Loading...
HomeMy WebLinkAbout1994-11-04 On Site Sewage Treatment Inspection ReportCZTY OP OROMO Municipal Officts Post Office Box 66 Crystal Bay, MN SS323-0066 Owner:Qi 1 O o nix ’ill1.ffs0<msm ON-8ZTB SINXOB TRBJmmiT INSPECTION NBPONT ^Address:Sh Permit #• City ordinance rxjnber 100 requires that each on*site sewage treatinent system in Orono be inspected on a regular basis. The on*8ite sewage treatment system at the above address has been inspected and appears to fal'. into the category checked below. (This is an existing system [ ] new construction) 1 2 SYSTEM COWFOWMITY (1-3); ^ *'C00E SYSTEM"*A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. "CONfOMMIN'i SYSTEM"*A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the tin« of installation, and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. "NON-CONrORMING SYSTEM'**A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, 'xi construction standards of the current City and which is failing for any reason; and any system w less than 3 feet of unsaturated soil or s^ n the distribution deyice end the limiting'sou chArBCtertstles:—FTT TT \~1~^ \-Q1 ioil characteristichas or [ 1 has not been identified atfthis tll^. If the litMi has not been identified, this classification may be subject to reyision.) 9 Codes between (The limiting soil characteristic " I ting soil TANK COMOITIOM (5-10); Tank inspection indicates: 5 Punpout not needed at this time. 6 Solids acciflsulation in tanks indicates they should be punped out this year to help preyent future problems. 7 Solids accumulation in tanks is at a critical leyel. Tanks should be punped out as soon as possible. 8 9 System Inspection I is discharging to the surface. Tanks must be punped out within 48 hours to eliminate surface discharge, tion risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next punpout. If tanks have not been punped out within the last three years, they should be pu^wd out now. toy Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accunulation). If tanks have not been puipeci out within the last three years, they should be punped out now. DBAIMPIELD COMPITIOW (11-14):JX Dcmfffield inspection indicates: njy Orainfield is dry, no surfacing ^ Some evidence of surfacing, not 13 14 evident, critical yet. Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repairs must be completed within 90 days. Orainfield extent and cordition unknown. LIMITING SITE FACTORS (slooe.setbacks.etc.1: _ _ _ _ _ POTENTIAL FOR SYSTEM FAILURE Cdeoends on soils.water table.etc.): /7l^/y,7YUy^^ COMMENTS:^ Note: property. In the event that this inspection report is used to satisfy the requirements for a mortgage or other t y, be advised that this report does not guarantee or certify that an existing system will continue t y, but is merely an opinion of the ade^cy of the system under current conditions based on the transfer of to function available This report must be kept on the premises with the system location and pusping records. WHITE COPY /Inspactors File YELLOW COPY HomaoMmar j