HomeMy WebLinkAbout08-17-2011 - Water intrusion repair � � . r r: I nte rit g Y Home Pro�ects, Inc. 7524 Fairfield Road Brooklyn Park, MN 55444 Phone: 763-286-7429 Water Intrusion Repair Project and Upper Level Flashing and Trim Project PROJECT 29-11-003 Jobsite Address Peggy Kadlec 2726 Caroline Avenue Wayzata, MN 55391 August 17, 2011 � Integrity Home I'ro�ects, Inc. Project#29-11-003, Permit Scope of Work Peggy Kadlec 2726 Caroline Avenue Wayzata, MN 55391 August 17, 2011 Water Intrusion Repair Project Sco�e: DEMOLIT[ON AND S[TE PREPARATION • Work is planned to be done with deck ledger remaining in-place o No deck framing or ceiling joist framing is planned to be removed and replaced. If rotted ceiling joists are discovered, additional costs will be incurred. • Install temporary structural support walls approximately 3 feet inside and outside of header repair wall. 0 2x 12 load spreading plate to be set on screen porch tile to minimize stress on floor • Install dust protection barrier poly on temp walls to isolate work area • Apply RamBoard floor protection on screen porch tile floor in work area • Apply Carpet Shield floor protection on interior basement floor in work area • Remove casing and trim moulding from interior of lower level patio door and side-lites—set aside for re-use • Remove drywall from interior wall above lower patio door and side-lites • Remove drywall from interior ceiling approximately 3 feet in from wall above lower level patio door and side-lites. • Remove bilt-rite sheathing from exterior wall above and beside lower level patio door and side-lites. � Remove any fiberglass batt insulation that has been compromised by water intrusion • Remove lower level patio door and side-lites, set aside for re-install. o Note: patio door frames may be rotted from water exposure. If new doors or door repairs are required, additional costs will be incurred. • Remove header, rotted cripple studs and rotted section of plates above and below header for lower level patio door. • Remove rotted section of 2x12 rim joist. Anticipate 32" section to be removed and replaced (2 joist spaces) • Remove and dispose of demolition materials EXCAVATION, FOOTINGS, BLOCK, STONE, MASONRY • None planned FRAMING/CARPENTRY/INSULATION • Install replacement section of 2x12 rim joist,#2 or better grade SPF • Install replacement section of double top plate, cripple studs and upper header plate • [nstall new header, 2-ply 9 '/4' x 1.75" LVL(microlam) • Install new mid-span bearing support trimmer studs, one pair is known to be rotten, but plan to replace both pairs • Spray all internal wall surfaces exhibiting mold with PCG Pro-cleanT"' and spray all surfaces exposed to moisture intrusion with MycoDyneT"' mold preventative • [nstall new bilt-rite sheathing � Re-install patio doors and side-lites. Butyl seal wrap included Page 2 of 4 . � � � Integrity Hoine I'ro�ects, [nc. Project#29-11-003, Permit Scope of Work Peggy Kadlec 2726 Caroline Avenue Wayzata, MN 55391 August 17, 2011 • Install new R19 wall insulation where compromised insulation was removed. [nstall insulation around perimeter of patio door RO. • Install new 4 mil poly vapor barrier where drywall was removed HVAC • None planned PLUMBING • None planned ELECTRICAL • None planned WALLS& CEILINGS � Install new ceiling and wall gypsum wallboard where removed for interior access • Taped and sanded, ready for priming and painting by others CABINETS AND COUNTERTOPS • None planned TRIM-OUT AND FINISHING • Re-install interior oak trim on patio door and side-lites • Re-install siding on wall inside of screen porch around patio doors and side-lites • Caulk siding at door and screen porch trim o No new siding planned. Assumes existing siding will be re-usable • Install new flashing and wrap on windows and door to deck above screen porch o Install new clipped aluminum drip cap flashing on the round-top window and two quarter-round windows. White drip cap to be installed, painting by OTHERS. o Install exterior moisture barrier(Tyvek�or equivalent) o Install butyl window perimeter seal wrap o Install new 5/4"x 8" Knotty Red Cedar Rabbeted Siding o Install replacement horizontal and vertical door#2 rough cedar trim with Z-flashing FLOORING AND T[LE • None planned Page 3 of 4 ---�.�.�„, __.__, . ���� ��`` . � �: ��, , ,. � _ � � ,.- � �� � , a �____ . _<,. ., s _ ��;� /� ' __ - • . � � ' ,��� s�e�^;1�• ' �� �';,�z �.` , .. , —�,�' � ' �` - -- -- � ' b.��i, � � . . a,� ��,., • �� - �. . �.�P. . ..�, _ ���--r � � � - _ - r � �-�, ' y .. � ,;�-'_a, � �,,,:�, r � �, �. M_,� �: ' � �` ... � � ,y, ... _ _ �r � . ` �a � . „ �� O ,__ . �-�� � s r � -� ��s '�c�;�: � �` ��s � ♦ , ',��. •�"�� r` �� w* y,.. � � � ( , . ... �. .K, . . .,�"� ..:..... 'Tm sA+�1r � ... � .>. . . "+~�... ..��� .Y�' � ... �,» .. � LA 1� E � . �,�: � �fe,�[`�Mti7�.A.�, ,. .. .� � :� �� x�,� � �;�+ � �� �'�' R � � , . „ � , y,,��,� . , ��` �',�� �,�z"� , .; , . , + _:" .. ..,• .._ __._ ,��. , .�.�� b,..�.._..�.,....�., , � ,� ` . ,, �>.: �: . _ �{ � f . . � ti �, � , . � , " .�" _,�, � �, �\ � � •{:: F ..� �� � ��' '�; ,�� . " ✓ ....�• a�„� M r ' . '� ,� t _ �,� � �°�u & � � r7�'� '�.�^.' ± a+�� "`` i.. ; � ��� , E 4� 4' �'+ "�I ' f "�'. e e� � � �1�, �+�`e ' j� � "# � n ,�c " t �a �� �. ' - � ;' , �_ , r • � ,, *���,� .��� i�. ; � � � -- -.— ,/�-` �'�, n.�2;�t E'°� µ � ... 1• , � _ }�� �"�` �'fi�. ,'s. , �4 � :.re. 'yl� ._.�" �..;.._ '�,.. �i'� ,�� ' �,.{�,!'� E � +� . . .. . , . n� o � . . �...-.... a� .. � � �� k � �� '� � � # { t �N�� .. � '�� ' S• � . �. �� � ' . � � > ��� `. � ...:5 _.: ' �� ` . M . >. ��.. " .: ' JI�'�" , ���: > ,. . "� � � : � a r i� �.... f_. r .1 '� ��`� � � '1► � o�-�w a� � ,�. ,: .._.w- u � ,_,..'I .._ .,. 3;"'"'... �..... , . . . .�._�. .._ ..:_. J �' ,�� P y s..F � :;.J• 'w �' . . .. . . d;� ., � � ���� . . _ _.—� r�„ . . � ... . . - � � - — ..,, , .�, . _ �•`��".,�,,� �.-- -- — , � ��� � ���� I � � * ��µ�� c"'�. T- � ___ _ .. .. .� - r _ .. . --• � �: I 4 ; F � i& :_.�. , ._. ..,_ f