Loading...
HomeMy WebLinkAbout1999-11-08 On Site Sewage Treatment Inspection Reportk l: 1 CITY OF ORONO Municipal Offices Post Office Box 66 Crystal Bay, MN 55323-0066 Owner:5-4nt->kA o ON-SITE SEWAGE TREATHENT INSPECTION REPORT Permit #*b: Address: "^^*30 LU >P</ /5j5>y*j^/j) Dates: ji/6J Contractors: (S^UtCkuJA'^ City ordinance nurber 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis checked*l:)elow**”"®* treatment system at the above address has been inspected and appears to fall into the category (This is ^ an existing system [ ] new construction) SYSTEM CONFORMITY (1-3): /£> 2 “CXE SYSTEM''-A system which meets all the location, design, and construction standards of the current City Cqdes, a^ which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. "CONFORMING SYSTEM"-* system which does not meet all the location, design, and construction standards of th* current City Codes, but was installed according to the code in effect at the time of installation, and which IS operating sansfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. 3 "NON-CONFORMING SYSTEM"-* prohibit^ system; a system located within a desig-iated 100-year floodplain* an' system which may or nwy not meet all the location, design, and construction standards of the current* City Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sarj between the distribution device and the limiting soil characteristics. (The limiting soil characteristic has or [ ] has not been identified at this time, characteristic has not been identified, this classification may be subject to revision.)‘ the limiting soil TANK CONDITION (5-10) LanKinspection indicates: Pumpout not needed at this time 6 Solids accunulation 7 Solids accunulation future problems, as possible. in tanks indicates they should be punped out this year to help prevent in tanks is at a critical level. Tanks should be pumped out as soon as 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be puiped out now. 10 Inspection pipe is located directly over tank baffle (does not If tanks have not been pumped out within the last three y(give accurate measurement of solids accunulation). years, they should be pumped out now. DRAINFIELD CONDITION (11-14): fj OHITinfield inspection indicates: C_1V Orainfieid is dry, no surfacing evident. Some evidence of surfacing, not critical yet. 13 Orainfieid is saturated and visibly discharging untreated effluent immediately. Repairs must be completed within 90 days.14 Orainfieid extent and condition unknown. to the surface. Contact the City Inspector LIMITING SITE FACTORS (slope.setbacks.etc.); POTENTIAL FOR SYSTEM FAILURE tdeoends on soils.water table.etc.i; /Q COMMENTS: iN9 9^a Date of Inspection Septic System Inspector Note; In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current conditions based on the availableinformation. This report must be kept on the premises with the system location and pumping records. WHITE COPY Inspectors File YELLOW COPY/Homeowner