Loading...
HomeMy WebLinkAbout1997-04-24 On Site Sewage Treatment Inspection Reportoo j-* . h. L ! c GITYof OR0NO MuniciiMl Offices Street Address: 2750 Kelley Parkway Orono, MN 55356 MaWng Address: P.O. Box 66 Crystal Bay, MN 55323-0066 Owner:H'iC ^qgL^Q>*fih rhc n Address: 1205 French Creek Dr. Permit «'s: 2383 Dates: 10/9/S9 Contractors: Clover Bill Co. (This is l'^] an existing system [ ] new construction) 2 SYSTEM COMPLIANCE (1-3): 1 Code System: Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. Compliant System: Does not meet all current City standards for new onstruction, but in most respects appears to be designed, located, and constructed in accoi. *ance with previous codes and is functioning properly. Non-Compliant System: System may or may not meet current City standards for design, construction, or location, but is failing to properly treat amd dispose of the current input; and any system with less them three feet of vertical separation between the bottom of the dralnfield and the saturated soil level. J 3 (The eaturated eell level [ N^] haa or ( ] has not been identified at this time. If the saturated soil level has not been identified, this olasslfication is subject to revision.) 6 7 TANK CONDITION (5-9): 8 5 Pumpout not needed at this time. Solids accumulation in tanks indicates they should be pumped ou this year. System is discharging to the surface. Tanks must be pumped out within 48 hours. Inspection risers missing-tanks could not be Inspected. If temks have not been pumped out within three years, they should be pumped out and risers Installed now. Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks have not been pumped out within three years, they should be pumped out now i iI 9 (Durlna the last septic tank Maintenaace Pumpout the tanks ( ] were or ( ] were not conflrsMd to be watertight by the licensed pumping contractor. If the tanks were not confined to be watertight, this classification is subject to revision.) DBAINFIELD CONDITION (11-14): 11 ^11^ Dralnfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Dralnfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Dralnfield extent and condition unlcnown. POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.); low COMMENTS: </Av/97 Date of Inspection ^Septic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an exl<tlng system will continue to function properly, but indicates the operation of the system under currant conditions. Tdephone «12)473-7357 • FAX4734I510 4