HomeMy WebLinkAbout700 North Arm Drive - Building Plans: ResidentialReviewed for Code Compliance Nicole Post RPS24-000139 12-19-24 Approved plans must be on site for the duration of the project. Plans must be available to inspector. Please call 952-249-6000 to schedule all inspections. Have permit number and address when calling. Separate Permits Required Plumbing Mechanical Electrical Sewer & Water Please plan accordingly. The City will not issue a Temporary Certificate of Occupancy (Temp CO) for new homes during the growing season from May 1st to November 1st. Issuance of a Certificate of Occupancy requires all permits associated with the project to be finaled and an as-built survey approved by the City. If vegetation is not fully established at the time of CO issuance, the erosion control escrow will continue to be held. #6 All footings 20 x 8 UNO Add 2 #4 bars in footing per engineer 3 (2 x 6) 1 2x6 king 1 2x6 trim Per engineer 2 (2x6) See engineering for these three concrete headers with rebar See engineering for additional Simpson coiled strap. 2 Simpson STDH14 Straps each side per engineering Under Stair Protection Enclosed space under stairs that is accessed by a door or access panel shall have walls, under-stair surface and any soffits protected on the enclosed side with 1/2" gypsum board Openings between garage and residence shall have solid door 1 3/8" thickness, steel door or 20-minute fire rated doors Guards shall not be less than 36" in height and located along landings more than 30" from floor or grade below. Pinning wall to concrete plank #4 Dowels 2' OC see spancrete drawing Unprotected portions of floor shall not exceed 80 Sq Ft. Tension Ties required. 4 at #750 or 2 at #1500 Retaining walls over 4' require engineering and a separate permit. Provide fire blocking vertically at ceilings and floors, and horizontally at intervals not exceeding 10'. calcs 600 cfm with 10" interlocked makeup air Run LVL corner to corner per engineering Portal with straps per engineering Per MNF&G 505.4 Hoods exhausting in excess of 400cfm must provide heated makeup air at a rate approx equal to exhaust air rate 600 cfm hood with makeup air - 10" Tempered window required The two blue boxes are the only additional information to footing/foundation page A2.1 ERECTION NOTE: ALL WALLS ARE ASSUMED AS 10" C.I.P. W/ 4" WIDE BEARING LEDGE UNO. 30 ' - 2 " 26 ' - 2 " 10 " 1' - 0 " 2' - 2 " 34'-2" 10"11'-1" 10" 3'-1"10" 1'-2"16'-3" 1'-4" 9'-3"10" 10 " 25 ' - 0 " 10 " 26 ' - 8 " 8" H . C . P L A N K S P A N 3" GAIN 35 " W I D E SA W N E D G E 1 X1 1 X1 1 X1 3 X1 28 ' - 7 " P L A N K L E N G T H 33'-2" PLANK COVERAGE 25 ' - 7 " P L A N K L E N G T H 34'-5 1/2" 2'-3 1/4"2'-1 1/4" 7" 8" 9'-3" 10" 4'-4"3'-1" 2' - 0 " 3 X1 4 X1 5 X1 24 " W I D E 28 ' - 8 1 / 2 " P L A N K L E N G T H STEEL BEAM 1/2"2 X1 GUIDELINES FOR CUTTING OPENINGS NOT SHOWN ON PLAN: 1.ALL OPENINGS IN PLANK TO BE IN OPEN CORE AREAS ONLY. OPENING SIZE NOT TO EXCEED THE OPEN PLANK CORE WIDTH. 2.CARE MUST BE EXERCISED TO NOT CUT STRAND IN THE PLANK WEB AREAS. RELOCATE OPENINGS CONSIDERING THE STRAND LOCATION INDICATED IN THE CROSS-SECTIONS. 3.OPENING CLUSTERS MAY BE ARRANGED LONGITUDINALLY IN ONE PLANK CORE. FIELD CORE DRILLING THRU MORE THAN 1/3 OF PLANK WIDTH IS NOT PERMITTED. 4.PLANK OPENINGS THAT EXCEED PLANK CORE WIDTH OR CROSS PLANK WEB ARE NOT TO BE CUT WITHOUT PRIOR APPROVAL FROM THE MOLIN ENGINEERING DEPARTMENT. 5.ALL PLANK JOINTS ARE TO BE GROUTED PRIOR TO CUTTING ANY OPENINGS INCLUDING THOSE SHOWN ON PLAN. 5 5 / 8 " 1 3 / 1 6 " 1 3 / 1 6 " 5 7 / 8 " 2 1 / 8 " 8" 8" EXTRUDED PLANK 4'-0" 2 5/8" 5 1/2" 1 15/16" 2 5/8" 2" 7 1/8"7 7/16"7 7/16"7 7/16"7 7/16"7 1/8" 2" 5 1/2" 1 15/16" 5 1/2" 1 15/16" 5 1/2" 1 15/16" 5 1/2" 1 15/16" 5 1/2" 1'-11 7/8"1 1/8" 7 3/16"7 1/4"7 3/16" 1 1/8" 5 7 / 8 " 2 1 / 8 " 8" 8" FLEX PLANK 24" WIDE 1 X1 SCALE: 1/2" = 1'-0" SECTION 2 X1 SCALE: 1/2" = 1'-0" SECTION 4"6" BY OTHERS 4" SLOPED CONCRETE TOPPING 6"4" LAP 8" H.C. PLANK GROUT ALL PLANK JOINTS 3/4 PLANK DEPTH MIN (3000 PSI MIN) 10" POURED CONC. WALL BY OTHERS WATERPROOF MEMBRANE BY OTHERS CHECK BOX IF DETAIL APPROVED #4 DOWELS @ 2'-0" O.C. INSTALLER TO DRILL THRU PLANK & 4" MIN. INTO WALL & GROUT SOLID GROUT JOINT SOLID BY PLANK INSTALLER 4" BY OTHERS 4" SLOPED CONCRETE TOPPING 6"4" LAP 8" H.C. PLANK GROUT ALL PLANK JOINTS 3/4 PLANK DEPTH MIN (3000 PSI MIN) 16" POURED CONC. WALL BY OTHERS WATERPROOF MEMBRANE BY OTHERS CHECK BOX IF DETAIL APPROVED #4 DOWELS @ 2'-0" O.C. INSTALLER TO DRILL THRU PLANK & 4" MIN. INTO WALL & GROUT SOLID GROUT JOINT SOLID BY PLANK INSTALLER 6" 6"6" 3 X1 SCALE: 1/2" = 1'-0" SECTION 4 X1 SCALE: 1/2" = 1'-0" SECTION 6 1/2" 4"6" 3 1/2" BRG. 8" H.C. PLANK 1/8"x2" CONT. KOROLATH BRG. PAD 10" POURED CONC. WALL BY OTHERS #4 DOWELS @ 2'-0" O.C. INSTALLER TO DRILL THRU KEYWAY & 4" MIN. INTO WALL & GROUT SOLID WATERPROOF MEMBRANE BY OTHERS BY OTHERS 4" SLOPED CONCRETE TOPPING CHECK BOX IF DETAIL APPROVED GROUT JOINT SOLID BY PLANK INSTALLER 6 1/2" 4"6" 3 1/2" BRG. 8" H.C. PLANK 1/8"x2" CONT. KOROLATH BRG. PAD #4 DOWELS @ 2'-0" O.C. INSTALLER TO DRILL THRU KEYWAY & 4" MIN. INTO WALL & GROUT SOLID WATERPROOF MEMBRANE BY OTHERS BY OTHERS 4" SLOPED CONCRETE TOPPING CHECK BOX IF DETAIL APPROVED GROUT JOINT SOLID BY PLANK INSTALLER 16" POURED CONC. WALL BY OTHERS 6" 6" 5 X1 SCALE: 1/2" = 1'-0" SECTION W-BEAM BY OTHERS. (SEE LAYOUT FOR SIZE) PLANK INSTALLER TO FIELD WELD TO EMBED. PL'S 4"x4"x3/8" PL. CAST-IN PLANK @ 4'-0" O.C. 3/16"2" BM. CL BM. CL 10" WALL BY OTHERS (BEYOND) 8" H.C. PLANK1" WATERPROOF MEMBRANE BY OTHERS BY OTHERS 4" SLOPED CONCRETE TOPPING 4"6" PL O T D A T E : 12 / 2 / 2 0 2 4 2 : 1 3 P M FI L E N A M E : H: \ D w g F i l e s \ 2 0 2 4 J O B S \ 2 4 - 4 2 1 8 - R e s i d e n t i a l - L e v i t t \ L a y o u t D w g s \ C h e c k i n g \ O F A D r a w i n g s \ H o l l o w c o r e \ 4 2 1 8 ( 2 0 2 4 . 1 1 . 2 8 - H o l l o w c o r e - A p p r o v a l ) \ 4 2 1 8 H C L Y T A P P R O V A L . d w g FOR APPROVAL 415 Lilac Street, Lino Lakes, MN. 55014 Office 651-786-7722 Fax 651-786-0229 1-800-336-6546 www.molin.com Drafting Fax 651-783-3401 PROJECT NAME: PROJECT #: ADDRESS: SHEET DESCRIPTION: CONTRACTOR: PROJ. MANAGER: CHECKED BY:DRAFTER: ENGINEER: SHEET: SUBMITTAL / REVISION DATE BY PLEASE NOTE: THESE SHOP DRAWINGS AND SCHEDULES SHALL DETERMINE COMPLIANCE WITH CONDITIONS OF THE CONTRACT FOR THIS MATERIAL. ALL MATERIAL WILL BE SCHEDULED DIRECTLY FROM THESE DRAWINGS THEREFORE THEY SHOULD BE CHECKED ACCURATELY BEFORE APPROVAL IS GIVEN. ARCHITECT: Quality Concrete Solutions since 1897 STRUCTURAL ENGINEER: LECY BROS HOMES & REMODELING - - JB (612) 968-6749 ADVS-SHS ELK - (651) 203-1427 700 NORTH ARM DR ORONO MN 55364 RES - LEVITT X 24-4218-E (8" HOLLOWCORE FLOOR PLAN AND DETAILS) X1 KWC - (651) 203-1417 RAISED STRAND LOAD CHART DEAD WT=62PSF 8048 PLAN NORTH SCALE: 8" HOLLOWCORE FLOOR PLAN 1/4" = 1'-0"MOLIN ERECTION SECTION(S): * DESIGN SI LOAD: 75 PSF LL. 50 PSF DL PREAPPROVAL NOTES: SIGNATURE REQUIRED, ALL PLANK WILL BE PRODUCED PER DIMENSIONS PROVIDED ON SHOP DRAWINGS - INSUFFICIENT/EXCESSIVE PLANK LENGTH/COVERAGE WILL BE THE RESPONSIBILITY OF THE CONTRACTOR SIGNATURE: __________________________ DATE: __________________________ PLEASE VERIFY: ·ALL DIMENSIONS ·ALL DETAILS ·SIZE AND LOCATION OF OPENINGS ·SUPER-IMPOSED LOADS FOR APPROVAL 12-2-24 SHS RAISED STRAND LOAD CHART DEAD WT=57PSF 8024 60° HOLLOWCORE 60° CHOKER (HOLLOWCORE) 2'-0" MAX. 2'-0" MAX. From: larson.jed@gmail.com <larson.jed@gmail.com> Sent: Wednesday, December 11, 2024 1:33 PM To: Mike Mann <mikemann@lecybros.com>; npost@oronomn.gov Cc: Brad@rdr-inc.com; 'Petersen, Kurt' <KPetersen@SCHERERBROS.COM> Subject: RE: Single Reviewer Plan Review, 700 North Arm Dr, Additional Information Requested I have reviewed the items listed below in the email from Nicole Post, Building OAicial and would like to comment on a couple of the structural items. The 2” sill plate overhanging the foundation wall – I have reviewed the loads to the exterior walls and looked at the details for the overhanging sill plates.  There are typically 2-2x8 sill plates on top of the concrete foundation walls supporting the floor trusses.  At the lookout walls there is one 2x8 plate plus a 2x6 bottom wall plate. These plates are bolted to the concrete foundation with 1/2" diameter anchor bolts, as noted on the details. The 2” overhang for the plates is fine. I recommend that at all of the walls the sill plates are bolted to the concrete with 1/2" diameter anchor bolts spaced at 4’-0” o.c. For the bearing of the girder truss over the garage; the load at each end is 17,800 lbs. I do not recommend that the sill plate be removed to bear directly on the concrete. I prefer to use large enough posts to spread the load out on the wall bottom plate to preventing crushing in the sill plate. I recommend that 6 – 2x6 studs be installed below each end of the four ply girder truss. The studs can be oAset from the centerline of the girder, but not more that 2”. The compression perpendicular to the grain in the foundation plate will be 359 psi, which is within the allowable stress for a plate. Let me know if you have any questions. Jared K. Larson, P.E. Structural Engineer Minnesota Reg. No. 15847 Larson Associates, Inc. 2381 Eaken Avenue NE BuAalo, MN 55313 763-682-9530