Loading...
HomeMy WebLinkAbout1986-08-08 On Site Sewage Treatment Inspection ReportON SITE SEWAGE TREATMENT INSPECTION REPORT On the North Shore of Lake Minnetonka POST OFFICE BOX 66 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER /A L 5 PERMIT NO.’S.DATES ________ ADDRESS 1- 2^0! fe>K ST/i^BT CONTRACTORS .M(dSF City Ordinane# No. 210 roquim that each on-«ite sewage treatment system in Orono be inspected on a regular basis. The on-tita sewage treatment system at the above addieu has been inspected and appears to fall i .o the category checked below. (This it an existing system □ new construction) [~~1 • Meets or exeaedt current City standards in all respects relating to design, construction, aitd iocation. Appears to be operating ^ properly. pr 2 Dow •** current City standards lor new construction 11978 Code) but in most respects appears to be designed, I—I ^ located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no maior i-- if r upgrading of the system it required at this time. r~| 4 Does not meet current City standards in many respects relating to design, construction, or location. Appears to be operating ^ seWuaBiAlia a* tkSa fetna liett has a ralatiwalu hUlh AAtantial fnr fullira nrnhlamft. No iWBior UDOrAdifMI of fVltem it rMMlired Btadsquatelv at this time, but ha a relatively high potential lot future problems. No maior upgrading of system it required at this time. [- rn 4 System may or may not meet current City standards lor design, construction or location, but is failing to properly treat and ^ dispose of the current input, and it endangering a vMter supply, or it a source of pollution to surface or groundwaters, or it creating a safety haaard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuu system repair/ replacement procedures. If drainlield replacement it necetsaiy, toil testing will usually be required, and a design and site plan must be submitted for review. Your contractor mutt obtain a permit before work it started. s SYSTEM CONDITION ( GB Checked items may require your action) Tank inspection indicetet: - '0 Pumpout not needed at this tinte. □ Solids accumulatian in tanks indicates they should be pump* ad out this year to help prevent future proMems. □ Solids accumulation in tanks is at a critical level. Tanks should be pumped out at toon at possible. □ System it discharging to surface. Tanks mutt be pumped within 48 hours to eliminate surface discharge. □ Inspection risers missing-tanks could not be inspected. Inspection risers (4" die. pipe) mutt be installed in each tank at next pumpout. If iei«ks have not been pumped out within the last three years, they should be pumped out now. □ Inspection pipe it located directly over tank baffle. (Does not give accurate measurement of solids accumulation.) If tanks have not been pumpad out within the last three years, they should be pumpad out now. Drainfiald inspection indicatet: -----B Drainfiald is dry, no surfacing avidant. □ Some evidence of surfacing, not critical yet. □ Drainfiald is saturated and visiblv discharging untreated affluent to the surface. This condition may require replace* ment or additions to drainfiald. Contact the City Inspector immediately. Repairs mutt be completed within 90 days. □ Drainfiald extent and condition unknown. 1 SITE CHARACTERISTICS: Limiting Site Factors —-0 Slope □ Soil □ High water table □ Lot site □ Lake, wetland, or stream □ Drainage Potential for System Failure (depends on soil types, water table, and system condi'ion) ------B Low □ Medium □ High □ System is causing visible surface discharge. Site Capabilities for Future Expansion ------□ Adequate □ Fair □ Poor □ liradsquate 'if COMMENTS: 3 sr s' Date of Inspection ^tic System Inspector Note: In the event that this inspection report Is used to satisfy the requirementt for a mortgage or other transfer of property, be advised that thiu report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy of the system under current condit ons based on the available information. This report mutt be kept on the premises with system location and pumping records. WHITE COPY / Inspector s File GOLD COPY / Ho ner