September 25, 2000
Adrian& Pamela Kearney
26� Brown Road South
Long Lake, Mn 55356
Dear Mr. & Mrs. Kearney:
An inspection of your septic system was conducted on September 18, 2000. A summary of the
inspection is belo�v.
Septic Tank Condition
1. Pumpout needed within one year (last pumpout date 6/S/87).
The septic system is non-compliant due to a lack of a three foot separation distance between the bottom
of the drainfield to the seasonally high watertable. The three foot requirement is a State Code, not a City
Code. A soil borinb was conducted to determine the depth of the seasonally watertable. The residence
must be connected to municipal se�ver by Decembe►•31, 2010.
Enclosed is a list of state licensed septic contractors �vho �vork in Orono on a regular basis. Also
enclosed is a fact sheet eyplaining how a septic system functions properly. Finally, an as-built drawing
is enclosed that shows the approximate location of the septic system.
If vou have any questions regarding this report, please contact me at the City Offices at 249-4600.
R 'pectf ,
��^� �c'+�it/
hris Pence
On-Site Systems Manager
Enclosures
In the e��ent this inspection report is used to satisft'the requirements for a mortgage or other transfer of property,be
ad�•ised that this report does no guarantee or certify the esisting s}'stem will continue to function properly,but is
merely�an opinion of the adequacy of the system under current conditions based on the available information.
This report must be kept on the premises with the system location and pumping records.
Telephone(952)249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
— -- --- -_
,��/� O�\
��� �
,�
' � CITY of ORONO
'�, ,
; ,,a � '.'��,� _ �►
� i y: ti MunicipalOffices
'��;
� � ��� �%� Street Address: Mailing Address:
�. '� � ` � � '�i; �
� V`9kE8Kpg'� 2750 Kelley Parkway P.O. Box 66 �
_
On the North Shore of
Lake Minnetonka
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT � POST OFFICE BOX 66
1335 S. Brown Rd.
� � � Crystal Bay, MN 55323
473-7357
OWNER ��.�C/1`-� �'f�� `� ��'. ADDRESS �CS� ,�✓�l�'1 /�XI -��
PERMIT NO.'S. � �-��'�DATES �I��L�l C��I� CONTRACTORS �I��r�r{�-��nr,�H�/S�
City Ordinance No. 210 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.The onsite sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is �I an existing system ❑ new construction)
R'�f � Meets or exceeds current City standards in all respects relating to design,construction,and location.Appears to be operating
�« properly.
� 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major
upgrading of the system is required at this time.
� 3 Does not meet current City standards in many respects relating to design,construction,or location.Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
� 4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and
dispose of the current input,and is endangering a water supply, or is a source of pollution to surface or groundwaters,or is
creating a safety hazard, or is oiherwise creating a public�uisance.Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary, soil testing will usually be required,and a design and site plan
must be submitted for review.Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( � Checked items may require your action)
Tank i�spection indicates: ��� Inspection pipe is located directly over tank baffle.(Does not
❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.l If tanks
❑ Solids accumulation in tanks indicates they should be pump- have not been pumped out within the last three years, they
ed out this year to help prevent future problems. should be pumped out now.
❑ Solids accumulation in tanks is at a critical level, Tanks Drainfield inspection indicates:
should be pumped out as soon as possible. � Drainfield is dry,no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped ❑ Some evidence of surfacing,not critical yet.
within 48 hours to eliminate surface discharge. ❑ Drainfield is saturated and visibly discharging untreated
❑ Inspection risers missing—tanks could not be inspected, effluent to the surface. This condition may require replace-
Inspection risers (4" dia. pipe)must be installed in each tank ment or additions to drainfield. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately.Repairs must be completed within 90 days.
the last three years,they should be pumped out now. ❑ Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure Site Capabilities for
❑ Slope (depends on soil types,water Futu e Expansion
❑ Soil table,and system condition) �Adequate
❑ High water table � Low ❑ Fair
❑ Lot size ❑ Medium ❑ Poor
❑ Lake,wetland,or stream ❑ High ❑ Inadequate
❑ Drainage ❑System is ca�sing visible
surface discharge.
COMMENTS:� QL/1� �f�'CiY(.t � �i►'-nlr'�/�"_f_�l��([�I�LS ,�/�Y_1°_ 1�������%
�/Y� ,S�Ji/��l.%� ,�//�Q�����
�D/l�r�C>> �'
Date of I�spection Septic System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that
this report does not guarantee or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY/ Inspector's File GOLD COPY/Homeowner
� �+ SEPTIC SYSTEM INVENTOR Y
_ _ _ _ _ _ __ _
Address: 265 Brown Rd. S. PID: 03-1 17-23 24 0001 �
Building Typ residence #BRs/GPD: 4 #Systems 1 Units Billed 1
Permit#: 206, 514 Date of Permit: 9/21/87, 5/19/ Installer: Halstad Contr., Coolbrot
System Type standard trench Experimental: no Appliances lndry
SYSTEM CONDITION
Conformity: 3 Tank Condition: 5 DF condition: 11 Failure Pot: med
�
SEPTIC TANKS
Material: precast concrete Capacity: 1000, 1000
Setback to Bldg: 14 Cesspool: no
DRAINFIELD
�
Length of Lines 225 # Lines: 3 Trench Width: 3 e
Treatment Area: 675 Type of Filter rock Soil Boring: yes
Tile Size: 4 Under Tile 12 Perc Rate: 15
Setback DF-Bldg: 40 DF Ht above Wt: 1.4
Soil Type: loam, clay loam Limitations: water table
WELL DATA
Setbacks - Well-Tanks: 50 Well-DF: 75 Report in File no
Pump Type: Depth: Diameter: Method:
INSPECTION RECORD PUMPOUT RECORD
DATE DESCRIPTION COMPLIANCE DATE GALLONS
5/1/82 me w/Ed Sullivan on site RE: repairs 6/4/84 1000
8/12/82 system is dry for now 3 6/8/87 500
6/19/86 slight seepage, not critical yet 3
7/29/86 still seeping 3
9/23/87 new system installed 1
10/10/90 no surfacing-pump tanks 1
5/26/92 no surfacing-pump tanks 1
9/28/95 no surfacing 1
10/12/98 non-compliant-slight surfacing,repair 200 3
9/18/00 non-compliant, connect to sewer 2010 3
� , �-� �Q.�,,��2 �n c 1 � o 0
C� c�v1 PCi�
._ .�� ��wc:� ��► S�c�� f;le .
/
. ��
.. �, .
. . ,
��� ��"O t�/ h �� J
�� , ,
I � ;�' , Ne' �f c��Dr
� g ��L �� �
T; rN I`lS 2�'S / / �o� .�
� �
M�l I��S 30� , � /�
-f'Z�,� 23� 3(0� �0 � � �
�N z�' y� `�/ �� /
pB � S3� �S�s / '� , i � \ `
z. �3` 7 y'� � / �o/ yN
� �
3 �73' �`��
� / � g
/ /
/ �
/
� /
� .
I � / �
I �
� � I` .�- — , / ��
'e°�,.0 � r `- -- _ -- _ � 1_ _ _ -
� S ��,
CITY OF ORONO � O�
Municipal Offices O � O
Post Office Box 66
Crystal Bay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT
r�, �C�, INSPECTION REPORT
'��, G~
9kESHa4'�
Owner: � Address: �� L��6.�I'"\ 1`.;..{� �•
Permit #'s: V Dates: �.1)�� Contractors: ��/��i'a' ( �}�l Y',
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site seuage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is � an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3):
1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the
current City Codes, but Was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic � has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identi ied, this classification may be subject to revision.>
TANK CONDITION (5-10): �
�inspection indicates:
5 Pumpout not needed at this time.
Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be p�xnped out within 48 hours to eliminate surface dischar�e.
9 lnspection risers missing-tanks could not be inspected. lnspection risers (4" dia. pipe) must be installed tn each
tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
lf tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14):
Dr�field inspection indicates:
11 Drainfield is dry, no surfacing evident.
Sane evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
irtmediately. Repairs must be completed uithin 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): ��
COMMENTS:
� ' -.
Date of inspection epti ystem Inspector
Note: ]n the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
tnformation.
This report must be kept on the pre�nises with the system loc=tion and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner
CITY OF ORONO � O�
Municipal Offices O � O
Post Office Box 66
Crystal eay, MN 55323-0066 � � ON—SITE SEWAGE TREATMENT
„� � INSPECTION REPORT
ti
��9kESH��'�G
Owner: /�/,('ilvr�Pn �/��ih�,s Address: v�� �✓�l'� /4'�� S
Permit #'s:���Dates:��73�7/ /��'�✓ Contractors:�C-ri�Dl'p�'h-5��� .,��
City ordi.nance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(7his is p� an existing system [ ] new construction)
SYSTEM CONFORMITY (1-3):
"CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
2 "CONFORMING SYSTEM'�-A system which does not meet all the location, design, and construction standards of the
current City Codes, but uas installed according to the code in effect at the time of installation, and uhich
is operating satisfactorily by treating and disposing of the entire current seuage input without discharging
any pollutants into ground or surface waters.
3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limiting soil characteristic �has or [ ] has not been identified at this time. If the limiting soil
characteristic has not been identi ied, this classification may be subject to revision.)
TANK CONDITION (5-10):
Tank inspection indicates:
5 Purtipout not needed at this time.
6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems.
7 Solids accunulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out uithin 48 hours to eliminate surface dischar�e.
9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each
tank at next pumpout. If tanks have not been punped out within the last three years, they should be pumped
out now.
� Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation).
If tanks have not been pumped out within the last three years, they should be pumped out now.
DRAINFIELD CONDITION (11-14): jJ
�F{
Dr field inspection indicates:
�] Drainfie[d is dry, no surfacing evident.
'f2 Some evidence of surfacing, not critical yet.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
irtmediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope,setbacks,etc.):
POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): /�/
G
cor�E Ts: - v rPcc�.j � - " ►�C G�.S � � �iiY�'
� — D t� r
�'��'' � P
Date of Inspection eptic System Inspector
Note: 1n the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly� but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the prF�nises with the system loc�tion and pumping records.
WHITE COPY/Inspectors File YELLOW COPY/Homeowner