HomeMy WebLinkAbout1987-08-04 On Site Sewage Treatment Inspection Report)
1
ON SITE SEWAGE TREATMENT
INSPECTION REPORT
On the Sortb Shore of
Lake Minnetonka
T V
ORON(^POST OFFICE BOX 66
1335 S. Brown Rd.
Crystal Bay, MN 55323
4737357
OWNER V_____________________address
PERMIT NO.'S. "7 3 ----- DATES —^ ^ -------------- CONTRACTORS
J'rnn^is f 1^^ ^orxcjf
City Ordinanca No. 210 require* that each on-«ite sewage treatment system in Orono be inspected on a regular basis. The on-site sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is ^^Can existing system □ new construction)
<1 Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating
properly.
n~t 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, artd constructed generally in accordance with previous codes. System appears to be functioning properly; no major
upgrading of the system it required at this time.
pn 2 Does not meet current City standards in many respects relating to design, construction, or location. Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
r~] 4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat ant,'
dispose of the current input, and is endarsgerirrg a water supply, or is a source of pollution to surface or groundwaters, or is
creating a safety ha7ard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/
replacennent procedures. If drainfield replacement is necessary, soil testing will usually be required, and a design and site plan
must be submitted for review. Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( Q| Checked item* may require your action)
Tank inspection indicates:
, Pumpout r>ot rteeded at this time.
Solids accumulation in tanks indicates they should be pump
ed out this year to help prevent future problems.
□ Solids accumulation in tanks is at a critical level. Tanks
should be pumped out as soon as possible.
D System it discharging to surface. Tanks mutt be pumped
within 48 hours to eliminate surface discharge.
□ Inspection risers missing-tanks could not be inspected.
Inspection risers (4‘* dia. pipe) mutt be installed in each tank
at next pumpout. If tanks have not been pumped out within
the last three years, they should be pumped out now.
□ InuMction pipe it located directly over tank baffle. (Does not
give accurate measurement of solids accumulation.) If tanks
have not been pumped out within the last three years, they
should be pumped out now.
Drainfield inspection indicates:
13! Drainfield it dry. no surfacing evident.
□ Some evidence of surfacing, not critical yet.
C Drainfield it saturated and visibly discharging untreated
effluent to the surface. This condition may require replace
ment or additions to drainfield. Contact the City Inspector
immediately. Repairs mutt be completed within 90 days.
□ Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors
□ Slope
□ Soil
□ High water table
□ Lot size
D Lake, wetland, or stream
□ Drainage
COMMENTS:rate's
Potential for System Failure
(depench on toil types, water
i(e^and system condition)
Low
Medium
□ High
□ System it causing visible
surface discharge.
table,
§
Site Capabilities for
Future Expansion
^Adequate
□ Fair
□ Poor
□ Inadequate
rs i 74?
Date of Inspection Septic pfixmm Inspector
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that
this report does not guarantee or certify that an existir>g system will continue to function properly, but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY / Inspector s File GOLD COPY / Homeowner
7