Loading...
HomeMy WebLinkAbout2000-03-17 Septic System Inspection ReportI Swedlund Septic — Service March 17,2000 Re: Septic System at Cashman’s, 1205 French Creek Dr. Jerry, During the septic inspection, it was discovered that all 3 septic tanks were foil into the risers indicating the effluent wasn’t getting out of tanks. First & secondtonks require manhole risers by code & weren’t installed when septic was buih. These two tanks haven’t been cleaned properly & had abundance of sludge & scum. Third tank (pump chamber) had never been cleaned & both pumps were completely covered in sludge. Appears neither pump is working & al^ m house must not be working. Wiring in electrical panel is hard wired (not code) and n^ to be updated. To determine all work needed, pump chamber has to be wasM & pumped, piping & pumps & floats have to be removed & repaired or replaced. First and second tanks have to be washed & pumped & 24” rnanhole risers installed to surfoce and it needs to be determined why alarm in house isn’t working. Price to correct above would be time & material. Range should be between S2000 &$5000. Jeff Swedlund LA --- Swedlund Septic Service • 9520 Laketown Road • Chaska. MN 55318 • 442*5855 STATE CERTIFIED =-.r 1 ■ 1 #' ■■'pf a. t: V li, I V i.;.- fr\ ::£M. W-My ■v#*V.-6. V ;*-<< t.: lukRi^ OtU*— .*prM. <5, 2000 llMfJ.PltMtM C*. $92t OifM Aw. »iUm. mn $$m 97M420 / 47t*At51 Jerry Boldenou (Builer) 1205 French Creek Drive Orono, *« * 0 ^C/Ty % Ti>k Ct^itt^r — i if Taiki 3-1500 gallon tanka typ tf Twill OilliM — precast concrete , I------------—* pumped 6500 gallons MialiiUt to §ri4i YE^O Replaced 2 pumps, electrical, all switches in tank. UCMN #219 mj' ,, i' a -I . ■■ '■