HomeMy WebLinkAboutPermit and zoning issues %�o
� �
%�0 O
,�
r,�,,, � CITY of URONO
� x � '�(' -��- ti ' Municipal Offices
, �,� , �� ,
� Street Address: Mailing Address:
�� ��,;;
�� ���E$H�- %�"� 2750 Kelley Parkway P.O. Box 66
- - Orono, MN 55356 Crystal Bay, MN 55323-0066
August 10, 2005
Roberta Roth & Thomas Quast
1251 Briar Street
P.O. Box 159
Crystal Bay, MN 55323
RE: BUILDING & ZONING CODE ISSUES AT 1251 BRIAR STREET
Dear Ms. Roth &Mr. Quast:
On 09-24-99 the City of Orono issued permit#11916 to you to construct a new home on
the existing foundation at 1251 Briar Street in Orono. As of this date the project has not
had final inspections and an occupancy permit has not been issued. It has also come to
the City's attention that you have erected a fabric covered boat shelter on the property.
Therefore the City must require you to arrange an inspection to see if there are any code
issues to resolve on the house so that a certificate of occupancy can be granted. The City
requires building permits for structures built on property, however a fabric covered boat
shelter does not meet any building code requirements. Therefore, the boat shelter must
be removed from the property.
A deadline of August 29, 2005 has been established for removal of the boat shelter and
for arranging a final inspection on your house. If this deadline is not met, the City may
initiate legal action. If you have any questions, feel free to contact me at my office.
Sincerely,
�
Lyle Oman
Building Official
rd
Telephone(952)249-4600 • Fax(952)249-4616
www.ci.orono.mn.us
_
���/��G�G`''�! �'Z''���.��C;.%� �
�"'� ``-'C
�� s
� �!� �-
, �
�%'����- �'�u�( ,��� a-
/
_ ��r�-��� ����
L�`� C�--����
-_____ .__ __
--__ _ ����� �Lz� / ��
;��i� ��
. ���l U��-.�'��
�� -�
. ��
_ . ;; i��
��3� � �
f�,��-�� ,� '�P��� �-z� �s
ii
� �
� � .
(�ITY of �Rt�NO
a �
�, Municipal Offices
��� G~ Street Address: Mailing Address:
`!$E$gp�'� 2150 Kelley Parkway P.O. Box 66
Orono, MN 55356 Crystal Bay, MN 55323�0066
August 30, 2005
Tom Quast
1251 Briar St.
P.O. Box 159
Crystal Bay, MN 55323
RE: Final inspection and boat issue
Dear Mr. Quast,
This letter is to confinn issues discussed at our meeting on August 29, 2005. Due to a change in
building inspection staff your project was overlooked for a period of time. The building pei-mit
was issued on September 24, 1999. The last inspection was on May 2, 2000. I don't know what
your conversation was with the previous inspectar, but The City has always followed the
requirements of the Building Code with respect to occupancy. A temporary certificate of
occupancy can be issued if all the life safety items are completed. The following list of
requirements are always required before anyone is allowed to occupy a residence.
1. Handrails are required on any stairs with 4 or more risers. The handrail must be between
34" to 38" off the nosing of the treads and provide an approved gripping surface. The rail
must be continuous, the full length of the stairs, and shall terminate in a newel post or
safety terminals (see attached handout).
2. Open sides of stairs over 30" offthe floor must be provided with a railing 34" to 38" high
with 4" maximum spacing.
3. Smoke detectors are required in bedrooms, the hallway leading to bedroorns, and in the
basement. The smolce detectors must be wired into the electrical system, have a battery
back up, and must be tied together so that if one sounds they all sound.
4. An overflow tube must be provided at the water heater to within 18" of the floor.
5. A landing and stairs must be provided at the front door. The miniinum size is 3' x 3'.
Due to the substandard setbacic to the street the maximum size is 4' x 4'. The stairs shall
be minimum 8" maximum rise and 9"nlinimum run. Guard rails and handrails shall be
as discussed earlier in tl�is letter. �
6. Provide gas valve in a readily accessible location at the cook top.
7. A final electrical inspection shall be provided by the state electrical inspector.
8. In revie��ing the file, I found that the plumbin� was never inspected. Therefore, you
must provide a manometer test on the plumbing system which must be witnessed by a
building inspection staff inember.
'�'e�ep���e(�52)2�9-4600 � Fax(95%)�49-461�
�vvvvweefl.�a�ono.�naa�.aas
2
On August 2, 2001 the inspector that inspected your home left an inspection slip (copy enclosed)
that noted you had occupied the home without approval. As I previously stated these are all life
safety items and must be completed as soon as possible, but no later that September 30, 2005. In
regards to the boat shelter, an extension has been granted per your request until October l, 2005.
If you have any questions please feel free to call me at my office.
Sincerely,
.%�
�..
�
Lyle Oman
Building Official
LO/dml
Enclosures
�
� Acceptable Handrails - all others must, be approve3 by he
i.nspector.
li/,° to 2" 1�/z" 11�" ' 1�/2"
M(N. to 2" MIN
� . - -
� �
1'!2' 11/" to 2 " �
MIN.
� � 3'/z"MAX.
,,���
1��
�
c N
�
T 'OO . .
.`�Z
r-� ,,,
NOTE:
OTHEFt SHAPES MAY BE ACCEPTABLE
IF THEY PROVIDE AN
EQUIVALENT GRIPPING SERVICE.
SEETHIRD PARAGRAPH OF � �
SECTIOy 3306 (j).
�O� ������'���.�
Handrails are required on int,erior �and exterior stairs with �
or rnore r�.sers o
�Iand.rails sl_-iall be placed not less chan 3d inch�s o�� rr�ore than
3� �nches above t�e nosing of treacls < 'I'h.ey snall be continuous the
full length of the stairsa Er.ds shall be returned or shall
terminate in newel ,posts or safety �erminals .
The handgrip portion of har.drails slza�.l be not less �°r!G..:� 1 �./�
inches or more �han 2 inches ir, cross-seccional diriension or �h�
shape sha11 provide an equivalent gripp�ng surracee The handg�`i�
portion or handrails shall have a smooth surface with no sharp
corr.ers .
handrails projecting from a �,-all sh�l1 have a space of not
:�ess tnan i 1/2 inches be�.ween the ��all and the handrail o
�
. � . �
DATE TIME
CITV OF OROPIO CALLED IN ;
iNSPECTlON NOTICE SCHEDULED �
PERMIT NO. /� COMPLEiED � ��=�� ;
ADDRESS �2�� ��ia-� .S �• I
01NNER C0�lTi�. �
TELEPHONE,N0. �
� DESCR4PT90N �Gr.t..�Q��,� GI D�t s-2 �/�il��c��.c-r� �� ,
� 01 FOOTING 11 MEC ANICAL RI 18 EXCAV/GRADING/FILLING
.Q 02 FRAMING 13 MECHANICAL FINAL 19 LAKESHORE/WETLANDS
y 03 INSULATION 24/25 WOOD BURNER/FIREPLACE 34 TREE REMOVAL
� 04 WALL BD. 12 WATER HOOK-UP 17 SITE INSPECTION
Q OS FINAL 14 SEWER HOOK-UP 06 PROGRESS
� 07 DEMO-SITE 27 SEPTIC MAINT. 21 COMPIAINT
v 07 DEMO-FINAL 15 SEPTIC ItdSTALL. 22 FOLLOW-UP
? 09 PLUMBING RI 23 SEPTIC FINAL 35 HARD COVER REivIOVAL
J 10 PLUMBING FINAL 36 FOUNDATION/REMOVAL
� OWtdERlCONTAACTOR TO N9EET YOU:_YES_Pd0
� C I�M E T'S: � ^
a �-� �e� >v ,-� �!�(-S/.�
o � YlD cc J�a
� O�-C,�. C ` d� ��ir� � %� ec �
o �i S� .
�
Q � ��J�1-- �`�i� ��c.c.. 6 -e
� !1 .�/r Q4.�
� �°'O/� LJ l�J�I� ��h'yI i� f�� � �v'�
�
�
a
W� ❑WORKSATISFACTORY:PROCEED ❑ PAOJECTCOMPLETE
� O CORRECT WORK&PROCEED ❑ ISSUE CERTiFICA7E OF OCCUPANCY
� �CORRECT WORK,CALL FOR REINSFECTfON TEMPORARY
V BEFOFiECOVERiNG PERNOANEPIT
O CORRECT UNSAFE CONDITIOid WITHIN HOURS. p pHOTO TA4CEN
IIUSPECTOR W{LL RETUR�
❑STOP ORDER POSTED.CALI INSPECTOR
❑ CITATION ISSUED
❑ I�dSPECTIOPdREQUIRED.CALLTOARRdFlGEACCESS.
��66�s�r�����:c�6aa����?���a�4�a�����r����a���. (����� ���������
�4i�v�es��Ca��s�,^3a �ss7�:
�6]s�G�CtS2Y: �'�'��z,� �C/�%�U'l�
�11h�te CopyAnsp�c8or's�i3a :;anan/Co�ylSf9e Mo�ica