HomeMy WebLinkAbout1380 Rest Point Road - Building Plans: ResidentialScale Project number Date Drawn by AVA STUDIO 4332 BROOKSIDE AVE, ST LOUIS PARK, MN 55436 PHONE 612 532 8159 EMAIL AVASTUDIO.AB1@GMAIL.COM 12" = 1'-0" 10 / 4 / 2 0 2 3 1 1 : 0 3 : 5 3 A M A01 Cover Page 1380 Orono 1380 Rest Point Rd 9/20/2023 Alexander Bocharnikov ALL PLANS ARE TO BE REVISED BY THE GENERAL CONTRACTOR AND THE MUNICIPAL BUILDING OFFICIAL PRIOR TO CONSTRUCTION. AVA STUDIO LLC. IS NOT RESPONSIBLE FOR ANY PROBLEM AS A RESULT OF AN ERROR OMISSION ON THESE PLANS. PLAN INFORMATION CODE INFORMATION Sheet List Sheet Number Sheet Name A02 Elevations A03 Foundation / Basement A04 Main Level A05 Upper Level A06 Roof Plan A07 House Section A08 Garage & Front Porch Section E1 Basement E2 Main Level E3 Upper Level A09 Section & Radon A10 Bracing Notes A01 Cover Page A11 Bracing Plans Area Schedule Area Level Name 1896 SF Second Floor Upper Level 1231 SF Basement Floor Finished Basement 1624 SF First Floor Main Level 820 SF First Floor Garage 176 SF First Floor Porch 484 SF First Floor Deck 76 SF Basement Floor Stairs 143 SF Basement Floor Mech Room FRAMING NOTES: -ALL EXTERIOR WALLS TO BE 2X6 @ 16" O.C. WITH A DOUBLE TOP PLATE UNLESS OTHERWISE NOTED. -WALL FRAMING SHALL BE S.P.F. STUD GRADE OR BETTER UNLESS NOTED OTHERWISE (U.N.O.) -ALL HEADERS SHALL BE (2) -2X10 U.N.O. -EXTERIOR SHEATHING SHALL BE 7/16" MATERIAL CONSISTING OF ORIENTED STRAND BOARD (OSB). -ALL FLOOR AND CEILING SYSTEMS TO CHECKED AND DESIGNED BY THE DESIGNATED MANUFACTURER. TRUSS PLANS TO BE ON SITE @ TIME OF FRAMING -PRESSURE TREATED WOOD IS TO BE USED WHERE WOOD IS IN CONTACT WITH CONCRETE AND AT 2X8 MUD SILL. TREATED MEMBERS TO BE S.Y.P. #2 OR BETTER. -FOR OPENINGS IN EXTERIOR WALLS (OR WALLS WITH LATERAL LOADING: a) 0'-0" -4'-0" = 1 JACK STUD b) 4'-0" -8'-0" = 2 JACK STUDS c) 8'-0" -12'-0" = 3 JACK STUDS d) GREATER THEN 12' = CONSULT ENGINEER. -POSTS CALLED OUT ARE NUMBER OF KING STUDS REQUIRED PER SIDE OF OPENING. CONCRETE NOTES: -ALL CONCRETE FOOTINGS AND FOUNDATION SYSTEMS ARE DESIGNED FOR A 2000 P.S.F. SOIL -FOUNDATION WALLS SHALL BE FULL HEIGHT AT UNBALANCED FILL GREATER THEN 3'-4" -1/2" ANCHOR BOLTS EMBEDDED 7" MINIMUM @ 4' O.C. MAX. 12" MIN. FROM EACH END. MINIMUM OF 2 BOLTS IN EACH SILL PLATE -PAD FOOTINGS REINFORCEMENT IS TO BE LOCATED 3" FROM BOTTOM OF FOOTING TYP. (WHEN REQUIRED) -CONTRACTOR IS RESPONSIBLE FOR ALL STEEL REBAR SIZING PER STATE AND LOCAL BUILDING CODES -MIN. 5000 PSI CONCRETE @ ALL FOOTINGS INSULATION: -ALL EXTERIOR WALLS TO HAVE A MINIMUM RATING OF R-20 -ALL ATTIC SPACES ARE TO HAVE A MINIMUM RATING OF R-49 -ALL FLOOR SPACES OVER UNCONDITIONED SPACE OR CANTILEVERED ARE TO HAVE A MINIMUM RATING OF R-30 SHEETROCK: -ALL CEILINGS ARE TO HAVE 5/8" NON-SAG GYPSUM BOARD U.N.O. -ALL WALLS ARE TO HAVE 1/2" GYPSUM BOARD U.N.O. -GARAGE CEILING AND WALLS THAT ADJOIN HOUSE WALLS ARE TO BE 5/8" TYPE "X" GYPSUM BOARD U.N.O. -ALL EXTERIOR WALLS OF GARAGE AND HOUSE THAT ARE WITHIN 5' SETBACK TO HAVE 5/8" TYPE "X" EXTERIOR GRADE GYPSUM BOARD ON EXTERIOR SIDE OF WALL AND 5/8" TYPE "X" ON INTERNAL SIDE OF WALL. DOORS AND WINDOWS: ALL WINDOWS AND DOORS TO NE DOUBLE GLASS PANELS WITH LOW-E RATINGS. -ANY WINDOW WITHIN 24" OF A DOOR SWING MUST BE TEMPERED -ANY WINDOW ABOVE A TUB MUST BE TEMPERED -ANY WINDOW WITHIN A STAIRWAY MUST BE TEMPERED -WINDOW GLAZING MUST BE AT LEAST 18" ABOVE FINISHED FLOOR WHEN WINDOW IS ABOVE 6' FROM GRADE. -ALL BEDROOMS TO HAVE AT LEAST ONE WINDOW THAT HAS A CLEAR EGRESS OPENING OF 5.7 SQ. FT. WITH MIN. DIMENSIONS OF 24" IN HEIGHT AND 20" IN WIDTH, SILL HEIGHT NOT TO BE GREATER THEN 44" ABOVE FINISHED FLOOR. -WINDOWS WITH SILLS WITHIN 3' OF THE FLOOR THEY SERVE AND ARE 72" ABOVE GRADE MUST EITHER HAVE A FALL PREVENTION OR OPENING LIMITER DEVICE PER CODE. MECHANICAL & ELECTRICAL: -ALL ELECTRICAL AND MECHANICAL EQUIPMENT TO BE VERIFIED AND INSTALLED PER CODE BY APPROVED TRADES AND INSTALLERS. PLAN INFORMATION CODE INFORMATION SOIL TYPE: DESIGNED WITH 2000 PSF SOILS, ALL FOUNDATION CONSTRUCTION MUST FACTOR IN THIS AT MINIMUM GENERAL NOTES: -ALL FOUNDATION WALL STRUCTURAL INFORMATION USED TO CONSTRUCT THE FOUNDATION SYSTEM IS TO BE ON SITE WHEN POURING OR BUILDING WALLS. -ALL STRUCTURAL BEAMS, POSTS & TALL WALLS ARE TO BE BUILT PER I-LEVEL SPECIFICATIONS. -ALL MANUFACTURED FLOORS & ROOF TRUSSES ARE TO BE INSTALLED PER MANUFACTURERS SPECIFICATIONS. -ALL MANUFACTURED FLOOR & ROOF TRUSS SPECIFICATIONS ARE TO BE ON SITE DURING INSTALLATION. WINDOW AND EXTERIOR DOOR U- FACTOR TO BE 0.30 OR BETTER GLASS SOLAR HEAT GAIN COEFFICIENT (SHGC) TO BE 0.28 OR BETTER WINDOW FALL PREVENTION DEVICES AND WINDOW GUARDS SHALL COMPLY WITH THE REQUIREMENTS OF ASTM F 2090 CODE INFORMATION: SINGLE FAMILY CONSTRUCTION TYPE V-B -2020 MINNESOTA STATE RESIDENTIAL CODE -2020 NATIONAL ELECTRICAL CODE -2020 MINNESOTA STATE MECHANICAL&FUEL GAS CODE -2020 MINNESOTA STATE FIRE CODE -2020 MINNESOTA PLUMBING CODE WIND EXPOSURE: DESIGNED WITH "EXPOSURE B" CLASSIFICATIONS AND WIND GUSTS OF 115 MPH PER 2020 MN IRC CODE REGULATIONS. 12" = 1'-0"1 3D View 1 12" = 1'-0"2 3D View 2 Reviewed for Code Compliance Nicole Post RPS24-000003 3-6-24 Additional permits required: Plumbing Mechanical Electrical Sewer Stamped and approved plans must be on site for the duration of the project and all inspections. To schedule inspections call: 952-249-4613 Please have the permit number and street address ready at time of call. Please plan accordingly. The City will not issue a Temporary Certificate of Occupancy (Temp CO) for new homes during the growing season from May 1st to November 1st. Issuance of a Certificate of Occupancy requires all permits associated with the project to be finaled and an as-built survey approved by the City. If vegetation is not fully established at the time of CO issuance, the erosion control escrow will continue to be held. Handrail is required with 4 or more risers. T.O. Foundation 951' -0" T.O. First Floor 961' -9 3/8" Second Floor 963' -4 1/8" Roof 971' -5 1/4" First Floor 952' -8 1/4" T.O. Garage Foundation 952' -6" 66 5 5 31 ' - 1 0 " 12 14 14 15' - 0" 2' - 7 " T ALUMINUM SOFFIT AND FASCIA LP SMARTSIDE LAP SIDING ASPHALT SHINGLES EPDM MEMBRANE FLAT ROOF 36" HIGH RAILING 6X6 POST FRAMED OUT TO 12" X 12" COLUMN WRAPPED W/ LP TRIM TT STANDING SEAM METAL ROOF 4" WINDOW AND DOOR TRIM TYP. 6 DECORATIVE WOOD BRACKETS 2' - 0" 1' - 0" 1' - 0" 2' - 0" 1' - 0" 1' - 0" 1' - 6"1' - 6" RIDGE VENT T T 120v ceiling outlet 0' - 6 " 2' - 0" 1' - 0"1' - 0" 1' - 11 5/8" 2' - 0" 12 12 6 6 5 T T T 6 T T T T 12 1' - 6" 1' - 0" 2' - 0"2' - 0" 1' - 6" 1' - 0" ALUMINUM SOFFIT AND FASCIA LP SMARTSIDE LAP SIDING ASPHALT SHINGLES 36" HIGH RAILING STANDING SEAM METAL ROOF 4" WINDOW AND DOOR TRIM TYP. RIDGE VENT COVER EXPOSED FOAM WITH STUCCO OR SIMILAR TYP. 6" MIN. BETWEEN GRADE AND WOOD FRAME SLOPE GRADE AWAY FROM BUILDING TTT T T T T T T 2' - 0" 6 6 5 12 12 1' - 0"1' - 0" 1/4" = 1'-0"1 Front Elevation ALL PLANS ARE TO BE REVISED BY THE GENERAL CONTRACTOR AND THE MUNICIPAL BUILDING OFFICIAL PRIOR TO CONSTRUCTION. AVA STUDIO LLC. IS NOT RESPONSIBLE FOR ANY PROBLEM AS A RESULT OF AN ERROR OMISSION ON THESE PLANS. Scale Project number Date Drawn by AVA STUDIO 4332 BROOKSIDE AVE, ST LOUIS PARK, MN 55436 PHONE 612 532 8159 EMAIL AVASTUDIO.AB1@GMAIL.COM As indicated 10 / 4 / 2 0 2 3 1 1 : 0 3 : 5 6 A M A02 Elevations 1380 Orono 1380 Rest Point Rd 9/20/2023 Alexander Bocharnikov 1/8" = 1'-0"2 Left Elevation 1/8" = 1'-0"3 Rear Elevation 1/8" = 1'-0"4 Right Elevation Handrail is required with 4 or more risers. 42 " X 2 4 " F I X E D 42 " X 2 4 " F I X E D 30 " X 5 4 " CA S E M E N T 48"X24" FIXED48"X24" FIXED 16' GARAGE DOOR ABOVE 18 " W E B T R U S S E S AB O V E @ 1 9 . 2 " O . C . W C 8' -9 1/2" CEILING 16'6" X 17'5" CARPET FLOOR 8' -9 1/2" CEILING 16'1" X 17'5" CARPET FLOORFAN SD 36 " V A N I T Y SDCM CONC. PAD 20" W. X 8" D. UNDER BEARING WALL TYP. NOTE: 2X4 BEARING WALL SDCM UP 1 A07 9' GARAGE DOOR ABOVE 60" x 32" SHOWER C.T. FLOOR & WALLS60 " X 5 4 " S L I D E R R. O . 5 ' 6 " X 6 ' 8 " 28" X 80" 30 " X 8 0 " FU R N A C E S.P. W.H. RADON 2 A08 1 A09 32 " X 8 0 " 6' - 0 " TT-3225 TT-3225 TT-1700 TT-1700 7' - 2"4' - 0"3' - 10"11' - 3" 28 " X 8 0 " MECH ROOM 7' - 3 " 4' - 0 " 18 " W E B T R U S S E S AB O V E @ 1 9 . 2 " O . C . 5' - 1 " 13 ' - 3 " 7' - 6 " 2' - 8 3 / 4 " 12 ' - 8 1 / 4 " 3' - 9 " 3' - 9 " 6' - 0 " 7' - 3 " UNEXCAVATED FLEX ROOM FAMILY ROOMENTERTAINMENT AREA GUEST BEDROOM 28 " X 8 0 " 1' - 0 " 25 ' - 3 " 18 ' - 9 " 58' - 6" 12' - 0"20' - 3"26' - 3" 2' - 0"16' - 0"2' - 3"1' - 6"9' - 0"1' - 6" 36" HIGH RAILING TV 17' - 10"5' - 5"35' - 3" W.I.C. BATH 1 A08 3' - 0" 6' - 0 " 8' - 8 1 / 2 " 5' - 0 " 30" X 80" 28" X 80" 45 ' - 0 " 58' - 6" 5' - 1 " 7' - 7 1 / 4 " 5' - 3 1 / 2 " TOP CHORD BEARING TRUSSES BOTTOM CHORD BEARING TRUSSES 3' - 9 " 19 ' - 2 " 120" HIGH 6" CORE ICF WALL 20" X 8" CONC. FTG. 126" HIGH 6" CORE ICF WALL 20" X 8" CONC. FTG. 1' - 0" 28' - 0"11' - 0" 15 ' - 4 " 10 ' - 4 " 5' - 0 " 5' - 0 " 7' - 0"7' - 0"7' - 0"7' - 0" No 1 . T R E A T E D 2 X 1 0 @ 1 2 " O . C . 18' - 0"12' - 0" 1/2" GYP. BD. UNDER STAIRS TYP. FOUNDATION WALL STEP 28" X 80" INSULATED DOOR FOOTING STEP (SHELTER ROOM ROOF) 6" CONC. SLAB REINF. W/ #4's @ 12" O.C. MIN. EACH WAY PLACE 2" ABOVE BOTTOM OF SLAB TYP. W/ 18" #4 DOWELS AT 24" O.C. MIN. 2' - 8 " 3' - 0" SDSD 8' -9 1/2" CEILING 17'7" X 17'10" CARPET FLOOR 54" HIGH 6" CORE ICF WALL 20" X 8" CONC. FTG. 108" HIGH 6" CORE ICF WALL 20" X 8" CONC. FTG. 120" HIGH 6" CORE ICF WALL 20" X 8" CONC. FTG. LEDGE (SEE SECTION) LEDGE (SEE SECTION) 120" HIGH 6" CORE ICF WALL 20" X 8" CONC. FTG. 8' -9 1/2" CEILING 13'10" X 12'0" CARPET FLOOR 4' - 0 " 108" HIGH 6" CORE ICF WALL 20" X 8" CONC. FTG. SAND FILL 6' - 1 0 " 11 ' - 1 1 " DRAIN TILE TO SUMP PUMP 3 A09 (2 ) - 2X 1 0 H D R . DRAIN TILE TO SUMP PUMP (2 ) - 2X 1 0 H D R . AIR EX. 4" CONC. SLAB 2X8 WALL GI R D E R T R U S S IN TRUSS BEAM (T.B.D. BY TRUSS CO.) R. O . 3 ' 0 " X 5 ' 8 " 45 ' - 0 " FOOTING STEP (2 ) - 2X 1 0 H D R . (2 ) - 2X 1 0 H D R . 3 PLY 9 1/4" LVL HDR. 5' - 0"7' - 0" FOUNDATION WALL STEP FOUNDATION WALL STEP GR A N I T E C O U N T E R 2X 8 W A L L 2X8 WALL 2X 1 0 T R E A T E D @ 1 2 " O . C . 36" X 36" X 10" D CONC. FTG. UNDER BEARING POINT 12" DIA. C.I.P. CONC PIER 48" BELOW GROUND W/ 20" BELL WITH SIMPSON ABAZ66 POST BASE ATTACHMENT TO 6x6 POST w/ (1) 1/2" DIA. ANCHOR BOLT TYP. SIMPSON DTT2Z DECK TIE (OR EQ). 2X10 TREATED LEDGER BD. ATTACHED WITH LEDGERLOK 5" SCREWS "W" PATTENT 12" O.C. AND 2 AT EACH END OF LEDGER 12" DIA. C.I.P. CONC PIER 48" BELOW GROUND W/ 14" BELL WITH SIMPSON ABAZ66 POST BASE ATTACHMENT TO 6x6 POST w/ (1) 1/2" DIA. ANCHOR BOLT TYP. FOUNDATION WALL STEP SIMPSON DTT2Z DECK TIE (OR EQ). SIMPSON DTT2Z DECK TIE (OR EQ). 108" HIGH 6" CORE ICF WALL 20" X 8" CONC. FTG. 72" HIGH 6" CORE ICF WALL 20" X 8" CONC. FTG. 3' - 7" 7' - 1 1 " 2 A09 WATER TANK WATER FILTER SYSTEM 1/4" = 1'-0"1 Basement Floor ALL PLANS ARE TO BE REVISED BY THE GENERAL CONTRACTOR AND THE MUNICIPAL BUILDING OFFICIAL PRIOR TO CONSTRUCTION. AVA STUDIO LLC. IS NOT RESPONSIBLE FOR ANY PROBLEM AS A RESULT OF AN ERROR OMISSION ON THESE PLANS. Scale Project number Date Drawn by AVA STUDIO 4332 BROOKSIDE AVE, ST LOUIS PARK, MN 55436 PHONE 612 532 8159 EMAIL AVASTUDIO.AB1@GMAIL.COM 1/4" = 1'-0" 10 / 4 / 2 0 2 3 1 1 : 0 3 : 5 7 A M A03 Foundation / Basement 1380 Orono 1380 Rest Point Rd 9/20/2023 Alexander Bocharnikov See Engineering Provide fire blocking vertically at ceilings and floors, and horizontally at intervals not exceeding 10'. Mechanical Ventilation Required in all Toilet Rooms Unprotected portions of floor shall not exceed 80 Sq Ft. Joist size and spacing not on engineering. 42 " X 3 6 " F I X E D 42 " X 3 6 " F I X E D 30 " X 7 2 " F I X E D 30 " X 7 2 " F I X E D 30"X72" FIXED 30"X72" CASEMENT 30"X72" CASEMENT 24" X 36" FIXED 24" X 36" FIXED 24" X 36" FIXED 48"X96" FIXED72"X96" FIXED 48"X96" FIXED48"X96" FIXED48"X96" FIXED 42 " X 2 4 " F I X E D Ref.Ref. UP 60 " X 7 2 " F I X E D DW 60"X54" FIXED 16' x 8' O.H. DOOR 2 PLY -11 7/8" LVL HDR. 44 ' - 0 " 9' x 8' O.H. DOOR 2 PLY -11 7/8" LVL HDR. 1' - 0 " 25 ' - 0 " 19 ' - 0 " 25 ' - 0 " 1 A07 (3) -2X10 DROPPED BEAM SD CM SD 2 A08 5' - 6 " 13 ' - 6 " TT-3225 TT-3225 TT-1700 TT-1700 EL E C T R I C F . P . BU I L D I N BU I L D I N CARPET STAIRS TE M P E R E D 7' - 10"8' - 0"10' - 8" 12' - 0"5' - 9"40' - 9" 3' - 8"4' - 0" 3' - 8 " 7' - 0 " 3' - 9 " 28' - 0"11' - 0" 5' - 0 " 5' - 6 " 39 ' - 6 " 18 " W E B T R U S S E S AB O V E @ 1 9 . 2 " O . C . GREAT ROOM 36" HIGH RAILING DINING ROOM KITCHEN BEDROOM 2 PANTRY W.I.C. BATH MUDROOM PWDR. RM. FOYER STUDY 2' - 1 " 6' - 0 1 / 4 " 2' - 1 " 30" 30" 24" 36 " S I N K 36 " C O O K T O P 19 ' - 2 " 7' - 6 " 12 ' - 1 0 " 4' - 1" 5' - 2 3 / 4 " 8' - 0 3 / 4 " 5' - 2 3 / 4 " 7' - 10"8' - 0"10' - 8" 7' - 6 " 18 ' - 6 " 9' - 8 " 4' - 2 " 4' - 8 " 58' - 6" COVERED PORCH 12' - 0"20' - 0"26' - 6" 1' - 6"9' - 0"1' - 6"2' - 0"16' - 0"2' - 0"15' - 2"11' - 4" 7' - 10"7' - 4" 0' - 3" 7' - 5"8' - 6"9' - 10"4' - 9 " 0' - 9 " 58' - 6" DECK DECK 3 CAR GARAGE HEAT RISER BE N C H / L O C K E R S STEEL BEAM 1 A08 2' - 8 1 / 4 " 2' - 9 3 / 4 " OVEN 24" 15 ' - 4 " 9' - 9"4' - 4"3' - 8"14' - 3" WASHER / DRYER 3' - 0" 6' - 4"8' - 6 1/2"8' - 7 3/4"11' - 2 3/4"6' - 6"4' - 1"4' - 1"4' - 1"5' - 0" 30" WIDE LINEN CABIENT 2' - 0 " 1' - 0" 1' - 0 " 0' - 3 " 1' - 0"1' - 0" 3' - 10"4' - 0"3' - 10"3' - 6"5' - 8"5' - 8" SECOND FLOOR CANTILEVER 176 SQ FT T&G WOOD CEILING 3" CONC. TOPPING MIN. EPDM MEMBRANE 6" CONC. SLAB FLOOR 9' 1 1/8" CEILING 10'0" X 12'2" WOOD FLOOR IN TRUSS BEAM T.B.D. BY TRUSS MANUFACTURER 4' - 0 " 7' - 6 " 32" X 80" SERVICE DOOR 3' - 0 1 / 2 " 7' - 1 " 2' - 8 1 / 2 " 3' - 9 " 3' - 9 " 2' - 9 " 13 ' - 3 1 / 2 " 3' - 1 1 / 2 " GI R D E R T R U S S 18 " W E B T R U S S E S AB O V E @ 1 9 . 2 " O . C . 18 " W E B T R U S S E S AB O V E @ 1 9 . 2 " O . C . 4" BOX VAULTED CEILING 7'8" X 18'0" WOOD FLOOR 12 " D R O P P E D C E I L I N G @ O P E N I N G 1' - 0 " 1' - 0"1' - 0" 4" BOX VAULTED CEILING IN TRUSS BEAM T.B.D. BY TRUSS MANUFACTURER 8' - 5 1 / 2 " 1' - 0 " 7' - 1 3 / 4 " 2' - 4 1 / 4 " 2' - 0 " 14 ' - 5 1 / 2 " 14' - 11 1/4"2' - 0" 32" X 96" 20 MIN. FIRE RATED DOOR 28'0" X 15'4" COMPOSITE DECKING 28" X 96" 4" CONC. SLAB 5/8" TYPE-X GYP. BD. ON WALLS AND CEILING BETWEEN HOUSE AND GARAGE CO A T C L O S E T UP DN 4" BOX VAULTED CEILING 18'0" X 18'5" WOOD FLOOR TILE FLOOR FAN WC 42" VANITY 60" X 32" SHOWER 32" X 96" POCKET DR. 28" X 96" 32" X 96" POCKET DR. TILE FLOOR TILE FLOOR CU S T O M V A N I T Y 2' - 8 1/4" 28 " X 9 6 " PO C K E T D R . TILE FLOOR 9' 1 1/8" CEILING 11'3" X 12'9" WOOD FLOOR 2' - 3 " 30 " X 9 6 " PO C K E T 30 " X 9 6 " 30 " X 9 6 " 30" X 96" 18"18" 9' 1 1/8" CEILING 11'2" X 18'6" WOOD FLOOR 9' 1 1/8" CEILING 11'0" X 18'6" WOOD FLOOR 6' - 0 " 3' - 5 " 4' - 1 " ST E P 28 " X 9 6 " FAN W C (2 ) - 2X 1 0 H D R . (2 ) - 2X 1 0 H D R . (2 ) - 2X 1 0 H D R . (2 ) - 2X 1 0 H D R . (2 ) - 2X 1 0 H D R . (2 ) - 2X 1 0 H D R . (2 ) - 2X 1 0 H D R . (2 ) - 2X 1 0 H D R . (2) -2X10 HDR. 16" X 96" SIDELIGHT42" X 96" GLASS DOOR 11'0" X 5'0" COMPOSITE DECKING TE M P E R E D 2' - 1" SD SD CM SD3 PLY 9 1/4" LVL HDR.2 PLY 9 1/4" LVL HDR. 2 PLY 9 1/4" LVL HDR. 2 PLY 9 1/4" LVL HDR. GI R D E R T R U S S GI R D E R T R U S S 2' - 2" (3) -2X10 DROPPED BEAM(3) -2X10 DROPPED BEAM 1' - 0" IN TRUSS BEAM (T.B.D. BY TRUSS CO.) 3' - 6 " DECK CANTILEVER TREATED 2X10' SISTERED TO EACH SIDE OF FLOOR TRUSS TRUSSES TO BE DESIGNED TO SUPPORT DECK 3' - 6 " 7' - 6 " 2 A09 RADON 24" FD FD 30 " X 9 6 " PO C K E T 3 PLY 9 1/4" LVL HDR. OR STEEL BEAM T.B.D. BY ENGINEER 2 PLY 9 1/4" LVL HDR. 96" X 96" SLDING GLASS DR.96" X 96" SLDING GLASS DR. TEMPERED TEMPERED TEMPERED TEMPERED TEMPERED TEMPEREDTEMPERED DESK STEP 1/4" = 1'-0"1 First Floor ALL PLANS ARE TO BE REVISED BY THE GENERAL CONTRACTOR AND THE MUNICIPAL BUILDING OFFICIAL PRIOR TO CONSTRUCTION. AVA STUDIO LLC. IS NOT RESPONSIBLE FOR ANY PROBLEM AS A RESULT OF AN ERROR OMISSION ON THESE PLANS. Scale Project number Date Drawn by AVA STUDIO 4332 BROOKSIDE AVE, ST LOUIS PARK, MN 55436 PHONE 612 532 8159 EMAIL AVASTUDIO.AB1@GMAIL.COM 1/4" = 1'-0" 10 / 4 / 2 0 2 3 1 1 : 0 3 : 5 9 A M A04 Main Level 1380 Orono 1380 Rest Point Rd 9/20/2023 Alexander Bocharnikov Handrail is required with 4 or more risers. See Engineering Drain to daylight. Vent Calcs call for 300cfm Hood 60 " X 7 2 " F I X E D 36"X60" FIXED36"X60" FIXED36"X60" CASEMENT 48"X66" FIXED 36"X66" CASEMENT 36"X66" CASEMENT 30"X60" FIXED30"X60" CASEMENT 30"X60" FIXED 66"X66" FIXED 30 " X 2 4 " F I X E D 36"X42" FIXED 36"X42" FIXED 18' - 0" 1 A07 39 ' - 6 " DN LOFT MASTER SUITE SITTING AREA 19 ' - 2 " 7' - 6 " 12 ' - 1 0 " 14 ' - 1 1 " 4' - 3 " 8' - 10"9' - 2" 39 ' - 6 " 12 ' - 9 " 8' - 3 " 5' - 8 1 / 4 " 12 ' - 9 3 / 4 " 1' - 1 1 " 13 ' - 1 0 " 7' - 3 " 5' - 7 1 / 4 " 12 ' - 9 3 / 4 " 1 A08 27" CAB. W/ SINK 2' - 2 " 8' - 2 " 5' - 8 " 5' - 4 1 / 4 " 7' - 6 " 5' - 4 " 7' - 5 3 / 4 " 36" BEDROOM 3 W.I.C.BATH W.I.C. W.I.C.W.I.C. BATH MASTER BATH BEDROOM 4 BENCH LAUNDRY 5' - 5"9' - 9"8' - 1"8' - 1"11' - 0"5' - 8" LINEN 8' -1 1/8" CEILING 14'6" X 12'1" CARPET FLOOR 7' - 9"7' - 5" 15' - 2"14' - 10" 7' - 5"7' - 5" 3 PLY 9 1/4" LVL HDR.3 PLY 9 1/4" LVL HDR. 144" X 82" SLIDING GLASS DOOR DECK COMPOSITE DECKING 36" HIGH RAILING 3' - 6 " 13' - 3 1/4"2' - 6 1/2" 48' - 0" TEMPERED 36" X 66" FREE STANDING TUB TE M P . G L A S S D O O R A N D P A N E L 28" X 80" WC FAN 28 " X 8 0 " 28 " X 8 0 " 5' - 8 3/4"5' - 5 1/4" 4' - 0" 4' - 0" CARPET FL.TILE FL. FANW C 30 " V A N I T Y 60" X 32" SHOWER WASHER DRYER 30 " X 8 0 " 30 " X 8 0 " 32" X 80" 28 " X 8 0 " 28 " X 8 0 " 28" X 80" 30" 24" 30" 36" 4' - 0" 30 " X 8 0 " 30 " X 8 0 " 2' - 0"2' - 0" 2' - 0 " (2) -2X10 HDR. BU I L T I N BU I L T I N 12" BOX VAULTED CEILING 17'3" X 14'6" CARPET FLOOR 12" BOX VAULTED CEILING 14'6" X 13'1" TILE FLOOR 1' - 0" 2' - 0 " 2' - 0 " 3' - 0" 8' -1 1/8" CEILING 17'3" X 3'11" CARPET FLOOR 8' -1 1/8" CEILING 14'6" X 7'0" CARPET FLOOR 5' - 4 " 7' - 5 3 / 4 " 11' - 2"4' - 0"5' - 5"5' - 4"5' - 5"6' - 2" 8' -1 1/8" CEILING 10'6" X 8'2" CARPET FLOOR 5' - 5 " 8' - 6 1 / 4 " 2X6 WALL 8' -1 1/8" CEILING 14'6" X 12'1" CARPET FLOOR CARPET FL.CARPET FL. 1' - 6 " 28 " X 8 0 " PO C K E T 28 " X 8 0 " PO C K E T 32" X 60" TUB/SHOWER 28 " X 8 0 " 28" X 80"28" X 80" W C FAN FAN TILE FLOOR 36"24"36"24" 3 PLY 9 1/4" LVL HDR. 96" X 82" SLIDING GLASS DOOR DECK 36" HIGH RAILING 8' -1 1/8" CEILING 16'0" X 12'1" CARPET FLOOR 3'4" HIGH 2X4 WALL W/ WOOD CAP 10' - 6" 36" HIGH RAILING 5' - 1 1 3 / 4 " 6' - 1 0 " 15' - 2"16' - 2"16' - 8" 48' - 0" 3' - 9 " 3' - 9 " (2 ) - 2X 1 0 H D R . 48" X 72" CUSTOM CURBLESS SHOWER 1 1/2" DROPPED FLOOR SD CM 22 " X 3 4 " AT T I C AC C E S S SDCM SD SD SD SD 9' - 2"1' - 1" 3' - 6 " COMPOSITE DECKING ON 2X TREATED SLIPERS OVER EPDM ROOFING 2' - 8 1 / 2 " EN G . R O O F T R U S S E S @ 2 4 " O . C . EN G . R O O F T R U S S E S @ 2 4 " O . C . 5' - 1 0 3 / 4 " 2' - 0 " 2 A09 RADON 10 ' - 6 " 2' - 4 " 2' - 1"5' - 4"5' - 4"2' - 1" TEMPERED TEMPERED 120v ceiling outlet 1/4" = 1'-0"1 Second Floor ALL PLANS ARE TO BE REVISED BY THE GENERAL CONTRACTOR AND THE MUNICIPAL BUILDING OFFICIAL PRIOR TO CONSTRUCTION. AVA STUDIO LLC. IS NOT RESPONSIBLE FOR ANY PROBLEM AS A RESULT OF AN ERROR OMISSION ON THESE PLANS. Scale Project number Date Drawn by AVA STUDIO 4332 BROOKSIDE AVE, ST LOUIS PARK, MN 55436 PHONE 612 532 8159 EMAIL AVASTUDIO.AB1@GMAIL.COM 1/4" = 1'-0" 10 / 4 / 2 0 2 3 1 1 : 0 4 : 0 0 A M A05 Upper Level 1380 Orono 1380 Rest Point Rd 9/20/2023 Alexander Bocharnikov See Engineering 6 1' - 0 " RIDGE VENT RI D G E V E N T 2' - 0" 1' - 6" 2' - 0 " 2' - 0 " 1' - 0 " 1' - 3" 1' - 3 " 14 14 6 6 5 5 12 12 6 COMPOSITE DECKING ON 2X TREATED SLIPERS OVER EPDM ROOFING 2' - 0 " 1' - 0 " 2' - 0" 1' - 6" 2' - 0 " 1' - 0 " 1' - 0 " 1' - 0" 1' - 0" 2' - 0" Scale Project number Date Drawn by AVA STUDIO 4332 BROOKSIDE AVE, ST LOUIS PARK, MN 55436 PHONE 612 532 8159 EMAIL AVASTUDIO.AB1@GMAIL.COM 1/4" = 1'-0" 10 / 4 / 2 0 2 3 1 1 : 0 4 : 0 0 A M A06 Roof Plan 1380 Orono 1380 Rest Point Rd 9/20/2023 Alexander Bocharnikov ALL PLANS ARE TO BE REVISED BY THE GENERAL CONTRACTOR AND THE MUNICIPAL BUILDING OFFICIAL PRIOR TO CONSTRUCTION. AVA STUDIO LLC. IS NOT RESPONSIBLE FOR ANY PROBLEM AS A RESULT OF AN ERROR OMISSION ON THESE PLANS. 1/4" = 1'-0"1 Roof Attic access is required. Shall be not less than 22" x 30" and be located in an accessible location. Basement Floor 942' -4" T.O. Foundation 951' -0" Second Floor 963' -4 1/8" Roof 971' -5 1/4" B.O. Footing 941' -4" First Floor 952' -8 1/4" T.O. Garage Foundation 952' -6" 8' - 9 1 / 2 " 1' - 6 3 / 4 " 9' - 1 1 / 8 " 8' - 1 1 / 8 " 1' - 6 3 / 4 " ENG. ROOF TRUSSES @ 24" O.C. NOTE: SEAL ALL VAPOR BARRIER PENETRATIONS RIDGE VENT 6" MIN. WOOD / EARTH SEPARATION 2X6 STUDS @ 16" O.C. 7/16" OSB SHTG. TYVAKE HOUSE WRAP SIDING PER ELEVATION GARAGE WALL: 1 A08 TAPER BLOCK 4' - 0 1/2" 3' - 7" 0' - 10" 0' - 7 1 / 4 " 0' - 7 1 / 2 " 0' - 10" 2 X 8 @ 16" O.C. 5' - 5 3 / 4 " 5' - 7 3 / 4 " TAPER BLOCK 18" ENG. WEB TRUSSES @ 19.2" O.C. R-49 BLOW IN INSUL. 4 MIL. POLY. V.B. 5/8" GYP. BD. 4" CONCRETE SLAB OVER 6 MIL. VAPOR BARRIER OVER 4" GRANULAR COMPACTED FILL DRAIN TILE TO SUMP PUMP 3/4" OSB SUBFL. 5/8" GYP. BD. CEILINGR-30 BLOW IN INSUL. 4 MIL. POLY. V.B. 5/8" TYPE X GYP. BD. 5/8" TYPE X GYP. BD. 36" HIGH RAILING STAIRCASE NOTES: #1 Treads must be a minimum of 10”and risers must be a maximum of 7 3/4”for residential stairs. #2 Handrail must be 34”to 38”above nose of tread and must terminate at wall or newel post. #3 Space between guards must be less than 4”. #4 Guards must be at least 34”high when measured vertically from nose of tread and 36”high on open sides of landings over 30” above floor or grade below. #5 Handrail grip size must be 1 ¼” min. to 2 5/8”max. diameter. #6 Nosing on stair treads must not exceed 1 1/4”, radius on edge of nosing not to exceed 9/16” 4" CONCRETE SLAB OVER 6 MIL. VAPOR BARRIER OVER 4" GRANULAR COMPACTED FILL 18" ENG. WEB TRUSSES @ 19.2" O.C. 3/4" OSB SUBFL. 5/8" GYP. BD. CEILING 1/2" GYP. BD. 1/2" GYP. BD. 36" HIGH RAILING 2 X 8 @ 16" O.C. 10 ' - 0 " FIRE BLOCKING @ 10' HEIGHT AT TALL WALL TYP. 10 ' - 6 " B.O. Garage Footing 947' -4" 2 A09 9' - 3 3 / 8 " Scale Project number Date Drawn by AVA STUDIO 4332 BROOKSIDE AVE, ST LOUIS PARK, MN 55436 PHONE 612 532 8159 EMAIL AVASTUDIO.AB1@GMAIL.COM 1/4" = 1'-0" 10 / 4 / 2 0 2 3 1 1 : 0 4 : 0 1 A M A07 House Section 1380 Orono 1380 Rest Point Rd 9/20/2023 Alexander Bocharnikov ROOF : VENT ROOF 1/300 TH. VALLEYS & ALL ROOF/WALL INTERSECTIONS 30 YR ARCHITECTURAL ASPHALTIC SHINGLES 15# ASPHALT FELT ICE & WATER SHIELD (FIRST 6'-0" AND ALL VALLEYS AS PER CODE) ENG. ROOF TRUSSES @ 24" O.C. 1/2" PLYWD. SHTG. W/ CLIPS AIR CHUTE (PROVIDE UNOBSTRUCTED AIR FLOW) (R-49) BLOW IN INSULATION 4 MIL. POLY VAPOR BARRIER 5/8" GYP. CEILING BD. FASCIA : 2X6 SUB FASCIA 6" ALUMINUM FASCIA ALUMINUM VENTED SOFFIT WALL : 1/2" GYP. BD. TYP. 4-MIL. POLY VAPOR BARRIER (R-20) FBGLS. BATT INSULATION 2X6 STUDS @ 16" O.C. 7/16" OSB SHEATHING TYVAKE HOUSE WRAP SIDING PER ELEVATION 20" X 8" CONC.FTG. W/ (2) #4 REBAR 5000 PSI MIN COMPRESSIVE STRENGTH RIM BETWEEN LOWER AND MAIN LEVELS 7/16" OSB RIM SHEATHING TREATED 2X8 SILL PLATE & SILL SEAL TYP. (R-20) CLOSED SELL FOAM INSUL. RIM DURASEAL OR SAME QLTY. FOUNDATION 1/2" DIAMETER A.B. W/ 7" MIN. EMBEDDED & 2" SIDE X 1/8" THICK SQUARE OR ROUND COUNTERSINK WASHERS @ 48" AND WITHIN 12" FROM EACH CORNER & WINDOW WELL DRAIN TILE TO SUMP PUMP WEATHER RESISTANT OPAQUE PROTECTIVE COATING TO 6" BELOW GRADE MIN. STUCCO OR SIMILAR POLY-WALL WATERPROOFING FACE AND TOP OF WALL 6" CORE NUDURA ICF BLOCK W/ REBAR PER MANUFACTURER SPECIFICATIONS FOUNDATION WALL (WALL HEIGHT AS SHOWN ON PLAN) RIM BETWEEN MAIN AND UPPER LEVELS 7/16" OSB RIM SHEATHING (R-20) CLOSED SELL FOAM INSUL. RIM DURASEAL OR SAME QLTY. 1/4" = 1'-0"1 House Section ALL PLANS ARE TO BE REVISED BY THE GENERAL CONTRACTOR AND THE MUNICIPAL BUILDING OFFICIAL PRIOR TO CONSTRUCTION. AVA STUDIO LLC. IS NOT RESPONSIBLE FOR ANY PROBLEM AS A RESULT OF AN ERROR OMISSION ON THESE PLANS. Basement Floor 942' -4" T.O. First Floor 961' -9 3/8" Second Floor 963' -4 1/8" Roof 971' -5 1/4" First Floor 952' -8 1/4" T.O. Garage Foundation 952' -6"0' - 6 " 10 ' - 0 " 8' - 9 1 / 2 " 1' - 6 3 / 4 " 9' - 1 1 / 8 " 1' - 0 " 9' - 3 3 / 8 " 2' - 5 " EN E R G Y H E E L B.O. Garage Footing 947' -4" BOTH SIDES TAPER BLOCK 2 PLY -11 7/8" LVL HDR.2 PLY 9 1/4" LVL HDR. 6" HIGH TOP CHORD 2X6 TREATED SILL PLATE 2X6 TREATED SILL PLATE 2X6 TREATED SILL PLATE 0' - 1 0 1 / 2 " 3' - 6" 36" HIGH RAILING LEDGER BD. 10 ' - 6 " Second Floor 963' -4 1/8" Roof 971' -5 1/4" B.O. Footing 941' -4" First Floor 952' -8 1/4" T&G WOOD SOFFIT 5' - 0"1' - 6" 0' - 7 1 / 2 " EN E R G Y H E E L 0' - 6 " 18" ENG. WEB TRUSSES @ 19.2" O.C. R-49 BLOW IN INSUL. 4 MIL. POLY. V.B. 5/8" GYP. BD. 4" CONCRETE SLAB OVER 6 MIL. VAPOR BARRIER OVER 4" GRANULAR COMPACTED FILL 5/8" GYP. BD. CEILING 3/4" OSB SUBFL. R-30 CLOSED SELL SPRAY FOAM INSULATION CANTILEVERED AREA TYP. 18" ENG. WEB TRUSSES @ 19.2" O.C. 3/4" OSB SUBFL. 5/8" GYP. BD. CEILING 3" CONC. TOPPING MIN. EPDM MEMBRANE 6" CONC. SLAB FLOOR (2) -2X10 HDR. (3) -2X10 DROPPED BEAM DRAIN TILE TO SUMP PUMP 2 LAYERS OF ICE AND WATER TO SEPARATE WOOD FRAME FROM CONCRETE SLAB LEDGE R-30 CLOSED SELL SPRAY FOAM INSULATION 2X8 JOISTS @ 24" O.C. Scale Project number Date Drawn by AVA STUDIO 4332 BROOKSIDE AVE, ST LOUIS PARK, MN 55436 PHONE 612 532 8159 EMAIL AVASTUDIO.AB1@GMAIL.COM 1/4" = 1'-0" 10 / 4 / 2 0 2 3 1 1 : 0 4 : 0 2 A M A08 Garage & Front Porch Section 1380 Orono 1380 Rest Point Rd 9/20/2023 Alexander Bocharnikov ALL PLANS ARE TO BE REVISED BY THE GENERAL CONTRACTOR AND THE MUNICIPAL BUILDING OFFICIAL PRIOR TO CONSTRUCTION. AVA STUDIO LLC. IS NOT RESPONSIBLE FOR ANY PROBLEM AS A RESULT OF AN ERROR OMISSION ON THESE PLANS. 1/4" = 1'-0"1 House / Garage Section 1/4" = 1'-0"2 Front Porch Section Engineered structural slab at stoop 3" MIN. ABS OR PVC OR EQUIVALENT GAS TIGHT PIPE SEAL ALL JOINTS BETWEEN SLAB AND FOUNDATION WALL 4" PERFORATED DRAIN TILE W/FILTER FABRIC 8"X16" ROCK TRENCH SEALED SUMP BASKET MIN 6 MIL OR 3 MIL CROSS LAMINATED POLY SHALL BE LAPPED 12" AND PLACED BELOW THE SLAB AND ON TOP OF 4" MIN. SAND GAS PERMEABLE LAYER INSTALL LABEL READING (RADON REDUCTION SYSTEM) ON THE VENT PIPE AT EACH FLOOR AND IN ACCESSIBLE ATTICS ALL CONTROL JOINTS, ISOLATION JOINTS CONSTRUCTION JOINTS AND ANY OTHER JOINTS IN CONCRETE SLABS SHALL BE SEALED WITH CAULK OR SEALANT SEAL ALL FLOOR OPENINGS ALL PIPE JOINTS AND FITTINGS TO BE GLUED OR TRANSITION COUPLINGS PROVIDE SPACE FOR FUTURE INSTALLATION OF A FAN *MIN. 24' DIAMETER CENTERED ON THE AXIS OR THE VENT STACK *MIN. VERTICAL DISTANCE 36" INSTALL LIVE OUTLET IN ATTIC WHERE FUTURE FAN MAY BE INSTALLED LIGHT FIXTURE IN ATTIC AREA Basement Floor 942' -4" Basement Ceiling 951' -1 1/2" T.O. First Floor 961' -9 3/8" Second Floor 963' -4 1/8" Roof 971' -5 1/4" B.O. Footing 941' -4" First Floor 952' -8 1/4" 3' - 6"7' - 6" 9' - 5 1 / 8 " 0' - 4 " 1' - 6 3 / 4 " 8' - 9 1 / 2 " 1' - 2 3 / 4 " 8' - 1 1 / 8 " 1' - 0 " 2' - 0" 5' - 10 3/4" STEEL BEAM 3 PLY 9 1/4" LVL HDR. COMPOSITE DECKING 36" HIGH RAILING 18" WEB TRUSSES ABOVE @ 19.2" O.C. TREATED 2X10' SISTERED TO EACH SIDE OF FLOOR TRUSS TRUSSES TO BE DESIGNED TO SUPPORT DECK 3 PLY 9 1/4" LVL HDR. 72" HIGH 6" CORE ICF WALL 20" X 8" CONC. FTG. 6 Basement Floor 942' -4" Basement Ceiling 951' -1 1/2" T.O. First Floor 961' -9 3/8" B.O. Footing 941' -4" First Floor 952' -8 1/4" 3' - 4 " DRAIN TILE TO SUMP PUMP (2) -2X10 HDR. Scale Project number Date Drawn by AVA STUDIO 4332 BROOKSIDE AVE, ST LOUIS PARK, MN 55436 PHONE 612 532 8159 EMAIL AVASTUDIO.AB1@GMAIL.COM 1/4" = 1'-0" 10 / 4 / 2 0 2 3 1 1 : 0 4 : 0 3 A M A09 Section & Radon 1380 Orono 1380 Rest Point Rd 9/20/2023 ALL PLANS ARE TO BE REVISED BY THE GENERAL CONTRACTOR AND THE MUNICIPAL BUILDING OFFICIAL PRIOR TO CONSTRUCTION. AVA STUDIO LLC. IS NOT RESPONSIBLE FOR ANY PROBLEM AS A RESULT OF AN ERROR OMISSION ON THESE PLANS. 1/4" = 1'-0"1 Passive Radon Plan 1/4" = 1'-0"2 Rear Deck Section 1/4" = 1'-0"3 Window Well Section Scale Project number Date Drawn by AVA STUDIO 4332 BROOKSIDE AVE, ST LOUIS PARK, MN 55436 PHONE 612 532 8159 EMAIL AVASTUDIO.AB1@GMAIL.COM 10 / 4 / 2 0 2 3 1 1 : 0 4 : 0 4 A M A10 Bracing Notes 1380 Orono 1380 Rest Point Rd 9/20/2023 Alexander Bocharnikov ALL PLANS ARE TO BE REVISED BY THE GENERAL CONTRACTOR AND THE MUNICIPAL BUILDING OFFICIAL PRIOR TO CONSTRUCTION. AVA STUDIO LLC. IS NOT RESPONSIBLE FOR ANY PROBLEM AS A RESULT OF AN ERROR OMISSION ON THESE PLANS. Portal Frame Wall Detail Method PFHBraced Wall Panel Floor Blocking Detail Braced Wall Panel Roof Blocking Detail Wall Corner Detail Portal Frame Garage Wall Detail Method CS-PF See Engineering for wall bracing DW BWL -1 BW L - A BW L - B BW L - C BWL -3 BWL -2 CS -W S P CS-WSPCONCRETE WALL CONCRETE WALL CO N C R E T E W A L L CO N C R E T E W A L L CO N C R E T E W A L L CONCRETE WALL CONCRETE WALL UNEXCAVATED 32' - 5"26' - 1" 19 ' - 0 " 26 ' - 0 " 58' - 6" 45 ' - 0 " 5' - 6 " 9' - 2 1 / 4 " 3' - 6 " 13 ' - 2 3 / 4 " 2' - 6 " 11 ' - 1 " 47' - 6"8' - 0"3' - 0" 4' - 4 " 5' - 0 " 9' - 8 " 800 LB-HOLD-DOWN DEVICE IN LIEU OF CORNER RETURN BWL -1 BW L - A PFH CS -W S P CS -W S P BW L - B BW L - C BWL -3 BWL -2 PFH PFH CS-PF CS-PF CS -W S P CS-WSP CS-PF CS-WSP CS-WSP CS -W S P CS -W S P CS -W S P 32' - 0"26' - 6" 1' - 6"10' - 6"2' - 0"16' - 0"2' - 0"6' - 10"2' - 4"6' - 0"1' - 11"7' - 6"1' - 11" 3' - 6 " 19 ' - 0 " 22 ' - 6 " 4' - 0 " 6' - 5 1 / 4 " 4' - 0 " 4' - 6 3 / 4 " 4' - 0 " 17 ' - 0 " 4' - 0 " 58' - 6" 2' - 4"8' - 0" 2' - 0 1/2" 5' - 0" 3' - 1 3/4" 6' - 0" 4' - 2 3/4" 24' - 9"3' - 0" 41 ' - 6 " 2' - 0 " 4' - 0 " CS -W S P GS GSGS 8' - 0"15' - 6"8' - 0" 2' - 8 " 5' - 4 " 14 ' - 5 " 3' - 7 " 4' - 1 0 1 / 2 " 9' - 9 1 / 2 " 15 ' - 1 1 1 / 2 " 4' - 7 " 6' - 3 1 / 2 " FIRE BLOCKING @ 10' 0" TYP. 800 LB-HOLD-DOWN DEVICE IN LIEU OF CORNER RETURN CS-WSPCS-PF BWL -1 BW L - A CS -W S P BW L - B BWL -2 CS-WSP FIRE BLOCKING @ 10' 0" TYP. CS-WSP CS-WSP CS-WSP CS -W S P CS -W S P CS-WSP CS-WSP CS-WSP CS-PF 48' - 0" 1' - 8"7' - 6"4' - 0"14' - 7"4' - 0" 2' - 7" 4' - 0"8' - 0"1' - 8" CS-PF 39 ' - 6 " 4' - 0 " 12 ' - 0 " 8' - 0 " 11 ' - 6 " 4' - 0 " 48' - 0" 2' - 9"10' - 0"3' - 0"13' - 8"3' - 5"12' - 0"3' - 2" CS -W S P CS -W S P CS -W S P 39 ' - 6 " 4' - 0 " 11 ' - 0 " 4' - 0 " 7' - 1 0 1 / 4 " 9' - 0 3 / 4 " 3' - 7 " 800 LB-HOLD-DOWN DEVICE IN LIEU OF CORNER RETURN Scale Project number Date Drawn by AVA STUDIO 4332 BROOKSIDE AVE, ST LOUIS PARK, MN 55436 PHONE 612 532 8159 EMAIL AVASTUDIO.AB1@GMAIL.COM 1/8" = 1'-0" 10 / 4 / 2 0 2 3 1 1 : 0 4 : 0 6 A M A11 Bracing Plans 1380 Orono 1380 Rest Point Rd 9/20/2023 Alexander Bocharnikov ALL PLANS ARE TO BE REVISED BY THE GENERAL CONTRACTOR AND THE MUNICIPAL BUILDING OFFICIAL PRIOR TO CONSTRUCTION. AVA STUDIO LLC. IS NOT RESPONSIBLE FOR ANY PROBLEM AS A RESULT OF AN ERROR OMISSION ON THESE PLANS. Where floor or roof framing members are perpendicular to exterior braced wall lines above or below, solid blocking shall be provided between the framing members at braced wall panel locations to permit fastening of wall plates in accordance with and shall extend to within 2 inches of the bottom side of the roof sheathing and shall be fastened in accordance with Table R602.3(1). Solid blocking to be provided @ floor trusses below braced wall panels. All framing and foundations shall be shored and temporarily braced as required by the contractor and all minimum nailing shall be in accordance with IRC Table R602.3(1). Lumber shall be minimum #2 SPF with treated lumber to be #2 S. Pine and engineered lumber to have Fb = 2600 psi with E = 2.0. Assume all lumber is of good quality and does not have large splits and checks and shall be visually inspected by the contractor at the time of construction. All fasteners in contact with treated lumber shall be G185 hot dipped galvanized or equal. General Bracing Notes Braced Wall Plan Abbreviations BWL. -Braced Wall Line BWP. -Braced Wall Panel CS-WSP. -Continuously sheathed wood structural panel GS. -Wall Panels sheathed w/gypsum board both faces PFH. -Portal Frame with Holdownds PFG. -Portal Frame Garage CS-PF. -Continuous Portal Frame WSP. -Intermittent wood structural panel HD. -Hold Down TT. -Tension Tie 1/8" = 1'-0"1 Basement Floor Copy 1 1/8" = 1'-0"2 First Floor Copy 1 1/8" = 1'-0"3 Second Floor Copy 1 See Engineering for wall bracing A B C A B C 1 2 3 1 2 3 PROPPED CANTILEVER FOUNDATION WALL NOTES: 1. FOOTING: DROP FOOTING FOR PROPPED CANTILEVER WALL THE TOP OF FOOTING SHALL BE 16 INCHES MINIMUM BELOW THE BOTTOM OF THE CONCRETE FLOOR SLAB. 2. FLOOR SLAB: THE INTERIOR CONCRETE FLOOR SLAB SHALL BE PLACED TIGHT TO THE WALL. REMOVE ICF INSULATION IN THIS AREA TO ALLOW FLOOR TO BE CAST TIGHT TO WALL. PROPPED CANTILEVER FOUNDATION (HATCHED AREA) SEE NOTES ABOVE 2 1 PIER 1 PIER 1 = 12" DIA. WITH 20" BELL PIER 2 = 12" DIA. WITH 14" BELL PIER 2 W20 FOOTING (UNLESS NOTED OTHERWISE)LOCATE TOP OF WALL STEP AT THE REAR OF THE STAIR WALL. STEP FOOTING DOWN 18" FOR PROPPED CANTILEVER FOUNDATION WALL STEP FOOTING DOWN 18" FOR PROPPED CANTILEVER FOUNDATION WALL UP PIER 1 PIER 1 PIER 1 PIER 1 PIER 2 PIER 2 WL6-1WL6-1 WL6-1 WL6-2 WL6-2 STRAP-TIE HOLDOWN STHD14 (TYP.) (8) TOTAL F3 WL6-3 WL6-4 WL6-4 WL6-5 WL6-3 WL6-3 WL6-3 WL6-2 WL6-6 WL6-7 W24 W24 W24W24 W20 A. CODES AND STANDARDS 1. 2020 MINNESOTA RESIDENTIAL CODE B. LOADS 1. DEAD LOADS ROOF DEAD LOAD.............................................20 PSF FLOOR DEAD LOAD...........................................20 PSF 2. LIVE LOADS FLOOR LIVE LOAD.........................................................40 PSF DECKS.............................................................................40 PSF 3. WIND LOAD...........................115 MPH................EXPOSURE D 4. SNOW LOADS a. ROOF GROUND SNOW LOAD..................................50 PSF b. Ce = 1.0, Ct = 1.0, I = 1.0 c. ROOF SNOW LOAD.................................................35 PSF C. GENERAL 1. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE DESIGN, INSTALLATION AND MAINTENANCE OF ALL TEMPORARY BRACING AND SHORING FOR THE STRUCTURE D. SITE WORK 1.BACKFILL - COMPACT ALL BACKFILL AT FOUNDATION WALLS TO AT LEAST 95% STANDARD PROCTOR DENSITY 2.BACKFILL - FOUNDATION WALLS SHALL BE BACKFILLED IN A MANNER THAT WILL PREVENT OVERTURNING OR LATERAL MOVEMENT OF WALLS. 3.FROST PROTECTION FOR HEATED STRUCTURES - EXTERIOR FOOTINGS FOR HEATED STRUCTURES ARE TO BE A MINIMUM DEPTH OF 4'-0" BELOW FINISHED GRADE UNLESS NOTED OTHERWISE ON THE PLANS. 4.FROST PROTECTION FOR UNHEATED STRUCTURES - STOOP FOUNDATIONS, CANOPY FOOTINGS AND ANY FOUNDATION AWAY FROM THE HEATED STRUCTURE IS TO HAVE 5'-0" MINIMUM COVER. 5.KEEP ALL FOUNDATION EXCAVATIONS FREE OF WATER DURING CONSTRUCTION 6.CENTER FOOTINGS ON WALLS OR COLUMNS, UNLESS NOTED OTHERWISE F. CONCRETE 1.MATERIALS FOOTINGS............................................................F'c = 5000 PSI SLAB ON GRADE..................................................F'c = 4000 PSI REINFORCING BARS.....ASTM A615....................Fy = 60,000 PSI WELDED WIRE FABRIC...ASTM A185..................Fy = 60,000 PSI 2.MIX - ALL EXTERIOR CONCRETE SHALL BE AIR ENTRAINED 6% WITHIN 1% 3.CONTROL JOINT CUTTING - SAWCUT CONTROL JOINTS IN SLAB WITHIN 8 HOURS OF SLAB PLACEMENT OR AS SOON AS SLAB CAN BE CUT WITHOUT EDGE RAVELING. 4.CONTROL JOINT SPACING - THE MAXIMUM CONTROL JOINT SPACING IS 12 FEET ON CENTER BOTH WAYS FOR C.I.P. CONCRETE SLABS AS A MINIMUM. REFER TO THE PLANS AND SPECIFICATIONS FOR POSSIBLE ADDITIONAL SPACING REQUIREMENTS. 5.REINFORCING - AT INTERSECTING WALLS, FOOTINGS, AND MASONRY BOND BEAMS, PROVIDE CORNER BARS TO MATCH THE HORIZONTAL REINFORCING. 6.REINFORCING - DO NOT HEAT BARS TO FIELD BEND 7.REINFORCING - PROVIDE ALL NECESSARY CHAIRS, SUPPORTS AND ACCESSORIES FOR INSTALLATION OF THE REINFORCING BARS. HORIZ. SLAB BARS VERT. BARS & REINFORCING BAR LAP SPLICES 6 3 5 4 SIZE WALL BARS 36" 18" 24" 30" 48" 24" 32" 40" HORIZ. FOOTING SCHEDULE MARK SIZE THICK.REINFORCING F2 2'-0" X 2'-0"1'-0"(3) #5 EA. WAY F2.5 2'-6" X 2'-6"1'-0"(4) #5 EA. WAY F3 3'-0" X 3'-0"1'-0"(4) #5 EA. WAY W20 1'-8"0'-8 (2) #4 CONTIN. W24 2'-0"0'-10"(2) #5 CONTIN. ICF WALL SCHEDULE MARK THICK.HEIGHT FILL PROPPED (c)VERT. (b)HORIZ.VERT. LOCATION FTG. DOWELS FTG. DOWEL HOOK ANCH BOLT SPACING WL6-1 6"4'-6"BOTH SIDES #4 AT 36 #4 AT 36 CENTER #5 x 20" AT 36"NO 72 WL6-2 6"9'-3"ONE SIDE #4 AT 8 #4 AT 36 INSIDE FACE (a)#5 x 20" AT 36"NO 24 WL6-3 6"8'-3"ONE SIDE #5 AT 16 #4 AT 36 INSIDE FACE (a)#5 x 20" AT 36"NO 48 WL6-4 6"6'-9"ONE SIDE 18"#5 AT 12 #4 AT 18 OUTSIDE FACE (a)#5 x 40" AT 12"12"48 WL6-5 6"9'-9"ONE SIDE 18"#5 AT 12 #4 AT 18 OUTSIDE FACE (a)#5 x 40" AT 12"12"48 WL6-6 6"9'-9"ONE SIDE #5 AT 8 #4 AT 36 INSIDE FACE (a)#5 x 20" AT 36"NO 24 WL6-7 6"9'-9"ONE SIDE #5 AT 8 #4 AT 36 INSIDE FACE (a)#5 x 20" AT 36"NO 24 NOTES: (a) 2" TO THE CENTERLINE OF REINF. (+/- 3/8") (b) INSTALL (2) ADDITIONAL #5 VERTICALS ON EACH SIDE OF OPENINGS - SEE LINTEL DETAIL (c) KNEE WALL POST BASE ABU66Z FOR 6 X 6 OR ABU88Z FOR 8 X 8 5' - 0 " MI N . B E L O W F I N A L G R A D E 2'-6" THIS INSULATION CAN BE ADDED FOR ADDITIONAL FROST PROTECTION SLOPED 2" RIGID INSULATION (BELOW GRADE) 1' - 0 " (1) #5 VERT. 12" DIA. CIP CONC.REFER TO PLAN VIEW FOR THE SIZE OF THE BASE 10 " (M I N . ) FORM 12" PORTION WITH A SONOTUBE FOR ADDED FROST PROTECTION - WRAP 12" DIA. PORTION WITH 6 MIL POLY 2" C L R . #5 AT 12" EACH WAY 6" MI N . #4 AT 24" 2' X 2' SLOPE 1/4" / FT #4 AT 24" 2' X 2' 3" TOPPING SLAB EPDM MEMBRANE Scale: 3/16" = 1'-0" FOOTING AND FOUNDATION1 OF SHEETS co n t e n t s JOB NO. pr o j e c t dr w n da t e re v i s i o n s ch k d 1 0 3 - 0 4 - 2 4 FO O T I N G A N D F O U N D A T I O N P L A N S1 N Scale: 3/4" = 1'-0" DECK PIER2 Scale: Not To Scale STOOP STRUCTURAL SLAB3 (1) #5 Vert (1) #5 Vert Per Architecturals, joists 2x10 12" OC 18 " F L R T R U S S E S AT 1 9 . 2 " O . C . 18 " F L R T R U S S E S AT 1 9 . 2 " O . C . G.T. A B C A B C 1 2 3 1 2 3 3 1 D 0.6 K L 1.2 K T 1.8 K UP 2 (F L U S H ) 2 X 8 BRG. WALL STRAP-TIE HOLDOWN STHD14 (TYP.) (8) TOTAL H0-2 H0-1 H0-1 H0-1 (2) 1-3/4 x 11-7/8 (FLUSH) P44 P44 H1-1 H1-1 H1-3 H0-2 FRAMING NOTES: 1. HEADERS.....MICROLAM.....E = 2.0....Fb = 2600 PSI.....Fv = 285 PSI BOTTOM PLATES ON CONCRETE..............................SYP NO. 2 (TREATED) OTHER PLATES.......................................................SPF NO. 2 OR BTR STUDS - BEARING WALLS .......................................SPF STUD GRADE STUDS - NON BEARING WALLS................................SPF STUD GRADE 2. FLOOR FRAMING MAX LL DEFL..............................L/480 OR 1/2" ROOF FRAMING MAX LL DEFL..................................L/240 OR 1" 3. WOOD ROOF TRUSSES TO BE MANUFACTURED BY EXPERIENCED TRUSS SUPPLIER. 4. PROVIDE BRIDGING FOR ROOF AND FLOOR TRUSSES SPACED AT THE LESSER OF 10' ON CENTER OR THE SPACING REQUIRED BY ROOF OR FLOOR TRUSS DESIGNER. 5. ROOF SHEATHING SHALL BE 1/2" THICK (EXTERIOR EXPOSURE 1 RATED 40/20) WITH H-CLIPS AS A MINIMUM; CONNECT ROOF SHEATHING TO TRUSSES WITH 8d. NAILS AT 6" ON CENTER AT PANEL PERIMETER AND AT 12" ON CENTER AT INTERMEDIATE FRAMING MEMBERS 6. FLOOR SHEATHING SHALL BE 3/4" T&G OSB AS A MINIMUM; CONNECT TO TRUSSES WITH 8d. NAILS AT 6" ON CENTER AT PANEL PERIMETER AND AT 12" ON CENTER AT INTERMEDIATE FRAMING MEMBERS 7. CONTINUE ALL POSTS AND COLUMNS DOWN TO THE TOP OF THE FOUNDATION, PROVIDE BLOCKING WITHIN THE FLOOR SYSTEM DEPTH THE SAME SIZE AS THE POSTS, TRIMMERS AND KING STUDS 8. PROVIDE TREATED WOOD PLATES WHERE WOOD IS IN CONTACT WITH CONCRETE 9. AT A MINIMUM, FASTEN EXTERIOR OSB SHEATHING WITH 8d NAILS, 6" AT EDGES, 12" AT INTERMEDIATE FRAMING MEMBERS. REFER TO BRACED WALL PLANS AND NOTES FOR ANY ADDITIONAL REQUIREMENTS. MANUFACTURED TRUSS NOTES: 1. TRUSS SPACING IS FOR REFERENCE ONLY AND MUST BE VERIFIED BY THE TRUSS MANUFACTURER. 2. S.W. = SHEAR WALL. 3. STRONGBACKS: INSTALL A MINIMUM OF 2 ROWS OF STRONGBACKS IN FLOOR SYSTEM FOR THE OTHER UNITS. INSTALL STRONGBACKS WITH A MAXIMUM SPACING OF 10 FEET BETWEEN ROWS. 4. H.D. = SHEAR WALL HOLD DOWN. 5. G.T. = GIRDER TRUSS LATERAL BRACING 1. WIND EXPOSURE D FIRST LEVEL 2. INSTALL PORTAL FRAMES AT OH DOORS AS SHOWN ON ARCHITECTURAL SHEET A10. 3. INSTALL STEEL MOMENT FRAME AT REAR WALL OF HOME. SEE DETAIL 2/S3. 4. INSTALL SHEAR WALL TYPE S.W.1 ON REAR AND LEFT WALL OF GARAGE. UPPER LEVEL 5. INSTALL OSB SHEATHING ON EXTERIOR WALLS WITH 8d NAILS 4" ON EDGE AND 12" ON INTERMEDIATE MEMBERS 8" 2" 2" FASTENERS (THIS SIDE) (3) ROWS AT 16" STAGGER ROWS FASTENERS (OTHER SIDE) (3) ROWS AT 16" STAGGER ROWS MULTI-PLY LVL FASTENERS FOR (3) PLY LVL USE SIMPSON WOOD SCREW FASTENERS 1/4 x 4 1/2 SDS 25 412 DB (DOUBLE BARRIER) SHEAR WALL SCHEDULE MARK SHEATHING EDGE SPA.INT. MEMBER SPA.FASTENER TYPE S.W.1 7/16" OSB 3 INCH 8 INCH 8d NAILS BASEMENT HEADER SCHEDULE MARK SIZE # TRIMMERS # KING STUDS H0-1 (2) 2 X 10 2 1 H0-2 (2) 1-3/4 X 9-1/2 LVL 2 1 Scale: 3/16" = 1'-0" 1ST FLOOR FRAMING1 OF SHEETS co n t e n t s JOB NO. pr o j e c t dr w n da t e re v i s i o n s ch k d 1 0 3 - 0 4 - 2 4 1S T F L O O R F R A M I N G P L A N S2 N Scale: Not To Scale LATERAL BRACING2 Scale: Not To Scale MULTI-PLY LVL FASTENERS3 P44 = (4)2x4 Header schedule page S3 Right CANTILEVER DECK W16 x 26 W16 x 26 2ND FLOOR CANTILEVER (SEE DETAIL FOR LOADS) A B C A B C 1 2 3 1 2 3 18 " F L R T R U S S E S AT 1 9 . 2 " O . C . 18 " F L R T R U S S E S AT 1 9 . 2 " O . C . 18 " F L R T R U S S E S AT 1 9 . 2 " O . C . RO O F T R U S S E S A T 24 " O . C . RO O F TR U S S E S AT 2 4 " O . C . RO O F TR U S S E S AT 2 4 " O . C . 2 X 8 FIRST FLR WALL 2 3 8' - 0 " 600 LB UPLIFT ON TRUSS (TYP.) 55 12 12 DECK (IN MFCTRD TRUSSES) 27'-5 1/4" 16'-3 3/4"11'-1 1/2" W16 x 26 HSS 5 X 3 3 5 ADJUST THE FLOOR TRUSS SPACING SO THE CANTILEVER DECK BEAMS ARE CENTERED BETWEEN (2) TRUSSES 3 4 D 0.7 K L 1.4 K T 2.1 K G.T. 2 X 6 BRG. WALL2 X 6 BRG. WALL 2 X 6 BRG. WALL 2 X 4 BRG. WALL 2 X 4 BRG. WALL 4 3 2 X 6 FIRST FLR WALL STEEL BEAM 16 X 50 (FLUSH) 7 3 5 4 6 4 ST E E L B E A M 1 6 X 5 0 (F L U S H ) (6) 2 X 6 TRIMMERS (4) 2 X 6 KING STUDS (3) 1-3/4 X 16 LVL HEADER P86 P86 P66 7 4 (3) 2 X 6 TRIMMERS (2) 2 X 6 KING STUDS (3) 1-3/4 X 11-7/8 LVL HEADER (2) 2 X 6 TRIMMERS (2) 2 X 6 KING STUDS SHEAR WALL S.W. TYPE 1 SHEAR WALL S.W. TYPE 1 TALL WALL FRAMING FOR HEADERS IN TALL WALL USE (2) 1-3/4 X 9-1/2 LVL TRIMMER - (1) 2 X 6 TRIMMER KING STUDS - (4) 1-3/4 X 5-1/2 1.55 E TIMBERSTRAND BALLOON FRAME FROM FIRST FLOOR LANDING UP TO 2ND FLOOR CEILING H1-2 H1-3 H1-4 H1-1 H1-1 H1-1 H1-1 POINT LOAD FROM JAMB ABOVE D 1700 LB S 3300 LB H1-3 H1-3H1-5 H1-3 (2) 1-3/4 x 11-7/8 (FLUSH) (3) 1-3/4 x 9-1/2 (FLUSH) P44 P44 P54 8 3 3 3 2 8 2 8 W 16 X 26 5/1/2" WIDE 15-3/4" TALL 1" PROVIDE 1" GAP BETWEEN STEEL AND 7/16" OSB EXTERIOR SHEATHING. INSULATE BETWEEN STEEL AND OSB WITH SPRAY FOAM INSULATION 7/16" OSB 6 3 INSTALL FLASHING TAPE OVER TREATED LVL BEAMS. TREAT CUT ENDS OF TREATED LVL BEAMS WITH 'ANCHOR SEAL' OR EQUIVALENT. UPLIFT ON FLOOR TRUSSES (SEE SECTION FOR LOAD) FLOOR TRUSS FLOOR TRUSS FLOOR BEAM (3) 1-3/4 X 9-1/4 TREATED LVL (2) 1 3/4 X 16 LVL HUC610 (UPSIDE DOWN) HUC416 (UPSIDE DOWN) HUC416 (UPSIDE DOWN) LINE LOAD ON CANTILEVER TRUSS 23.25 FT TRIB DL = 20 PSF SL = 35 PSF WALL DL = 100 LB/FT DL = 0.57 K/FT SL = 0.81 K/FT TL = 1.38 K/FT 1ST FLOOR HEADER SCHEDULE MARK SIZE # TRIMMERS # KING STUDS H1-1 (2) 2 X 10 2 1 H1-2 (2) 1-3/4 X 9-1/2 LVL 2 1 H1-3 (3) 1-3/4 X 9-1/2 LVL 3 2 H1-4 (3) 1-3/4 X 11-7/8 LVL 3 2 H1-5 (3) 1-3/4 X 11-7/8 LVL 4 2 ATTACH 2X TOP PLATE TO BEAM WITH (2) 1/2" DIA. BOLTS AT 16" O.C. OPTION - ATTACH WITH POWDER ACTUATED FASTENERS (ZF 47 P8S23 (2) FASTENERS AT 12") 2X TOP PLATE FULL WIDTH OF STEEL BEAM DOUGLAS FIR NO. 2 THA426 ADJUSTABLE STRAP HANGER W16 X 50 7.07" WIDE 16.3" TALL 1-3/4 X 9-1/2 LVL LEDGER ATTACH WITH (3) LEDGERLOK SCREWS AT 19.2" O.C. 2 X 6 BLOCKING BETWEEN TRUSSES. NAIL WITH (3) 16d NAILS. MANUFACTURED ROOF TRUSSES AT 24" O.C. 3/4" PLYWOOD SUBFLOOR Scale: 3/16" = 1'-0" 2ND FLOOR FRAMING1 OF SHEETS co n t e n t s JOB NO. pr o j e c t dr w n da t e re v i s i o n s ch k d 1 0 3 - 0 4 - 2 4 2N D F L O O R F R A M I N G P L A N S3 Scale: 3/8" = 1'-0" STEEL MOMENT FRAME2 N Scale: 3/8" = 1'-0" CANTILEVER DECK5 Scale: 3/4" = 1'-0" CANTILEVER BEAM CONNECTION6 Scale: 3/4" = 1'-0" CANTILEVER FLOOR JOIST LOADS4 Scale: 1-1/2" = 1'-0" STEEL MOMENT FRAME LOCATION3 Scale: 3/4" = 1'-0" GARAGE CEILING BEAM7 Scale: 3/4" = 1'-0" DECK FRAMING8 P44 = (4)2x4 P54= (5)2x4 RO O F T R U S S E S A T 24 " O . C . H2-2 H2-3 H2-2 H2-4H2-1H2-2H2-1H2-3 H2-1 H2-1 A B C A B C 1 2 3 1 2 3 1414 6 6 6 6 SINGLE TOP PLATE (FIELD VERIFY R.O. HEIGHT) 3 4 4 4 2ND FLOOR HEADER SCHEDULE MARK SIZE # TRIMMERS # KING STUDS H2-1 (2) 2 X 10 2 1 H2-2 (2) 1-3/4 X 9-1/2 LVL 2 1 H2-3 (3) 1-3/4 X 9-1/2 LVL 3 2 H2-4 (3) 1-3/4 X 11-7/8 LVL 3 2 SEE SCHEDULE PROVIDE BLOCKING WITHIN THE FLOOR SYSTEM DEPTH THE SAME SIZE AS THE TRIMMERS AND KING STUDS CONTINUE ALL POSTS, COLUMNS, TRIMMERS AND KING STUDS DOWN TO THE TOP OF THE PRECAST PLANK OR FOUNDATION WALL. BLOCKING BLOCKING NOTES: 1. SQUARE AND RECTANGULAR HOLES ARE NOT PERMITTED. 2. ROUND HOLES MAY BE DRILLED OR CUT WITH A HOLE SAW ANYWHERE WITHIN THE SHADED AREA OF THE BEAM. 3. THE HOIZONTAL DISTANCE BETWEEN ADJACENT HOLES SHALL BE AT LEAST TWO TIMES THE DIAMETER OF THE LARGER HOLE. 4. DO NOT DRILL MORE THAN THREE ACCESS HOLES IN ANY FOUR FOOT LONG SECTION OF BEAM. 5. BEAMS DEFLECT UNDER LOAD. SIZE HOLES TO PROVIDE CLEARANCE WHERE REQUIRED. BEAM DEPTH MAX. HOLE DIA. 5 1/2" 7 1/4" 9 1/4" - 12" 14" - 24" 3/4" 1" 2" 2 1/2" . . . 1/3 DEPTH 1/3 DEPTH 1/3 DEPTH 1/3 SPAN 1/3 SPAN END BEARING SEE NOTE 3 . . . 1/3 DEPTH 1/3 DEPTH 1/3 DEPTH 1/3 SPAN 1/3 SPAN END BEARING INTERMEDIATE BEARING SEE NOTE 3 . . . 1/3 DEPTH 1/3 DEPTH 1/3 DEPTH 1/3 SPAN1/3 SPAN END BEARING SEE NOTE 3 END BEARING SIMPSON CLIP H2.5A AT EACH TRUSS POST SCHEDULE MARK SIZE MATERIAL P44 (4) 2 X 4 SPF NO.2 P54 (5) 2 X 4 SPF NO.2 P64 (6) 2 X 4 SPF NO.2 P74 (7) 2 X 4 SPF NO.2 P46 (4) 2 X 6 SPF NO.2 P56 (5) 2 X 6 SPF NO.2 P66 (6) 2 X 6 SPF NO.2 P76 (7) 2 X 6 SPF NO.2 P86 (8) 2 X 6 SPF NO.2 ATTACH 2X TOP PLATE TO BEAM WITH (2) 1/2" DIA. BOLTS AT 16" O.C. OPTION - ATTACH WITH POWDER ACTUATED FASTENERS (ZF 47 P8S23 (2) FASTENERS AT 12") 2X TOP PLATE FULL WIDTH OF STEEL BEAM SECTION W16 X 50 7.07" WIDE 16.3" TALL 10 1 / 2 " ENERGY HEEL 5 12 1" 1/2" CLEARANCE FOR SPRAY FOAM INSULATION WELDED BASE PLATE PL 1-1/2 X 5 X 1'-0" WITH (2) 5/8" DIA. HOLES FOR (2) 1/2" DIA. X 6" LAG BOLTS 2 S P A . @ 3 " 2L's 3 1/2 x 3 x 3/8 x 0'-10-1/2" GA. 3" O.S.L. = 1 13/16" (3) 3/4" DIA. A325 BOLTS 2 S P A . @ 3 " 5 1 / 2 " 2 1/4" 3 1/2" 10 1 / 2 " 2 1 / 2 " 1 1 / 2 " 6" 6" WELDED BASE PLATE PL 1-1/2 X 5 X 1'-0" WITH (2) 5/8" DIA. HOLES FOR (2) 1/2" DIA. X 6" LAG BOLTS (6) 2 X 6 TRIMMERS (4) 2 X 6 KING STUDS (3) 1-3/4 x 16 LVL W16 X 50 7.07" WIDE 16.3" TALL Scale: 3/16" = 1'-0" ROOF FRAMING1 OF SHEETS co n t e n t s JOB NO. pr o j e c t dr w n da t e re v i s i o n s ch k d 1 0 3 - 0 4 - 2 4 RO O F F R A M I N G P L A N S4 N Scale: Not To Scale HEADER AND BLOCKING DETAIL3 Scale: Not To Scale HOLES AND NOTCHES IN LVL BEAMS2 Scale: Not To Scale TRUSS TO PLATE HOLD DOWN4 Scale: 3/4" = 1'-0" STEEL BEAM AT FRONT WALL5 Scale: 1-1/2" = 1'-0" STEEL BEAM TO STEEL BEAM CONNECTION6 Scale: 3/4" = 1'-0" STEEL BEAM BEARING AT OH DOOR7 At Garage Door