements may also apply.
Submit completed form to Local Unit of Government(LUG)and system owner
within 15 days
System Status
System status on date(mm/dd/yyyy): 10/22/2019
® Compliant— Certificate of Compliance I Noncompliant— Notice of Noncompliance
(Valid for 3 years from report date, unless shorter time (See Upgrade Requirements on page 3.)
frame outlined in Local Ordinance.)
Reason(s) for noncompliance (check all applicable)
❑ Impact on Public Health (Compliance Component#1)—Imminent threat to public health and safety
❑ Other Compliance Conditions(Compliance Component#3)—Imminent threat to public health and safety
❑Tank Integrity(Compliance Component#2)—Failing to protect groundwater
❑ Other Compliance Conditions(Compliance Component#3)—Failing to protect groundwater
❑ Soil Separation (Compliance Component#4)—Failing to protect groundwater
❑ Operating permit/monitoring plan requirements(Compliance Component#5)—Noncompliant
Property Information Parcel p y ce D#or Sec/Twp/Range:
Property address: 2135 Carriage Lane, Orono Reason for inspection: Sale
Property owner: Scott Reid Owner's phone: 952-249-1946
or
Owner's representative: Representative phone:
Local regulatory authority: City Regulatory authority phone:
Brief system description: 2- 1300 gallon septic tanks with a gravity SB2 trench system
Comments or recommendations:
Certification
I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No
determination of future system performance has been nor can be made due to unknown conditions during system construction,
possible abuse of the system, inadequate maintenance, or future water usage.
Inspector name: Josh Swedlund _ Certification number: C1659
•
Business name: Sewer Services Inc. _/ - - License number: 2502
Inspector signature: _ _ Phone number: 952-873-3292
Necessary or Locally Required Attachments
® Soil boring logs ® System/As-built drawing ® Forms per local ordinance
❑ Other information (list):
www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 • Available in alternative formats
wq-wwists4-31 • 3/16/12 Page 1 of 3
Property address: 2135 Carriage Lane,Orono Inspector initials/Date: JS 110/22/2019
(mm/dd/yyyy)
1. Impact on Public Health —Compliance component#1 of 5
Compliance criteria: Verification method(s):
System discharges sewage to the ❑Yes ® No ® Searched for surface outlet
ground surface: ® Searched for seeping in yard/backup in home
System discharges sewage to drain ❑ Yes ® No ❑ Excessive ponding in soil system/D-boxes
tile or surface waters.
❑ Homeowner testimony(See Comments/Explanation)
System causes sewage backup into ❑ Yes ® No ❑ "Black soil"above soil dispersal system
dwelling or establishment.
❑ System requires"emergency"pumping
Any"yes"answer above indicates the ❑ Performed dye test
system is an imminent threat to public
❑ Unable to verify(See Comments/Explanation)
health and safety.
❑ Other methods not listed (See Comments/Explanation)
Comments/Explanation:
2. Tank Integrity—Compliance component#2 of 5
Compliance criteria: Verification method(s):
System consists of a seepage pit, ❑ Yes ® No ❑ Probed tank(s)bottom
cesspool,drywell, or leaching pit.
Z Examined construction records
Seepage pits meeting 7080.2550 may be
compliant if allowed in local ordinance. ❑ Examined Tank Integrity Form(Attach)
Sewage tank(s) leak below their ❑Yes ® No ❑ Observed liquid level below operating depth
designed operating depth. ® Examined empty(pumped)tanks(s)
If yes,which sewage tank(s)leaks: ❑ Probed outside tank(s)for"black soil"
Any "yes"answer above indicates the ❑ Unable to verify(See Comments/Explanation)
system is failing to protect groundwater. ❑ Other methods not listed (See Comments/Explanation)
Comments/Explanation:
3. Other Compliance Conditions—Compliance component#3 of 5
a. Maintenance hole covers are damaged,cracked, unsecured,or appear to be structurally unsound. ❑Yes' Z No ❑Unknown
b. Other issues(electrical hazards,etc.)to immediately and adversely impact public health or safety. ❑Yes* ®No ❑Unknown
*System is an imminent threat to public health and safety.
Explain:
c. System is non-protective of ground water for other conditions as determined by inspector. ❑ Yes' ®No
*System is failing to protect groundwater.
Explain:
www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800-657-3864 • Available in alternative formats
wq-wwists4-31 • 3/16/11 Page 1 of 3
Property address 2135 Carriage Lane, Orono Inspector initials/Date: JS 110/22/2019
(mm/dd/yyyy)
4. Soil Separation—Compliance component#4 of 5
Date of installation: 6/1/2000 ❑ Unknown Verification method(s):
(mm/dd/yyyy)
Shoreland/Wellhead protection/Food beverage Soil observation does not expire. Previous soil
lodging? ® Yes 1:1No observations by two independent parties are sufficient,
unless site conditions have been altered or local
Compliance criteria: requirements differ.
For systems built prior to April 1, 1996, and ❑ Yes ❑ No ® Conducted soil observation(s)(Attach boring logs)
not located in Shoreland or Wellhead
❑Two previous verifications(Attach boring logs)
Protection Area or not serving a food,
beverage or lodging establishment: ❑ Not applicable(Holding tank(s), no drainfield)
Drainfield has at least a two-foot vertical ❑ Unable to verify(See Comments/Explanation)
separation distance from periodically ❑ Other(See Comments/Explanation)
saturated soil or bedrock.
Non-performance systems built April 1, ®Yes ❑ No Comments/Explanation:
1996. or later or for non-performance
systems located in Shoreland or Wellhead Boring:
Protection Areas or serving a food, 1-8" 10yr 3/2 loam
beverage, or lodging establishment:
9-50" 10yr 4/4 sand/gravel
Drainfield has a three-foot vertical
separation distance from periodically No Redox
saturated soil or bedrock.*
•
"Experimental", "Other", or 'Performance" ❑ Yes ❑ No Indicate depths or elevations
systems built under pre-2008 Rules: Type IV
or V systems built under 2008 Rules(7080. A. Bottom of distribution media 12"from original
2350 or 7080.2400 (Advanced Inspector
License required) B. Periodically saturated soil/bedrock over 50"
Drainfield meets the designed vertical C. System separation 38"+
separation distance from periodically
saturated soil or bedrock.
D. Required compliance separation' 36"
Any "no"answer above indicates the system is 'May be reduced up to 15 percent if allowed by Local
failing to protect groundwater. Ordinance.
5. Operating Permit and Nitrogen BMP*—Compliance component#5 of 5 ® Not applicable
Is the system operated under an Operating Permit? ❑ Yes ❑ No If"yes",A below is required
Is the system required to employ a Nitrogen BMP? ❑Yes ❑ No If"yes", B below is required
BMP=Best Management Practice(s)specified in the system design
If the answer to both questions is "no", this section does not need to be completed.
Compliance criteria
a. Operating Permit number:
❑ Yes ❑ No
Have the Operating Permit requirements been met?
b. Is the required nitrogen BMP in place and properly functioning? ❑ Yes E No
Any "no"answer indicates Noncompliance.
Upgrade Requirements(Minn. Stat. §115.55)An imminent threat to public health and safety(ITPHS)must be upgraded,replaced.or its use
discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance. If the system is failing to protect
ground water, the system must be upgraded,replaced, or its use discontinued within the time required by local ordinance. If an existing system
is not failing as defined in law, and has at least two feet of design soil separation, then the system need not be upgraded, repaired.replaced,or
its use discontinued,notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas,
Wellhead Protection Areas.or those used in connection with food,beverage,and lodging establishments as defined in law.
www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • TTY 651-282-5332 or 800.657.3864 • Available in alternative formats
wq-wwists4-31 • 3/16/12 Page 3 of 3
4(33 L ARllirtbc 1
)_L
75
riAlLIRE
(5 8A)
2e1L
C7. nth
y• -J1M If 5'61.5 Gl-
D6 r 76'6 fc'Y
1 ei'
31e5/ 6)'6
'1 c 'b ,L
b a,, M11-
7 ®® n
W it
1111 IVY 38`c